    Conductivity/Resistivity SERIES Sensors MAKCHESlEfl.UK CDE68 1 STAMFORO.CT info@omega. cor n wwbv.omega.cum e-mail: (omega.com@j Shop online at ...

  • Omega Engineering CDE681 - page 2

    EMC / EM I regu l a ti ons t ha t app l y . OMEGA i s cons tantly pursuing certification of its products to the European Ne w App roach D ir ec ti ves . OMEGA w ill add t he CE m ark to every appropr i a te dev i ce upon ce rtifi ca ti on . The i n f o r m a ti on con tained in this docu m en t i s be li eved t o be co rr ec t, bu t OMEGA E ng i ne ...

  • Omega Engineering CDE681 - page 3

    i purpdse is to alert the user of this sensor to important operating information. .- HELPFUL IDENTIFIERS In addition to information on installation and operation, this instruction manual may contain WARNINGS pertaining to user safety, CAUTIONS regarding possible sensor malfunction, and NOTES on important, useful operating guidelines. A warning look ...

  • Omega Engineering CDE681 - page 4

    12 I_ ii f Section 1 Recommended Cleaning Procedure . . . . . . . . . . . . ..*........................... 10 Section 2 Troubleshooting 2.1 Checking Sensor Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.2 Customer Assistance . . . . . . . . . . . . . . . ...

  • Omega Engineering CDE681 - page 5

    :I R ounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 2-4 Immersion Mounting Details ........................................................ 6 Figure 2-5 Interconnect Cable Termination Details .......................... ...

  • Omega Engineering CDE681 - page 6

    . ‘ I ’ NOTES: Conductivity/Resistivity Sensors f-t-? CDE68 1 Series 2:14 PM Pageiv 7/17/03 M3594-0603-CDE681Series.qxd f ...

  • Omega Engineering CDE681 - page 7

    0.05,0.5,1.0,5.0, or 10. Installation Style: For sensors with a 0.05 cell constant, use K-inch or %-inch male NPT compression fittings made of Kynar (PVDF) or 316 stainless steel. For sensors with any other cell constant, use a %-inch male NPT compression fitting made of Kynar or 316 stainless steel. In all cases, the fitting enables the sensor to ...

  • Omega Engineering CDE681 - page 8

    2 I_ % NPT % NPT % NPT - % NPT % NPT ( Compression Material K yna r ( PVDF ) 316SS K yna r 316SS K yna r 316SS K yna r 316SS K yna r 316SS Fitting Thread CDE681 - E - S 1 1 CDE681 - E - K 10 . 0 I CDE681 -D-S . Model No. CDE681 - A - K CDE681 - A - S CDE681 - B - K CDE681 - B - S CDE681 - C - K CDE681 - C - S Cell Constant 0 . 05 0 . 5 1 .0 CDE681 ...

  • Omega Engineering CDE681 - page 9

    ( TEMP+ ) BLUE ( TEMP -) CLEAR (I NNER SH I ELD ) Figure 2-l. General Dimensions and Cable Wire Details Insertion Mounting To ensure optimum measurement performance, follow these guidelines when insertion mounting the sensor: ?? Install the sensor into the pipe run so that the process flows directly into the end of the sensor (see Figure 2-2). ?? P ...

  • Omega Engineering CDE681 - page 10

    4 4 ontoXe 2-3 to get an effective seal. sensor as shown in Figure I Correctly orient the ferrule ’ I comtxession nut first. comoression nut and ferrule onto the sensor. u FLOW Figure 2-2. Insertion Mounting Details 2. Remove the compression fitting from the sensor and screw it into the pipe tee (or reducer, if used). 3. Electrically connect sens ...

  • Omega Engineering CDE681 - page 11

    its “cross-flow” holes with the exiting process flow path as shown in Figure 2-3. After tightening the compression nut, the ferrule will be permanently crimped. Therefore, make sure that the sensor is inserted to the proper depth before tightening the compression nut. C. With the sensor properly positioned, tighten the compression nut onto the ...

  • Omega Engineering CDE681 - page 12

    .:/ Figure 2-4. Immersion Mounting Details I_ 3 / 4 I NCH CO MPRESS I ON F I TT I NG SE NSOR l/ 2 I NCH X 1 I NCH NP T REDUCER 3 / 4 I NCH X 3 , 4 I NCH OR l/ 2 I NCH X 1 88 . 9 T O 139 . 7 ( 3 . 50 T O 5 . 50 ) SE NSOR EXTE NS I ON 1 I NCH N PT COU PL I NG ( CUS TOMER PROV I DED ) I I I D I MENS I ON S mm ( I ” .) 3 / 4 OR / _ . I + - + -: 1 I N ...

  • Omega Engineering CDE681 - page 13

    :I P Teflon tape may not be adequate.) 4. Fasten a Unilet junction box onto the other end of the pipe. 5. Run interconnect cable from the analyzer into the Unilet junction box. Connect the sensor and interconnect cable wires, by matching colors, to the terminals in the junction box. Fasten the cover onto the junction box. 6. Electrically connect th ...

  • Omega Engineering CDE681 - page 14

    i Be careful not to damage the exposed section of the cellophane binder. I_ _ !4 inch of the outer cable jacket and outer shield foil. - one shielding the signal, and one shielding the overall cable. These specific cable characteristics protect the measurement signal from electromagnetic interference. Using a cable with different construction may i ...

  • Omega Engineering CDE681 - page 15

    -) I NN ER SH I ELD To Analyzer: Refer to the instrument instruction manual and connect the interconnect cable wires to appropriate SENSOR terminals in the same way as the sensor wires would be directly connected. 9 ( TE MP S t uE + ) SH I ELD RED ( DR I VE ) BLACK ( SENSE ) W H I TE ( TE M P L6.41 SE NSOR T yp _ 0 . 25 FO I L Figure 2-5. Interconn ...

  • Omega Engineering CDE681 - page 16

    I 10 I_ - RECOMMENDED CLEANING PROCEDURE Keep the sensor reasonably clean to maintain measurement accuracy. The time between cleanings (days, weeks, etc.) is affected by the characteristics of the process solution and can only be determined by operating experience. 1. 2. 3. 4. 5. 6. Remove most contaminate buildup by carefully wiping the inner elec ...

  • Omega Engineering CDE681 - page 17

    3 I_ 5 ohms Between black wire and inner electrode Less than 5 ohms Between black and red wires Infinite (open circuit) Between black and white wires Between red and white wires Infinite (open circuit) Infinite (open circuit) Between red and inner shield wires Infinite (open circuit) Between black and inner shield wires Infinite (open circuit) Betw ...

  • Omega Engineering CDE681 - page 18

    li 12 V I_ email: info at omega.com All sensors returned for repair or replacement must be freight prepaid and include the following information: 1. A clearly written description of the malfunction. 2. Name of person to contact and the phone number where they can be reached. 3. Proper return address for shipping sensor(s) back. Include preferred sh ...

  • Omega Engineering CDE681 - page 19

    0 Copyright 2003 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC. f The pu r chase r i s r espons i b l e f o r sh i pp i ng cha r ge s , f ...

  • Omega Engineering CDE681 - page 20

    M3594/0603 & Dissolved Oxygen Instruments pH, Conductivity w & Wastewater Treatment m Industrial Water & Water Monitors m Air, Soil & Tubing m Pumps m Refractometers & Control Instrumentation m Metering m Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL 0 ’ Flexible Heaters & Band Heaters B Immersion & Strip Hea ...

Fabricante Omega Engineering Categoría Stud Sensor

Los documentos del dispositivo Omega Engineering CDE681 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Omega Engineering
- manuales de instrucciones CDE681
- hojas de producto Omega Engineering
- folletos informativos
- o etiquetas energéticas Omega Engineering CDE681
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Omega Engineering CDE681.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Omega Engineering CDE681, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Omega Engineering CDE681. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Omega Engineering CDE681.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Omega Engineering CDE681, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Omega Engineering CDE681. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Omega Engineering CDE681.

El manual de instrucciones completo de Omega Engineering debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Omega Engineering CDE681 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Omega Engineering CDE681, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Omega Engineering CDE681 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Omega Engineering CDE681 - que deben facilitarnos los primeros pasos durante el uso de Omega Engineering CDE681
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Omega Engineering CDE681
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Omega Engineering CDE681 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Omega Engineering CDE681?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Omega Engineering CDE681, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Omega Engineering CDE681 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)