    Operation Husky ® 1050A UL-Listed Diaphra gm Pumps Model 647016, Ev acuation and T ransfer Pump For use in general f uel transfer applications. 100 psi (0.7 MP a, 7.0 bar) Ma ximum Fluid W orking Pressure 100 psi (0.7 MP a, 7.0 bar) Maximum Air Input Pressure Model 647648, Fuel Dispense Pump For use in petroleum pr o duct dispense systems in accor ...

  • Husky 647016 - page 2

    Related Manua l 2 313597E Contents Related M anual . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 T o Order a New Pump: . . . . . . . . . . . . . . . . . . . . . . 3 T o Order P arts for Y our Existing Pump . . . . . . . . . 3 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 UL Listing Details . . . . . . . ...

  • Husky 647016 - page 3

    To Order a New Pump: 313597E 3 T o Or der a Ne w Pump: NO TE: Do not configure and order a pum p using only this manual. Work with your Graco distr ibutor or follo w the steps be low . 1. Go to www .gr acohusky .com. 2. Click on T oolbo x in the gra y banner near the top. 3. Click on the Husky 1050 Pump Selector , your choice of either the download ...

  • Husky 647016 - page 4

    Models 4 313597E Models UL Listing Details Models 647016 and 647648 are cer t ified per UL 79 for use in pumping gasoline and gasoline/alcohol bl ends up to 10 % ethanol, diesel fuel, fuel o il, and lubr icating oil. This cer tification does not cov er oil bur ner pumps; pumps f or engi ne-pow ered automotive equipment; or pumps f or use in m obile ...

  • Husky 647016 - page 5

    Warnings 313597E 5 Wa r n i n g s The f ollowing w ar nings are f or the setup , use, grounding, maintenance , and repair of this equip- ment. The e xclamation point symbo l aler ts you to a general w ar ni ng and the hazard symbol ref ers to procedure-specific risk. When these symbols appear in the body of this manual, refer bac k to these warning ...

  • Husky 647016 - page 6

    Warnings 6 313597E EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injur y . • Do not operate the unit when f atigued or under th e influence of drugs or alcohol. • Do not e xceed the maximum working pressure or temperature r a ting of the low est rated system co mponent. See T echnical Data in all equipment man uals. • Use fluids a ...

  • Husky 647016 - page 7

    Warnings 313597E 7 T O XIC FLUID OR F UMES HAZARD T oxic fluids or fumes can cause serious inju r y or death if splashed in the ey es or on skin, inhaled, or s wallo wed. • Read MSDS’ s to know the specific haz ards of the flui ds you are using. • Route e xhaust a wa y from work area. If diaphragm ruptures, fluid ma y be e xhausted with air . ...

  • Husky 647016 - page 8

    Installation 8 313597E Installation General Inf ormation • The T ypical Installations shown in F IG . 3 through F IG . 5 are only guides f or selecting and installing system components. Contact your Gr aco distributor f or assistance in planning a system to suit your needs . • Installation and use mu st be in accordance with the Flammable and C ...

  • Husky 647016 - page 9

    Installation 313597E 9 Air and fluid hoses: Use only grounded hoses with a maximum of 500 ft (150 m) com- bined hose length to ensure grounding continuity . Air compressor: Follo w manuf acturer’ s recommendations. Fluid supply container: F ollow local code . Solvent pails used when flushing: Fo l l o w local code. Use only c onductiv e metal pai ...

  • Husky 647016 - page 10

    Installation 10 313597E Air Exhaust V e ntilation The air e xhaust por t is 3/4 npt(f). Do not restrict the air exhaust por t. Excessiv e e xhaust restriction can cause er ratic pump operation. 1. Remov e the muffler (T) from the pump air e xhaust por t. 2. Install a grounded air e xhaust hose (U) and connect the muffler (T) to the other end of the ...

  • Husky 647016 - page 11

    Installation 313597E 11 Fluid Suppl y Line See F IG . 3 through F IG . 5, pages 11 through 13. 1. Use grounded, fle xible fluid supply lines (G). See Grounding , page 8. 2. If the inlet fluid pre ssure to the pump is more than 25% of t he outlet working pres- sure, the ball chec k v alves will not close f ast enough, resulting in inefficient pump o ...

  • Husky 647016 - page 12

    Installation 12 313597E Fluid Outlet Line See F IG . 3 through F IG . 5, pages 11 through 13. 1. Use grounded fluid hoses (G, K). See Grounding , page 8. 2. The pump fluid outlet is 1 in. npt(f). Screw the fluid fitting in to the pump outlet securely . 3. A fluid drain v alv e (H) is required in your system to relie v e pre ssure in the hose and di ...

  • Husky 647016 - page 13

    Installation 313597E 13 F IG . 5. Fuel dispense, t ypical installation Key: A Air supply line B Bleed-type master air valve (required for pump) C Air filter/regula tor assembly D Air inlet E Master air valv e (f or accessor ies) G G rounded, flexib le fluid supply line H Fluid drain valv e (required) J Fluid shutoff valve K Grounded, flexib le flui ...

  • Husky 647016 - page 14

    Installation 14 313597E Fluid Pressure Relief V alve Fuel Dispense System s (Model 647648) Evacuation and T ransfer Systems (Model 647016) Fuel dispense model 647648 requires a pres- sure relief v alve (S ), Gr aco par t 24B910, which is supplied with the pump , to pre v ent fluid pressure from e xceeding 50 psi (350 kP a, 3.5 bar). See F IG . 5, p ...

  • Husky 647016 - page 15

    Operation 313597E 15 Operation Pressure Relief Pr ocedure 1. Shut off the air supply to the pump . 2. Open the dispensing v alve (if used). 3. Open the fluid drain v alve to relie ve fluid pressure, ha ving a wa ste container ready to catch the drainage . Flush the Pump Bef ore First Use The pump was tested in w ater . If water could contaminate th ...

  • Husky 647016 - page 16

    Operation 16 313597E Gear Oil Evacuation Systems See F IG . 4. 1. Close the pump air re gulator (C) and the bl eed-type master ai r valv es (B, E). 2. Attach an appropriate wand to the suction hose. Place the w and in the differential or fluid to be pumped. 3. Place the end of the fluid hose into an appropriate container . 4. Close the fluid drain ...

  • Husky 647016 - page 17

    Maintenance 313597E 17 Maintenance Maintenance Schedule Establ ish a prev entive maintenance schedule , based on the pump’ s ser vice histor y . Sched- uled maintenance is es pecially impor tant to pre v ent spills or leakage due to diaphragm f ailure. Lubrication The pump is lubricated at the f actor y . It is designed to require no fur ther lub ...

  • Husky 647016 - page 18

    Maintenance 18 313597E T or que Instructions NO TE: Fluid cov er and manifo ld fasteners hav e a thread-locking adhesiv e patch applied to the threads. If this patch is e xcessively w or n, the f asteners ma y l oosen dur ing operation. Replace screws with new ones or apply medium-strength (blue) Lo ctite or equiv alent to the threads. If fluid cov ...

  • Husky 647016 - page 19

    Dimensions 313597E 19 Dimensions 5.0 in. 5.5 in. (140 mm) (127 mm) & % E A 1 0 3 / G F D ti14540a K J H ti12212b ti12211b ti12213b A ..... 12.7 in. (323 mm) B ..... 14.4 in. (366 mm) C ..... 15.9 in. (404 mm) D ..... 10.9 in. (277 mm) E ..... 1.8 in. (46 mm) F...... 7.3 in. (185 mm) G ..... 14.7 in. (373 mm) H ..... 6.2 in. (158 mm) J ...... 3. ...

  • Husky 647016 - page 20

    Performance Chart 20 313597E Pe r f o r m a n c e C h a r t T est Conditions: Pump tested in wate r with inlet submerged. 0 51 0 15 20 25 30 35 40 45 50 (19) (38) (57) (76) (95) (114) (133) (152) (1 70) (189) Fluid Outlet Pressure — psi (MPa, bar) A B C 0 5 10 15 20 25 30 35 40 45 50 (19) (38) (57) (76) (95) (114) (133) (152) (170) (189 ) Fluid F ...

  • Husky 647016 - page 21

    Technical Data 313597E 21 Te c h n i c a l D a t a * Sound po wer measu red per ISO-9614 -2. ** Sound pressure w as tested 3.28 ft (1 m) from equipment. All trademar ks mentione d in this manual are the prope r ty of th eir respective owners. Maximum flui d working pressure T ransfer Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Husky 647016 - page 22

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions. T his manual contains English. MM 313597 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Kore ...

Fabricante Husky Categoría Automobile Parts

Los documentos del dispositivo Husky 647016 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Husky
- manuales de instrucciones 647016
- hojas de producto Husky
- folletos informativos
- o etiquetas energéticas Husky 647016
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Husky 647016.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Husky 647016, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Husky 647016. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Husky 647016.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Husky 647016, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Husky 647016. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Husky 647016.

El manual de instrucciones completo de Husky debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Husky 647016 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Husky 647016, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Husky 647016 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Husky 647016 - que deben facilitarnos los primeros pasos durante el uso de Husky 647016
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Husky 647016
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Husky 647016 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Husky 647016?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Husky 647016, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Husky 647016 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)