    WTI Part No.: 13619 Rev . A IPS-800CE-D16 & IPS-1600CE-D16 Internet Power Switches User ’s Guide ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 2

    ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 3

    i Warnings and Cautions: INST ALL ATION INSTRUCTIONS SECURE RACKING If Secure Racked units are installed in a closed or multi-unit rack assembly , they may require further evaluation by Certification Agencies. The following items must be considered. 1. The ambient within the rack may be greater than room ambient. Installation should be such that t ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 4

    ii IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide EMC, Safety , and R&T TE Directive Compliance The CE mark is affixed to this product to confirm compliance with the following European Community Directives: • Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member States relating to electromagnetic compa ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 5

    i T able of Contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 2. Unit Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 3. Quick Start . . . . . . . . . . . . . . . . . . . . . . ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 6

    ii IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide Appendices: A. Interface Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1 A.1. Serial COM / RS232 Port Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1 B. Specifications . . . . . . . . . . ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 7

    1-1 1. Introduction Electronic equipment sometimes "locks-up," requiring a service call just to flip the power switch to perform a simple reboot. The IPS-800CE-D16 and IPS-1600CE-D16 Series Internet Power Switches give you the ability to perform this function from anywhere, just point your browser to the IPS’ s IP address, enter the se ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 8

    1-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide IPS-800CE-D16 and IPS -1600CE-D16 Units This User ’ s Guide discusses both the IPS-800CE-D16 and IPS-1600CE- D16 Internet Power Switches. Throughout this User’ s Guide, both units are referred to as the "IPS". The input voltages, maximum loads and the number of output plugs per ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 9

    2-1 2. Unit Description As shown in Figure 2.1 and Figure 2.2, the IPS back panel includes connectors, LEDs and manual controls described below: BUS A B A-1 A-2 A-3 A-4 B-5 B-6 B-7 B-8 MAIN POWER COM 10BaseT ACT RDY ON DEF 1 2 3 4 5 6 7 8 9 Figur e 2.1: IPS-800CE-D16 Back Panel (8-Plug Unit) ➀ Bus "A" Power Inlet and Cir cuit Breaker: A ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 10

    2-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide ➃ Bus "B" Switched Plugs and Plug Indicators: AC Outlets that can be switched On, Off or rebooted in response to user commands. Includes same components listed in item 3 above. ➄ Default Button: This button can be used to either reset the unit to default parameters or manually ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 11

    3-1 3. Quick Start This Quick Start Guide describes a simplified installation procedure for the IPS-800CE-D16 (8-Plugs) and the IPS-1600CE-D16 (16-Plugs) hardware, which will allow you to communicate with the unit in order to demonstrate basic features and check for proper operation. Note that this Quick Start Guide does not provide a detailed des ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 12

    3-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 3.1.2. Connect your PC to the IPS The IPS can either be controlled by a local PC, that communicates with the unit via cable, controlled via external modem, or controlled via TCP/IP network. In order to switch plugs or select parameters, commands are issued to the IPS via either the Network P ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 13

    3-3 Quick Start Figur e 3.1: Plug Status Screen - W eb Br owser Interface (Model IPS-800CE-D16 Shown) Internet Power Switch v1.41h Site ID: (undefined) Plug | Name | Password | Status | Boot/Seq. Delay | Default | -----+------------------+-------------+--------+-----------------+---------+ 1 | (undefined) | (undefined) | ON | 0.5 Secs | ON | 2 | ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 14

    3-4 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide iii. V ia Modem: Use your communications program to dial the number for the phone line which is connected to your external modem. Note that in order to communicate with the unit via modem, you must first access the command mode via Network or Local PC, and use the Serial Parameters Menu to ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 15

    4-1 4. Installation This Section provides further details regarding installation of the IPS unit. 4.1. Power Supply Connection Connect the IPS unit to an appropriate power supply . Note that the IPS’ s Main Power switch must be "On" in order for the unit to operate. CAUTIONS: • Befor e attempting to install this unit, please review th ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 16

    4-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 4. Connect the power cables to the power inlets. Check to make sure that both cables are firmly seated in the power inlet connectors. 5. Align the power cables with the two notches in the top of the slider plate, and then move the slider plate forward until both cables are held firmly in p ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 17

    4-3 Installation 4.3.1. Connecting a Local PC Use the supplied null modem cable to connect your PC COM port to the IPS COM (RS232 Port.) Make certain that the Serial Port Mode is set to "Console" as described in Section 5.3.1. 4.3.2. Connecting an External Modem When connecting directly to an external modem, use a standard A T to Modem ca ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 18

    4-4 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 19

    5-1 5. Configuration 5.1. System Mode and User Mode In order to restrict access to sensitive command functions, the IPS features two operating modes; System Mode and User Mode. • System Mode: Allows access to all configuration menus, switching functions and status screens. The System Mode Status Screens show On/Off conditions for all switched ou ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 20

    5-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 5.2. Communicating with the IPS In order to configure the unit or invoke command functions, you must first connect to the IPS and access command mode. As discussed in Section 3, the IPS offers two separate command interfaces: the W eb Browser Interface, and the T ext Interface. The IPS als ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 21

    5-3 Confi guration 3. Password Prompt: The IPS will display a prompt, which asks for your name and password. a) User Name: If you have not previously defined a user name, then this field should be left blank. A user name is only required when one has been defined via the General Parameters menu. b) Password: Key in your System Password or Plug ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 22

    5-4 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide c) Via Network: The IPS includes a default IP address (192.168.168.168), which allows you to contact the unit from any network node on the same subnet. When the IPS is installed in a working network environment, it is recommended to redefine the IP Address, Subnet Mask, and Gateway Address ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 23

    5-5 Confi guration 5.3. Configuration Menus As described in the sections that follow , configuration parameters for the IPS can be selected via the W eb Browser Interface or T ext Interface. Although the W eb Browser and T ext Interface provide two separate means for selecting parameters, both interfaces allow access to essentially the same set o ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 24

    5-6 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 5.3.1. The General Parameters Menus The General Parameters Menus allow you to select parameters such as the System Password, User Name, Site I.D. and other options. • W eb Browser Interface: Click the "Setup" button to access the Setup Menus, and then click the "General Para ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 25

    5-7 Confi guration • User Name: (Optional) The User Name allows you to set up an additional layer of security for web access to command mode by requiring that users correctly enter a name in addition to a password. Note that the User Name is only required when the unit is accessed via the W eb Browser Interface. (Four to 16 Characters, Default = ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 26

    5-8 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide • Inactivity Timeout: Determines how long the IPS will wait for additional commands during periods of inactivity . When the Timeout Period elapses, the user will be disconnected from the IPS command mode. (Default = 2 Minutes.) • Command Confirmation: When enabled, the IPS will display ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 27

    5-9 Confi guration 5.3.2. The Serial Parameters Menu The Serial Parameters Menus are used to configure the IPS's serial COM Port, and allow you to select parameters such as the Baud Rate, Parity and Modem Initialization String. T o access the Serial Parameters Menu, proceed as follows: • W eb Browser Interface: Click the "Setup" ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 28

    5-10 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide As shown in Figure 5.5 and Figure 5.6, the Serial Parameters Menus allow you to define the following parameters: • Baud Rate: Baud Rate for the IPS COM Port. (Default = 9600 bps.) Note: When this setting is changed, the new baud rate will not be applied until the user exits and then re-e ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 29

    5-11 Confi guration 5.3.3. Plug Parameters Menus The Plug Parameters Menus are used to define Plug Names, Plug Passwords, boot/sequence delay times and Power Up Default values for each of the IPS’ s Switched AC Outlets. • W eb Browser Interface: Click the "Setup" button to access the configuration menus, then click the "Plug P ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 30

    5-12 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide The Plug Parameters Menu allows you to define the following parameters: • Plug Name: (Up to 16 Characters, Default = undefined.) Note: Plug Names cannot begin with a number , dash ( - ), underscore character ( _ ), forward slash character ( / ) or backslash ( ) character , and cannot ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 31

    5-13 Confi guration 5.3.3.2. The Boot / Sequence Delay Period. The Boot / Sequence Delay value will be applied differently for Reboot operations as opposed to simple On/Off operations as described below: 1. Reboot Cycles: a) Single Plug: The Boot/Seq. Delay determines how long the plug will remain Off before it is switched back On again. b) Severa ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 32

    5-14 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide Figur e 5.9: Network Parameters Menu - W eb Br owser Interface NETWORK PARAMETERS: 1. IP Address: 192.168.168.168 2. Subnet Mask: 255.255.255.0 3. Gateway Address: (undefined) 4. Send MSS: 536 5. IP Security MAC Address: 00-09-9b-00-a0-32 Enter Selection, Press <ESC> to Exit ... Figu ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 33

    5-15 Confi guration 5.3.4. Network Parameters Menus The Network Parameters Menus are used to select the IP Address and other network parameters. • W eb Browser Interface: Click the "Setup" button to access the Setup Menus, and then click the "Network Parameters" button. The Network Parameters Menu will be displayed as shown i ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 34

    5-16 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 5.3.4.1. IP Security Feature The IP Security feature can be used to restrict unauthorized IP addresses from establishing a connection with the IPS. In the default state, the IPS accepts incoming IP connections from all hosts. T o configure the IP Security feature, proceed as follows: 1. Ac ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 35

    5-17 Confi guration Example 1: Deny access to all hosts except 192.1.1.5: Security Mask #1: 255.255.255.255 Mask #1 Action: Deny Security Mask #2: 192.1.1.5 Mask #2 Action: Permit Since 255 is a wild card, Mask #1 blocks all IP Addresses. Mask #2 then specifically grants access to 192.1.1.5 only . Example 2: Allow access only by addresses that be ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 36

    5-18 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 5.3.5. The T elnet Parameters Menus The T elnet Parameters Menus are used to enable/disable T elnet access to the IPS command mode and select the TCP port for T elnet connections. • W eb Browser Interface: Click the "Setup" button to access the configuration menus, and then cli ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 37

    5-19 Confi guration Figur e 5.14: W eb Server Parameters Menu - W eb Br owser Interface WEB SERVER: 1. Service: On 2. Server Port #: 80 Enter Selection, Press <ESC> to Exit ... Figur e 5.15: W eb Server Parameters Menu - T ext Interface 5.3.6. Web Server Parameters Menus The W eb Server Parameters Menus are used to configure the internal we ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 38

    5-20 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 5.4. Save Configuration Parameters The IPS offers two methods for saving parameters; Saving to Memory , and Saving to an ASCII File. Saving parameters to memory ensures that your user-defined configuration will remain intact if power to the IPS is temporarily interrupted. After the confi ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 39

    6-1 6. Operation As discussed in Section 5, the IPS offers two separate command interfaces; the W eb Browser Interface and the T ext Interface. Note that Both interfaces offer essentially the same command options and features, and that parameters defined via the W eb Interface will also apply when communicating via the T ext Interface (and vice ve ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 40

    6-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 3. Switching Plugs On: Click the "On" radio button next to the desired plug(s), then click "Apply". T o switch all Plugs On, click the "On" radio button in the "All Plugs" row , then Click "Apply ." 4. Switching Plugs Off: Click the "Off ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 41

    6-3 Operation 6.2. Operation via the T ext Interface When using the T ext Interface, all switching functions are performed by invoking simple, ASCII commands. ASCII commands are also used to display status screens and to log out of command mode. The T ext Interface includes a Help Menu, which summarizes all available IPS commands. T o display the T ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 42

    6-4 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 6.2.2. Switching and Reboot Commands - T ext Interface These commands can be used to switch or reboot the IPS’ s switched plugs, and can also be used to set plugs to the user-defined Power -Up Default values. Plugs may be specified by name or number . Notes: • W ait for the "IPS&g ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 43

    6-5 Operation T o Switch Plugs, or initiate a Boot Cycle, proceed as follows: 1. Switch Plug(s) On: T o power-on a plug, type /ON n and press [Enter]. Where " n " is the number or name of the desired plug. For example: /ON 1 or /ON ROUTER 2. Switch Plug(s) Off: T o power-off a plug, type /OFF n and press [Enter] . Where " n " is ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 44

    6-6 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 6.2.3. Applying Commands to Several Plugs - T ext Interface As described below , switching and reboot commands can be applied to only one Switched AC Outlet, or to an assortment of outlets. Note: When switching and reboot operations are initiated, Boot/ Sequence Delay times will be applied a ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 45

    6-7 Operation 6.4. The Automated Mode The Automated Mode allows the IPS to execute switching and reboot commands, without displaying menus or generating response messages. Automated Mode is designed to allow the IPS to be controlled by a device which can generate commands to control power switching functions without human intervention. When Automat ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 46

    6-8 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 3. "Sure?" Pr ompt Suppressed: All commands are executed without prompting for user confirmation. 4. Error Messages Suppressed: If the [Enter] key is pressed without entering a command, the IPS will not respond with the "Invalid Command" message. Note however , that an e ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 47

    7-1 7. Saving and Restoring Configuration P arameters After the IPS has been properly configured, parameters can be downloaded and saved as an ASCII text file on your local or remote PC. Later, if the configuration is accidentally altered, the file with the saved parameters can be uploaded to automatically reconfigure the unit without the need ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 48

    7-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 7.2. Restoring Saved P arameters This Section describes the procedure for using your communications program to send saved parameters to the IPS. Note: Parameters saved to an ASCII file can only be restored via the T ext Interface. This procedure cannot be performed via the W eb Browser Inte ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 49

    8-1 8. Upgrading the IPS Firmware When new , improved versions of the IPS firmware become available, the "Upgrade Firmware" function can be used to update the unit. Updates can be installed via the Console Port or Network Port. Notes: • The upgrade procedure can only be performed via the T ext Interface. • All other network ports wil ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 50

    8-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide 4. Set your communication program for ASCII Mode, then use the program’ s “Send File” function to transfer the upgrade file to the IPS. Select ASCII format, then specify the filename and directory location where the firmware upgrade file resides. 5. If the upload is successful, the ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 51

    Apx-1 A . Interface Description A.1. Serial COM / RS232 Port Interface Figur e A.1: COM Port Interface ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 52

    Apx-2 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide B. Specifications Power Input / Output: • AC Input: T wo Separate Circuits; 16 Amps Max. per Circuit ▪ V oltage: 100 - 240 V AC 50/60 Hz ▪ Connectors: T wo (2) IEC320-C20 Inlets • AC Outputs: ▪ Connectors: IEC320-C13 Outlets. (IPS-800CE-D16 has Eight Outlets, IPS-1600CE-D16 has 1 ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 53

    Apx-3 Appendices C. Customer Service Customer Service hours are from 8:00 AM to 5:00 PM, PST/PDT , Monday through Friday . When calling, please be prepared to give the name and model of the unit, its serial number and a description of its symptoms. If the unit should need to be returned for factory repair it must be accompanied by a Return Authoriz ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 54

    Apx-4 IPS-800CE-D16 & IPS-1600CE-D16 - User ’ s Guide T rademark and Copyright Information WTI and W estern T elematic are trademarks of W estern T elematic Incorporated. All other product names mentioned in this publication are trademarks of their respective companies. Information and descriptions contained herein are the property of W ester ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 55

    Index -1 Inde x # 100Base-T 4-3 10Base-T 4-3 A Activity Indicator 2-2 Automated Mode 5-8, 6-7 to 6-8 B Baud Rate 5-10 Boot/Sequence Delay 5-12 to 5-13 Bus A 2-1 Bus B 2-1 C Cable Keepers 4-1 Circuit Breaker 2-1 Co-Location Features 5-12 Command Confirmation 5-8, 6-8 Command Echo 5-7 Command Mode Access 5-2 to 5-4 Logging Out 6-6 Command Prompt 5-8 ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 56

    IPS-800/1600-D20 Series - User ’ s Guide Index -2 O ON Indicator 2-2 Operation 6-1 to 6-8 W eb Browser Interface 6-1 to 6-2 P Parity 5-10 Passwords 5-4, 6-7 Plug 5-1, 5-12 System 5-1, 5-6 User 5-1, 5-12 Password Prompt 5-3 Permit 5-16 Plug Indicators 2-1 Plug Name 5-12 Plug Password 5-12 Plug Status Screen 6-7 T ext Interface 6- 3 W eb Browser In ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 57

    ...

  • Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - page 58

    5 Sterling • Irvine • California 92618 (949) 586-9950 • Toll Free: 1-800-854-7226 Fax: (949) 583-9514 • http://www.wti.com ...

Fabricante Western Telematic Categoría Switch

Los documentos del dispositivo Western Telematic IPS-800CE-D16, IPS-1600CE-D16 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Western Telematic
- manuales de instrucciones IPS-800CE-D16, IPS-1600CE-D16
- hojas de producto Western Telematic
- folletos informativos
- o etiquetas energéticas Western Telematic IPS-800CE-D16, IPS-1600CE-D16
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Western Telematic IPS-800CE-D16, IPS-1600CE-D16.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Western Telematic IPS-800CE-D16, IPS-1600CE-D16, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Western Telematic IPS-800CE-D16, IPS-1600CE-D16. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Western Telematic IPS-800CE-D16, IPS-1600CE-D16.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Western Telematic IPS-800CE-D16, IPS-1600CE-D16, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Western Telematic IPS-800CE-D16, IPS-1600CE-D16. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Western Telematic IPS-800CE-D16, IPS-1600CE-D16.

El manual de instrucciones completo de Western Telematic debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Western Telematic IPS-800CE-D16, IPS-1600CE-D16, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Western Telematic IPS-800CE-D16, IPS-1600CE-D16 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Western Telematic IPS-800CE-D16, IPS-1600CE-D16 - que deben facilitarnos los primeros pasos durante el uso de Western Telematic IPS-800CE-D16, IPS-1600CE-D16
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Western Telematic IPS-800CE-D16, IPS-1600CE-D16
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Western Telematic IPS-800CE-D16, IPS-1600CE-D16 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Western Telematic IPS-800CE-D16, IPS-1600CE-D16?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Western Telematic IPS-800CE-D16, IPS-1600CE-D16, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Western Telematic IPS-800CE-D16, IPS-1600CE-D16 probablemente compartirá una forma de solucionarlo.