Manual de instrucciones FMI GL36STE

20 de páginas 1.38 mb
Descargar

Pasar a la página of 20

Summary
  • FMI GL36STE - page 1

    For more information, visit www .fmiproducts.com NA TURAL GAS MODELS (V)GL36ST AND (V)GL36STE PROP ANE/LP GAS MODELS (V)GL36STP AND (V)GL36STEP 2-SIDED (SEE-THROUGH), VENTED DECORA TIVE GAS APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANU AL FOR YOUR SAFETY — Do not store or use gasoline or any other ammable ...

  • FMI GL36STE - page 2

    www .fmiproducts.com 55173H 2 W ARNING: Improper installation, adjustment, altera - tion,service ormaintenancecan causeinjury orprop - erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a ...

  • FMI GL36STE - page 3

    www .fmiproducts.com 55173H 3 SAFETy INFORMA TION W ARNING: This product c o n t a i n s a n d / o r g e n e r a t e s chemicals known to the State of California to cause cancer or birth defects or other reproduc - tiveharm. IMPORTANT: Read this owner’s man ual care ful ly and compl ete ly bef ...

  • FMI GL36STE - page 4

    www .fmiproducts.com 55173H 4 11. Keep the area around your replace clear of combustible materials, gasoline and other ammable vapor and liquids. Do not run re- place where these are used or stored. Do not place items such as clothing or decorations on or around replace. 12. Do not use this replace to cook food or burn paper or other ...

  • FMI GL36STE - page 5

    www .fmiproducts.com 55173H 5 Figure 2 - T ypical T wo-Sided Fireplace Installation INTRODUCTION Models (V)GL36ST/P and (V)GL36STE/EP are decorative gas appliances that use a millivolt gas control and piezo pilot or an electronic gas control valve with an electronic ignition system respectively . These systems require a 6", B-type venting syst ...

  • FMI GL36STE - page 6

    www .fmiproducts.com 55173H 6 Figure 3 - Clearances from T op V iew Figure 4 - Clearances from Side V iew MANTEL CLEARANCES W oodwork, such as wood trims, mantel s and other comb ustib le materia ls, should not be placed within 7" of the opening of this appliance (see Figure 5). Combustible material above the fireplace projecting more than 1 1 ...

  • FMI GL36STE - page 7

    www .fmiproducts.com 55173H 7 FIREPLACE INST ALLA TION Continued FRAMING Construct framing using dimensions shown if Figures 6, 7 and 8. (Use the gure applicable to your application.) Figure 6 shows the framing dimensions prior to having the appliance in place. Once the unit has been tted, bring studs in agains t nailing anges located on t ...

  • FMI GL36STE - page 8

    www .fmiproducts.com 55173H 8 FIREPLACE INST ALLA TION Continued OPTIONAL OUTSIDE AIR KIT (MODEL AK-4) The installation of an outside air kit should be completed during the rough framing of the re- place due to the nature of it's location. Outside combustion air is accessed through a vented crawl space. CAUTION: Air inlet ducts must not? ...

  • FMI GL36STE - page 9

    www .fmiproducts.com 55173H 9 FIREPLACE INST ALLA TION Continued GAS SUPPL Y TESTING Note: This section is intended as a guide for quali - ed technicians installing gas to this appliance. CAUTION: Do not connect appliancebefore pressuretest - ing gas piping. Damage to gas valvemayresultandanunsafe con ...

  • FMI GL36STE - page 10

    www .fmiproducts.com 55173H 10 T o install: 1. Remove gas line cover plate from appliance’ s outer surround at the location to be used. 2. Remove insulation from inside the gas line conduit sleeve. 3. Run gas line through sleeve. 4. Prepare incoming black iron gas line with T eon tape or pipe joint compound. (Check local codes as to the use of ...

  • FMI GL36STE - page 11

    www .fmiproducts.com 55173H 11 FIREPLACE INST ALLA TION Continued MANTELS Mantels, combustible or non-combustible, may be constructed as long as proper clearances are observed (see Figure 2, page 6 and Clearances , page 6). PILOT ASSEMBL Y ADjUSTMENT The pilot assembly is factory preset for the proper ame height. Alteration to factory settings m ...

  • FMI GL36STE - page 12

    www .fmiproducts.com 55173H 12 OPTIONAL GLASS DOOR Glass doors are optional with this gas appliance (see Replacement Parts and Accessories , page 19). Installing Glass Door 1. Be sure top spring clip hole is aligned with hole in replace frame (see Figure 21). Fit glass door top pin into aligned holes. 2. Swing inner end of bottom clip out away f ...

  • FMI GL36STE - page 13

    www .fmiproducts.com 55173H 13 OPERA TING FIREPLACE MILLIV OL T MODELS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a re or explosion may result causing property damage, per - sonalinjuryorlossoflife. A. This appliance has a pilot which mu ...

  • FMI GL36STE - page 14

    www .fmiproducts.com 55173H 14 TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be performed. 3. Remove control access panel. 4. Pus h in gas con tr ol knob and tur n clock wis e to “OFF”. Do not force. 5. Replace control access panel. OPERA TING FIREPLACE Continued Fig ...

  • FMI GL36STE - page 15

    www .fmiproducts.com 55173H 15 CLEANING AND MAINTENANCE W ARNING: Installation and repair should be done by a qualied service person. The applianceshouldbeinspected before each use and at least annuallyby a qualiedservice person. More frequent clean- in g ma y be ...

  • FMI GL36STE - page 16

    www .fmiproducts.com 55173H 16 DO NOT CONNECT N.C.SW HE A T LIMIT SWITCH TH/TP TP TH WA LL SWITCH (SUPPLIED) TO 120V THERMOPILE PILOT IGNI TO R O F F P I L O T O N PILO T SAFET Y WIRE MAIN GAS INCOMING SUPPL Y MILLIVOL T WIRING DIAGRAM STEP DOWN TRANSFORMER EV2 SUPPL Y INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC N.C.SW HEA T LIMIT SWITCH 120V A ...

  • FMI GL36STE - page 17

    www .fmiproducts.com 55173H 17 TROUBLESHOO TING MILLIVOL T SYSTEM Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve lter OBSERVED PROBLEM Pilot will not lig ...

  • FMI GL36STE - page 18

    www .fmiproducts.com 55173H 18 TROUBLESHOO TING ELECTRONIC IGNITION SYSTEM Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve lter OBSERVED PROBLEM Pilot wil ...

  • FMI GL36STE - page 19

    www .fmiproducts.com 55173H 19 REPLACEMENT P ARTS AND ACCESSORIES Purchase these replace replacement parts and accessories from your local dealer . If they can not supply these parts, call FMI PRODUCTS, LLC at 1-866-328-4537 for referral information. Y ou can also write to the address listed on the back page of this manual. Before ordering, plea ...

  • FMI GL36STE - page 20

    55173 Rev . H 09/09 WARRANTy KEEP THIS WARRANTy FMI PRODUCTS, LL C LIMITED WARRANTIES NewProducts Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) year from the date of rst purchase from an authorized dealer provided the product has ...

Fabricante FMI Categoría Gas Heater

Los documentos del dispositivo FMI GL36STE que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos FMI
- manuales de instrucciones GL36STE
- hojas de producto FMI
- folletos informativos
- o etiquetas energéticas FMI GL36STE
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones FMI GL36STE.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje FMI GL36STE, instrucciones de servicio, instrucciones cortas o instrucciones de usuario FMI GL36STE. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto FMI GL36STE.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo FMI GL36STE, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar FMI GL36STE. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de FMI GL36STE.

El manual de instrucciones completo de FMI debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual FMI GL36STE - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice FMI GL36STE, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de FMI GL36STE que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo FMI GL36STE - que deben facilitarnos los primeros pasos durante el uso de FMI GL36STE
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con FMI GL36STE
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de FMI GL36STE en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de FMI GL36STE?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con FMI GL36STE, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con FMI GL36STE probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen