    15 SEER USER’ s MANU AL & INST ALLA TION INSTR UCTIONS Single P acka g e Heat Pump - 2 Stage, R-410A Please read this inf or mation thoroughly and become familiar with the capabilities and use of y our appliance bef ore attempting to operate or maintain this unit. K eep this literature where y ou hav e easy access to it in the future. If a pr ...

  • Acnodes Q5RF SERIES - page 2

    2 Safety Inf ormation ........................................ 4 General Information ..................................... 4 Bef ore Y ou Install this Unit .......................... 4 Locating the Heat pump ............................ 4 Air Duct System ......................................... 5 Unconditioned Spaces ............................. ...

  • Acnodes Q5RF SERIES - page 3

    3 Figure 1. Digital Thermostat Fa n Mode T emperature Selector System Mode ABOUT THE HEA T PUMP Y our heat pump is a unique, all w eather comf or t- control appliance that will heat and cool your home year round and pro vide energy saving comf or t. It’ s an unknown f act that heat is alwa ys in the air , e v en when the outside temperature is be ...

  • Acnodes Q5RF SERIES - page 4

    4 GENERAL INFORMA TION Single packaged heat pumps are ready f or easy and immediate installation and can be readily connected into the high static duct system of a home. This unit is completely assembled, wired, and run tested at the factory . This heat pump is designed for outdoor installation onl y . The only connections needed f or installation ...

  • Acnodes Q5RF SERIES - page 5

    5 HEA T PUMP INST ALLA TION Unpacking the Unit It is recommended that the unit be unpack ed at the installation site to minimize damage due to handling. CA UTION: Do not tip the unit on its side. Oil may enter the compressor c ylinders and cause starting trouble. If unit has been set on its side, restore to upright position and do not run for se ve ...

  • Acnodes Q5RF SERIES - page 6

    6 2. Overlap the collar ends k eeping the small screw holes underneath. 3. Align the holes in the crimped area and install one screw . NOTE: It may be necessary to loosen the f our screws that hold the transition duct in order to install the supply fi tting. Re- tighten when installation is complete. 4. T ap collar (if necessar y) to ensure engage ...

  • Acnodes Q5RF SERIES - page 7

    7 Figure 7. Supply Damper A UTOMA TIC DAMPER IS CLOSED WHEN HEA T PUMP IS OFF Figure 6. Return Air Box NO TE: The return air box with g r ille and fi lter (Figure 6) should not be located in heavy tr affi c areas like hallw ays or center of rooms . A good spot is in a cor ner or under a tab le, if a minim um two inch clearance is a vailab le. 1. ...

  • Acnodes Q5RF SERIES - page 8

    8 Figure 8. P ower Entry Low V oltage High V oltage ELECTRICAL CONNECTIONS W ARNING: To av oid electric shock, personal injury , or death, turn off the electric power at the disconnect or the main service panel before making an y electrical connections. • Electrical connections must be in compliance with all applicable local codes and ordinances, ...

  • Acnodes Q5RF SERIES - page 9

    9 Blower Speed F or optimum system performance and comfort, it ma y be necessar y to change the factory speed setting. See T able 4 (page 20) f or factory settings. NO TE : Q5RF models hav e High Effi ciency Motors with 5 speed taps. W ARNING: To av oid electric shock, personal injury , or death, turn off the electric power at the disconnect or th ...

  • Acnodes Q5RF SERIES - page 10

    10 Thermostat Connections • The Q5RF heat pump is a two stage cooling and heating appliance that requires a 2-stage Cooling/Heating ther mostat. The heat-cool ther mostat pre vents simultaneous oper ation of the heating and cooling units and is equipped with an ON-A UT O fan mode that allo ws the home owner to oper ate the indoor blo wer when onl ...

  • Acnodes Q5RF SERIES - page 11

    11 Figure 10. T ypical Heat Pump Thermostat Connections T ypical Wiring (Field Supplied) for 2-Stage Cool, 2-Stage Electric Heat T ypical Wiring (Field Supplied) for 2-Stage Cool, 1 Stage Electric Heat E O G R Y1 INDOOR THERMOST A T SUB-B ASE Y2 W1 C 1 2 3 4 5 6 7 8 9 Bro wn Orange Accessory Heat Plug AMBIENT SENSOR COIL SENSOR TEST LR C Y O W2 IN ...

  • Acnodes Q5RF SERIES - page 12

    12 ST ARTUP & ADJUSTMENTS Pre-Start Checklist The f ollowing check list should be observed prior to star ting the unit.  Is the unit lev el? Unit should be lev el or slightly slanted tow ard the drain for proper condensate drainage .  Is the unit installed with the proper clearances as listed in Figure 3 (page 6)?  Is the wir ing corre ...

  • Acnodes Q5RF SERIES - page 13

    13 Cooling Mode When the TEST pins are shor ted together for more than 1 second, the Anti Shor t Cycle Timer will be bypassed. Adjustment of Refrigerant Charge CA UTION: This heat pump contains liquid and gaseous refrigerant under pressure . Adjustment of refrig erant char g e should only be attempted b y qualifi ed, trained personnel thor oughly ...

  • Acnodes Q5RF SERIES - page 14

    14 Refrigerant Charging Charts for Cooling Mode of Operation Figure 11. Charging Chart for 2 ton Units 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 LIQ UID PR E SSU RE ( PSIG) LI Q UI D T EMP ERATURE (F) R em ove r ef ri gerant w hen above c urve Add r e f r i g e r a n t ...

  • Acnodes Q5RF SERIES - page 15

    15 Refrigerant Charging Charts for Cooling Mode of Operation - Continued Figure 14. Charging Chart for 5 ton Units 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 LIQ UID PR ES SU RE ( PSIG) LI Q UI D T EMP ERATURE (F) Q5RF-X60K C OO L I NG CH ARGI N G CH A RT R em ove r ef r ...

  • Acnodes Q5RF SERIES - page 16

    16 Q5RF-X24K OUTDOOR TEMPERA TURE (DEG. F) 0 1 02 03 04 05 06 0 Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Press Press. T emp . Press. Press. T emp. Press. Press. T emp. Press. Press. T emp. Press. Press. T emp. Press. Press. T emp. Press. Press. T emp. 37 205 ...

  • Acnodes Q5RF SERIES - page 17

    17 T able 3. Refrig erant Charging T ables f or Heating Mode of Operation - 4 & 5 T on Units Q5RF-X48K OUTDOOR TEMPERA TURE (DEG. F) 0 1 02 03 04 05 06 0 Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Press Press. T emp . Press. Press. T emp. Press. Press. T e ...

  • Acnodes Q5RF SERIES - page 18

    18 3. Not sutiable on systems that exceed 150V to gr ound. 4. For replacement wires use conductors suitable f or 105°C. 208/230V Q5RF/PPH2RF SERIES SMALL P A CKA GE H/P W/DEMAND DEFROST 2 T ON AND 3 T ON 60HZ/SINGLE PHASE 1. Disconnect all power bef ore servicing. 2. For supply connections use copper conductors onl y . 3. Not sutiable on systems t ...

  • Acnodes Q5RF SERIES - page 19

    19 NO TES: FIELD WIRING LEGEND: LOW V OL T AGE HIGH V OL T AGE 208/230V Q5RF/PPH2RF SERIES SMALL P A CKA GE H/P W/DEMAND DEFROST 4 T ON AND 5 T ON 60HZ/SINGLE PHASE 1. Disconnect all power bef ore servicing. 2. For supply connections use copper conductors onl y . 3. Not sutiable on systems that exceed 150V to gr ound. 4. For replacement wires use c ...

  • Acnodes Q5RF SERIES - page 20

    INST ALLER: PLEASE LEA VE THESE INST ALLA TION INSTRUCTIONS WITH THE HOMEO WNER. 7091580 Specifi cations and illustrations subject to change without notice or incurring obligations. Printed in U.S .A. (02/10) O’F allon, MO 7091580 ¢709158D¤ COMPONENT FUNCTIONS Low Pressure Switc h The low pressure s witch is factory installed and located in th ...

Fabricante Acnodes Categoría Heat Pump

Los documentos del dispositivo Acnodes Q5RF SERIES que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Acnodes
- manuales de instrucciones Q5RF SERIES
- hojas de producto Acnodes
- folletos informativos
- o etiquetas energéticas Acnodes Q5RF SERIES
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Acnodes Q5RF SERIES.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Acnodes Q5RF SERIES, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Acnodes Q5RF SERIES. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Acnodes Q5RF SERIES.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Acnodes Q5RF SERIES, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Acnodes Q5RF SERIES. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Acnodes Q5RF SERIES.

El manual de instrucciones completo de Acnodes debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Acnodes Q5RF SERIES - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Acnodes Q5RF SERIES, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Acnodes Q5RF SERIES que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Acnodes Q5RF SERIES - que deben facilitarnos los primeros pasos durante el uso de Acnodes Q5RF SERIES
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Acnodes Q5RF SERIES
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Acnodes Q5RF SERIES en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Acnodes Q5RF SERIES?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Acnodes Q5RF SERIES, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Acnodes Q5RF SERIES probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)