Manual de instrucciones Omega FMA 1500

40 de páginas 0.81 mb
Descargar

Pasar a la página of 40

Summary
  • Omega FMA 1500 - page 1

    www .omega.com e-mail: info@omega.com U ser ’ s Guide FMA 1400 and FMA 1500 Mass Flow Meters and Contr ollers Shop online at ...

  • Omega FMA 1500 - page 2

    Servicing Nor th America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford CT 06907-0047 T el: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 T el: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Service ...

  • Omega FMA 1500 - page 3

    T ABLE OF CONTENTS 1. UNP ACKING THE FMA 1400/1500 MASS FLOW METER................ 1.1 Inspect Package for External Damage......................................... 1.2 Unpack the Mass Flow Meter/Controller ....................................... 1.3 Returning Merchandise for Repair ............................................... 2. INST ALLA TION.. ...

  • Omega FMA 1500 - page 4

    7.3 Linearity Adjustment...................................................................... 7.3.1 Connections and Initial Warm Up........................................... 7.3.2 ZERO Adjustment................................................................. 7.3.3 25% Flow Adjustment............................................................. ...

  • Omega FMA 1500 - page 5

    TRADEMARKS Buna 7 is a registered trademark of DuPont Dow Elastometers. Kalrez 7 is a registered trademark of DuPont Dow Elastomers. Neoprene 7 is a registered trademark of DuPont. Omega ® -is a registered trademark of Omega Engineering, Inc. VCR 7 is a registered trademark of Crawford Fitting Co. V iton 7 is a registered trademark of Dupont Dow E ...

  • Omega FMA 1500 - page 6

    1 1. UNP ACKING THE FMA 1400/1500 MASS FLOW METER AND CONTROLLER 1.1 Inspect Package for External Damage Remov e the P acking List and v erify that you hav e received all equipment. If you hav e any questions about the shipment, please call the Omega 7 Customer Ser vice Depar tment at 1-800-622-2378 or (203) 359-1660. Y our FMA 1400/1500 Mass Flo w ...

  • Omega FMA 1500 - page 7

    2 It is also pref erable to install the FMA 1400/1500 transducer in a stab le environment, free of frequent and sudden temperature changes, high moisture , and drafts. Prior to connecting gas lines inspect all par ts of the piping system including fer- rules and fittings for dust or other contaminants . Be sure to obser v e the direction of gas flo ...

  • Omega FMA 1500 - page 8

    FIGURE 2-1, WIRING DIAGRAM FOR FMA 1400/1500 TRANSDUCERS FIGURE 2-3, FMA 1400/1500 15 PIN "D" CONNECTOR CONFIGURA TION 3 PIN FUNCTION 1 Chassis Ground 2 Common, Signal Ground For Pin 3 3 0-5 VDC Flow Signal 4 +15 VDC Power Supply 5 (-) 4-20 mA Flow Signal (optional) 6 +7 VDC for Local Set Point 7 (unassigned) 8 TTL Valve Off Control (FMA ...

  • Omega FMA 1500 - page 9

    Important notes: In general, "D" Connector numbering patterns are standardized. There are, how- e ver , some connectors with nonconforming patter ns and the numbering sequence on your mating connector ma y or ma y not coincide with the numbering sequence shown in our pin configuration tab le abov e. It is imperativ e that you match the ap ...

  • Omega FMA 1500 - page 10

    4. SPECIFICA TIONS FLOW MEDIUM: Please note that FMA 1400/1500 Mass Flow Meters and Controllers for ranges up to and above 10 L/min are designed to work with clean gases only . Never tr y to meter or control flow rates of liquids with any FMA 1500's or FMA 1400's. CALIBRA TIONS: Per formed at standard conditions [14.7 psia (1.01 bars) and ...

  • Omega FMA 1500 - page 11

    Omega 7 makes no expressed or implied guarantees of corrosion resistance of mass flow meters as pertains to different flow media reacting with components of meters. It is the customers' sole responsibility to select the model suitable for a particular gas based on the fluid contacting (wetted) materials offered in the different models. INLET A ...

  • Omega FMA 1500 - page 12

    A TTITUDE SENSITIVITY: 1% shift for a 90 degree rotation from horizontal to vertical; standard calibration is in horizontal position. OUTPUT SIGNALS: Linear 0-5 VDC (2000 Ω minimum load impedance); 4-20 mA optional (50-500 Ω loop resistance); 20 mV peak to peak max noise. COMMAND SIGNAL: 0-5 VDC (200K Ω input impedance). TRANSDUCER INPUT POWE ...

  • Omega FMA 1500 - page 13

    FLOW RANGES T ABLE I FMA 1500/1400 FOR RANGES UP TO 10 L/MIN LOW FLOW MASS FLOW METER/CONTROLLERS* T ABLE II FMA 1500/1400 FOR RANGES ABOVE 10 L/MIN MEDIUM FLOW MASS FLOW METER/CONTROLLERS* T ABLE III FMA 1500/1400 FOR RANGES ABOVE 10 L/MIN HIGH FLOW MASS FLOW METER/CONTROLLERS* *Flow rates are stated for Nitrogen at STP conditions [i.e. 70 F F (21 ...

  • Omega FMA 1500 - page 14

    T ABLE IV PRESSURE DROPS T ABLE V APPROXIMA TE WEIGHTS 5. OPERA TING INSTRUCTIONS 5.1 Preparation and W arm Up It is assumed that the Mass Flow Meter or Controller has been correctly installed and thoroughly leak tested as described in section 2. Make sure the flow source is OFF . Po wer up the transducer using y our own pow er supply (or tur n the ...

  • Omega FMA 1500 - page 15

    10 During initial powering of the FMA 1400/1500 transducer , the flow output signal will be indicating a higher than usual output. This is indication that the FMA 1400/1500 trans- ducer has not yet attained it's minim um operating temperature. This condition will automatically cancel within a f ew minutes and the transducer should e ventually ...

  • Omega FMA 1500 - page 16

    age is a linear representation of 0 to 100% of the full scale mass flow rate . Response time to set point changes are 1 second (FMA 1400 f or ranges up to 10 L/min) and 2 seconds (FMA 1400 f or ranges abov e 10 L/min) to within 2% of the final flow o ver 25 to 100% of full scale. On pin 6 of the FMA 1400 transducer is a regulated and constant +5VDC ...

  • Omega FMA 1500 - page 17

    utilizing +15VDC valv e configuration, connecting the TEST pin 12 on 15-pin "D" connectors) to ground will fully open the v alve . For FMA 1400's with a +30VDC valv e configuration, connecting the TEST pin to +15VDC will fully open the valv e. 6. MAINTENANCE 6.1 Introduction It is impor tant that the Mass Flow Meter/Controller is use ...

  • Omega FMA 1500 - page 18

    13 6.2.2 FMA 1400/1500 for ranges up to 10 L/min Unscrew the inlet compression fitting of meter . Note that the Restrictor Flow Element (RFE) is connected to the inlet fitting. Carefully disassemble the RFE from the inlet connection. The 50 micron filter screen will now become visib le. Push the screen out through the inlet fitting. Clean or replac ...

  • Omega FMA 1500 - page 19

    14 Contact Omega 7 f or optional sealing mater ials av ailable . Set the FMA 1400 into PURGE mode, and attempt to flush through with a clean, filtered, and neutral gas such as nitrogen. [Another option for fully opening the valv e is to remo v e the plastic cap on top of the v alv e , and turn the set screw coun- terclockwise until it stops . See s ...

  • Omega FMA 1500 - page 20

    FIGURE 7-1, CALIBRA TION POTENTIOMETER LOCA TIONS 7.2 Calibration of FMA 1500 Mass Flow Meters All adjustments in this section are made from the outside of the meter , there is no need to disassemble an y par t of the instr ument. FMA 1500 Mass Flow Meters ma y be field recalibrated/chec ked f or the same range the y were originally factory calibra ...

  • Omega FMA 1500 - page 21

    7.2.2 ZERO Adjustment Shut off the flow of gas into the Mass Flo w Meter . T o ensure that no seepage or leak occurs into the meter , it is good practice to temporarily disconnect the gas source. Using the multimeter and the insulated screwdriver , adjust the ZERO potentiometer [R29] through the access window f or 0 VDC (or 4 mA respectiv ely) at z ...

  • Omega FMA 1500 - page 22

    7.3.2 ZERO Adjustment Shut off the flow of gas into the Mass Flo w Meter . T o ensure that no seepage or leak occurs into the meter , it is good practice to temporarily disconnect the gas source. Using the multimeter and the insulated scre wdriver , adjust the ZERO potentiometer [R29] through the access window f or 0 VDC (or 4 mA respectiv ely) at ...

  • Omega FMA 1500 - page 23

     the transducer . The unit will now act as a mass flow meter . CA UTION: If the v alve is left in the A UTO (control) or OPEN mode f or an e xtended per iod of time, it ma y become war m or e ven hot to the touch. Use care in av oiding direct contact with the valv e during operation. F ollow steps outlined in section 7.2 and 7.3, then continue w ...

  • Omega FMA 1500 - page 24

    T ABLE VI FMA 1400 SOLENOID VAL VE ORIFICE SELECTION T ABLE 8. TROUBLESHOOTING 8.1 Common Conditions Y our Mass Flow Meter/Controller was thoroughly chec ked at n umerous quality control points during and after manufacturing and assemb ly operations. It was cal- ibrated in accordance to y our desired flow and pressure conditions f or a giv en gas o ...

  • Omega FMA 1500 - page 25

    8.2 T roubleshooting Guide 20 REMEDY check connection of power supply disconnect FMA 1400/1500 transducer from power supply; remove the short- ing condition or check polarities; fuse resets automatically disconnect power cord from AC supply; remove and inspect fuses at AC power input connector of FMA14PD Series; replace as necessary REMOVE CAUSE OF ...

  • Omega FMA 1500 - page 26

    21 REMEDY locate and correct return to factory for replacement return to factory for replacement locate and repair use matched calibration see K factor tables in APPENDIX 2 locate and correct return to factory for replacement flush clean or disassemble to remove impediments flush clean or disassemble to remove impediments or return to factory for r ...

  • Omega FMA 1500 - page 27

    F or best results it is recommended that instr uments are returned to the factory f or ser vicing. See section 1.3 f or retur n procedures. 8.3 T echnical Assistance Omega 7 Engineering will provide technical assistance ov er the phone to qualified repair personnel. Please call our Flow Depar tment (800) 872-9436 e xtension 2298. 22 Q O = Q a = Q r ...

  • Omega FMA 1500 - page 28

    APPENDIX 1 COMPONENTS DIAGRAMS 23 FMA 1500 METERING PC BOARD (ALSO INCORPORA TED IN FMA 1400) FMA 1400 CONTROL PC BOARD ...

  • Omega FMA 1500 - page 29

    24 APPENDIX 2 GAS F ACTOR T ABLE (“K” FACTORS) 1.162 1.293 1.787 .760 1.782 3.478 5.227 3.025 7.130 11.18 7.803 6.108 6.644 2.413 2.593 2.503 2.503 2.503 1.964 3.397 1.250 6.860 3.926 2.945 2.680 3.163 4.125 3.858 5.326 6.892 4.660 2.322 2.742 1.877 1.799 1.235 Acetylene C 2 H 2 Air Allene (Propadiene) C 3 H 4 Ammonia NH 3 Argon Ar Arsine AsH 3 ...

  • Omega FMA 1500 - page 30

    25 ACTUAL GAS K Factor Relative to N 2 Cp [Cal/g] Density [g/I] Dibromodifluoromethane CBr 2 F 2 Dichlorodifluoromethane (Freon-12) CCl 2 F 2 Dichlofluoromethane (Freon-21) CHCl 2 F Dichloromethylsilane (CH 3 ) 2 SiCl 2 Dichlorosilane SiH 2 Cl 2 Dichlorotetrafluoroethane (Freon-114) C 2 Cl 2 F 4 1,1-Difluoroethylene (Freon-1132A) C 2 H 2 F 2 Dimeth ...

  • Omega FMA 1500 - page 31

    26 Actual Gas K Factor Relative to N 2 Cp [Cal/g] Density [g/I] Hydrogen Fluoride HF Hydrogen Iodide HI Hydrogen Selenide H 2 Se Hydrogen Sulfide H 2 S Iodine Pentafluoride IF 5 Isobutane CH(CH 3 ) 3 Isobutylene C 4 H 6 Krypton Kr Methane CH 4 Methanol CH 3 Methyl Acetylene C 3 H 4 Methyl Bromide CH 2 Br Methyl Chloride CH 3 Cl Methyl Fluoride CH 3 ...

  • Omega FMA 1500 - page 32

    27 .30 .35 .40 .5982 .284 .3482 .69 .2635 .3883 .5096 .3237 .3287 .3278 .2031 .0608 .2691 .32 .2792 .2541 .1961 .4616 .48 1.44 Actual Gas K Factor Relative to N 2 Cp [Cal/g] Density [g/I] Phosphorous T richloride PCl 3 Propane C 3 H 8 Propylene C 3 H 6 Silane SiH 4 Silicon T etrachloride SiCl 4 Silicon T etrafluoride SiF 4 Sulfur Dioxide SO 2 Sulfu ...

  • Omega FMA 1500 - page 33

    APPENDIX 3 DIMENSIONAL DRA WINGS FMA 1500 FOR RANGES UP TO 10 L/MIN MASS FLOW METER NO TES: Omega 7 reser ves the right to change designs and dimensions at its sole discretion at any time without notice . F or cer tified dimensions please contact Omega 7 . 28 ...

  • Omega FMA 1500 - page 34

    FMA 1500 FOR RANGES ABOVE 10 L/MIN MASS FLOW CONTROLLER NO TES: Omega 7 reser ves the right to change designs and dimensions at its sole discretion at any time without notice . F or cer tified dimensions please contact Omega 7 . 29 ...

  • Omega FMA 1500 - page 35

    FMA 1400 RANGES UP TO 10 L/MIN MASS FLOW CONTROLLER NO TES: Omega 7 reser ves the right to change designs and dimensions at its sole discretion at any time without notice . F or cer tified dimensions please contact Omega 7 . 30 ...

  • Omega FMA 1500 - page 36

    FMA 1400 RANGES ABOVE 10 L/MIN MASS FLOW CONTROLLER NO TES: Omega 7 reser ves the right to change designs and dimensions at its sole discretion at any time without notice . F or cer tified dimensions please contact Omega 7 . 31 ...

  • Omega FMA 1500 - page 37

    NOTES: 32 ...

  • Omega FMA 1500 - page 38

    NOTES: 33 ...

  • Omega FMA 1500 - page 39

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of def ects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s W arranty adds an additional one (1) month grace period to the nor mal one (1) year pr oduct warranty to cover handling and shipping time . This ensures that OMEGA’ s cust ...

  • Omega FMA 1500 - page 40

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? O M EGA…Of Course! Shop online at www .omega.com TEMPERA TURE 5 Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies 5 W ire: Thermocouple, R TD & Thermistor 5 Calibrators & Ice Point References 5 Recorders, Contr ollers & Process Monit ...

Fabricante Omega Categoría Automobile Parts

Los documentos del dispositivo Omega FMA 1500 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Omega
- manuales de instrucciones FMA 1500
- hojas de producto Omega
- folletos informativos
- o etiquetas energéticas Omega FMA 1500
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Omega FMA 1500.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Omega FMA 1500, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Omega FMA 1500. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Omega FMA 1500.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Omega FMA 1500, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Omega FMA 1500. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Omega FMA 1500.

El manual de instrucciones completo de Omega debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Omega FMA 1500 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Omega FMA 1500, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Omega FMA 1500 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Omega FMA 1500 - que deben facilitarnos los primeros pasos durante el uso de Omega FMA 1500
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Omega FMA 1500
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Omega FMA 1500 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Omega FMA 1500?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Omega FMA 1500, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Omega FMA 1500 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)