    For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. This replace is approved fo ...

  • FMI (V)B42I - page 2

    www .fmiproducts.com 109036-01M 2 SAFETY W ARNING: Do not install a replace insert in this box unless the manufacturer's instructions with the insert specically state this replace has been tested for use with this insert. FOR YOUR SAFETY • Do not store or use gasoline or any other ammable vapors or liquids in the vicinity of this ...

  • FMI (V)B42I - page 3

    www .fmiproducts.com 109036-01M 3 SPECIFICA TIONS 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 3/4" AIR SP ACE BACK AND SIDES HEARTH EXTENSION 66" X 20" 12" EACH SIDE 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUT ...

  • FMI (V)B42I - page 4

    www .fmiproducts.com 109036-01M 4 FIREPLACE INST ALLA TION SELECTING LOCA TION T o determine safest and most efcient location for replace, you must take into consideration the following guidelines: 1. Location must allow for proper clearances (see Figures 1 and 2). 2. Consider a location where replace will not be affected by drafts, air co ...

  • FMI (V)B42I - page 5

    www .fmiproducts.com 109036-01M 5 HEARTH EXTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets the following specications: a ...

  • FMI (V)B42I - page 6

    www .fmiproducts.com 109036-01M 6 FIREPLACE INST ALLA TION Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch-Electrical Bushing Electrical Housing Wire Nut (3x) (Not Supplied) Outer Wrapper of Fireplace Electrical Cover Plate and Electrical Bushing Fireplace ...

  • FMI (V)B42I - page 7

    www .fmiproducts.com 109036-01M 7 Figure 8 - Lineal Gain Hemmed End 8" Stainless Inner Pipe 12 3 / 8 " Galvanized Outer Pipe Figure 7 - Outside Air Kit Secure to Collars with Metal T ape, Screws or Straps (Min. of 1/4" x 20" in size) Air Inlet Location Must Allow For Bushes or Snow V ent Hood Required for W all Installation Air ...

  • FMI (V)B42I - page 8

    www .fmiproducts.com 109036-01M 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S-8DM Return Elbow ...

  • FMI (V)B42I - page 9

    www .fmiproducts.com 109036-01M 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH A B 48" 36" 24" 18" 12" 4 3 / 8 " 16 3 / 8 " ELBOW SET ONL Y 9 3 / 4 " 25 1 / 2 " 1 12 3 / 4 " 30 3 / 4 " 1 15" 34 3 / 4 " 1 18" 40" 1 1 ...

  • FMI (V)B42I - page 10

    www .fmiproducts.com 109036-01M 10 VENTING INST ALLA TION Continued Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45.0° 20 3 / 8 " V12F-8DM 4. Remove shingles around opening mea - sured. Cut out this section. 5 . Add next sections of pipe until end pe ...

  • FMI (V)B42I - page 11

    www .fmiproducts.com 109036-01M 11 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - Storm Collar Chimney Pipe W aterproof Caulk Storm Collar Flashing Storm Collar Installation (SC1) Place storm collar over pipe and slide down until it is ...

  • FMI (V)B42I - page 12

    www .fmiproducts.com 109036-01M 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule 10 FOOT RULE All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above highest point where it passes through roof and must be at least 2 feet above highest point o ...

  • FMI (V)B42I - page 13

    www .fmiproducts.com 109036-01M 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make sur ...

  • FMI (V)B42I - page 14

    www .fmiproducts.com 109036-01M 14 OPTIONAL GAS LINE INST ALLA TION Continued W ARNING: If the replace has been used for wood burn- ing, rebox and chimney must be cleaned of soot, creosote and ashes be a qualied chimney cleaner . Creosote will ignite if heavily heated. OPERA TION AND MAINTENANCE Figure 23 - Glass Doors Cleaning Glass Clean ...

  • FMI (V)B42I - page 15

    www .fmiproducts.com 109036-01M 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued DAMPER HANDLE OPERA TION Damper handle, which opens and closes damper blade, is located inside rebox at center towards back w all (see Figure 24). Pushing handle back into keyway slot will free damper blade to automatically open. T o close, ...

  • FMI (V)B42I - page 16

    www .fmiproducts.com 109036-01M 16 P ARTS WOOD BURNING FIREPLACE MODELS (V)B42, (V)B42I, (V)B42L, (V)B42LI 11 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21 ...

  • FMI (V)B42I - page 17

    www .fmiproducts.com 109036-01M 17 P ARTS WOOD BURNING FIREPLACE MODELS (V)B42, (V)B42I, (V)B42L, (V)B42LI This list contains replaceable parts used in your replace. When ordering parts, see Replace- ment Parts on page 15 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 ** Insulation Pan • • 1 2 ** Air Separator • • 1 3 ** Firebox T ...

  • FMI (V)B42I - page 18

    www .fmiproducts.com 109036-01M 18 ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ANTI-DRAFT SHIELD (Round T op T ermination Only) ADS-8DM 30° OFFSET AND RETURN 30E-8DM ADJUST ABLE HOOD Antique Brass Finish - GA6053 Black Pai ...

  • FMI (V)B42I - page 19

    www .fmiproducts.com 109036-01M 19 F AN KIT - BK3 BLOWER KIT - BK OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KIT FOR FLOOR INST ALLA TION AK4F ACCESSORIES Continued SQUARE TOP TERMINA TION WITH LOUVERS ET -8DM, ET -8HT SQUARE TOP TERMINA TION WITH LOUVERS AND SLIP SECTION ETL-8DM, ETL-8HT MESH SQUARE TOP TERMINA TION ETO-8DM ME ...

  • FMI (V)B42I - page 20

    109036-01 Rev . M 03/1 1 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmipr oducts.com ...

Fabricante FMI Categoría Indoor Fireplace

Los documentos del dispositivo FMI (V)B42I que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos FMI
- manuales de instrucciones (V)B42I
- hojas de producto FMI
- folletos informativos
- o etiquetas energéticas FMI (V)B42I
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones FMI (V)B42I.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje FMI (V)B42I, instrucciones de servicio, instrucciones cortas o instrucciones de usuario FMI (V)B42I. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto FMI (V)B42I.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo FMI (V)B42I, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar FMI (V)B42I. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de FMI (V)B42I.

El manual de instrucciones completo de FMI debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual FMI (V)B42I - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice FMI (V)B42I, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de FMI (V)B42I que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo FMI (V)B42I - que deben facilitarnos los primeros pasos durante el uso de FMI (V)B42I
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con FMI (V)B42I
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de FMI (V)B42I en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de FMI (V)B42I?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con FMI (V)B42I, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con FMI (V)B42I probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)