Manual de instrucciones Viking Access Systems f1 gate

50 de páginas 3.04 mb
Descargar

Pasar a la página of 50

Summary
  • Viking Access Systems f1 gate - page 1

    I N S TA L L AT I O N INSTRUC TIONS AND SAFET Y INFOR MA TION FOR THE VIK ING F- 1 GA TE OPER A T OR CLASS I, II, III AND IV Commercial and Residential Vehicular Swing Gate Operator CLASS I, II, III AND IV Commercial and Residential ...

  • Viking Access Systems f1 gate - page 2

    The F-1™ gate operator has the capacity to operate swing gate up to 1500 lbs./12 ft. or 1000 lbs./16 ft. at 100% duty cycle under extreme conditions. This effi cient operator provides a solution for high traffi c commercial and residential applications. The F-1™ operator offers effi ciency and technology combined in a single package. THE V I ...

  • Viking Access Systems f1 gate - page 3

    F- 1 V ehicular Gate Operat or • Revision F 1NXMN10 .D • Oc tober 2 014 ...

  • Viking Access Systems f1 gate - page 4

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 2 P ARTS DIA GR AM : Item Description Part No. 1 Operat or Co v er Bolt (2) V AS WCB 2 Operat or Co v er VNXF1CV 3 Output Shaft Knob DWOUK10 4 Output Shaft Co v er VNXSWOSC 5 Clutch K ey V A WRCK20 6 Clut ch and Handle DWCL20 7 Output Arm DW AR20 8 Output Shaft DWOP20 9 C ontrol Boar d VFLEXPCB 10 Fuse - 15 ...

  • Viking Access Systems f1 gate - page 5

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 3 OPER A TOR REFERENC ES: 1 . C O VER BOL TS 2 . OUTPUT SHAFT C O VER (HA T) 3. MAIN C O VER AS SEMBL Y 4. MANUAL RELEASE HANDLE releases the clut ch to allo w f or manual oper ation 5. CLUT CH KEY install if application does not r equir e clutch t o slip; remo ve to manually oper at e the gat e 6. OUTPUT AR ...

  • Viking Access Systems f1 gate - page 6

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 4 C ONTROL BO ARD REFERENC ES: 1. POWER HARNES S C ONNECT OR pro vides po w er to the c ontr ol board. pg 18- 19 2. “OPEN LEFT” & “OPEN RIGHT” pro vides po w er to the mot or . pg 20 3. LIMIT SETUP BUTTONS av ailable for futur e de v elopments. 4. FEA TURE A CTIVA TION TRIM POT S activ ate and se ...

  • Viking Access Systems f1 gate - page 7

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 5 T ABLE OF C ONTENT S: P ARTS DIA GRAM/P ARTS LI ST 2 O P E R A T O R R E F E R E N C E S 3 CONTROL BOARD REF ERENC ES 4 I M P O R T A N T S A F E T Y I N F O R M A T I O N 6 -1 2 Important Safe ty Instruct ions 6 Important Install at ion Inst ructi ons 7 Maint enance 8 Ge nera l Safet y Preca utions ...

  • Viking Access Systems f1 gate - page 8

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 6 IMPORT A NT SAFET Y INFORMA TION ! W ARN I NG ! Not Foll owing thes e inst ruc tions m ay cause s ev ere inju ry o r death . IMPORT ANT SAFET Y INSTRUCTIONS ! W ARN I NG ! T o red uce the ris k of sev ere inj ur y or de ath. 1 . RE AD A ND FOL L O W ALL I NST RUC TI ONS . 2 . Never let child ren ope rate o ...

  • Viking Access Systems f1 gate - page 9

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 7 IMPORT A NT SAFET Y INFORMA TION ! W ARN I NG ! Not Foll owing thes e inst ruc tions m ay cause s ev ere inju ry o r death . IMPORT ANT INST ALLA TION INSTR UCTIONS ( Continued) 6 . Controls inten ded for u ser ac tivation must b e loc ated at leas t six feet ( 6’) awa y from any moving par t of the gate ...

  • Viking Access Systems f1 gate - page 10

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 8 IMPORT A NT SAFET Y INFORMA TION MAINTENANCE Remove the Pow er Ha rnes s from the Co ntrol Board . ( r efer to page 1 8) • Cle anan dlubri catetheturnin gpinsan dgatehinge susingthere comme nde d  lubr ican t. • Ch eckthatallh ardwareofthegate ...

  • Viking Access Systems f1 gate - page 11

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 9 ! C AU TI O N : T o Re duce the R isk of Fire o r Injur y to Pe rson s: IMPORT A NT SAFET Y INFORMA TION In stal l th e gate o perato r only w hen : The op erator is ap propriate for the con struc tion of the gate and th e Usag e Class of the gat e. UL 325 Gate Opera tor C lassifications GLOSSARY RE SI D E ...

  • Viking Access Systems f1 gate - page 12

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 10 IMPORT A NT SAFET Y INFORMA TION NOTE: T his t ype on in sta llation DOES NO T rev erse t he gate all t he way back to its li mits wh en the p hoto bea m is obs truc ted. T his in stall ation is o nly to protec t aga inst e ntrapm ent an d to comply with U L 325 . Sec ondar y Ent rapment Pro tection Phot ...

  • Viking Access Systems f1 gate - page 13

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 11 NOTE: T his t ype on in sta llation DOES NO T rev erse t he gate all t he way back to its li mits wh en the e dge se nsor i s obstr uc ted. Th is ins tall ation is on ly to protect aga inst e ntrapm ent an d to comply with U L 325 . Sec ondar y Ent rapment Pro tection Edge Sen sor ( co ntact sensor ) Inst ...

  • Viking Access Systems f1 gate - page 14

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 12 Audible Alarm R eset S w itch Installation Manual R eset f or the A udible Al arm • UL 32 5 stan dard requ ires an au dible a larm to soun d af ter two conse cutiv e ev ents detec ted b y the prim ar y entrapm ent protectio n of the gate operator ( o bstruc tion sensor ). • The a udible a larm w ...

  • Viking Access Systems f1 gate - page 15

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 13 ! C AU TI O N : T o Re duce the R isk of Fire o r Injur y to Pe rson s: ! W ARNING: For use with g ates at a maxim um 15 00 lbs . in weigh t or 16 f t . in l ength . IMPORT A NT INST ALL A T ION INF ORMA T ION 1000 lb. Locate Cont rol Buttons: 1 . Within sight of the gate, 2 . At a minimum h eight of 5 fe ...

  • Viking Access Systems f1 gate - page 16

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 14 Concrete Pad Optio n 1 . Follow the loc al buil ding cod e to det ermin e the requ ired depth of the co n cre te p a d . 2 . Pad me asure ment s recomme nd ed by Viking Access Syst ems a re at least 23 ” long , 20 ” wide an d 30” d eep to en sure the sta ble op eration of the ope rator , an d a mini ...

  • Viking Access Systems f1 gate - page 17

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 15 Pos t Mountin g Optio n TIP: The o perator ca n be po st mou nted t o be el ev ated above snow and fl ood lin es . 1 . Con sult the loc al bu ilding co des for th e depth an d concrete requirem ents . 2 . Maxim um 3 .0 0” O D pipe . 3 . Provide a suf ficie nt numb er of cond uit pathwa ys for all low po ...

  • Viking Access Systems f1 gate - page 18

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 16 Operat or Positioning ! I M P O R TA N T: Sw ing G ates must not o pen into pub lic access a reas . The gate mus t be ins talle d in a loc ation so that en ough cl eara nce is sup plied b etween th e ga te , while op enin g and clo sing , and a djacent s truc tures to reduce the risk of e ntrapme nt. G AT ...

  • Viking Access Systems f1 gate - page 19

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 17 G AT E O P E R AT O R I N S TA L L AT I O N STEP 1 Ins tall the Cl utch and cut the Arm A ssem bly to achiev e the desired dimensions for “ D” an d “E ” according to the formu las provided o n page 1 6 . STEP 2 With the gate at the close d, install t he Arm Assembly . Check that the dimension s co ...

  • Viking Access Systems f1 gate - page 20

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 18 High V oltage Suppl y Opti on ! Caution : Alwa ys turn off p ow er brea kers when work ing with high voltage . D O N OT conn ec t the “ Pow er Ha rnes s” to the Control Bo ard until the ele ctric al inst allation is comple t e and r eady f or v eri ficat ion . ELE CTRICA L IN ST A LL A TION Gro ...

  • Viking Access Systems f1 gate - page 21

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 19 Lo w V oltage Supp ly Op tion TIP: The o perator is eq uipp ed with a Modular Pow er Box that ca n be reloc ated to provide power for low v oltag e inst allations . Su pplies 24V A C to t he op erator . ! Caution : Alwa ys turn off p ow er brea kers when work ing with high voltage . D O N OT conn ec t the ...

  • Viking Access Systems f1 gate - page 22

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 20 LIMI TS SETUP Tip: Refe rring to Step 2b. The “C a m Hold er ” contai ns four ( 4) Guide Pi n hole s to allow for prop er pos itioning , if required , du e to an alternative operator orie ntation . STEP 2 At the “ Li mit C am & H olde r ” as sem bly: a. Loosen sc rew s on both of the “ Limit ...

  • Viking Access Systems f1 gate - page 23

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 21 LIMI TS SETUP ! TECHNICAL TIP: Each Li mit LED will illumin ate solid when th e correspo nding l imit swit ch is ac tuated. Th e LEDs will fl ash sim ultan eous ly while both limit switches a re actuated at the sa me time. Th is display may indic ate a problem with the limit switches o r wires. ! I ...

  • Viking Access Systems f1 gate - page 24

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 22 T w o Wir e C ommuni cation ! IMPORT ANT : DO NOT run the Ma ster /Slav e commu nication c abl e in the sa me cond uit or within 12 ” of 1 15 - 23 0v power supp ly cabl es . ! T echnical Tip: D O NOT set the “Ti mer ” an d/ o r “Overlap” fe atures on b oth operators Control B oards . Only tu rn ...

  • Viking Access Systems f1 gate - page 25

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 23 Wireless Com munic ation O ptions ! T echnical Tip: D O NOT set the “Ti mer ” an d/ o r “Overlap” fe atures on b oth operators Control B oards . Only tu rn these fe atures on at the M aster Co ntrol Board . MA STER /SL A V E S ETU P REQUIRED ADD-ON: Cho ose option A or B A . Vikin g K onn ec t - W ...

  • Viking Access Systems f1 gate - page 26

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 24 Initial Setting s C ON TROL BO ARD SETUP “Speed” Mot or Speed Inc reases o r decrea ses the sp ee d of gate tr ave l . “Ov er lap” Overlap Delay For Ma ster /Slav e appli cations . Th e control boa rd that has this featu re turned on is the M ASTE R and will de lay from 1- 6 secon ds . Slav ...

  • Viking Access Systems f1 gate - page 27

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 25 Initial Setting s NOT E: I nstall ing a shu nt or jump er on th e pins will ac tivate t he featu re. C ON TROL BO ARD SETUP “F ail Safe/Secure ” During c omple te po w er fail ure, incl uding b atter y po w er; det ermines t he f orc e require d to manua lly mov e the gat e. • Fail Saf e M ...

  • Viking Access Systems f1 gate - page 28

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 26 Obstruct ion Sensor ( Pr imar y Entrapment Prot ection ) ! IMPORT ANT : The app ropriate “ODS” set ting is de pen dant u pon the g ate installatio n and co nstruc tion . Set this fe ature accordingly. A dditiona l Safet y equ ipme nt shoul d be use d to reduce pos sible risk of in jur y or vehi ...

  • Viking Access Systems f1 gate - page 29

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 27 C ON TROL BO ARD SETUP HEATER CLS ON LOCK MOD ON Viking Heater The op erator ha s an integrated he at er that is th ermos tatically controlle d. Ac tivat e this feature whe n the op erator is used i n applic ation temp eratures down to - 2 0° F ( - 2 9 °C). T o set t he he ater to t urn o n at th ...

  • Viking Access Systems f1 gate - page 30

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 28 (THIS P AGE LEFT BL ANK INTENTIONALL Y) ...

  • Viking Access Systems f1 gate - page 31

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 29 A C CESSOR Y C ONNE CT IONS ! TECHNICAL TIP: For more inf ormat ion regar ding ac cessory connections to the control board an d individ ual inp ut terminal f unc tions , refer to “ App en dix ( A) ” , pages 42-43 . Not e regarding P hoto Be am types: Fail- Safe t ype - co nne ct the “ N .C .” term ...

  • Viking Access Systems f1 gate - page 32

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 30 A C CESSOR Y C ONNE CT IONS ! TECHNICAL TIP: For more inf ormat ion regar ding ac cessory connections and term inal f unc tions , refer to “ App en dix ( A) ” on pa ges 42-43 . Se e “ App endix (B)” on pag e 44 fo r connecting common radio rec eiv er models. For maximum recept ion range : L ...

  • Viking Access Systems f1 gate - page 33

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 31 Anti- T ailgate, Open Comman ds & Gu ard Station ! TECHNICAL TIP: For more inf ormat ion regar ding acces sory connections and t ermin al fu nctio ns, refe r to “ Appe ndix (A )” on pag es 42 -4 3. A C CESSOR Y C ONNE CT IONS “ A T G ” Anti- T ailgate This in put will stop the gate when ...

  • Viking Access Systems f1 gate - page 34

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 32 Viking Loop Rac k TIP: This op erator may be eq uippe d with a pre-wired Loop Rack that plug- in typ e loop detec t ors c an be co nne cted to. This provides a convenient a lternativ e to the box typ e loo p detectors that woul d nee d to be wired to t he control bo ard. Vi king do es not provide eithe r ...

  • Viking Access Systems f1 gate - page 35

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 33 Guidelines for Loop Installation Table C - Recommended Number of Turns Perimeter (ft.) Number of Turns 10 5 20 4 30-40 3 50-100 2 A C CESSOR Y C ONNE CT IONS 1 . Prev ent sha rp corne rs in the g eom etry of the lo op sen sor . 2 . Ins tall the a ppropriate num ber of tur ns for your lo op ge ometr y base ...

  • Viking Access Systems f1 gate - page 36

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 34 A C CESSOR Y C ONNE CT IONS ( + ) ( + ) ( + ) ( + ) Magnetic Lock Lock Solenoid Magnetic Lock , Lock Soleno id NOT E: Vi king Access Syst ems d oes not p ro vide externa l gate lock devices . The se items ca n be purch ased f rom your deal er or di stributor . Pow er f or the L ocks: Do not u se th ...

  • Viking Access Systems f1 gate - page 37

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 35 Barrier Arm ( B - 12) S ynchronization Option NOT E: Th e Control Bo ard provides a conv enie nt solution fo r appli cations that re quire synch roniz ed op eration with the Vik ing Ba rrier A rm Op erator mod el B-12 . This t ype of ap plication o pen s and cl oses in the foll owing pattern: 1 . Op en Co ...

  • Viking Access Systems f1 gate - page 38

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 36 LED Referenc es In ad dition to the L CD Disp lay , the co ntr ol bo ard LEDs mo nitor the variou s circuits of the control boa rd. Use the t able b elow to identif y the corresp ond ing “ TS Ref# ” a nd refer to page 38- 4 1 for further tr oubleshoot ing. TROUBL ESHOO T ING # LED Status Meaning Page ...

  • Viking Access Systems f1 gate - page 39

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 37 LED Referenc es Use the ta ble b elow to identif y the corresp ondi ng “ TS Ref# ” an d refer to page 3 8 -41 for fur ther t roubles hooti ng. TROUBL ESHOO T ING # LED Status Meaning Pg 41 TS R ef#(s ) 9 “C Loop” OFF Normal Condition. SOLID Control Board is receiving an input from a device connect ...

  • Viking Access Systems f1 gate - page 40

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 38 TROUBL ESHOO T ING LCD MSG Meaning Page 41 TS Ref #s VIKING ACCESS Welcome Message MODEL F1 Indicates the Model of the unit S yst em Status Messages GATE IS IDLE Gate is stopped between limits GATE IS OPENING Gate is opening GATE IS CLOSING Gate is closing GATE IS OPENED Gate is at the limit open position ...

  • Viking Access Systems f1 gate - page 41

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 39 TROUBL ESHOO T ING L CD Displa y Referenc es LCD MSG Meaning Page 41 TS Ref #s Multi Met er Displa ys MOT AMP __._ A This is the motor current amperage during operation MOT VOLT __._ VDC This is the actual motor voltage during operation AC VOLT __._ VAC This is the actual low voltage AC to the Control Boa ...

  • Viking Access Systems f1 gate - page 42

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 40 TROUBL ESHOO T ING L CD Displa y Referenc es LCD MSG Meaning Page 37 TS Ref #s Err or Messages ERR AC LOW Indicates that the 24VAC supply to the VFlex Board is too low from the 115/230 power supply. 1, 3, 20 ERR AC HIGH Indicates that the 24VAC supply to the VFlex Board is too high from the 115/230 power ...

  • Viking Access Systems f1 gate - page 43

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 41 TROUBL ESHOO T ING Soluti ons Be gin the troubl esho oting process by referring to the er ror mess ages o n the L CD Displ ay and/ o r the Status LEDs o n the control boa rd. Use pa ges 3 6- 40 to ide ntify the T roubl esho oting Referen ce # (TS Ref #) then referen ce the tab le bel ow . TS R ef# CHECK P ...

  • Viking Access Systems f1 gate - page 44

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 42 A c c ess C ontrol Connections Appe nd ix ( A ) Pow er C onnections The control bo ard provides a 24 VDC outp ut t o power external d evices and controls . Alternatively , fo r devices that requ ire a pow er sup ply other tha n 24 VDC , t h e ope rators Pow er B ox c ontai ns a conv enie nt 120V A ...

  • Viking Access Systems f1 gate - page 45

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 43 APPE NDIX ( A ) In General In rega rds to the Viking control bo ard, all externa l safet y devices and a ccess controls contain , an d are, sim ple relays that provide an inp ut to the Viking control boa rd when the device is ac tivat ed . Whe n these d evices are ac tivated, their intern al relays create ...

  • Viking Access Systems f1 gate - page 46

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 44 Common Radio R ec eiv ers - Connections Appe nd ix ( B ) Common Radio R ec eiv ers - Connections Appe nd ix ( B ) ...

  • Viking Access Systems f1 gate - page 47

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 45 Solar Applications NOT E: Vi king recom men ds Sol ar Packa ge ( pa rt # V A-SOCH P ) for most g ene ral sola r app lications . Altern ativ ely , individu al and th ird par ty so lar com pone nts c an be us ed. The follow ing are minimum system r equirement s and installation information. APPE NDIX ( C) I ...

  • Viking Access Systems f1 gate - page 48

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 46 VIKING EXP ANSION PRODUCTS VIKING SOL AR KIT The comp one nts in clude d in this pa ckage are intend ed to pro vide suf f icient power for g ene ral app lication s. Par t# V A-SOCH P This Kit includes the follo wing c omponents: (2) 12V 40W Solar Pa nel s Part# V A- SO40W (wired in s eries = 24V 80W) (2) ...

  • Viking Access Systems f1 gate - page 49

    OUR C ONTI NUOU S C OMM ITMENT T O E X CELLENC E Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and its needs. As technology continues to advance, we have developed a completely effi cient and intelligent line of gate operators to meet the changing demands. These machines offer: ...

  • Viking Access Systems f1 gate - page 50

    VIKI NG A CCESS SYSTEMS 63 1 W ald Irvine , CA 926 18 Phone 8 0 0.9 0 8. 08 8 4 F ax 949.7 53 .16 40 ww w . vikingacc ess.com ST AN D ARD FE A TURE S AND OPER A T OR SPE CIFICA TIONS • U L Liste d; U L 32 5 an d U L 99 1 • E TL Lis ted; UL 32 5 a nd UL 9 91 • Fail -Saf e op tion set s th e ga te to auto matic al ly tra ns fer to a fai l-s afe ...

Fabricante Viking Access Systems Categoría Safety Gate

Los documentos del dispositivo Viking Access Systems f1 gate que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Viking Access Systems
- manuales de instrucciones f1 gate
- hojas de producto Viking Access Systems
- folletos informativos
- o etiquetas energéticas Viking Access Systems f1 gate
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Viking Access Systems f1 gate.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Viking Access Systems f1 gate, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Viking Access Systems f1 gate. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Viking Access Systems f1 gate.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Viking Access Systems f1 gate, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Viking Access Systems f1 gate. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Viking Access Systems f1 gate.

El manual de instrucciones completo de Viking Access Systems debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Viking Access Systems f1 gate - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Viking Access Systems f1 gate, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Viking Access Systems f1 gate que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Viking Access Systems f1 gate - que deben facilitarnos los primeros pasos durante el uso de Viking Access Systems f1 gate
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Viking Access Systems f1 gate
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Viking Access Systems f1 gate en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Viking Access Systems f1 gate?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Viking Access Systems f1 gate, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Viking Access Systems f1 gate probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)