Manual de instrucciones Micro Technic PV-1700

21 de páginas 0.27 mb
Descargar

Pasar a la página of 21

Summary
  • Micro Technic PV-1700 - page 1

    Micro Technic A -S • Den mark • Tel. +45 66 15 3000 • Fax +45 6615 3077 E-mail: suppo rt@micro-technic.co m Website: www. micro-technic.co m M ICRONIX PC/104 P OWER S UPPLY PV-1700, 1800 SERIES 20W Power Supply including GSM/ GPRS modem, analogue and digital I/O channels V ER . 1.0 Ver. 1.2 DOC: M5258DM User Manual & Installat ion Guide ...

  • Micro Technic PV-1700 - page 2

    Page 2 / 21 Table of contents GENERAL INFORMATION .......................................................................................................................................... 2 O RDERING CODES ............................................................................................................................................... ...

  • Micro Technic PV-1700 - page 3

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 3 / 21 General informati on Ordering codes Options Ordering no Model no -S - Power Supply Modem Analog inputs Digital inputs Digital outputs RS232 PV-1700 -1 016.104.138 016.104.139 PV-1700 -2 016.104.140 016.104.141 PV-1700 -3 016.104.142 016.104.143 PV-1700 -4 ...

  • Micro Technic PV-1700 - page 4

    Page 4 / 21 Accessories These accessories must be ordered separately if needed. Model no Ordering code Description GSM cable 126.033.000 RG136 cable with MMCX-S MA MALE 140mm GSM Antenna 060.302.001 GSM antenna with SMA co nnector CM-2 425.104.001 Mains cable with one crim p connector m ating KL1, 30c m CDB-9M 425.104.002 Cable with one DSUB9 m ale ...

  • Micro Technic PV-1700 - page 5

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 5 / 21 Description The PV-1800, the fully equipped model, offers the following features: • a PC/104 20W power suppl y +5V, 4A. • a dual band GSM/GPRS modem (Son y Ericsson GM47) • 8 isolated analogue inputs, 12 bit • 8 digital inputs, opto-isolated • 7 ...

  • Micro Technic PV-1700 - page 6

    Page 6 / 21 The digital I/O section is found on all models except PV-1830 and PV-1730 versions. The digital inputs are bipolar isolated with a max. input voltage of +/- 30V. There are 7 isolated digital P-channel outputs each capable of drivin g up to 0.5A. The load current must be supplied from an external voltage source not exceeding 30V. The UPS ...

  • Micro Technic PV-1700 - page 7

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 7 / 21 Power Supply The on-board power supply consists of a synchronous step-down switching regulator with an efficiency of 85-95%, depending on input voltage and load current. At nomi nal input voltage (24V DC) and a load current of 2A the efficiency is 92%. A ...

  • Micro Technic PV-1700 - page 8

    Page 8 / 21 This table is also printed on the board. The IRQ used for the modem is set in section I RQ_A. Place one jumper in this section to select an IRQ number in the interval IRQ3 to IRQ15. SIM card The SIM card connector (CN9) is placed on the rear side of the module. A S IM card must be placed in this connector in order to establish a wireles ...

  • Micro Technic PV-1700 - page 9

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 9 / 21 AT commands All functions of the modem are carried out by AT commands from a computer application. For documentation of the AT command set please see “Integrators Manual” for GM47 from Son y Ericsson, at http://www.eurodis.com/wireless/htm/suppl iers_ ...

  • Micro Technic PV-1700 - page 10

    Page 10 / 21 Function Pin no CN9 Pin no CDB-9M I/O GND 1 5 RI 2 9 I DTS 3 4 O CTS 4 8 I TxD 5 3 O RTS 6 7 O RxD 7 2 I DSR 8 6 I CD 9 1 I N.C. 10        . +  1 # +%  5     = &  6 ...

  • Micro Technic PV-1700 - page 11

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 11 / 21 Analogue inputs (CN5) The PV-1800 and PV-1700 has 8 isolated analogue inputs accessible in a 10pin box header (CN5). Beside these inputs, there is also a +3.3V isolated voltage with common ground reference as the analogue inputs. This voltage can be used ...

  • Micro Technic PV-1700 - page 12

    Page 12 / 21 Digital inputs (CN 1) All models, except PV-1830 and PV-1730 has 8 isol ated digital inputs connected to a 10-pin box header (CN1). All the inputs have ac-couplers with a common ground reference. Because of the ac- couplers, the inputs can be activated with positive as well as negative input voltages. The table shows the connector layo ...

  • Micro Technic PV-1700 - page 13

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 13 / 21 Digital outputs (CN2) The digital section has 7 isolated digital outputs connected to a 10pin box header (CN2). The outputs are configured as PNP outputs wit h their transistors connected to an external supply voltage (+V_EXT). The table shows the connec ...

  • Micro Technic PV-1700 - page 14

    Page 14 / 21 UPS signals (CN7) Modules with onboard DC/DC converter has signals that, combined with e xternal circuitry, can be used to implement a UPS function. There is an input for turning off the 20W power supply (SWITCHER_OFF), two status inputs (UPS_S TATUS1 and UPS_STATUS2), and an output (UPS_PWROFF) that can tell the external circuitry to ...

  • Micro Technic PV-1700 - page 15

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 15 / 21 Internal registers Address Access Name Function Base+0 Read onl y REG_SIGN Signature (8Ch) Base+1 Read onl y REG_MODEL Model Base+2 Read/write REG_DIGOUT Digital outputs Base+3 Read onl y REG_DIGIN Digital inputs Base+4 Read onl y REG_CNTLO Counter LSB B ...

  • Micro Technic PV-1700 - page 16

    Page 16 / 21 REG_CNTMODE (base+6): Counter configuration (read/write) The counter starts at 0000h after system reset. It cannot be reset or reload ed from software. Bits: 000000 cc cc = counter mode (read/write): 00 = counter disabled, DI0 and DI1 are ignored 01 = counts rising edges of DI0 10 = counts falling edges of DI0 11 = quadrature counter o ...

  • Micro Technic PV-1700 - page 17

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 17 / 21 REG_ADCLO (base+0Ah): ADC command, status, and result low b y te (read/write) Writing to this register starts a new A/D conversion. You should onl y do this when the ADC is idle. Command bits: 0000 dccc d : 0:single-ended, 1=differential ccc : Channel. d ...

  • Micro Technic PV-1700 - page 18

    Page 18 / 21 Technical data Power supply Input voltage (nominal) 8 – 27Vdc. Input voltage (MAX) 35Vdc. Output voltage 5Vdc External load Up to 4A, depending on configuration and thermal conditions. UPS interface: 4 pins in CN7 Run/stop, AUX1,AUX2,AUX3 (factor y use onl y). GSM-modem: Modem type GM47 (Son y Ericsson). SIM card interface 3V or 5V F ...

  • Micro Technic PV-1700 - page 19

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 19 / 21 Max input voltage 30V, current limiti ng resistor = 3.32kohm / 250mW Counter input DI0 can act as a 16-bit up-counter by counting positive or negative edges (configurable) DI0 and DI1 can act as a 16-bit quadrature counter. Max counting rate 10kHz Connec ...

  • Micro Technic PV-1700 - page 20

    Page 20 / 21 Mechanical Lay o ut This schematic shows the dimensions for PV-1800. All dimensions are in mm. ...

  • Micro Technic PV-1700 - page 21

    Users Manual & Installation Guide PV- 1800: Power supply module with GSM MODEM Page 21 / 21 Installation guide Precautions to ESD Please note that the Micronix PV modules must be handled with respect to ESD (Electrostatic Discharge). Electrostatic Discharge to the PV modules must be avoided. Before removing the module from the protection bag, t ...

Fabricante Micro Technic Categoría Power Supply

Los documentos del dispositivo Micro Technic PV-1700 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Micro Technic
- manuales de instrucciones PV-1700
- hojas de producto Micro Technic
- folletos informativos
- o etiquetas energéticas Micro Technic PV-1700
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Micro Technic PV-1700.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Micro Technic PV-1700, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Micro Technic PV-1700. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Micro Technic PV-1700.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Micro Technic PV-1700, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Micro Technic PV-1700. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Micro Technic PV-1700.

El manual de instrucciones completo de Micro Technic debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Micro Technic PV-1700 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Micro Technic PV-1700, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Micro Technic PV-1700 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Micro Technic PV-1700 - que deben facilitarnos los primeros pasos durante el uso de Micro Technic PV-1700
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Micro Technic PV-1700
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Micro Technic PV-1700 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Micro Technic PV-1700?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Micro Technic PV-1700, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Micro Technic PV-1700 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)