Dimplex SI7MER - page 1
Sole/W asser- Wärmepumpe für Innenaufstellung SI 5MER SI 7MER SI 9MER SI 11MER Brine-to-W at er Heat P ump for Indoor Installation P ompe à chaleur eau gly colée-eau pour installation intérieur e Montage- und Gebrauchsanw eisung Deutsch English Français Instruc tions d’installation et d’utilisation Installation and Opera ting Instruc tion ...
-
Dimplex SI7MER - page 2
www.dimplex.de E-1 English Table of contents 1 Please Read Immediately ........................................ ............................................................... ...... E-2 1.1 Important Information ....... .................... ................ ................... ................ .................... ..... ................. ...... E- ...
-
Dimplex SI7MER - page 3
E-2 English 1 1 Please Read Immediately 1.1 Important Information ATTENTION! The heat pump is not secu red to the wooden pallet. ATTENTION! The heat pump must not be tilted more than 45° (in any direction) . ATTENTION! Do not use the holes in the panel assemblies for lifting the device! ATTENTION! Flush the heating system prio r to connecting the ...
-
Dimplex SI7MER - page 4
www.dimplex.de E-3 English 3 2 Purpose of the Heat Pump 2.1 Application The brine-to-water heat pump is designed for use in existi ng or newly built heati ng systems. Brine is used as the hea t carrier in the heat source syst em. Borehole heat exchangers, ground heat collectors or similar systems can be used as the heat source. 2.2 Operating Princi ...
-
Dimplex SI7MER - page 5
E-4 English 4 4 Accessories 4.1 Brine Circuit Manifold The brine circuit mani fold merges the individua l collector loops of the heat source system into a single main pipe which is con- nected to the heat pump . Integra ted ball val ves a ll ow the i ndi vid - ual brine circuits to be shut of f for de-aeration purposes. 5 Transport A lift truck is ...
-
Dimplex SI7MER - page 6
www.dimplex.de E-5 English 7.4 7 Installation 7.1 General Information The following con nections need to be established on the heat pump: Flow and return f low of the bri ne system Flow and return f low of the heat ing system Power supp ly 7.2 Heating System Connection ATTENTION! Flush the heating system prio r to connecting the heat pu ...
-
Dimplex SI7MER - page 7
E-6 English 8 8 Commissioning 8.1 General Information To ensure that start-up is performed correctly, it should only be carried out by an after-sales servic e technici an authorise d by the manufacturer. This ma y be a condi tion f or exten din g the guaran - tee (see Warrant y).Start-up should be carri ed out in heating op - eration . 8.2 Preparat ...
-
Dimplex SI7MER - page 8
www.dimplex.de E-7 English 11 9 Maintenance and Cleaning 9.1 Maintenance The heat pump is maintenan ce-free. To prevent faults due to sediment in the heat exchangers, care must be t aken to ensure that no impurities ca n enter either the heat source sys tem or the heating system. I n the event that operatin g malfunctions due to contamination occur ...
-
Dimplex SI7MER - page 9
E-8 English 12 12 Device Information 1 Type and order code SI 5MER SI 7MER SI 9MER SI 11MER 2D e s i g n 2.1 Model Reversible Reversible Reversible Reversible 2.2 Degree of protection according to EN 60 529 IP20 IP20 IP20 IP20 2.3 Installation location Indoors Indoors Indoo rs Indoors 3 Performanc e data 3.1 Operating temperature li mits: Heating w ...
-
Dimplex SI7MER - page 10
A-I Anhang · Ap pendix · Annexes Anhang / Appendix / Annexes 1 Maßbilder / Dimension Drawings / Schémas cotés .............................................................. ..... A-II 1.1 Maßbild / Dimension Drawing / Sc héma coté ............... ................. ................... ................ .................. .... A-II 2 Diagramme ...
-
Dimplex SI7MER - page 11
A-II Anhang · Ap pendix · Annexes 1 1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Maßbild / Dimension Drawing / Schéma coté :lUPHTXHOOH (LQJDQJLQ:3 ´ $XHQJHZLQGH +HDWVRXUFH +HDWSXPSLQOHW ´H[WHUQDOWKUHDG 6RXUFHGHFKDOHXU (QWUpHGDQVOD3 $& )LO ...
-
Dimplex SI7MER - page 12
A-III Anhang · Ap pendix · Annexes 2.1 2 Diagramme / Diagrams / Diagrammes 2.1 Heizbetrieb / Heating oper ation / Mode chauffage SI 5MER ? ...
-
Dimplex SI7MER - page 13
A-IV Anhang · Ap pendix · Annexes 2.2 2.2 Kühlbetrieb / Cooling operati on / Mode refroi dissement SI 5MER ? ...
-
Dimplex SI7MER - page 14
A-V Anhang · Ap pendix · Annexes 2.3 2.3 Heizbetrieb / Heating oper ation / Mode chauffage SI 7MER ...
-
Dimplex SI7MER - page 15
A-VI Anhang · Ap pendix · Annexes 2.4 2.4 Kühlbetrieb / Cooling operati on / Mode refroi dissement SI 7MER ...
-
Dimplex SI7MER - page 16
A-VII Anhang · Ap pendix · Annexes 2.5 2.5 Heizbetrieb / Heating oper ation / Mode chauffage SI 9MER ...
-
Dimplex SI7MER - page 17
A-VIII Anhang · Ap pendix · Annexes 2.6 2.6 Kühlbetrieb / Cooling operati on / Mode refroi dissement SI 9MER ? ...
-
Dimplex SI7MER - page 18
A-IX Anhang · Ap pendix · Annexes 2.7 2.7 Heizbetrieb / Heating oper ation / Mode chauffage SI 11MER ...
-
Dimplex SI7MER - page 19
A-X Anhang · Ap pendix · Annexes 2.8 2.8 Kühlbetrieb / Cooling operati on / Mode refroidissement SI 11MER ? ...
-
Dimplex SI7MER - page 20
A-XI Anhang · Ap pendix · Annexes 3.1 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung Standardregler / Contro l via the standa rd controller / Commande régu lateur standard 1HW]0DLQV5pVHDX ...
-
Dimplex SI7MER - page 21
A-XII Anhang · Ap pendix · Annexes 3.2 3.2 Steuerung Kühlregler / Control via the cooling controller / Commande régulateur refroidissement :HJH8PVFKDOWYHQWLO )RXUZDUHYHUVLQJYDOYH 6RXSDSHGHFRPPXWDWLRQYRLHV ...
-
Dimplex SI7MER - page 22
A-XIII Anhang · Ap pendix · Annexes 3.3 3.3 Last / Load / Charge 1HW]0DLQV5pVHDX ...
-
Dimplex SI7MER - page 23
A-XIV Anhang · Ap pendix · Annexes 3.4 3.4 Anschlussplan Standardregler / Terminal diagram for standard controller / Schéma de branchement du régulateur standard 1HW]0DLQV5pVHDX 1HW]/DVW0DLQV/RDG5pVHDX&KDUJH RGHUÂRUÂRX +HL]VWDE ,PPHUVLRQKHDWHU &DUWRXFKHFKDXIIDQWH ...
-
Dimplex SI7MER - page 24
A-XV Anhang · Ap pendix · Annexes 3.5 3.5 Anschlussplan Kühlregler / Termin al diagram for cooling controller / Schéma de branchement du ré gulateur de refroidis sement 7 HPSHU 7 HPS 7 HPS )HXFKWH +XPLGLW +XPLGLWp 7 HPSHU 7 HPS 7 HPS PD[6HQVRUHQ 0D[VHQVRUV FDSWHXUVPD ...
-
Dimplex SI7MER - page 25
A-XVI Anhang · Ap pendix · Annexes 3.6 3.6 Legende / Legend / Légende A1 Drahtbrücke, muss eingelegt werden, wenn kein Sperrschütz vorhande n ist Wire jumper, must be inserted if no blocking c on- tactor is fitted Le cavalier à fil doit être inséré en absence de dis- joncteur de blocage du fournisseur d' énergie. A2 Drahtbrücke, mus ...
-
Dimplex SI7MER - page 26
A-XVII Anhang · Ap pendix · Annexes 4.1 4 Hydraulisches Prinzips chema / Hydraulic Plumbing Diagram / Schéma hydraulique 4.1 Darstellung / Schemati c View / Représentation ...
-
Dimplex SI7MER - page 27
A-XVIII Anhang · Ap pendix · Annexes 4.2 4.2 Legende / Legend / Légende Absperrventil Shutoff val ve Robinet d’arrêt Absperrventil mit Entwässerung Shutoff valve with drainage Robinet d’arrêt avec écoulement Sicherheitsventi l Saf ety valve Vanne de sécurité Umwälzpumpe Circulati ng pump Circulateur Ausdehnungsgefäß Expansion vessel ...
-
Dimplex SI7MER - page 28
A-XIX Anhang · Ap pendix · Annexes 5 5 Konformitätserklärung / D e claration of Conformity / Déclaration de conformité ...
-
Dimplex SI7MER - page 29
Glen Dimplex Deutschl and GmbH Geschäftsbereich Di mplex Am Goldenen Feld 18 D-95326 Kulmbach Irrtümer und Änderungen vorbehalten. Subject to a lterations and errors. Sous réserve d’erreurs et modifications. +49 (0) 9221 709 565 www.dimplex.de ...
¿Tienes una pregunta acerca de Dimplex SI7MER?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Dimplex SI7MER, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Dimplex SI7MER probablemente compartirá una forma de solucionarlo.