Manual de instrucciones MRV Communications EM316E3SF

19 de páginas 0.37 mb
Descargar

Pasar a la página of 19

Summary
  • MRV Communications EM316E3SF - page 1

    EM316E3 EM316E3SF E3 Fiber Modem Fiber Driver Module User’s Guide ...

  • MRV Communications EM316E3SF - page 2

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 2 Registration Card Your name: Mr./Ms____________ _______________________________ Organization: _________________ _______Dept. __________________ Your title at organization:__ __________________ __________________ Telephone: _____________ ______________ Fax:__________________ Organiz ...

  • MRV Communications EM316E3SF - page 3

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 3 EM316E3 EM316E3SF E3 Fiber Modem Fiber Driver Module User’s Guide ...

  • MRV Communications EM316E3SF - page 4

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 4 TABLE OF CONTENTS 1 INTRODUCTION 2 HARDWARE INSTALLATION 3 TROUBLESHOOTING 4 TECHNICAL SPECIFICATIONS 5 CONTACT INFORMATION 6 GLOSSARY 7 ORDERING INFORMATION ...

  • MRV Communications EM316E3SF - page 5

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 5 1 INTRODUCTION About this Manual Before unpacking please refer to section 2 (Hardware Installation) This manual is a guide to the installati on and operation of the EM316E3 Fiber modem. Product description describes the product, it s functions, features, protocol supported, minimum ...

  • MRV Communications EM316E3SF - page 6

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 6 Features • E3 conversion between coax media and fiber media • Supports ITU-T G.703, ITU-T G.823, and HDB3 standards • Supports Local, Remote and Line Loop back Test • Up to 100km Transmission on Single Mode or 7km on Multimode Fiber • Modules can be Inserted / Removed wit ...

  • MRV Communications EM316E3SF - page 7

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 7 Display Information (LED Definition) • PWR: illuminates when unit is powered (green colo r) • LPBK: illuminates (yellow color) when loca l loop back o n both interfaces is enabled, OFF (no light or green color) when in normal mode • C: illuminates when E3 (coax) interface det ...

  • MRV Communications EM316E3SF - page 8

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 8 Configuration Jumper Settings: (Factory Default) CONFIGURING THE SWITCH (S1) SWITCH SETTINGS RESULTS *ON Force switches selections (loop back) regard less of NMS command MAN/NMS OFF Default setting comes from switches afte r power up, but maybe change by NMS commands SEC/PRI ON/OFF ...

  • MRV Communications EM316E3SF - page 9

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 9 Theory of Operation Block diagram of the Modem/Converter is shown below (fig. 1) Fig. 1 Block Diagram of EM316DS3 E3 Line Receiver to fiber optic Transmitter : The receiver Line Interface Unit (LIU) receives the E3 signal an d performs clock recovery and data detection. The data go ...

  • MRV Communications EM316E3SF - page 10

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 10 Switch LPBK/NORM is set to OFF Switch LPBK/NORM is set to OFF Loop Back Control: By NMS command or manually by a switch Loop back can be forced regardless of management by turning switch 1 MAN/NMS to ON and switch 3 NORM/LPBK to ON. NOTE: It is also possible to configure an extern ...

  • MRV Communications EM316E3SF - page 11

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 11 2 HARDWARE INSTALLATION PREP ARA TION STEP 1 Follow all Safety Regulations 1 Eliminate static electricity in the workplace by grounding operators, equipment, and devices (components and computer boards). Groundi ng prevents static charge buildup and electrostatic potential differe ...

  • MRV Communications EM316E3SF - page 12

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 12 f) ESD protective floor or mat: The mat must be grounded through a current- limiting resistor. The floor or mat dissip ates the static charge of personnel approaching the workbench. Special conduc tive tile or floor treatment can be used when mats are not practical or cau se a saf ...

  • MRV Communications EM316E3SF - page 13

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 13 UNIT INSTALLATION STEP 1 Remove required amount of bla nk panels from the NC316BU-xx. NOTE : Per FCC regulations, either a panel or a module should always cover chassis slots. FIGURE 1.1 Take out the required amount of blank panels. STEP 2 Align the edges of the EM316 module to th ...

  • MRV Communications EM316E3SF - page 14

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 14 STEP 3 Insert the module into the NC316BU-xx unit NOTE: To avoid dam aging any components on the m odule, handle it by the edges, using your thumb to push it securely inside the ch assis. Do not use excessive force, but make sure the module is fully inserted in the chassis. W hen ...

  • MRV Communications EM316E3SF - page 15

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 15 3 TROUBLESHOOTING The Fiber Driver series are highly reliable units. If there are any operating problems, the fault probably lies in some other aspect of the configuration. However, if after following the troubl eshooting steps below (in order), you find that the unit is still not ...

  • MRV Communications EM316E3SF - page 16

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 16 4 TECHNICAL SPECIFICATIONS Electrical 5VDC @ 2 Amps Max Hot Swappable Operating Temperature Range 0 ° C - +50 ° C (32 ° F – 122 ° F) Storage temp -10 ° C - +60 ° C (14 ° F – 140 ° F) Relative Humidity 85% maximum non-condensing Emissions Compliance FCC Part 15, Subpart ...

  • MRV Communications EM316E3SF - page 17

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 17 5 CUSTOMER SUPPORT Contact Information If you have any questions, please do not hesitate to contact us at: Americas Support MRV (East Coast USA) 295 Foster Street Littleton, MA 01460-2016 Tech Support: (800) 338-5316 Tech Support: (978) 952-4700 E-mail: support@fiberdriver.com Fax ...

  • MRV Communications EM316E3SF - page 18

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 18 5 GLOSSARY Complete definition of networking term s (jargon) used in this manual, may be found on our ftp site: ftp://ftp.fiberdriver.com/pub/doc/Glossary.pdf 6 ORDERING INFORMATION Please visit us at http://www.fiberdriver.com for the latest updates on our products. Fiber Driver ...

  • MRV Communications EM316E3SF - page 19

    Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 19 Place Stamp Here ---------- -------- -------- ---------- -------- ---- ---------- -------- -------- ---------- -------- ---- ---------- -------- -------- ---------- -------- ---- 8928 Fullbright Avenue Chatsworth, California 91311 U . S . A . ...

Fabricante MRV Communications Categoría Network Card

Los documentos del dispositivo MRV Communications EM316E3SF que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos MRV Communications
- manuales de instrucciones EM316E3SF
- hojas de producto MRV Communications
- folletos informativos
- o etiquetas energéticas MRV Communications EM316E3SF
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones MRV Communications EM316E3SF.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje MRV Communications EM316E3SF, instrucciones de servicio, instrucciones cortas o instrucciones de usuario MRV Communications EM316E3SF. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto MRV Communications EM316E3SF.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo MRV Communications EM316E3SF, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar MRV Communications EM316E3SF. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de MRV Communications EM316E3SF.

El manual de instrucciones completo de MRV Communications debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual MRV Communications EM316E3SF - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice MRV Communications EM316E3SF, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de MRV Communications EM316E3SF que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo MRV Communications EM316E3SF - que deben facilitarnos los primeros pasos durante el uso de MRV Communications EM316E3SF
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con MRV Communications EM316E3SF
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de MRV Communications EM316E3SF en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de MRV Communications EM316E3SF?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con MRV Communications EM316E3SF, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con MRV Communications EM316E3SF probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)