Manual de instrucciones Hoshizaki KM-630MRH

67 de páginas 1.21 mb
Descargar

Pasar a la página of 67

Summary
  • Hoshizaki KM-630MRH - page 1

    73114 HOSHIZAKI MODULAR CRESCENT CUBER SER VICE MANU AL KM-630MAH KM-630MWH KM-630MRH MODEL JUNE 23, 2004 NO.: ISSUED: ...

  • Hoshizaki KM-630MRH - page 2

    2 IMPORT ANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual. HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City , GA 30269 Attn: HOSHIZAKI T echnical Support Department Phone: 1-800-233-1940 T ...

  • Hoshizaki KM-630MRH - page 3

    3 CONTENTS I. SPECIFICA TIONS ............................................................................................................ 5 1. KM-630MAH ................................................................................................................ 5 2a. KM-630MWH Serial #L00001D - M20270B ......................................... ...

  • Hoshizaki KM-630MRH - page 4

    4 IV . SER VICE DIA GNOSIS ................................................................................................. 41 1. NO ICE PRODUCTION .............................................................................................. 4 1 2. EV APORA T OR IS FROZEN UP ........................................................................ ...

  • Hoshizaki KM-630MRH - page 5

    5 I. SPECIFICA TIONS 1. KM-630MAH Note: We reserve the right to make changes in specifications and design without prior notice. A C S UP P LY V O LT A GE 208-230 / 60/ 1 (3 wire w i t h neut ral for 115V ) A M P E RA GE 7. 5 A ( 5 M i n. F reez e A T 104°F / W T 80°F) M INIM UM CIRCUIT A M P A CI T Y 15 A MAX I MU M FU SE SI Z E 1 5 A APPR O X I ...

  • Hoshizaki KM-630MRH - page 6

    6 2a. KM-630MWH Serial #L00001D - M20270B Note: We reserve the right to make changes in specifications and design without prior notice. AC SU PPL Y V O LT AG E AMPER AG E M INIM UM CIRCUIT A M P A CIT Y MAX I MU M FU SE SI Z E APPR O X I MAT E I C E PRO D U C T I O N Ambi e nt W AT ER T EMP. ( ° F) P E R 24 HR . T emp. (°F) 50 70 l bs . / day ( k ...

  • Hoshizaki KM-630MRH - page 7

    7 2b. KM-630MWH Serial #M20301E - A C S UP P LY V O LT A GE 208-230 / 60/ 1 (3 wire w i t h neut ral f or 115V ) A M P E RA GE 6. 5 A ( 5 M i n. F reez e A T 104°F / W T 80°F) M INIM UM CIRCUIT A M P A CI T Y 15 A MAX I MU M FU SE SI Z E 1 5 A APPR O X I MAT E I C E PR OD U CT I ON Amb ie n t W AT ER T EMP. ( ° F) PER 2 4 H R . T e mp .( ° F) 5 ...

  • Hoshizaki KM-630MRH - page 8

    8 3. KM-630MRH Note: We reserve the right to make changes in specifications and design without prior notice. A C S UP P LY V O LT A GE 208-230 / 60/ 1 (3 wire w i t h neut ral f or 115V ) A M P E RA GE 6. 5 A ( 5 M i n. F reez e A T 104°F / W T 80°F) M INIM UM CIRCUIT A M P A CI T Y 15 A MAX I MU M FU SE SI Z E 1 5 A APPR O X I MAT E I C E PR OD ...

  • Hoshizaki KM-630MRH - page 9

    9 4. CONDENSER UNIT URC-6F 24" (610 mm.) 23-1/32" (585 mm.) 19-11/16" (500 mm.) 18-1/8" (460 mm.) 20-15/32" (520 mm.) 21-15/16" (557 mm.) 7/8" DIA. HOLE (23 mm. DIA.) 6-5/16" (160 mm.) 2-15/16" (75 mm.) 18-1/8" (460 mm.) 6/16" x 3/4" (10 mm. x 20 mm.) 4 x 2 (SLOTTED HOLES) 17-1/8" (43 ...

  • Hoshizaki KM-630MRH - page 10

    10 Galvanized Steel 21-15/16" x 15-11/16" x 17-7/8" (557 x 398 x 453.8 mm.) R40 4A 1 lb. 2 oz. (505 g) Net 61 lbs. (28 kg) Shipping 68 lbs. (31 kg) One Shot Couplings (Aeroquip) Permanent Connection Air-cooled Condensing Pressure Regulator Min. -20°F - Max. +122°F (-29°C to +50°C) Outdoor use SPECIFICATIONS EXTERIOR DIMENSIONS (W ...

  • Hoshizaki KM-630MRH - page 11

    11 II. GENERAL INFORMA TION 1. CONSTRUCTION [a] KM-630MAH Spray Tubes Water Supply Inlet Control Switch Condenser Hot Gas Valve Expansion Valve Fan Motor Condenser Compressor Drier Float Switch Control Box Water Pump Bin Control Thermostat (except models with Mechanical Bin Control) Mechanical Bin Control (except models with Thermostat) ...

  • Hoshizaki KM-630MRH - page 12

    12 [b] KM-630MWH Spray Tubes Water Supply Inlet Control Switch Water Regulator Expansion Valve Hot Gas Valve Compressor Float Switch Drier Water Pump Control Box Bin Control Thermostat (except models with Mechanical Bin Control) Mechanical Bin Control (except models with Thermostat) ...

  • Hoshizaki KM-630MRH - page 13

    13 [c] KM-630MRH Spray Tubes Water Supply Inlet Control Switch Junction Box Expansion Valve Receiver Tank Compressor Float Switch Drier Water Pump Hot Gas Valve Line Valve Control Box Bin Control Thermostat (except models with Mechanical Bin Control) Mechanical Bin Control (except models with Thermostat) ...

  • Hoshizaki KM-630MRH - page 14

    14 2. CONTROLLER BOARD [a] SOLID-STATE CONTROL 1) A HOSHIZAKI exclusive solid-state control is employed in Modular Crescent Cubers. 2) A Printed Circuit Board (hereafter called “Controller Board”) includes a stable and high quality control system. 3) All models are pretested and factory-adjusted. [b] CONTROLLER BOARD CAUTION 1. Fragile, handle ...

  • Hoshizaki KM-630MRH - page 15

    15 2) Defrost Timer The defrost cycle starts when the Float Switch opens and completes the freeze cycle. But the Defrost Timer does not start counting until the Thermistor senses 48°F at the Evaporator outlet. The period from the end of the freeze cycle up to the point of the Thermistor's sensing varies depending on the ambient and water temp ...

  • Hoshizaki KM-630MRH - page 16

    16 The green LED’s 1-4 represent the corresponding relays and energize and sequence 5 seconds from initial start-up as follows: Sequence Step LED’s on Length: Min. Max. Avg. 1 Minute Fill Cycle LED4 60 sec. Harvest Cycle LED1, 4, & 2 2 min. 20 min. 3-5 min. Freeze Cycle LED1 5 min. 60 min. 30-35 min. Reverse Pump Out LED1, 3, & 2 10 sec ...

  • Hoshizaki KM-630MRH - page 17

    17 (Control Products HOS-001A Board) The application switch located between relay X3 & X4 must be set to match the original board application. Place this switch in the ALP position if there is no white wire supplied to the K1 connector. If there is a white wire, place the switch in the C position. If this switch is placed in the wrong position, ...

  • Hoshizaki KM-630MRH - page 18

    18 [c] SEQUENCE 1st Cycle 1. Unit energized and Control Switch to “ICE” position. Water supply cycle starts. 2. After 1 minute, Defrost cycle starts. 3. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Valve opening is limited to 6 minutes. & 5. After the first 5 minutes in freeze cycle. Ready to complete freeze cycle ...

  • Hoshizaki KM-630MRH - page 19

    19 2nd Cycle and after with pump drain IMPORTANT Freeze cycle time is limited to 60 minutes even if Float Switch does not open. 1. Float Switch opens and signals to complete freeze cycle. Drain timer starts counting. 2. Drain timer stops counting. Pump drain is completed 3. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Val ...

  • Hoshizaki KM-630MRH - page 20

    20 IMPORTANT Freeze cycle time is limited to 60 minutes even if Float Switch does not open. 2nd Cycle and after with no pump drain 1. Float Switch opens and signals to complete freeze cycle. 2. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Valve opening is limited to 6 minutes. 4. After the first 5 minutes in freeze cycle. ...

  • Hoshizaki KM-630MRH - page 21

    21 [d] CONTROLS AND ADJUSTMENTS The Dip Switch is factory-adjusted to the following positions: FOR MODELS WITH MECHANICAL BIN CONTROL: Switch Nos. 1 and 2: Used for adjustment of the Defrost Timer. The Defrost Timer starts counting when the Thermistor reads a certain temperature at the Evaporator outlet. Switch Nos. 3 and 4: Used for adjustment of ...

  • Hoshizaki KM-630MRH - page 22

    22 1) Defrost Control A thermistor (Semiconductor) is used for a defrost control sensor. The resistance varies depending on the Suction Line temperatures. The Thermistor detects the temperature of the Evaporator outlet to start the Defrost Timer. No adjustment is required. If necessary, check for resistance between Thermistor leads, and visually ch ...

  • Hoshizaki KM-630MRH - page 23

    23 3) Drain Timer The Drain Timer is factory-adjusted, and no adjustment is required. SETTING TIME Dip Switch Dip Switch No. 3 No. 4 T 1 T 2 OFF OFF 10 seconds 150 seconds O N OFF 10 seconds 180 seconds OFF O N 10 seconds 120 seconds O N O N 20 seconds 180 seconds T1: Time to drain the Water Tank T2: Time to restrain defrost completion 4) Drain Cou ...

  • Hoshizaki KM-630MRH - page 24

    24 6) Bin Control MODELS WITH THERMOSTAT CAUTION When the ambient temperature is below 45°F, the Bin Control Thermostat operates to stop the icemaker even if the Ice Storage Bin is empty. When the Thermostat is set in the prohibited range, the icemaker operates con- tinuously even if the Ice Storage Bin is filled with ice. Setting in the prohib- i ...

  • Hoshizaki KM-630MRH - page 25

    25 (iv) After Step (iii), de-energize the unit and confirm that the Defrost Timer is in the minimum position. Disconnect the resistor from the Controller Board, and energize the unit. After the 1 minute water supply cycle, the defrost cycle starts. Reconnect a 1.5 k Ω - 3.5 k Ω resistor to the Connector K3 (pins #1 and #2) after the first 2 min ...

  • Hoshizaki KM-630MRH - page 26

    26 3. MECHANICAL BIN CONTROL (THESE INSTRUCTIONS NOT APPLICABLE TO MODELS WITH THERMOSTAT) [a] PROXIMITY SWITCH 1) This machine uses a lever-actuated proximity switch (hereafter called “mechanical bin con- trol”) to control the ice level in the storage bin. [b] EXPLANATION OF OPERATION 1) The startup and shutdown of the ice machine is controlle ...

  • Hoshizaki KM-630MRH - page 27

    27 [c] TROUBLESHOOTING (MECHANICAL BIN CONTROL ONLY) 1) Machine will not start (i) Move dip switch No. 7 to the “OFF” position. If the machine starts up within a few seconds, the bin control is the likely problem. If the machine does not start up, refer to Section “IV. Service Diagnosis” to verify that non-bin control related issues are res ...

  • Hoshizaki KM-630MRH - page 28

    28 III. TECHNICAL INFORMA TION 1. W A TER CIRCUIT AND REFRIGERANT CIRCUIT [a] KM-630MAH ...

  • Hoshizaki KM-630MRH - page 29

    29 [b] KM-630MWH ...

  • Hoshizaki KM-630MRH - page 30

    30 [c] KM-630MRH ...

  • Hoshizaki KM-630MRH - page 31

    31 2. WIRING DIAGRAMS [a1] KM-630MAH (with auxiliary codes L-0, M-0, and M-1) and KM-630MWH (with auxiliary codes L-0, M-0, M-1, and M-2) Note: Pressure Switch MAH MWH Cut-out 4 1 2 PSIG Cut-in 327 ± 21 PSIG + 21 - 0 Cut-out 3 8 4 PSIG Cut-in 284 ± 21 PSIG + 21 - 0 ...

  • Hoshizaki KM-630MRH - page 32

    32 [a2] KM-630MAH (with auxiliary codes M-2 and after) and KM-630MWH (with auxiliary codes M-3 and after) ...

  • Hoshizaki KM-630MRH - page 33

    33 U1GMA0179608 Note: Pressure Switch Cut-out 4 1 2 PSIG Cut-in 327 ± 21 PSIG [b1] KM-630MRH (with auxiliary codes L-0, M-0, M-1) + 21 - 0 ...

  • Hoshizaki KM-630MRH - page 34

    34 [b2] KM-630MRH (with auxiliary codes M-2 and after) ...

  • Hoshizaki KM-630MRH - page 35

    35 3. TIMING CHART ...

  • Hoshizaki KM-630MRH - page 36

    36 ...

  • Hoshizaki KM-630MRH - page 37

    37 4. PERFORMANCE D A T A [a] KM-630MAH Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. We reserve the right to make changes in specifications and design without prior notice. 70/ 21 600 272 562 255 514 233 80/ 27 571 259 512 232 466 2 11 90/ 32 562 25 5 470 213 42 2 191 lb s./ ...

  • Hoshizaki KM-630MRH - page 38

    38 [b1] KM-630MWH Serial #L00001D - M20270B 70/ 21 *619 281 596 2 70 563 256 80/ 27 602 273 566 2 57 533 242 90/ 32 596 270 *5 41 245 507 230 lb s./da y k g ./d a y 100/ 38 589 267 533 2 42 *476 216 70/ 21 80/ 27 90/ 32 w a tts 1 0 0 /3 8 70/ 21 *793 3. 00 865 3. 28 1080 4. 09 80/ 27 848 3. 21 1024 3. 88 1240 4. 69 90/ 32 1150 4. 35 *1040 3. 94 129 ...

  • Hoshizaki KM-630MRH - page 39

    39 [b2] KM-630MWH Serial #M20301E - Note: Pressure data is recorded at 5 minutes into freeze cycle. The data without * should be used for reference only. We reserve the right to make changes in specifications and design without prior notice. 70/ 21 *621 282 603 273 563 256 80/ 27 607 275 578 262 532 2 41 90/ 32 603 273 *558 253 51 4 233 lb s./da y ...

  • Hoshizaki KM-630MRH - page 40

    40 [c] KM-630MRH Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. We reserve the right to make changes in specifications and design without prior notice. 70/ 21 603 274 573 260 531 241 80/ 27 580 263 532 242 491 2 23 90/ 32 573 26 0 499 226 45 7 207 lb s./da y k g ./d a y 100/ 3 ...

  • Hoshizaki KM-630MRH - page 41

    41 PROBLEM POSSIBLE CAUSE REMEDY [1] The icemaker a) Power Supply 1. “OFF” position. 1. Move to “ON” position will not start 2. Loose connections. 2. Tighten 3. Bad contacts. 3. Check for continuity and replace. 4. Voltage too high. 4. Check and get recommended voltage. b) Fuse (Inside Fused 1. Blown out. 1. Check for short circuit Disconne ...

  • Hoshizaki KM-630MRH - page 42

    42 PROBLEM POSSIBLE CAUSE REMEDY l) Controller Board 1. Defective 1. See “II.2[e] CHECKING CONTROLLER BOARD.” m) Interlock Switch 1. “CLOSED” position. 1. Move to “OPEN” position. (Cleaning Valve) 2. Bad contacts. 2. Check for continuity and replace. [2] Water a) Float switch 1. Connector disconnected. 1. Place in position. continues to ...

  • Hoshizaki KM-630MRH - page 43

    43 PROBLEM POSSIBLE CAUSE REMEDY [5] No water a) Water Supply Line 1. Water pressure too low and 1. Check and get comes from water level in Water Tank recommended pressure. Spray Tubes. too low. Water Pump b) Water Solenoid 1. Dirty mesh filter or orifice 1. Clean. will not start, or Valve and water level in Water freeze cycle Tank too low. time is ...

  • Hoshizaki KM-630MRH - page 44

    44 PROBLEM POSSIBLE CAUSE REMEDY [1] Freeze cycle a) Float Switch 1. Leads short-circuit or 1. Check and replace. time is too defective switch. long. 2. Float does not move freely. 2. Clean or replace. b) Water Solenoid 1. Diaphragm does not close. 1. Check for water leaks Valve with icemaker off. c) Controller Board 1. Defective. 1. See “II.2[e] ...

  • Hoshizaki KM-630MRH - page 45

    45 PROBLEM POSSIBLE CAUSE REMEDY [1] Icemaker will a) Bin Control 1. Set too cold. 1. Adjust warmer. not stop when Thermostat 2. Defective. 2. Replace. bin is filled with ice. For mechanical bin control see “II. 3. [c]” [2] Abnormal a) Pump Motor 1. Bearings worn out. 1. Replace. noise b) Fan Motor 1. Bearings worn out. 1. Replace. 2. Fan blade ...

  • Hoshizaki KM-630MRH - page 46

    46 V . REMO V AL AND REPLACEMENT OF COMPONENTS IMPORT ANT Ensure all components, fasteners and thumbscrews are securely in place after the equipment is serviced. IMPORT ANT 1. The Polyol Ester (POE) oils used in R-404A units can absorb moisture quickly. Therefore it is important to prevent moisture from entering the system when replacing or servici ...

  • Hoshizaki KM-630MRH - page 47

    47 4) Close the Low-side Valve and High-side Valve on the Service Manifold. 5) Disconnect the Vacuum Pump, and attach a Refrigerant Service Cylinder to the High-side line. Remember to loosen the connection, and purge the air from the Hose. See the Nameplate for the required refrigerant charge. Hoshizaki recommends only virgin refriger- ant or recla ...

  • Hoshizaki KM-630MRH - page 48

    48 3. REMO V AL AND REPLA CEMENT OF COMPRESSOR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. Note: When replacing a Compressor with a defective winding, be sure to install the new Start Capacitor and Start Relay supplied ...

  • Hoshizaki KM-630MRH - page 49

    49 15) Evacuate the system, and charge it with refrigerant. For air-cooled and water-cooled models, see the Nameplate for the required refrigerant charge. For remote air-cooled models, see the Charge Label in the machine compartment. 16) Connect the Terminals, and replace the Terminal Cover in its correct position. 17) Replace the panels in their c ...

  • Hoshizaki KM-630MRH - page 50

    50 4. REMO V AL AND REPLA CEMENT OF DRIER IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels. 3) Recover the refrigerant and store it in an approved container. 4) Remove the ...

  • Hoshizaki KM-630MRH - page 51

    51 3) Recover the refrigerant and store it in an approved container. 4) Remove the insulation and the Expansion Valve Bulb on the suction line. 5) Remove the Expansion Valve Cover, and disconnect the Expansion Valve using brazing equipment. 6) Braze the new Expansion Valve, with nitrogen gas flowing at the pressure of 3 - 4 PSIG. W ARNING Always pr ...

  • Hoshizaki KM-630MRH - page 52

    52 IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels. 3) Recover the refrigerant and store it in an approved container. 4) Remove the screw and the Solenoid. 5) Disconnect t ...

  • Hoshizaki KM-630MRH - page 53

    53 7. REMO V AL AND REPLA CEMENT OF EV APORA T OR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 1) Turn off the power supply. 2) Remove the panels and the Top Insulation over the Evaporator. 3) Recover the refrigerant ...

  • Hoshizaki KM-630MRH - page 54

    54 8. REMO V AL AND REPLA CEMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Close the Water Supply Line Shut-off Valve. 3) R ...

  • Hoshizaki KM-630MRH - page 55

    55 9. ADJUSTMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y The Water Regulating Valve (also called “WATER REGULATOR”) is factory-adjusted. No adjustment is required under normal use. Adjust the Water Regulator, if necessary, using the following procedures. 1) Attach a pressure gauge to the high-side line of the system. Or prep ...

  • Hoshizaki KM-630MRH - page 56

    56 10. REMO V AL AND REPLA CEMENT OF CONDENSING PRESSURE REGULA T OR (C.P .R.) - REMO TE AIR-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels from the re ...

  • Hoshizaki KM-630MRH - page 57

    57 11. REMO V AL AND REPLA CEMENT OF THERMIST OR CA UTION 1. Fragile, handle very carefully. 2. Always use a recommended sealant (High Thermal Conductive Type), Model KE4560RTV manufactured by SHINETSU SILICONE, Part Code 60Y000-11, or Part Code 4A0683-01 or equivalent. 3. Always use a recommended foam insulation (Non-absorbent Type) or equivalent. ...

  • Hoshizaki KM-630MRH - page 58

    58 Note: For models with the Liquid Bypass, the Thermistor should be located upstream from the Liquid Bypass outlet, and its end should be 4-3/4" or more away from the outlet. See Fig. 3. Min. 4-3/4" Liquid Bypass Flow 10) Secure the insulation using the Plastic Cable Ties. 11) Connect the Thermistor leads through the bushing of the Contr ...

  • Hoshizaki KM-630MRH - page 59

    59 6) Install the new Fan Motor, and replace the removed parts in the reverse order of which they were removed. 7) Replace the panels in their correct positions. 8) Replace the Junction Box Cover in its correct position (Remote Air-cooled model). 9) Turn on the power supply. 13. REMO V AL AND REPLA CEMENT OF W A TER V AL VE 1) Turn off the power su ...

  • Hoshizaki KM-630MRH - page 60

    60 3) Remove the Base Cover. 4) Drain the Water Tank by removing one end of the Pump Tubing. 5) Replace the removed parts in their correct positions. 6) Disconnect the Pump Suction and Discharge Hoses. 7) Remove the screws and the Pump Motor Bracket. 8) Remove the closed end connectors from the Pump Motor leads. 9) Remove the two screws and the Pum ...

  • Hoshizaki KM-630MRH - page 61

    61 VI. CLEANING AND MAINTENANCE INSTR UCTIONS IMPORT ANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. 1. PREP ARING THE ICEMAKER FOR LONG ST ORA GE W ARNING When shutting off the icemaker for an extended time, drain out all water from the water tank and remove the ...

  • Hoshizaki KM-630MRH - page 62

    62 [2] Remove the water from the potable water supply line: 1) Remove the Front Panel. (Except water-cooled model) 2) Move the Control Switch, on the Control Box, to the “OFF” position. 3) Wait 3 minutes. 4) Close the Potable Water Supply Line Shut-off Valve and open the Potable Water Supply Line Drain Valve. 5) Allow the line to drain by gravi ...

  • Hoshizaki KM-630MRH - page 63

    63 2. CLEANING AND SANITIZING PR OCEDURES IMPORT ANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. W ARNING 1. HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water condi- tions. 2. To ...

  • Hoshizaki KM-630MRH - page 64

    64 [a] CLEANING PROCEDURE 1) Dilute 16 fl. oz. of the recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY” (Economics Laboratory, Inc.) with 3 gal. of water. 2) Remove all ice from the Evaporator and the Storage Bin. Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after 3 minutes. The defrost cycle st ...

  • Hoshizaki KM-630MRH - page 65

    65 19) Replace the Front Panel in its correct position. 20) Turn on the power supply to fill the Water Tank with water. 21) Turn off the power supply after 3 minutes. 22) Remove the Front Panel, and fully open the Cleaning Valve. 23) Move the Control Switch to the “Wash” position. 24) Replace the Front Panel in its correct position. 25) Turn on ...

  • Hoshizaki KM-630MRH - page 66

    66 [b] SANITIZING PROCEDURE Following Cleaning Procedure 1) Dilute a 5.25 % Sodium Hypochlorite solution with water (Add 1.5 fl. oz. of sanitizer to 3 gal. of water). 2) Remove the Insulation Panel, if it is in its usual position. 3) Pour the sanitizing solution into the Water Tank. 4) Replace the Insulation Panel and the Front Panel in their corre ...

  • Hoshizaki KM-630MRH - page 67

    67 3. MAINTENANCE IMPORT ANT This icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker. 1) Stainless Steel Exterior To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use a damp cloth containing a neutral cleaner to wipe off oil or dirt build up. 2) Storag ...

Fabricante Hoshizaki Categoría Ice Maker

Los documentos del dispositivo Hoshizaki KM-630MRH que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Hoshizaki
- manuales de instrucciones KM-630MRH
- hojas de producto Hoshizaki
- folletos informativos
- o etiquetas energéticas Hoshizaki KM-630MRH
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Hoshizaki KM-630MRH.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Hoshizaki KM-630MRH, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Hoshizaki KM-630MRH. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Hoshizaki KM-630MRH.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Hoshizaki KM-630MRH, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Hoshizaki KM-630MRH. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Hoshizaki KM-630MRH.

El manual de instrucciones completo de Hoshizaki debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Hoshizaki KM-630MRH - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Hoshizaki KM-630MRH, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Hoshizaki KM-630MRH que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Hoshizaki KM-630MRH - que deben facilitarnos los primeros pasos durante el uso de Hoshizaki KM-630MRH
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Hoshizaki KM-630MRH
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Hoshizaki KM-630MRH en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Hoshizaki KM-630MRH?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Hoshizaki KM-630MRH, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Hoshizaki KM-630MRH probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)