    TECHNICAL GUIDE STELLAR PLUS TM SPLIT -SYSTEM AIR CONDITIONERS 12 SEER MODELS: H4DH018 THRU 060 (1.5 THRU 5 NOMINAL TONS) Due to contin uous product improv ement, specification s are subjec t to change without n otice. V isit us on the web at www .york.com for the m ost up-to-date te chnical informatio n. Additional r a ting i nformation can be f o ...

  • York H4DH018 THRU 060 - page 2

    036-2102 0-003 Rev. C (0203) 2 Unitary Produ cts Group All dimensions are in i nches. They are subject to change without notice. Certified dimensions will be pr ovided upon request. Physi cal and El ectrical D at a MODE L H4DH018S06 H 4DH024S06 H4DH030S06 H4DH036S06 H4DH042S 06 H4DH048S06 H4DH060S06 Unit Supply V oltage 208/230 – 1 – 60 Normal ...

  • York H4DH018 THRU 060 - page 3

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 3 Procedures: 1.Unit factor y charge liste d on the unit namep late includes refrigeran t for the c ondenser, the smallest e vaporator and for 1 5 f eet of interconnec ting line tubin g. 2.V er ify the orifice size and ad ditional char ge required f or specific eva porator coil in the system u si ...

  • York H4DH018 THRU 060 - page 4

    036-2102 0-003 Rev. C (0203) 4 Unitary Produ cts Group - = No t appl icabl e COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COI L 1 MODEL 1. G2FD co ils availabl e with a fa ctory ins talled horizo ntal drain pan. See pric e pages for specific m odel numbe r . COOLING MODEL ELEC TRIC 2 HEA T KW 2. Single phase units re quire sin ...

  • York H4DH018 THRU 060 - page 5

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 5 COOLING CAP ACI TY - Upf l ow , Downflow, & Horizont al Furnaces and Coils * UNIT MODEL FURNACE** COIL MODE L COO LING CFM RANGE (MIN.-M AX.) W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 1 EER TOTAL SE N S. H4DH018S06 575 725 14,17 G1F A024S14,17 650 18.2 13.7 12.20 - 10.60 14 G1F A030S 14 ...

  • York H4DH018 THRU 060 - page 6

    036-2102 0-003 Rev. C (0203) 6 Unitary Produ cts Group * Require s a 2FD B lower Time Delay u nless a standa rd furn ace is equip ped with one. ** Refer to Quick Select ion Chart for sp ecific furnace match-up . H4DH042S06 1225 1575 17 G1F A048S 17 1400 41.0 30.8 12.15 - 10.70 21,24 G1F A048S21 1400 41.5 31.1 12.30 - 10.80 21,24 G1F A060S21,24 1400 ...

  • York H4DH018 THRU 060 - page 7

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 7 COOLING CAP AC ITY - With V ar iable Speed Fu rnaces UN IT M ODEL V ARIABL E SPEED FURNACE MODE L COIL MODEL 1 W COO LING RA TED CFM NET MBH SEER W/O TXV SEER + TXV 2 EER TOTAL SE N S. 1 PH 12 SEER AC / P1DU / P1XD / P1XU - V ARIABLE SP EED 3 H4DH018S06 P1DUA12V G 1F A024S14 14 645 18.8 14.1 14 ...

  • York H4DH018 THRU 060 - page 8

    036-2102 0-003 Rev. C (0203) 8 Unitary Produ cts Group For No tes see Pa ge 8. H4DH036S06 P1DUB16V G 1F A036S17 17 1220 35.8 26.5 13.00 - 1 1.80 P1DUB16V G 1F A048S17 17 1220 38.0 28.1 13.50 - 12.40 P1DUB16V G1HD036 - 1220 35.8 26.5 13. 00 - 1 1.65 P1DUB16V G1HD048 - 1220 38.5 28.5 13. 50 - 1 1.85 P1DUB16V G1UA 036S17 17 1220 35.8 26.5 13.00 - 1 1. ...

  • York H4DH018 THRU 060 - page 9

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 9 H4DH048S06 P1DUB16V G 1F A048S17 17 1500 48.5 36.4 13.00 - 1 1.85 P1DUB16V G1UA 048S17 17 1500 48.5 36.4 13.00 - 1 1.85 P1DUC20V G1F A048S 21 21 1610 48.0 36.0 12. 45 - 1 1.20 P1DUC20V G1F A060S 21 21 1610 49.5 37.1 13. 30 - 1 1.60 P1DUC20V G1HD048 - 1610 49.0 36.8 12.25 - 1 1.35 P1DUC20V G1UA0 ...

  • York H4DH018 THRU 060 - page 10

    036-2102 0-003 Rev. C (0203) 10 Unitary Produ cts Group 1. For co ndensin g unit only. Does not include effect of evap orator mo tor pow er or he at. 2. Perfo rmance ba sed on 15 ° superhe at and 15° sub-cooli ng at con densing unit . a. Increas e capacity 1% f or each 2° increas e in sub-coo ling. b. Decrease capacity 1% fo r each 2° de crease ...

  • York H4DH018 THRU 060 - page 11

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 11 TYPICAL INST ALLA TIO N TYPICAL FIELD WIRING - 1 PHAS E APPLICATION L INST ALLA T ION THERMOST A T TO INDOOR BLOWER TO COI L NEC CLASS 2 WIRING NEC CLASS 1 WIRING TO POWER SUPPL Y WEA THERPROOF DISCONNECT SWITCH Seal open ing(s) wi th perma gum or equivale nt 24 ” SER VICE ACCESS CLEARANCE 4 ...

  • York H4DH018 THRU 060 - page 12

    036-2102 0-003 Rev. C (0203) 12 Unitary Produ cts Group Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH018S06 INDOOR COIL MODEL NO. G1F A024S14,17 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 600 650 700 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York H4DH018 THRU 060 - page 13

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 13 Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH024S06 INDOOR COIL MODEL NO. G1F A024S14,17 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 800 850 900 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York H4DH018 THRU 060 - page 14

    036-2102 0-003 Rev. C (0203) 14 Unitary Produ cts Group Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH030S06 INDOOR COIL MODEL NO. G1F A036S17,21 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 980 1030 1080 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 ...

  • York H4DH018 THRU 060 - page 15

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 15 Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH036S06 INDOOR COIL MODEL NO. G1F A036S17,21 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1 100 1200 1300 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 ...

  • York H4DH018 THRU 060 - page 16

    036-2102 0-003 Rev. C (0203) 16 Unitary Produ cts Group Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH042S06 INDOOR COIL MODEL NO. G1F A048S17 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1300 1400 1500 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York H4DH018 THRU 060 - page 17

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 17 Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH048S06 INDOOR COIL MODEL NO. G1F A048S21 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1450 1600 1750 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York H4DH018 THRU 060 - page 18

    036-2102 0-003 Rev. C (0203) 18 Unitary Produ cts Group Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH060S06 INDOOR COIL MODEL NO. G1F A060S21,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1600 1800 2000 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 7 ...

  • York H4DH018 THRU 060 - page 19

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 19 MA TCHIN G INDOOR COMPONENTS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory inst alled horizontal drain pan. ADD-ON COILS - FOR FURNACE APPLICA TIONS G1NA UNCASED UPFLOW G1F A FULL CASED UPFLOW AIR HANDLERS - FOR N ...

  • York H4DH018 THRU 060 - page 20

    Subject to change without notice. Printed in U.S.A. 036-21020-003 Rev. C ( 0203) Copyright © by York International Corp. 2003. All rights reserved. Supersedes: 036-21020-003 Rev. B (0702) Unit ary 5005 Norma n Product Y ork OK Group Drive 7306 9 NOTES ...

Fabricante York Categoría Air Conditioner

Los documentos del dispositivo York H4DH018 THRU 060 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones H4DH018 THRU 060
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York H4DH018 THRU 060
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York H4DH018 THRU 060.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York H4DH018 THRU 060, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York H4DH018 THRU 060. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York H4DH018 THRU 060.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York H4DH018 THRU 060, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York H4DH018 THRU 060. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York H4DH018 THRU 060.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York H4DH018 THRU 060 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York H4DH018 THRU 060, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York H4DH018 THRU 060 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York H4DH018 THRU 060 - que deben facilitarnos los primeros pasos durante el uso de York H4DH018 THRU 060
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York H4DH018 THRU 060
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York H4DH018 THRU 060 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York H4DH018 THRU 060?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York H4DH018 THRU 060, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York H4DH018 THRU 060 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)