    CITY MUL TI Control System Smart ME Controller P AR-U02MEDA Installation Manual Prior to use, thoroughly read the instructions in this manual to use the product correctly . Retain this manual for future reference. Make sure that the CD-ROM, this manual, and Simple Operation Manual are passed on to any future users. T o ensure safety and proper oper ...

  • Mitsubishi Electronics PAR-U02MEDA - page 2

    – 1 – Chapter 1. Inst allation This installation manual describes how to install the Smart ME Controller for use with Mitsubishi Building Air Conditioning System, di rect expansion type CITY MUL TI air conditioner indoor units (“-A” type and later). Please be sure to read this installation manual and Inst ruction Book that a re supplied wit ...

  • Mitsubishi Electronics PAR-U02MEDA - page 3

    – 2 – CAUTION W ARNING CAUTION W ARNING CAUTION Precautions du ring inst allation Precautions du ring wiring T o re duce the risk of fire or explosion, do not place flammable materials or use flammabl e sprays around the controller . T o reduce th e risk of damage to the controller , do not directly spray insecticide or other flammable sprays o ...

  • Mitsubishi Electronics PAR-U02MEDA - page 4

    – 3 – W ARNING CAUTION The CD-ROM that is supplied with Smart ME Controller The CD-ROM that is supplied with the Smart ME Co ntroller contains an Installation Manual and Instruction Book. Each document is in PDF format. Viewing documents requires a computer with Adobe ® Reader ® or Adobe ® Acrobat ® installed. Precautions for moving or rep ...

  • Mitsubishi Electronics PAR-U02MEDA - page 5

    – 4 – The following parts are included in the box. (1) Field-supplied part s (2) Required to ols • Flat-tip screwdriver (Width: 4-5.5 mm (5/32-7/32 in)) • Knife or nipper • Miscellaneous tools 2 Component names and supplied pa rt s *1 The front cover is already installe d on the top case at factory shipment. *2 ISO metric screw thread *3 ...

  • Mitsubishi Electronics PAR-U02MEDA - page 6

    – 5 – *1 The power consumption coef ticient of the Smart ME C ontroller is “0.5” and that of a ME Remote Controller (P AR-F27MEA) is “0.25”. If the number of Sma rt ME Controllers is high and t he to tal power supply t hey require exceeds the out door unit's ability to supply power , a Transmission booster (P AC-SF46EP A) will be r ...

  • Mitsubishi Electronics PAR-U02MEDA - page 7

    – 6 – This remote controller is for the wall installation. It can be installed either in the switch box or directly on the wall. When performing direct wall installati on, cables can be thread through either back or top of the remote controller . (1) Selecting an installation site Install the remote controller (switch box) on t he site where th ...

  • Mitsubishi Electronics PAR-U02MEDA - page 8

    – 7 – Occupancy sensor detects occu pancy based on the temperature difference between the occupant and its surroundings. T o be precise, to enhance the sensitivity o f the sensor to occupant movements, the occupancy sensor is designed to detect the c hanges in the amount of infrared light emitted from a n object in the detection zone, including ...

  • Mitsubishi Electronics PAR-U02MEDA - page 9

    – 8 – (2) Installation sp ace Leave a space around the remote controller as show n in the figur e below , regardless of whe ther the controller is installed in the switch box or direct ly on the wall. Removing the remote co ntroller will not be easy with insufficient space. Also, leave an operating space in fr ont of the remote controller. (3) ...

  • Mitsubishi Electronics PAR-U02MEDA - page 10

    – 9 – • Cut out the thin-wall part on the cover (indicated with the shaded area in the right figure) with a knife or a nipper. Note: Make sure that the hole edges are smooth and will not damage the wires. 4 Install the bottom case. • Remove the sheath as shown in the figure at right, and route the remote controller cable behind the bottom c ...

  • Mitsubishi Electronics PAR-U02MEDA - page 11

    – 10 – 6 Connect the remot e controller cable to the terminal block on the top case. Connect the remote controller cable to the terminal block. * T ake the follo wing procedure only when performing direct wall installation and drilling a hole in the wall. • Seal the hole through which the cable is threaded with putty . Connec t the cabl e to ...

  • Mitsubishi Electronics PAR-U02MEDA - page 12

    – 11 – 7 Set the M-NET addresses. * The factory setting for the rotary switches is 01. ** M-NET address can be changed with or without the power being app lied to the controller . The screen will jump to the [St art-up] screen. Group information for indoor units and AHC units will be deleted, but the rest of the information will be retained. 8 ...

  • Mitsubishi Electronics PAR-U02MEDA - page 13

    – 12 – ■ Direct wall installation (when running the cable along the wall) • Thread the cable through the access hole at the top of the remote controller . • Seal the cut-out part of the cover with putty . • Use a cable cover . Installation is complete. Follow the instructions below when uninstalling them. • Uninstalling the front cove ...

  • Mitsubishi Electronics PAR-U02MEDA - page 14

    – 13 – ■ Discrepancy between the room temperature measured at the wall and the actua l room temperature may occur. If the following conditions are met, the use of the temperature sensor on the indoor unit is recommended. • Air distribution in the space is poor . • There is a great discrepancy between the wall temperature an d the actual r ...

  • Mitsubishi Electronics PAR-U02MEDA - page 15

    – 14 – Chapter 2. Initial Setting This chapter contains information about the settings to be made at the time of installation. Please read the instructions carefully and make the se ttings accordi ngly . Refer to Chapter 1 “ Installation” for how to install the Remote Controller , and refer to the ai r condition ing unit installation manual ...

  • Mitsubishi Electronics PAR-U02MEDA - page 16

    – 15 – (2) Setup screen After completing the settings, touch the [Back] button on the [Setup] screen. Th e message “Collecting the information from the air conditioner .” will appear , and then the screen w ill jump to the HOME screen. This signals the completion of the setup pro cess. Access the Service Menu from the HOME screen to ma ke t ...

  • Mitsubishi Electronics PAR-U02MEDA - page 17

    – 16 – A password is required to access the Menu ( Service ) screen or some settings under the Menu ( User ) screen . • The initial Service password is “9999.” The initial User password is “0000.” Chan ge the password as necessary to prevent unauthorized access. • Make sure the password is available to the maintenance and other nece ...

  • Mitsubishi Electronics PAR-U02MEDA - page 18

    – 17 – *1 This setting will not become effective if the te mperature sensor on the indoor unit is activated. *2 The LED indicates the operation status of air conditi oning unit s in colors. Refer to "LED Indicator" in the instructions book. *3 All settings information will be cleared to the default. *4 AHC port name will not appear if ...

  • Mitsubishi Electronics PAR-U02MEDA - page 19

    – 18 – (1) Setup menu (a) Group setting Refer to section 1 "Initial Settings" (2) "Setup screen". (b) LOSSNA Y interlock Refer to section 1 "Initial Settings" (2) "Setup screen". (c) Search connection information Refer to section 1 "Initial Settings" (2) "Setup screen". (d) Cool/Heat d ...

  • Mitsubishi Electronics PAR-U02MEDA - page 20

    – 19 – (h) T elephone number (i) IC function setting 1 Select the indoor unit address in the [M-NET address] field. (When [Grp] has been selected, all the indoor units that are controlled from the controller will be selected.) 2 Select the desired function number in the [Function number] field. 3 T ouch the [Conf] button to confirm the current ...

  • Mitsubishi Electronics PAR-U02MEDA - page 21

    – 20 – (k) Reset RC (l) AHC port name (2) Error Menu (a) Self check (max. 20 characters) WT06829X02.book Pag e 20 Wednesday, June 26, 2013 4:03 P M ...

  • Mitsubishi Electronics PAR-U02MEDA - page 22

    – 21 – (a) Read the section about T est run in the indoor unit Installation Manual before performing a test run. (b) During the test run, indoor units will be forced to operate in t he Thermo-ON status. Except the set temperature, normal operation functions are accessible during test ru n. (c) By selecting the address of another indoor unit, th ...

  • Mitsubishi Electronics PAR-U02MEDA - page 23

    – 22 – *1 Not for use w ith a generic DC power supply device. *2 “Power consumption coefficient” is a coefficient to calculate the relative power consumption of the devices that receive power th rough the M-NET transmission cable. Refer to section 4 “System diagram” in Chapter 1 in this Manual. Specifi cations Power Source 17-32 VDC *1 ...

  • Mitsubishi Electronics PAR-U02MEDA - page 24

    Please be sure to put the cont act address/telephone number on this manual before hand i ng it to the customer . This product is designed and inte nded for use in the residential, commercial and light-industrial envir onment. The product at hand is based on the following EU regulations: • Electromagnetic Compatibilit y Directive 2004/108/EC • R ...

Fabricante Mitsubishi Electronics Categoría Fan

Los documentos del dispositivo Mitsubishi Electronics PAR-U02MEDA que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Mitsubishi Electronics
- manuales de instrucciones PAR-U02MEDA
- hojas de producto Mitsubishi Electronics
- folletos informativos
- o etiquetas energéticas Mitsubishi Electronics PAR-U02MEDA
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Mitsubishi Electronics PAR-U02MEDA.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Mitsubishi Electronics PAR-U02MEDA, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Mitsubishi Electronics PAR-U02MEDA. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Mitsubishi Electronics PAR-U02MEDA.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Mitsubishi Electronics PAR-U02MEDA, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Mitsubishi Electronics PAR-U02MEDA. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Mitsubishi Electronics PAR-U02MEDA.

El manual de instrucciones completo de Mitsubishi Electronics debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Mitsubishi Electronics PAR-U02MEDA - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Mitsubishi Electronics PAR-U02MEDA, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Mitsubishi Electronics PAR-U02MEDA que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Mitsubishi Electronics PAR-U02MEDA - que deben facilitarnos los primeros pasos durante el uso de Mitsubishi Electronics PAR-U02MEDA
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Mitsubishi Electronics PAR-U02MEDA
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Mitsubishi Electronics PAR-U02MEDA en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Mitsubishi Electronics PAR-U02MEDA?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Mitsubishi Electronics PAR-U02MEDA, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Mitsubishi Electronics PAR-U02MEDA probablemente compartirá una forma de solucionarlo.