  • Weil-McLain WGO - page 1

    WGO, WTGO and SGO-W WGO, WTGO and SGO-W WGO, WTGO and SGO-W WGO, WTGO and SGO-W WGO, WTGO and SGO-W Series 3 Series 3 Series 3 Series 3 Series 3 Oil-Fir Oil-Fir Oil-Fir Oil-Fir Oil-Fir ed W ed W ed W ed W ed W ater Boilers ater Boilers ater Boilers ater Boilers ater Boilers Part No. 550-141-828/1202 Part No. 550-141-828/1202 Part No. 550-141-828/12 ...

  • Weil-McLain WGO - page 2

    2 Hazard Definitions Following terms are used to bring attention to the presence of hazards of various risk levels, or to important information concerning product life. Indicates presence of hazards that will cause severe personal injury, death or substantial property damage if ignored. Indicates presence of hazards that can cause severe personal i ...

  • Weil-McLain WGO - page 3

    3 F or Y our Saf ety Follow instructions below to prevent severe personal injury, death or substan- tial property damage: Do not use crankcase drainings or any oil containing gasoline. See burner manual for proper fuel oil. Do not attempt to start burner when excess oil has accumulated in combustion chamber, when unit is full of vapor, or when comb ...

  • Weil-McLain WGO - page 4

    4 Routine Maintenance Schedule The schedule belo w is specifically designed for the homeo wner . Please read pa ges 2 and 3 bef ore pr oceeding. Beginning each heating season: Call a qualified service technician to perform annual service. Daily during heating season: Check that boiler area is free from combusti- ble materials, gasoline and other fl ...

  • Weil-McLain WGO - page 5

    5 Star t-up WGO/WTGO (see Figure 1): 1. If burner does not fire , check for: Service switch on boiler or additional switches turned off. Fuses or breaker switch tripped. Thermostat set below room temperature. Fuel valves turned off. Not enough oil in tank to supply burner. DANGE R WGO and WTGO Boiler s Figure 1 2. Correct problems found in step #1. ...

  • Weil-McLain WGO - page 6

    6 Star t-up SGO-W Boiler Figure 2 2. Correct problems found in step #1. If burner does not fire, press reset button on burner primary control only once. Repeated presses will deposit oil in combustion chamber. Burner must never be fired when oil is in combustion chamber. Immedi- ately call qualified service technician. 3. If burner still does not f ...

  • Weil-McLain WGO - page 7

    7 The problems and corrections above represent common situations that can occur. There may be others not listed above. It is important always to contact a qualified service techni- cian if you have any questions about the operation of your boiler or system. COMMON PROBLEMS COMMON CAUSES POSSIBLE CORRECTIONS Rapid cycling - burner turns on and off f ...

  • Weil-McLain WGO - page 8

    8 The pr ocedures and inf ormation on pag es 7 thr ough 11 ar e intended only f or a qualified ser vice technician who has the necessar y equipment to inspect and adjust boiler and burner . A homeo wner should ne ver attempt these pr ocedur es. Qualified ser vice technician must r ead pa ges 2 and 3 befor e proceeding. Annual Ser vice Check List An ...

  • Weil-McLain WGO - page 9

    9 Cleaning Boiler Flueways Figure 3 Thoroughly clean flueways between all pins at all angles. Start on top of boiler, finish from the bottom. Detailed Ser vice Pr ocedur es Cleaning boiler flueways: Make sure all electrical connections to boiler are turned off and wait until boiler is warm, not hot, before cleaning. Failure to do so will result in ...

  • Weil-McLain WGO - page 10

    10 Fill the system: 1. Close manual and automatic air vents and drain cock. 2. Fill to correct system pressure. Correct pres- sure will vary with each installation. Normal cold water fill pressure for residential systems is 12 psig. Boiler water pH 7.0 to 8.5 is recom- mended. Failure to maintain recom- mended pH level can cause section failure and ...

  • Weil-McLain WGO - page 11

    11 Detailed Ser vice Pr ocedur es Controls requiring annual service: WATER RELIEF VALVE: Check operation of water relief valve. Follow instructions on label fastened to relief valve. Scald potential. Do not check operation of relief valve unless discharge piping has been installed according to Boiler Manual. If piping is not in place, a qualified s ...

  • Weil-McLain WGO - page 12

    12 Part No. 550-141-828/1202 ...

Fabricante Weil-McLain Categoría Boiler

Los documentos del dispositivo Weil-McLain WGO que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Weil-McLain
- manuales de instrucciones WGO
- hojas de producto Weil-McLain
- folletos informativos
- o etiquetas energéticas Weil-McLain WGO
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Weil-McLain WGO.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Weil-McLain WGO, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Weil-McLain WGO. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Weil-McLain WGO.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Weil-McLain WGO, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Weil-McLain WGO. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Weil-McLain WGO.

El manual de instrucciones completo de Weil-McLain debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Weil-McLain WGO - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Weil-McLain WGO, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Weil-McLain WGO que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Weil-McLain WGO - que deben facilitarnos los primeros pasos durante el uso de Weil-McLain WGO
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Weil-McLain WGO
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Weil-McLain WGO en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Weil-McLain WGO?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Weil-McLain WGO, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Weil-McLain WGO probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)