    1 A DIVISION OF A.O. SMITH CORPORA TION Mc BEE, SOUTH CAROLINA PLACE THESE INSTRUCTIONS ADJACENT T O HEA TER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. PRINTED IN U . S .A. 0206 Part Number 197279-000 W ARNING: If the information in these instructions is not followed exactly , a fire or explosion may result causing property damage, personal inj ...

  • A.O. Smith BPD-400 - page 2

    2 Input Ca pac ity SHIPPING B T U Gallon GAS WEIGHT Model (kw-H r . ) (Liters) " A " " B " " C " "D" "E " "F" " G" "H" " I" LINE ST D ASM E BPD - 400 390,000 95 82.25 80.25 30.25 8.75 4 or 6 21.75 63.50 2.25 58.00 1.00 9 00 lb s. 1 1 00 l bs . (1 14.3) (360) ( ...

  • A.O. Smith BPD-400 - page 3

    3 TYPICAL INST ALLA TION INT A KE FOR COMBUSTION AIR VENT TO OUTDOORS FLUE PRODUCTS DISCHARGE PIPE AIR INT AKE PIPE TEMPERA TURE PRESSURE RELIEF VA LV E V ACUUM RELIEF REQUIRED BY SOME CODES (REFER TO LOCAL CODES) SHUTOFF V AL V E COL D W A TER INLET MIXING V AL V E * TEMPERED W A TER OUTLET HOT W A TER OUTLET GAS SUPPL Y Installation Information: ...

  • A.O. Smith BPD-400 - page 4

    4 These designs comply with the current version of the American National S t andard for Gas W ater Heaters, V olume III, ANSI Z21.10.3 / CSA 4.3 as automatic circulating tank water heaters, and automatic storage water heaters. Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a referenc ...

  • A.O. Smith BPD-400 - page 5

    5 SERVED BY THIS HEA TER THA T HAS NOT BEEN USED FOR A LONG PERIOD OF TIME (GENERALL Y TWO WEEKS OR MORE). HYDROGEN GAS IS EXTREMEL Y FLAMMABLE. T o reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the ho ...

  • A.O. Smith BPD-400 - page 6

    6 foot of air . Therefore, the heater input rate should be reduced at high altitudes for satisfactory operation with the reduced oxygen supply . Failure to make this reduction would result in an over-firing of the heater causing sooting, poor combustion and/or unsatisfactory heater performance. Ratings specified by manufacturers for most appliances ...

  • A.O. Smith BPD-400 - page 7

    7 ROBER TSH A W 47484A PILO T SENSOR R O BER TSHA W DERHC-S7C NA TURAL 1" x 1" GAS V AL VE GAS V AL VE The gas valve is used to supply the gas to the unit during heat up periods. The ignition control module monitors the thermostat's call for heat and sends a signal to the gas valve when to open to allow gas flow. PRESSURE SWITCH The ...

  • A.O. Smith BPD-400 - page 8

    8 STEP DOWN TRANSFORMER The controls system utilizes a 120/24 V AC step down transformer. Most of the control system utilizes 24 V AC for operation. See wiring diagram for those components utilizing 24 V AC and 120 V AC. P1 20/24 V AC STEP DOWN TRANSFORMER BURNER TRA Y ASSEMBL Y The appliance is equipped with a user friendly burner tray assembly . ...

  • A.O. Smith BPD-400 - page 9

    9 HIGH LIMIT SWITCH The surface mounted high limit switch monitors the flue gases escaping through the blower assembly to ensure the temperatures do not exceed the rating for the CPVC/PVC vent pipe utilized on the venting. FIGURE 4 HIGH LIMIT SWITCH SHROUD ASSEMBL Y The shroud assembly protects the top of the appliance where the blower and junction ...

  • A.O. Smith BPD-400 - page 10

    10 CLEARANCES The unit is approved for installation on combustible flooring in an alcove when the minimum clearance to combustibles is maintained per Figure 6 and the table below . AB C D (RIGHT SIDE) (LEFT SIDE) (BACK) (CEILING) 0" (0cm) 0" (0cm) 0" (0cm) 12" (30.5 cm) A service clearance of 24" (61 cm) should be maintaine ...

  • A.O. Smith BPD-400 - page 11

    11 FIGURE 9 WIRE FENCE When the water heater outlet terminal is low enough to be touched accidentally , or is accessible to small children, a wire mesh chain link fence (as shown in Figure 9) may be used. Care should be taken to maintain adequate ventilation around the outlet terminal. If a chain link fence is installed, it must not be used as a st ...

  • A.O. Smith BPD-400 - page 12

    12 FIGURE 10 W A TER PIPING WARNING HOTTER W A TER CAN SCALD: W A TER HEA TERS ARE INTENDED T O PRODUCE HOT W A TER. W A TER HEA TED T O A TEMPERA TURE WHICH WILL SA TISFY CLOTHES W ASHING , DISH W ASHING , AND OTHER SANITIZING NEEDS CAN SCALD AND PERMANENTL Y INJURE YOU UPON CONT AC T . SOME PEOPLE ARE MORE LIKEL Y TO BE PERMANENTL Y INJURED BY HO ...

  • A.O. Smith BPD-400 - page 13

    13 FILLING THE W A TER HEA TER CAUTION NEVER USE THIS W A TER HEA TER UNLESS IT IS COMPLETEL Y FILLED WITH W A TER. T O PREVENT DAMAGE TO THE T ANK, THE T ANK MUST BE FILLED WITH W A TER. W A TER MUST FLOW FROM THE HOT WA TER F AUCET BEFORE TURNING "ON" GAS TO THE W A TER HEA TER. T o fill the water heater with water: 1. Close the water h ...

  • A.O. Smith BPD-400 - page 14

    14 WIRING DIAGRAM FOR ROBERTSHAW CONTROL SYSTEM - NATURAL GAS ONLY NOTE: If any of the original wire as supplied with the water heater must be replaced, it must be replaced with 105°C thermoplastic AWM wire or its equivalent. CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPER ...

  • A.O. Smith BPD-400 - page 15

    15 VENTING WARNING T O INSURE PROPER VENTING OF THIS GAS-FIRED W A TER HEA TER, THE CORRECT VENT PIPE DIAMETER MUST BE UTILIZED. ANY ADDITIONS OF OTHER GAS APPLIANCES ON VENT WITH THIS W A TER HEA TER ARE PROHIBITED AS THEY WILL ADVERSEL Y AFFECT THE OPERA TION OF THE W A TER HEA TER. WARNING OBSTRUCTED OR DETERIORA TED VENT SYSTEMS MA Y PRESENT SE ...

  • A.O. Smith BPD-400 - page 16

    16 VENTING (CONT'D) TYPICAL INSTALLATION - UP TO 110' (33.5 m) Follow illustration above if making an immediate horizontal run of vent off the blower fittings on top of the water heater . 1. The water heater requires its own (separate) venting system. 2. Only 6" CPVC Schedule 40 or 80 piping and fittings are acceptable materials for ...

  • A.O. Smith BPD-400 - page 17

    17 3. Minimum vent length is 18" (46 cm) when 4" pipe is used and 45' (13.7 m) when 6" pipe is used. CEMENTING PVC OR CPVC PIPE AND FITTINGS Read and observe all safety information printed on primer , cleaner , and cement containers. DANGER PRIMER, CLEANER, AND CEMENTS ARE EXTREMEL Y FLAMMABLE. THEY ARE HARMFUL OR F A T AL IF SW ...

  • A.O. Smith BPD-400 - page 18

    18 The 4" or 6" PVC Schedule 40 or CPVC Schedule 40 or 80 vent pipes can be run from the water heater through the wall or from the wall to the water heater , whichever is most convenient. The vent pipes must extend a minimum of 1 1/2" (3.8 cm) through the exterior wall. Extending the vent caps as far as possible from the surface of t ...

  • A.O. Smith BPD-400 - page 19

    19 CONNECTING VENT TO BLOWER - 6" VENT PIPING 1. If making an immediate horizontal run of vent off the blower , a 7 1/ 4" (18.4cm) min. long PVC Schedule 40 pipe section and an elbow are required for the inlet pipe. A 4" min. long CPVC Schedule 40 pipe section (supplied), one CPVC Schedule 40 or 80 regular elbow and one CPVC Schedule ...

  • A.O. Smith BPD-400 - page 20

    20 gas control valve could result in a fire or explosion from leaking gas. WARNING If the main gas line shutoff serving all gas appliances is used, also turn “OFF” the gas at each appliance. Leave all gas appliances shut off until the water heater installation is complete. CORRECT GAS PIPE SIZE FOR W A TER HEA TERS OPERA TING ON NA TURAL GAS TO ...

  • A.O. Smith BPD-400 - page 21

    21 Before attaching the gas line be sure that all gas pipe is clean on the inside. T o trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with the “Gas Piping” section. Refer to the current edit ...

  • A.O. Smith BPD-400 - page 22

    22 Before the water heater will operate: 1. The control system must be connected to a 1 10/120 power supply . This control system has an overall rating of 12 amps or less. The water heater must be securely and adequately grounded in accordance with the local codes or , in the absence of local codes, with the current edition of the National Electric ...

  • A.O. Smith BPD-400 - page 23

    23 A . This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. BEFORE OPERA TING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU SMELL GAS • Do not try to ...

  • A.O. Smith BPD-400 - page 24

    24 TEMPERA TURE REGULA TION DANGER HOT W A TER CAN SCALD: W A TER HEA TERS ARE INTENDED TO PRODUCE HOT W A TER. W A TER HEA TED TO A TEMPERA TURE THA T WILL SA TISFY SP ACE HEA TING , CLOTHES W ASHING , DISH W ASHING , AND OTHER SANITIZING NEEDS CAN SCALD AND PERMANENTL Y INJURE YOU UPON CONT ACT . SOME PEOPLE ARE MORE LIKEL Y T O BE PERMANENTL Y I ...

  • A.O. Smith BPD-400 - page 25

    25 SMOKE/ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while. THERMAL EXPANSION Water supply systems may, because of such events as high line pressure, frequent cutoffs, the effects of water hammer among others, ha ...

  • A.O. Smith BPD-400 - page 26

    26 pilot. If the water was extremely hot and is now cold, the high limit safety temperature shut off may have put out the burner and pilot. Refer to “High Temperature Shut Off System” in this section. 4. The gas control knob must be turned to the “ON” position. 5. The temperature adjustment dial may be set too low. See the “Temperature Re ...

  • A.O. Smith BPD-400 - page 27

    27 for cleaning, call the local gas utility to remove and clean the burner and correct the problem that required the burner to be cleaned. HOUSEKEEPING Vacuum around base of water heater for dust, dirt, and lint on a regular basis. WARNING TO INSURE SUFFICIENT VENTILATION AND COMBUSTION AIR SUPPLY, PROPER CLEARANCES FROM THE WATER HEATER MUST BE MA ...

  • A.O. Smith BPD-400 - page 28

    28 ONE TEMPERA TURE - ONE HEA TER HORIZONT AL ST ORAGE T ANK FORCED CIRCULA TION WITH OR WITHOUT BUILDING RECIRCULA TION DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE TEMPERA TURE A T FIXTURES. SEE W A TER TEMPERA TURE CONTROL W ARNING ON P AGE 24. IF HIGHER PREHEA T TEMPERA TURES ARE NECESSARY T O OBT AIN ADEQUA TE BOOSTER OUTPUT , ADD AN ANT ...

  • A.O. Smith BPD-400 - page 29

    29 * PIPE RELIEF V AL VE TO OPEN DRAIN. NOTE: IF TEMPERED WA TER IS RECIRCULA TED, RETURN LINE SHOULD BE CONNECTED A T POINT “A”. INST ALL IN ACCORDANCE WITH LOCAL CODES. TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE TEMPERA TURE A T FIXTURES. SEE W AT ...

  • A.O. Smith BPD-400 - page 30

    30 TWO TEMPERA TURE - TWO HEA TERS HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION TWO TEMPERA TURE - THREE HEA TERS (TWO PRE-HEA TERS/ONE BOOSTER HEA TER) WITH OR WITHOUT BUILDING RECIRCULA TION MUST BE IDENTICAL HEA TERS FOR MUL TIPLE HEA TER INST ALLA TION SEE MANIFOLD KIT SPECIFICA TIONS, P AGE 33. CAUTION : IF BUILDING COLD W A TER S ...

  • A.O. Smith BPD-400 - page 31

    31 * PIPE RELIEF V A L VE TO OPEN DRAIN * * 140°F (60°C)TO 150°F (66°C) SHOULD BE MAXIMUM WA TER TEMPERA TURE MAINT AINED IN THE PRE-HEA TERS. 120°F (49°C) SHOULD BE THE MINIMUM TEMPERA TURE OF W A TER IN THE PRE- HEA TERS. CONNECT CIRCULA TING LINE FROM FIXTURES, IF USED, T O COLD W A TER SUPPL Y LINE OF PRE-HEA TER. CONNECT CIRCULA TING LIN ...

  • A.O. Smith BPD-400 - page 32

    32 NOTE 1: TOGGLE SWITCH CONTROLS 180°F (82°C) W ATER CIRCULA TION. INST ALL ON OR CLOSE TO DISHW ASHER. TOGGLE SWITCH MUST BE CLOSED (ON) DURING THE RINSE OPERA TION AND OPEN (OFF) WHEN DISHW ASHER IS NOT OPERA TING OR WHEN ON LONG ST ANDBY . NOTE 2: INST ALL LINE TEMPERA TURE CONTROL IN AN UNINSULATED TEE BEYOND THE DISHWASHER T AKEOFF IN THE S ...

  • A.O. Smith BPD-400 - page 33

    33 MANIFOLD KITS Precision cut type “L” all copper A.O. Smith manifold kits assure water flow balance of all units. Without this balance, the full water heating and storage potential of the system cannot be achieved. Plus, the units with the higher water flow may have a shortened life. Unions shown in piping diagrams are not included in the man ...

  • A.O. Smith BPD-400 - page 34

    34 SEDIMENT REMOVAL Waterborne impurities consist of the particles of soil and sand which settle out and form a layer of sediment on the bottom of the tank. For convenience, sediment removal and lime scale removal should be performed at the same time. LIME SCALE REMOVAL The amount of calcium carbonate (lime) released from water is in direct proport ...

  • A.O. Smith BPD-400 - page 35

    35 Model BPD 400 Limited Warranty A. O. Smith Corporation, the warrantor, extends the following LIMITED W ARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the first THREE years ...

  • A.O. Smith BPD-400 - page 36

    36 A.O. SMITH WATER PRODUCTS CO. 500 T ennessee Waltz Parkw a y, Ashland City, TN 3701 5 PHONE: 1-800-433-2545 • FAX: 1-800- 433-2515 www.hotwater.com / email: parts@hotwater.com ...

Fabricante A.O. Smith Categoría Water Heater

Los documentos del dispositivo A.O. Smith BPD-400 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos A.O. Smith
- manuales de instrucciones BPD-400
- hojas de producto A.O. Smith
- folletos informativos
- o etiquetas energéticas A.O. Smith BPD-400
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones A.O. Smith BPD-400.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje A.O. Smith BPD-400, instrucciones de servicio, instrucciones cortas o instrucciones de usuario A.O. Smith BPD-400. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto A.O. Smith BPD-400.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo A.O. Smith BPD-400, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar A.O. Smith BPD-400. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de A.O. Smith BPD-400.

El manual de instrucciones completo de A.O. Smith debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual A.O. Smith BPD-400 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice A.O. Smith BPD-400, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de A.O. Smith BPD-400 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo A.O. Smith BPD-400 - que deben facilitarnos los primeros pasos durante el uso de A.O. Smith BPD-400
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con A.O. Smith BPD-400
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de A.O. Smith BPD-400 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de A.O. Smith BPD-400?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con A.O. Smith BPD-400, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con A.O. Smith BPD-400 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)