Manual de instrucciones Sierra Not available

17 de páginas 0.3 mb
Descargar

Pasar a la página of 17

Summary
  • Sierra Not available - page 1

    Series 240/241 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM- 90- 1 0 7 /0 5 Revision D.1 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 ht tp :/ / www.s ie rr ain st ru me nt s. co m Sierra Instruments b.v. Bolstoen 30A 1046 ...

  • Sierra Not available - page 2

    Series 900 Single & Dual Instruction Manual Page 16 © COPYRIGHT SIERRA INSTRUMENTS 1994 No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language, in any form or by any means, electronic, mechanical, manual, or otherwise, or disclosed to t ...

  • Sierra Not available - page 3

    Series 900 Single & Dual Instruction Manual Page 15 1 . Introduction ............................................................................. 1 2. Locating System Electronics .................................................. 2 3. Front Panel Functions ............................................................ 3 3.1 Channel Selection ... ...

  • Sierra Not available - page 4

    Series 900 Single & Dual Instruction Manual Page 1 The Sierra Instruments, Inc. Single and Dual Channel System Electronics is a highly integrated systems solution to flow mea- surement and control. One or two independent flow meters or controllers can be operated simultaneously. Linear operation with LCD readout is standard. The back panel conn ...

  • Sierra Not available - page 5

    Series 900 Single & Dual Instruction Manual Page 2 The System Electronics should be located in a room-temperature location which is dry and dust-free. Use cable lengths in accor- dance with the guidelines given with your transducer. Excessive cable lengths will impair operation of both the System Electronics and the transducer. Extremes of temp ...

  • Sierra Not available - page 6

    Series 900 Single & Dual Instruction Manual Page 3 System Electronics’s front panel controls provide ease of opera- tion. To get the most benefit from a Sierra Instruments, Inc. System Electronics, read these instructions before attempting operation. On dual channel units, the rotary switch labeled Channel Select determines which channel is d ...

  • Sierra Not available - page 7

    Series 900 Single & Dual Instruction Manual Page 4 As the potentiometer is rotated the appropriate alarm setpoint is varied from zero to the full scale flow value and displayed in the front LCD display. The totalize option records the total mass flow. This value is indicated on the front panel electronic counter and is therefore immune to power ...

  • Sierra Not available - page 8

    Series 900 Single & Dual Instruction Manual Page 5 The AC power line connector (or power entry module) is located on the back panel. A cordset is supplied with the System Electronics and is compatible with wall outlets in the USA. Be sure System Electronics is wired for the proper power mains voltage, either 115 VAC, 60 Hz or 230 VAC, 50/60 Hz, ...

  • Sierra Not available - page 9

    Series 900 Single & Dual Instruction Manual Page 6 The VALVE PURGE function is activated by the VALVE TP (test point) pin. When this pin is connected to common, the valve is fully open regardless of setpoint. This pin must source 150 mA of current when driven to common. If a voltmeter is connected between this pin and –15 VDC, the voltage acr ...

  • Sierra Not available - page 10

    Series 900 Single & Dual Instruction Manual Page 7 Normally each System Electronics is carefully set-up at Sierra Instruments and needs no maintenance. Individual transducers may need periodic maintenance. Refer to transducer manuals for the proper procedure. The full scale value of the display can be adjusted using the Display Adjustment Poten ...

  • Sierra Not available - page 11

    Series 900 Single & Dual Instruction Manual Page 8 GENERAL System Electronics Powers/Reads up to two transducers. Flow, Setpoint, High Alarm, and Low Alarm directly displayed in engineering units. (Linear models). Outputs 0-5 volts and 4-20 mA for each channel. Valve control functions of Close/Purge/Monitor. Built-in 10 turn precision setpoint ...

  • Sierra Not available - page 12

    Series 900 Single & Dual Instruction Manual Page 9 APPENDIX B Back Panel Connector Pin Assignments; 20-Pin Transducer Connector KEY ▼ (View of connector from back of enclosure) PIN NO. FUNCTION PIN NO. FUNCTION A Setpoint Output to 1 Chassis Ground Controllers 2 Common B Common 3 0-5 Volt Signal from C Common Transducer D Valve Test Point 4 + ...

  • Sierra Not available - page 13

    Series 900 Single & Dual Instruction Manual Page 10 KEY ▼ APPENDIX C Back Panel Connector Pin Assignments; 26-Pin I/O Connector (View of connector from back of enclosure) PIN NO. FUNCTION PIN NO. FUNCTION A Channel 1, 0-5 Volt 1 Common Linear Output 2 Common B Channel 2, 0-5 Volt Linear Output 3 Common C Channel 1, Automatic 4 Common Setpoint ...

  • Sierra Not available - page 14

    Series 900 Single & Dual Instruction Manual Page 11 The alarms are a normally, open collector transistor outputs; that is, a transistor is used as a switch to ground. A “High” alarm means that if the flow signal is higher than the alarm trip setting, the transistor will be turned on. Conversely, a “Low” alarm activates the transistor wh ...

  • Sierra Not available - page 15

    Series 900 Single & Dual Instruction Manual Page 12 APPENDIX E Wiring Guide ...

  • Sierra Not available - page 16

    Ra ti o C o n t ro l O p ti o n Appendix F T he con st ant ra t io -c ont r ol op t ion (“- RC” in th e m od el co de ), pr ov i de s th e use r wi t h t he ab i lit y to set an d m ai nt ai n an exa ct rat i o of ga s f lo w be t we en t wo (or mo re ) m ass fl ow con tr ol l er s (M F Cs) . The con t ro l bo x ac com p li s he s t hi s by sca ...

  • Sierra Not available - page 17

    d. T urn of f t h e po we r swi t ch on th e f ro nt o f th e box, att a ch the cab l es and t he co ntr ol l er s (i f yo u h av en ’t alr ea dy do ne so ), an d t ur n t h e po we r o n. e. A pp l y gas pr es sur e to t he in let of t he con t ro l ler s per th e op er at i ng pre ss ur e li st e d on th e l ab el s. f . B ox sett i n gs: Set / ...

Fabricante Sierra Categoría Film Camera

Los documentos del dispositivo Sierra Not available que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Sierra
- manuales de instrucciones Not available
- hojas de producto Sierra
- folletos informativos
- o etiquetas energéticas Sierra Not available
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Sierra Not available.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Sierra Not available, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Sierra Not available. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Sierra Not available.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Sierra Not available, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Sierra Not available. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Sierra Not available.

El manual de instrucciones completo de Sierra debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Sierra Not available - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Sierra Not available, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Sierra Not available que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Sierra Not available - que deben facilitarnos los primeros pasos durante el uso de Sierra Not available
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Sierra Not available
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Sierra Not available en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Sierra Not available?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Sierra Not available, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Sierra Not available probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)