    1 Pr oduct Data 313AA V/JA V Plus 80x 4- -W A Y M U L T I PO I S E INDUCED - - COMBUSTION GAS FURNACE INPUT CAP ACITI ES: 45,000 THRU 135,000 Btuh A08288 THE B R Y ANT Plu s 80x GAS FURNACE The Plus 80x Del uxe 4 - -W ay Mul ti poise G as Furna ce of fe rs ou tstand in g features in an 80 % AFU E furn ace. De luxe fe atur es inc lude : an ECM motor ...

  • Bryant 313AAV/JAV - page 2

    2 FURNACE COMP ONENTS VENT ELBOW MAIN LIMIT SWITCH (BEHIND GAS V AL VE) DRAFT SAFEGUARD SWITCH FLAME SENSOR GAS MANIFOLD GAS B URNER BLO WER DOOR SAFETY SWITCH BLO WER AND MOTOR CONTR OL RA TING PLA TE NOT SHOWN (LOCA TED ON BLO WER DOOR) HOT SURF A CE IGNITER MANU AL RESET LIMIT SWITCHES GAS V AL VE FLUE COLLECTOR BOX PRESSURE SWITCH INDUCER MO TO ...

  • Bryant 313AAV/JAV - page 3

    3 BR Y ANT ACCESS ORIES MECHANICAL OR ELECTRONIC AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. A97432 CONTROLS: THERMOSTATS AND ZONING Available in programmable and non-programmable models, Bryant ...

  • Bryant 313AAV/JAV - page 4

    4 BR Y ANT ACCESS ORIES DESC RI PTION 313AAV/J AV PA R T N O . 024045 048070 048090 060110 060135 Cartridg e Me dia Filter FIL BBCAR 0016 X X FIL BBCAR 0020 X X FIL BBCAR 0024 X EXPX XUNV0016 X X EZ Flex Media Filter with End Caps EXPX XUNV0020 X X EXPX XUNV0024 X EXPXX FIL0016 X X Repla cemen t EZ Flex F ilt er Media EXPXX FIL0020 X X EXPXX FIL002 ...

  • Bryant 313AAV/JAV - page 5

    5 PHYS ICAL DA T A UNI T SIZ E 024045 048070 048090 060110 060135 OUTPUT CAP ACITY BTU H ( N o n --- w e a t h e r i z e d I C S ) 313JAV Upflow; all 313AAV 36,000 53,000 72,000 90,000 107,000 313JAV Downflow/Horizontal 34,000 51,000 69,000 86,000 102,000 INPUT BTUH 313JAV Upflow; all 313AAV 44,000 66,000 88,000 110,000 132,000 313JAV Downflow/Hori ...

  • Bryant 313AAV/JAV - page 6

    6 SEE NO TES: 1,2,4,7,8,9 SEE NO TES: 1,2,3,4,7,8,9 SEE NO TES: 1,2,4,5,7,8,9 SEE NO TES:1,2,3,4,5,7,8,9 SEE NO TES: 1,2,3,4,7,8,9 SEE NO TES: 1,2,4,5,6,7,8,9 A02063 A02060 A02058 A02059 A02061 A02062 UPFL OW UPFL OW DOWNFL OW DOWNFL OW DOWNFL OW DOWNFL OW Ve n t i n g N o t e s 1. F or co mmo n v ent, v ent co nn ector sizin g an d v ent m aterial ...

  • Bryant 313AAV/JAV - page 7

    7 SEE NO TES: 1,2,4,5,7,8,9 SEE NO TES: 1,2,4,5,7,8,9 SEE NO TES: 1,2,4,7,8,9 SEE NO TES: 1,2,4,7,8,9 SEE NO TES: 1,2,4,5,7,8,9 SEE NO TES: 1,2,4,5,7,8,9 SEE NO TES: 1,2,4,5,7,8,9 HORIZONT AL RIGHT HORIZONT AL RIGHT HORIZONT AL RIGHT HORIZONT AL LEFT HORIZONT AL LEFT HORIZONT AL LEFT HORIZONT AL LEFT A02069 A02068 A02070 A02064 A02066 A02065 A02067 ...

  • Bryant 313AAV/JAV - page 8

    8 AIR DELIVER Y - - CFM ( WITH FIL TER) * UNI T SIZ E RETURN - - - AIR SUPPL Y SPEED EXTE RNAL STATIC PRE SSUR E (in. wc) 0.1 0.2 0.3 0.4 0. 5 0.6 0.7 0. 8 0.9 1 024045 Botto m or Side(s) 5 1185 1145 1115 1075 1035 980 905 820 720 580 4 920 880 835 800 755 720 680 645 605 540 3 735 685 625 585 530 490 435 395 345 295 2 820 765 725 670 630 580 545 4 ...

  • Bryant 313AAV/JAV - page 9

    9 DIMENSIONS 2-7/16" 1-1/8" 28-7/8" (733mm) 25-1/4" 22-9/16" JUNCTION BOX LOCA TION 7/8" DI A ACCESSORY 1/2" (13 mm) DIA. THERMOST AT WIRE ENTR Y 3-15/16" (84mm) LEFT HAND GAS ENTRY 33-5/16" 24-7/8" 5-1/2" 7/8" (22mm) DIA. ACCESSORY 1 1/16" 21-5/8" BOTTOM INLE T 1-1 1/16" 13 ...

  • Bryant 313AAV/JAV - page 10

    10 A08471 MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. REGISTERED QUALITY SYSTEM C a r r i e r C o r p o r a t i o n R E G I S T E R E D F I R M I S O 9 0 0 1 # A 2 8 8 3 ¨ EFFICIENCY RA TING CERTIFIED CERTIFIED D ...

  • Bryant 313AAV/JAV - page 11

    11 TYPICAL WIRING SCHEMA TIC 115-V FIELD- SUPPLIED DISCONNECT A UXILIARY J-BO X 24-V TERMINAL BLOCK THREE-WIRE HEA TING-ONL Y FIVE WIRE NO TE 1 NO TE 2 FIELD-SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM WC R G Y GND GND FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING F A CT ORY 24-V WIRING F A CT ORY 115-V WIRING ...

  • Bryant 313AAV/JAV - page 12

    12 GUI DE SPE CI FICA TIO NS Ga s Furna ce 313AA V/JA V GENERAL Syste m Des cription Furni sh a _________________ fi xed c apa ci ty ga s- - fi red f urna ce for use wi th na tura l gas or pr opane ( fa ctor y author iz ed c onver si on kit r equir ed for pr opane ); furni sh cold air r etur n ple num; fur nis h extern al med ial cabin et for use w ...

Fabricante Bryant Categoría Furnace

Los documentos del dispositivo Bryant 313AAV/JAV que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bryant
- manuales de instrucciones 313AAV/JAV
- hojas de producto Bryant
- folletos informativos
- o etiquetas energéticas Bryant 313AAV/JAV
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bryant 313AAV/JAV.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bryant 313AAV/JAV, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bryant 313AAV/JAV. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bryant 313AAV/JAV.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bryant 313AAV/JAV, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bryant 313AAV/JAV. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bryant 313AAV/JAV.

El manual de instrucciones completo de Bryant debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bryant 313AAV/JAV - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bryant 313AAV/JAV, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bryant 313AAV/JAV que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bryant 313AAV/JAV - que deben facilitarnos los primeros pasos durante el uso de Bryant 313AAV/JAV
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bryant 313AAV/JAV
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bryant 313AAV/JAV en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bryant 313AAV/JAV?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bryant 313AAV/JAV, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bryant 313AAV/JAV probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)