  • GE NX-124E - page 1

    NetworX ™ NX-6 User Manual ...

  • GE NX-124E - page 2

    NX- 6 SYSTEM KEYPAD Includes models NX-108E, NX-116E, NX- 1 24 E POWER Light is “on” when AC power is present; flashes to indicate a low battery condition. READY Light is “on” when the system is ready to arm; flashes if ready to “force arm”. SERVICE Light is “on” to indicate a trouble condition with your system. ARMED Light is “on ...

  • GE NX-124E - page 3

    1 SECURITY SYSTEM NOTES Installing/Service Company ___________________________ ______ For Service Call __________________________________________ Central Station _____________________________________ ______ Duress Code ___________________ _ FUNCTION CODES Function Code Controls Function This system is  is not  partitioned. EMERGENCY ACTIVATIO ...

  • GE NX-124E - page 4

    2 THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM AND BECOME PROFICIENT IN ITS OPERATION. A LL USERS OF YOUR SECURITY SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN THIS BOOKLET. FAILURE TO DO SO COU LD RESULT IN THE SECURITY SYSTEM NOT WORKI NG PROPERLY. THIS BOOKLET SHOULD BE KEPT IN AN ACCESSIBL E LOCA TIO ...

  • GE NX-124E - page 5

    3 TABLE OF CONTENTS GLOSSARY OF TERMS ..........................................................................4 UNDERSTANDING THE LIGHTS ............................................................5 Armed Light ........................................................................................5 Bypass Light .................................. ...

  • GE NX-124E - page 6

    4 GLOSSARY OF TERMS Abort Delay : An option that allows a delay in reporting to the central s tation. There is a communicator delay of 30 seconds . It can be removed, or increased up to 45 seconds at the opti on of the end user by c onsulting with the i nstaller. Authority Level : The level of access an individual has when us ing an alarm panel. Ce ...

  • GE NX-124E - page 7

    5 UNDERSTANDING THE LIGHTS Armed Light The armed light is “on” when the system is armed. The armed li ght is “off” when it is disarmed. The armed lig ht will flash when there has been an alarm during the previous arm c ycle. Bypass Light The bypass light is “on” when any z one in this keypa d’s partition is bypas sed. The zone(s) that ...

  • GE NX-124E - page 8

    6 Ready Light The ready light is “on” when the system is ready to arm and “fl ashes” if ready to force arm. The ready light is off when the system is not ready to ar m because of a zone(s) being fault ed. Stay Light The stay light is “on” when the all i nterior (motion detector) zones are bypassed. Zone Light The zone lights are “off? ...

  • GE NX-124E - page 9

    7 KEYPAD FUNCTIONS ARMING YOUR SYSTEM IN THE “AWAY” MODE AWAY is used when the user is away from the premi se and wants the interior protected. Listed belo w are the steps to arm in the AWAY Mode: Step 1 Clos e all protected doors and windows. • Ready light will be on or flashing when all protected z ones and sensors are secure. NOTE: If any ...

  • GE NX-124E - page 10

    8 Step 3 • Press the [ STAY ] key. • The stay light will illuminate ind icating that all interi or zones are bypassed. (All interior devices will bypass automatically, giving the user freedom of movement with in the interior area.) • The bypass light will illuminate if any zone(s) are bypass ed. If any zone(s) have been bypas sed previously b ...

  • GE NX-124E - page 11

    9 CANCEL / ABORT FEATURE (Optional, see page 1) The c ancel light will flash during a n abort delay time. If a code is entered followed by the [ CANCEL ] key while this light is flashing, all aborta ble reports will stop the communication pr ocess. Entering a code followed b y the [ CANCEL ] key during or after an alarm report to th e central stati ...

  • GE NX-124E - page 12

    10 CHANGING USER CODES Step 1 Your system mus t be in the Disarmed state to chang e user codes. Step 2 Press [ r ]-[ 5 ]. Step 3 Enter a “Mast er Arm/Disarm Code”. NOTE: For partitioned systems, someone changing the code of another person must have access to all or more partitions than the user being changed. Step 4 The ready li ght will flash. ...

  • GE NX-124E - page 13

    11 LIGHT AUTHORITY LEVELS IF LIGHT 8 IS OFF 1 Reserved ( Note: Do not change if on.) 2 Arm Only 3 Arm Only After Closing Time 4 Master Arm/Disarm (can program other codes) 5 Arm/Disarm 6 Bypass Zones 7 Open / Close Reporting 8 If this light is on, this code is programmed as a function code. Do not change! Press [#] - [#] to exit. Step 6 Press the [ ...

  • GE NX-124E - page 14

    12 OTHER KEYPAD FUNCTIONS SETTING THE KEYPAD TONE Step 1 Press [ r ]-[ 0 ]. Keypad is now in the “Adju st Tone” mode. Step 2 Press ing the [ 1 ] key will make the keypad sounder go to higher tones, pressing the [ 2 ] key will make the k eypad sounder go to lo wer tones. Step 3 When the desired tone is reached, press the [ # ] key to s et this t ...

  • GE NX-124E - page 15

    13 Step 2 Each time a zone is fault ed, the zone light on the LED keypad will illuminate and the chim e will sound. The num ber of the faulted zone(s) will be dis played on the LCD keypad. It will al so be entered into alarm memory and th e internal log. Step 3 The k eypad will begin to beep after 15 minutes in this mode. This beeping indicates tha ...

  • GE NX-124E - page 16

    14 Step 2 Enter the “Ma ster Code “. Step 3 Enter the “hou r code” which must be two (2) digits. Not e: The clock is a 24-hour clock. Refer to the following table on page 14. Step 4 Enter the “mi nutes code” which must be t wo (2) digits. Example: 7 minutes aft er would be entered [ 0 ]–[ 7 ]. Time Hour Code Time Hour Code Time Hour C ...

  • GE NX-124E - page 17

    15 SERVICE MENU The service light will be “on” if the sec urity sys tem requires servic e. If the service light is “on”, press the [ r ] key follo wed by the [ 2 ] key to determine the s ervice condition. One or more zone l ights will illuminate in dicating what s ervice(s) is required. Call your service provid er immediately for these prob ...

  • GE NX-124E - page 18

    16 EMERGENCY EVACUATION PLANS An emergency evacuation plan should be es tablished for an actual fire alarm condition. For e xample, the following steps are recommended by the National Fire Protection Association and c an be used as a guide in esta blishing an evacuation plan for y our building. Draw up a floor plan of your home. Show windows, doors ...

  • GE NX-124E - page 19

    17 SYSTEM NOTES ...

  • GE NX-124E - page 20

    NX-6 USER’S MANUAL NX6UD04 REV D (FEB 2004) ...

Fabricante GE Categoría Home Security System

Los documentos del dispositivo GE NX-124E que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos GE
- manuales de instrucciones NX-124E
- hojas de producto GE
- folletos informativos
- o etiquetas energéticas GE NX-124E
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones GE NX-124E.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje GE NX-124E, instrucciones de servicio, instrucciones cortas o instrucciones de usuario GE NX-124E. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto GE NX-124E.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo GE NX-124E, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar GE NX-124E. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de GE NX-124E.

El manual de instrucciones completo de GE debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual GE NX-124E - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice GE NX-124E, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de GE NX-124E que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo GE NX-124E - que deben facilitarnos los primeros pasos durante el uso de GE NX-124E
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con GE NX-124E
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de GE NX-124E en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de GE NX-124E?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con GE NX-124E, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con GE NX-124E probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)