Manual de instrucciones TANDBERG 119076.02

22 de páginas 6.92 mb
Descargar

Pasar a la página of 22

Summary
  • TANDBERG 119076.02 - page 1

    P AGE 1/22 T ANDBER G T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 ROOM REQUIREMENTS The Room Requirements Description presents the room dimensions requirements, weights, wall- and ceiling loads, power outlet requirements as well as the heating, ventilation and air -conditioning (HV AC) requirements for the T ANDBERG T elepres ...

  • TANDBERG 119076.02 - page 2

    P AGE 2/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 SYSTEM DIMENSIONS 1658 65 1 4 " T3 system dimensions 2800 110 1 4 " 1650 65 " 1650 65 " 1500 59 " 2500 65 3 8 " 120 4 3 4 " 724 28 1 2 " 5 8 4800 189 " ...

  • TANDBERG 119076.02 - page 3

    P AGE 3/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 ROOM DEPTH REQUIREMENTS OPTIMAL AND MAXIMAL DEPTH 140 5 1 2 " 4600 181 1 8 " 4880 192 1 8 " 1015 40" 1000 39 3 8 " 1300 51 1 8 " Centerline Baseline Optimal room depth 2800 110 1 4 " 140 5 1 2 " 500 19 3 4 " The 1300 ...

  • TANDBERG 119076.02 - page 4

    P AGE 4/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 MINIMUM ROOM DEPTH REQUIREMENTS 140 5 1 2 " 4120 162 1 4 " 4400 173 1 4 " 1015 40" 1000 39 3 8 " 1300 51 1 8 " Centerline Baseline Min. room depth 2800 110 1 4 " 140 5 1 2 " 20 3 4 " Observe ...

  • TANDBERG 119076.02 - page 5

    P AGE 5/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 MINIMUM ROOM WIDTH REQUIREMENTS Centerline Min room width 4800 189 " 6645 261 " 5 8 922,5 36 " 3 8 922,5 36 " 3 8 85 3 8 3 " 6815 268 " 1 4 85 3 8 3 " Observe that the room should not have a smaller width than shown since that ...

  • TANDBERG 119076.02 - page 6

    P AGE 6/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 OPTIMUM AND MAXIMUM ROOM HEIGHT 2360 92 7 8 " 190 7 1 2 " 2550 100 3 8 " optimal room height Note that the room is shown with the T elepresence T3 system installed. ...

  • TANDBERG 119076.02 - page 7

    P AGE 7/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 MINIMUM ROOM HEIGHT REQUIREMENTS 2360 92 7 8 " 40 1 5 8 " 2400 94 1 2 " minimum room height Note that the room is shown with the T elepresence T3 system installed. ...

  • TANDBERG 119076.02 - page 8

    P AGE 8/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 MAXIMUM ROOM HEIGHT 2360 92 7 8 " 290 11 3 8 " 2650 104 3 8 " maximum room height Note that the room is shown with the T elepresence T3 system installed. ...

  • TANDBERG 119076.02 - page 9

    P AGE 9/22 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 HV AC REQUIREMENTS The following HV AC (heating, ventilation, air -conditioning) requirements apply to the T ANDBERG T elepresence T3: • Power consumption System: 1725 W • Power consumption T able: 300 W • Power consumption Lighting: 1300 W • ...

  • TANDBERG 119076.02 - page 10

    P AGE 10/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 Centerline Baseline 320 12 5 8 " 2247 88 1 2 " 2100 82 5 8 " 150 5 7 8 " 2025 79 3 4 " 675 26 5 8 " 2280 89 3 4 " Make sure that HV AC mounting neither conflicts with the ceiling lights positions nor the document camera posit ...

  • TANDBERG 119076.02 - page 11

    P AGE 11/22 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 ACOUSTICS REQUIREMENTS It is essential to have a good acoustic environment for the system to provide the true telepresence experience. This means that there should be sufficient sound insulation to minimize noise from adjacent rooms and to ensure that confide ...

  • TANDBERG 119076.02 - page 12

    P AGE 12/22 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 POWER OUTLET FUSE REQUIREMENTS The following minimum power outlet fuse requirements apply to the T ANDBERG T elepresence T3: ITEM W A TT PLACEMENT FUSE ON/OFF SWITCH T1 Mo dul e × 3 24 0 0 Ba ck wall A 1 Pr es en ta ti on sp li t ter × 2 6 0 Bac k wall A 1 T ...

  • TANDBERG 119076.02 - page 13

    P AGE 13/22 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 ELECTRONIC VERSIONS OF TECHNICAL DRA WINGS The technical drawings on the following pages are also available in electronic formats as pdf, dwg and dxf. T o obtain copies of these drawings, send an e-mail to tandberg@tandberg.com The following drawings are availa ...

  • TANDBERG 119076.02 - page 14

    P AGE 14/22 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 320 12 1 2 " 2247 88 1 2 " 2100 82 1 2 " 150 6" 2025 79 1 2 " 675 26 1 2 " 1000 39 1 2 " 1000 39 1 2 " 4930 194" 2240 88" Centerline Area where installation of aircondition should be avoided Installation area for ceiling mounted document ...

  • TANDBERG 119076.02 - page 15

    P AGE 15/22 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 140 5 1 2 " 140 5 1 2 " 4600 181 1 8 " 85 3 3 8 " 85 3 3 8 " 111 4 3 8 " 1695 66 3 4 " 885 34 7 8 " 400 15 3 4 " 885 34 7 8 " 1885 74 1 4 " 2160 85" 570 22 1 2 " 760 29 7 8 " 829 32 5 8 " 87,5 3 3 8 " Centerl ...

  • TANDBERG 119076.02 - page 16

    P AGE 16/22 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 140 5 1 2 " 140 5 1 2 " 4600 181 1 8 " 85 3 3 8 " 85 3 3 8 " 111 4 3 8 " 1695 66 3 4 " 885 34 7 8 " 400 15 3 4 " 885 34 7 8 " 1885 74 1 4 " 2160 85" 570 22 1 2 " 760 29 7 8 " 829 32 5 8 " ...

  • TANDBERG 119076.02 - page 17

    P AGE 17/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 1115 44" 1112,50 44" 85 3 1 2 " 3512,50 138 1 2 " 140 5 1 2 " 140 5 1 2 " 4098,50 161 1 2 " 2250 88 1 2 " 740 29" 10 1 2 " 20 1" 2400 94 1 2 " 4600 181" Centerline Optional Second row rear edge of ...

  • TANDBERG 119076.02 - page 18

    P AGE 18/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 2360 93" 955 37 1 2 " 625 24 1 2 " 945 37" 300 12" 1900 75" 2025 79 1 2 " 300 12" Frame around area for insulation boards Gap between the vertical lattices 300 - approx. 600mm 977 38 1 2 " ...

  • TANDBERG 119076.02 - page 19

    P AGE 19/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 2360 93" 2260 89" 2090 82 1 2 " 3056,70 120 1 2 " 3596,70 141 1 2 " 1485 58 1 2 " Centerline Area for mounting/changing Led Frame around area for insulation boards 04.11.08 01 T3 Long Structure 119087 Doc. Title: Sign.: Date: Revis ...

  • TANDBERG 119076.02 - page 20

    P AGE 20/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 T ANDBERG T elepresence T3 A A 75 3" 2132 84" 3833 151" 98,50 4" 615 24" 1557 61 1 2 " 3757 148" 80 3" 1193 47" Center line Base openings Base opening Base opening Structural element Structual element Floor power out ...

  • TANDBERG 119076.02 - page 21

    P AGE 21/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 50 2" 2000 78 3 4 " 2280 89 3 4 " 724 28 1 2 " 2550 100 3 8 " D Optimal height / suspended ceiling Picture center 20 3 4 " 69 2 3 4 " DETAIL D SCALE 1 : 5 Removable baseboard for access to outlets. Mounted with magnets. Power ...

  • TANDBERG 119076.02 - page 22

    P AGE 22/22 T ANDBERG T elepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 140 5 1 2 " 4600 181 1 8 " 85 3 3 8 " Centerline On Floor Cable Routing - Transport cables from T3 Power / AV / Lan Video Lan Customers Lan Master Panel Fire Emergency switch (Controls fuse groups A,B and C) Light Control Data Panel On floor Cabl ...

Fabricante TANDBERG Categoría Home Theater System

Los documentos del dispositivo TANDBERG 119076.02 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos TANDBERG
- manuales de instrucciones 119076.02
- hojas de producto TANDBERG
- folletos informativos
- o etiquetas energéticas TANDBERG 119076.02
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones TANDBERG 119076.02.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje TANDBERG 119076.02, instrucciones de servicio, instrucciones cortas o instrucciones de usuario TANDBERG 119076.02. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto TANDBERG 119076.02.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo TANDBERG 119076.02, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar TANDBERG 119076.02. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de TANDBERG 119076.02.

El manual de instrucciones completo de TANDBERG debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual TANDBERG 119076.02 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice TANDBERG 119076.02, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de TANDBERG 119076.02 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo TANDBERG 119076.02 - que deben facilitarnos los primeros pasos durante el uso de TANDBERG 119076.02
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con TANDBERG 119076.02
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de TANDBERG 119076.02 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de TANDBERG 119076.02?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con TANDBERG 119076.02, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con TANDBERG 119076.02 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)