    Installa tion & Oper a tion Manual Models: SSS031, SSS041, SSS051, SSS081, & SSS119 T h i s ma n ua l m u s t o n ly b e us e d b y a qualified heating installer / serv ice technician. Read all instructions before installing. P erfor m steps in the order given. Failure to c omply could result in sev ere personal injur y , death, or substant ...

  • Lochinvar SSS041 - page 2

    Installation & Operation Manual 2 Hazar d definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Please r ead before pr oceeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. General Infor mation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lochinvar SSS041 - page 3

    Installation & Operation Manual Please r ead bef ore pr oceeding Installer – R ead all instructions before installing. P erform steps in the order give n. Ha ve this indir ect water heat er serv iced/inspected by a qualified service technician, at least annually . Failure t o comply with the abov e could result in severe personal injury , dea ...

  • Lochinvar SSS041 - page 4

    Installation & Operation Manual 4 1 Gener al Infor mation The Lochin var SSS series indirect water heat er (FIG. 1-1) is designed to generate domestic hot water in conjunction with a hot water boiler using forc ed boiler water cir culation. This indirect water heat er consists of a 444 Stainless Steel tank in which a smooth 304 stainless steel ...

  • Lochinvar SSS041 - page 5

    Installation & Operation Manual 5 Failure t o properly support the tank could result in property damage or personal injur y .  W ARNING 2 Pre-installation 1. The installation must conform with the instructions in this manual and all applicable local, state, provincial, and national codes, la ws, regulations, and ordinances. Installations in ...

  • Lochinvar SSS041 - page 6

    Installation & Operation Manual 6 Boiler Side Piping Figures 3-1 thru 3-3 show typical boiler side piping for several common situations. Regardless of which system is used it is imperative that the flo w rates called for in T able 3A on page 6 are developed thr ough the coil. This requir es properly sized piping and a pr operly sized pump . The ...

  • Lochinvar SSS041 - page 7

    Installation & Operation Manual 7 SOLUTION BOILER SQUIRE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR ZONE #1 ZONE #2 ZONE #3 ZONE #4 BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE DRAIN POINT (TYPICAL) MAK E U P W A TER HOT WA TE R OUT BOILER CIRCULATOR BACKFLOW PREVENTER PRESSURE REDUCING VALVE ...

  • Lochinvar SSS041 - page 8

    Installation & Operation Manual 8 3 Piping SOLUTION BOILER SQUIRE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR ZONE #1 ZONE #2 ZONE #3 ZONE #4 BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE DRAIN POINT (TYPICAL) MAK E U P W AT ER HOT WA TE R OUT BOILER CIRCULATOR BACKFLOW PREVENTER PRESSURE REDUC ...

  • Lochinvar SSS041 - page 9

    Installation & Operation Manual 9 3 Piping (continued) Figure 3-4 Multiple T ank Connections BOILER DOMESTIC HOT W ATER CIRCULATO R BACKFLOW PREVENTER PRESSURE REDUCING VALVE PRESSURE GAUGE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR EXPANSION TANK BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE ...

  • Lochinvar SSS041 - page 10

    Installation & Operation Manual 10 3 Piping Domestic Side Piping Basic Domestic Piping Figure 3-5 on page 12 sho ws ty pical domestic water piping for a tank. All c omponents ex cept the control are pr ovided by the installer . The function of the components shown are as follows: a. Shut-off valves (recommended) - U se to isolate the tank for s ...

  • Lochinvar SSS041 - page 11

    Installation & Operation Manual 11 3 Piping (continued) W hen no fixtures are dra wing water , the br onze cir culator mov es hot water from the tank t o the end of the branch just below the last fixtur e, then back to the inlet of the tank v ia the return pipe. W hen a fixture is opened, hot water is alr eady out in the branch very close to th ...

  • Lochinvar SSS041 - page 12

    Installation & Operation Manual 12 3 Piping Figure 3-5 Recommended Domestic Water Piping ...

  • Lochinvar SSS041 - page 13

    Installation & Operation Manual 13 4 W iring Indirect Water Hea ter Sensor Setup (Knight Boiler) Label all wires prior to disconnection when serv icing controls. W ir ing errors can cause improper and dangerous operation.  CAUTION 1. Install the sensor inside the tank as depicted in FIG. 4-1. 2. Connect the wire leads to the DHW T ank Sensor ...

  • Lochinvar SSS041 - page 14

    Installation & Operation Manual 14 4 W iring IDW Contr olled Using Aquastat and Zone Circulator / V alv e 1. Install A quastat to tank. A quastat contr ol (TST1085) can be ordered from y our local Lochin var dist ributor . 2. Connect A quastat to the zone c ontroller for the I ndirect W ater Heat er Zone. 3. Adjust Aquastat to the desir ed temp ...

  • Lochinvar SSS041 - page 15

    Installation & Operation Manual 15 5 Star t-up and Check-out 1. Make sure the syst em is free of leaks and that air is purged from the system. CAUTION Fix any leaks found befor e proc eeding further . Leakage from the boiler piping can result in sever e damage to the boiler . 2. Many soldering flux es contain Zinc Chloride which can cause sever ...

  • Lochinvar SSS041 - page 16

    LIM IT ED LIFETIME INDIRECT W A TER HEA TER W ARRANTY WHA T DOES THIS LIMITED W ARRANTY COVER? This limited lifetime warranty covers the stainless steel tank, stainless steel heat exchanger coil and component parts for leakage or other malfunction caused by defects in materials and/or workmanship. It extends to the first buyer and to any subsequent ...

  • Lochinvar SSS041 - page 17

    LIM ITE D LIFETIME INDIRECT W A TER HEA TER W ARRANTY (CONTINUED) ©–12/06—Printed in U.S.A. WHA T WILL WE DO T O CORRECT PROBLEM? If a defect occurs within the warranty period, we will: 1. Provide a comparable replacement water heater of our manufacture, (or at our option repair) any unit which develops a leak in the stainless steel tank or he ...

  • Lochinvar SSS041 - page 18

    18 Notes ...

  • Lochinvar SSS041 - page 19

    19 Notes ...

  • Lochinvar SSS041 - page 20

    Revision Notes: Revision B (SSS-I&O-Rev B) reflects edits and additions made to the piping diagrams. Revision C (SSS-I&O-Rev C) reflects edits made to the piping diagrams, the DHW T ank Sensor (AUX) and the addition of the warranty . Revision D (ECO #C02870) reflects the addition of the scald chart on page 3. SSS-I&O Rev D 1/09 - Printe ...

Fabricante Lochinvar Categoría Water Heater

Los documentos del dispositivo Lochinvar SSS041 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lochinvar
- manuales de instrucciones SSS041
- hojas de producto Lochinvar
- folletos informativos
- o etiquetas energéticas Lochinvar SSS041
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lochinvar SSS041.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lochinvar SSS041, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lochinvar SSS041. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lochinvar SSS041.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Lochinvar SSS041, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lochinvar SSS041. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lochinvar SSS041.

El manual de instrucciones completo de Lochinvar debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lochinvar SSS041 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lochinvar SSS041, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lochinvar SSS041 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lochinvar SSS041 - que deben facilitarnos los primeros pasos durante el uso de Lochinvar SSS041
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lochinvar SSS041
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lochinvar SSS041 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lochinvar SSS041?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lochinvar SSS041, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lochinvar SSS041 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)