    BLOOMFIELD INDUST RIES 2 ERIK CIRCLE , P . O. Box 280 V erdi , NV 8943 9 Cust omer Servi ce ( 775) 345 -0444 Ext .502 fax: (775) 345-0569 www .well sbl oomfi eld. com p/n 74340 Rev.C M673 040402 cps 673 OWNERS MANUAL for SS2 - SERIES DUAL SATELLITE COFFEE BREWERS wit h ELECTRONIC PROGRAMMABLE CONTROL and EXTERNALLY HEATED SATELLITE SERVERS MODEL : ...

  • Bloomfield 9421 (SS2-HE) - page 2

    NOTE: For your protection, please note that equipmen t in this shipment was carefully inspected and packaged by skilled personnel befor e leaving the factory. Upon accep- tance of this shipment, the transp ortation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1. VISIBLE LOSS OR DA M AGE: Be certain that an ...

  • Bloomfield 9421 (SS2-HE) - page 3

    TABLE OF CONTENTS Thank You for purcha sing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life. This ma nual contains the information needed to properly install this appliance, and ...

  • Bloomfield 9421 (SS2-HE) - page 4

    FE AT UR ES AN D OP ER AT IN G CO N TR O LS 2 Fig 1. SS-2 Satellite Brewing System Features & Operating Controls ...

  • Bloomfield 9421 (SS2-HE) - page 5

    FEATURES AND OPER A TING CONTRO LS (continued) Brewer Adjustable Legs Brewing Controls Digital Readout Bypass Nozzle Hot W ater Faucet Name plate Power Key System S w itch (not shown) Satellite Locator/Warmer Warmer Switches Brew Chamber Brew Chamber Wire Rack Satellite Brew-Thru Lid Handles Name plate Serving Faucet Sight Glass Drip Tray (optional ...

  • Bloomfield 9421 (SS2-HE) - page 6

    This appliance is inten ded for use in co mmercial e stablishments only. This appliance is inten ded to brew hot beverage, specif ically coffee, for human consumption. No other use is recommended or autho rized by the manufacturer or its agents. Operators of this appliance must be familiar with the appliance use, limitation s and associat ed restri ...

  • Bloomfield 9421 (SS2-HE) - page 7

    5 INSTALLATION INSTRUCTIONS INSTALL LEGS The brewer is provided with 4" adjustable legs and rubber feet. Be sure the legs are securel y screwed into th e base o f the br ew er, and that the rubber feet are properly installed. LEVEL THE UNIT The adjustable legs allow the brewer to be le veled. Set the brew er in its ultimate operating location ...

  • Bloomfield 9421 (SS2-HE) - page 8

    INSTALLATION INSTRUCTIONS (continued) 6 IMPORTANT: Initial set-up must be performed by a qualified installer or qualified service technician. Improper set-up will damage the brewer an d void the warranty. DO NOT CONNECT POWER TO BREWER WITH SATELLITES IN PLACE. NOTE: If “NO WATER SENSED” error message is displayed: * Disconn ect brewer fr om el ...

  • Bloomfield 9421 (SS2-HE) - page 9

    7 NOTE: If water is not sensed at the water level sensor within 20 min ute s: Heater will be disabled Error message NO WATER SENSED will be displayed Call the PHONE NUMBER displayed for servic e. GETTING S TARTED Check the brewer and satellites: Check that the brewer is clean and the drip tray (if used) is em pty . Check that the satellit es are em ...

  • Bloomfield 9421 (SS2-HE) - page 10

    OPERATING INSTRUCTIONS (continued) Fig. 4 Operating Controls Fig. 5 Brew Basket CA UTIO N: Burn Hazard Basket and contents are hot to the touch and may cause burns on contact. BREWING CO FFEE Prepare the Brew Baskets: Make s ure the w ire rack is properly insta lled in eac h brew chamber. Insert one (1) Bloomfield paper filter into each brew chambe ...

  • Bloomfield 9421 (SS2-HE) - page 11

    9 OPERATING INSTRUC TIONS (continued) WAT ER FLOW Fig. 6 Wa ter Flow Diagram INLET The INLET VALVE is controlled by a signal from the CONTRO L BOARD. If the W ATER LEVEL PROBE does not detect water, the inlet solenoid is opened until w ater is again sensed. BREW The BRE W VALVE fed by g ravity from the hot w at er tank, and is controlled by a signa ...

  • Bloomfield 9421 (SS2-HE) - page 12

    CLEANING INSTRUCTIONS 10 CLEANING I NSTRUCTIONS CAUTION: Burn Hazard Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. WARNING: Electric Shock Hazard DO NOT immerse or submerge satell ites. Fluid may saturate the insulation and short-circuit the receptacle connectors. Electric shock may cause in ...

  • Bloomfield 9421 (SS2-HE) - page 13

    11 CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite PRECAUTIONS: Drain Satellite bef ore Cleaning FREQUENCY: T w ice W eekly TOOLS: Sight Glass Brush, Saniti zer Sof t Clean Cloth, Bucket 1. Remove and drain sa tellites. Rem ove lids. 2. Place 1 packet of Sanitizer into 2-1/2 gallons of warm tap water. Pour approximately 1 gallon of san ...

  • Bloomfield 9421 (SS2-HE) - page 14

    PROGRAMMING INSTRUCTIONS Fig. 7 Function Keys NEW MENU SETTINGS Menu Program: Press POWER key to enter OFF m ode. Press and hold 3rd & 6th keys for 3 seconds Advance thru m enus by pressing the 1st key Advance thru items by pressing the 3rd key To exit, press 2nd key Clock Settings: Press POW ER key to enter ON mode Press 3r d & 4th k ey s ...

  • Bloomfield 9421 (SS2-HE) - page 15

    PROGRAMMING INSTRUCTIONS (continued) 13 PRECISE BREWING TEMPERATURE™: The brew cycle will not start until the water in the tank is at the proper t emperat ure. If START BREW key is pressed and held for 3 seconds du ring “ Brew Wait ” th e brew w ill proceed immediately . Note: the f ollowing saf ety features pre vent multiple unattended brews ...

  • Bloomfield 9421 (SS2-HE) - page 16

    ON/OFF – Normal Operation (Non A utomatic Ti mer): To turn the brewer OFF, press the POWER key: 2 beeps w ill be heard and the brewer will be turned OFF, indicated by all lights being off. To turn the brewer ON, press the POWER key: 2 beeps will sound, all lights will flash once, then the PO W ER LED will glow. NOTE : The HEAT LED will glow if th ...

  • Bloomfield 9421 (SS2-HE) - page 17

    PROGRAMMING (continu ed) 15 Brew Volume The 1st key is the Standard Brew Volume. When a brew volume other than standar d brew volum e is selected, the Brewer will complete that brew then return to the standard brew volum e automatically. 7. Automatic Start-Up in Previous Mode : If the Satellite Brew er au tom atic timer is OFF (the factory setting) ...

  • Bloomfield 9421 (SS2-HE) - page 18

    PROGRAMMING (continued) The factory programming has the After Hours™ mode turne d OFF. W h ile in the After Hours mode, the POWER LED will flash continuously. Keypadlock™ deters unauthorized operation of the brew er. This feature is OFF in the standard factory settings. 12. After Hours™: The After Hours™ can be programmed to com e on fro m ...

  • Bloomfield 9421 (SS2-HE) - page 19

    17 TROUBLESHOOTING SUGGESTIONS DESCRIPTION OF PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY No lights or heat Unit not plugg ed in or circuit breaker tripped Reset circ uit break er Plug brewer into elec tric po w er Power switch OFF Turn pow er switch ON No heat Hi-limit safety tripped Allow brewer to cool, verify water level, reset hi-limit Brewer over ...

  • Bloomfield 9421 (SS2-HE) - page 20

    SERVICING IN STRUCTIONS 18 CA UTIO N - CH EMICA L BURN HA Z A RD Deliming chem icals are caustic. W ear appropriate pr otective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rmed by qualified and ex- perienced service personnel. IMPORT ANT: DO NOT spill, splash ...

  • Bloomfield 9421 (SS2-HE) - page 21

    SERVICING INSTRUCTIONS (continued) 19 10. Reinstall tank lid asse mbly into hot w ater tank. Ma ke sure the lid gasket is properly in place, then reinstall the hold- down clamps. 11. Rem ove spray disks and gaskets. Rinse both brew heads with clean water. Using a sti ff brush, scrub spray disk to remove any lime or calcium build-up. Reinstall gaske ...

  • Bloomfield 9421 (SS2-HE) - page 22

    EXPLODED VIEW C ABINET AND EXTERIOR COMPONENTS 20 ...

  • Bloomfield 9421 (SS2-HE) - page 23

    21 ...

  • Bloomfield 9421 (SS2-HE) - page 24

    EXPLODED VIEW I NTERIOR COMPONENTS 22 26 32 38 39 36 33 3 41 1 14 30 29 21 19 16 17 47 18 5 8 6 7 37 42 43 45 31 3 9 15 40 48 49 30 34 46 10 34 50 13 4 27 3 28 24 22 44 12 25 27 20 35 11 2 23 29 ...

  • Bloomfield 9421 (SS2-HE) - page 25

    23 ITEM SERVICE # DESCRIPTION QTY 1 84427 VALVE ASSEMBLY 1 2 83778 RETAINING CLIP TANK LID 4 3 NUT KEP 8-32 SS 22 4 8043-12 GASKET COVER TANK 1 5 8812-57 FITTING UNION 1/4 x 1/4 1 6 8710-10 NUT HEX BR 7/16-20 x 1/8 1 7 84370 TUBE ASSY INLET 1 8 8551-53 WASHER SS 1 9 8783-1 FAUCET HOT W ATER 1 10 BRACKET OUTLET VALVE 2 11 83521 PROBE ASSY W ATER LEV ...

  • Bloomfield 9421 (SS2-HE) - page 26

    24 WIRING DIAGRAM ...

  • Bloomfield 9421 (SS2-HE) - page 27

    25 SATELLITE EXPLODED VIEW & PARTS LIST SATE LLI TE MO DEL 9 440 ITEM P ART NO. DESCRIP TION QTY 1 WELDMENT , SA T ELLITE 1 2 83863 T A NK LID ASSY 1 3 84313 HANDLE / F A UCET GUARD 1 4 84341 F AUCET & SHANK ASSY 1 4.1 84390 F AUCET , MODEL ES 1 4.2 8700-25 L SEA T CUP , #3S10 1 4.3 84392 HANDLE, #13SBE-SNAP 1 4.4 84394 C-RIN G #18-1 1 4.5 ...

  • Bloomfield 9421 (SS2-HE) - page 28

    Bloo mfie ld Indust ri es, Inc. Divisi on o f Carr ier Re friger ation Bloo mfie ld In dust ries Canad a Li mite d Divisi on o f Carr ier Re friger ation PO. B ox 280 V erdi, NV . 89439 T eleph one ( 775)3 45-044 4 Serv ice: (888) 492-27 82 website: www .wellsbl oomfi eld.com 585 0 Keaton Cr esent Missi ssaug a, Ont ari o, Canad a L5R 3K2 T eleph o ...

Fabricante Bloomfield Categoría Coffeemaker

Los documentos del dispositivo Bloomfield 9421 (SS2-HE) que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bloomfield
- manuales de instrucciones 9421 (SS2-HE)
- hojas de producto Bloomfield
- folletos informativos
- o etiquetas energéticas Bloomfield 9421 (SS2-HE)
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bloomfield 9421 (SS2-HE).

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bloomfield 9421 (SS2-HE), instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bloomfield 9421 (SS2-HE). Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bloomfield 9421 (SS2-HE).

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bloomfield 9421 (SS2-HE), ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bloomfield 9421 (SS2-HE). Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bloomfield 9421 (SS2-HE).

El manual de instrucciones completo de Bloomfield debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bloomfield 9421 (SS2-HE) - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bloomfield 9421 (SS2-HE), preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bloomfield 9421 (SS2-HE) que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bloomfield 9421 (SS2-HE) - que deben facilitarnos los primeros pasos durante el uso de Bloomfield 9421 (SS2-HE)
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bloomfield 9421 (SS2-HE)
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bloomfield 9421 (SS2-HE) en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bloomfield 9421 (SS2-HE)?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bloomfield 9421 (SS2-HE), haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bloomfield 9421 (SS2-HE) probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)