    O A&M API f or Lin ux Operating Systems Pr ogramming Guide A ugust 2005 05-1850-00 4 ...

  • Intel 05-1850-004 - page 2

    OA&M API for Linux Programming Guide – August 2005 INFORMA TION IN THIS DO CUMENT IS PRO VIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED , BY EST OPPEL OR OTHER WISE, TO ANY INTELLECTU AL PROPER TY RIGHTS IS GRANTED BY THIS DOCUMENT . EXCEPT AS PRO VIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, ...

  • Intel 05-1850-004 - page 3

    OA&M API for Linu x Programming Guide – August 2005 3 Contents Revision H istory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 About This Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 ...

  • Intel 05-1850-004 - page 4

    4 OA&M API for Linux Programming Guide – August 2005 Contents Figures 1 OA&M API Clas ses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2 Event Notifi cation Framew ork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Intel 05-1850-004 - page 5

    OA&M API for Linu x Programming Guide — August 2005 5 Re vision Histor y This re vision history summarizes the changes made in each published vers ion of this document. Document No. Publication Date Description of Revisions 05-1850-004 A u gust 2005 General Guidelines section : Added information a bout freeing memor y that is allocated for ob ...

  • Intel 05-1850-004 - page 6

    6 OA&M API for Linux Progra mming Guide — August 2005 Revisi on History ...

  • Intel 05-1850-004 - page 7

    OA&M API for Linu x Programming Guide — August 2005 7 About This Pub lication The following topics provide information about this publicati on: • Purpose • Intended Audience • How to Use This Publication • Related Information Purpose This publication provides guid elines for building applications using the Operatio ns, Administration ...

  • Intel 05-1850-004 - page 8

    8 OA&M API for Linux Progra mming Guide — August 2005 About This Public ation The information in this guide is or ganized as follo ws: • Chapter 1, “Produ ct Description” provides an o vervie w of the O A&M A PI. • Chapter 2, “Event Handling” describes how to register with the O A&M event notification frame work and handle ...

  • Intel 05-1850-004 - page 9

    OA&M API for Linu x Programming Guide — August 2005 9 1 1 . Pr oduct Description This chapter describes the O A &M API. The following topi cs are included: • O A&M API Overvie w . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 • Features . . . . . . . . . . . . . . . . . . . . . ...

  • Intel 05-1850-004 - page 10

    10 OA&M API for Linux Progra mming Guide — August 2005 Produc t Description Figure 1. O A&M API Classes 1.2 Features The features av ai lable through the OA&M API include the following: • Get version information (major release number , release build number , service pack number, feature pack number , service update number , feature ...

  • Intel 05-1850-004 - page 11

    OA&M API for Linu x Programming Guide — August 2005 11 Pr oduct Descriptio n for Linux Operating Systems Library Refer ence for informatio n about the CTPLA TFORMVERSIONINFO data structure and the ICTNode::GetSystemRe leaseVersionInfo( ) function. • Get physical identification information (serial number, PCI slot number , number of network ...

  • Intel 05-1850-004 - page 12

    12 OA&M API for Linux Progra mming Guide — August 2005 Produc t Description Figure 2. Event Notification Frame work Intel ® Dialogic system software components, such as de vice driv ers and firmware, are the supplier objects. They generate e vents that are broadcas t to consumer objects via the e vent notif ication channels. The DlgAdminCons ...

  • Intel 05-1850-004 - page 13

    OA&M API for Linu x Programming Guide — August 2005 13 Pr oduct Descriptio n The framew ork cont ains the following e vent notif ication channels, each of which carries specific types of e vents: • ADMIN_CHANNEL • CLOCK_EVENT_CHANNEL • F A UL T_CHANNEL • NETWORK_ALARM_CHANNEL Notes: 1. DM3 architecture boards generate e vents on al l ...

  • Intel 05-1850-004 - page 14

    14 OA&M API for Linux Progra mming Guide — August 2005 Produc t Description ...

  • Intel 05-1850-004 - page 15

    OA&M API for Linu x Programming Guide — August 2005 15 2 2 . Event Handling This chapter provides informat ion about receiving and handling asynchronous ev ents that are transmitted via the event notif i cation framew o rk. For your application to receive e vents from the ev ent no tification frame work you must follow these steps: 1. Define ...

  • Intel 05-1850-004 - page 16

    16 OA&M API for Linux Progra mming Guide — August 2005 Event Handling ...

  • Intel 05-1850-004 - page 17

    OA&M API for Linu x Programming Guide — August 2005 17 3 3 . Err or Handling This chapter describes the error handling capabilities provided b y the O A&M API. When an error occurs during ex ecution of a function in one of the System Component classes (CCTDomain, ICTN ode, ICTBoard or ICTCl ockAgent) , an exception is thro wn. Exceptions ...

  • Intel 05-1850-004 - page 18

    18 OA&M API for Linux Progra mming Guide — August 2005 Error Handling ...

  • Intel 05-1850-004 - page 19

    OA&M API for Linu x Programming Guide — August 2005 19 4 4 . Application De velopment Guidelines This chapter provides informatio n about developing applications using the O A&M API. It includes the following sections: • General Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Intel 05-1850-004 - page 20

    20 OA&M API for Linux Progra mming Guide — August 2005 Application Development Gu idelines • ICTClockAgent::SetTDMBusConfiguration( ) 4.2 Designing CT Bus Cloc king Applications If you are using an y of ICTC lockAgent class me mber functions (for example, to dev elop a customized system clo cking daemon) you must disa ble the clocking daemo ...

  • Intel 05-1850-004 - page 21

    OA&M API for Linu x Programming Guide — August 2005 21 Application Development Guide lines 6. When the stopbrd utility successfully stops the board, use the removebrd ut ility to notify the system that the board is being removed. 7. Physically remo ve the board from the chass i s when the board’ s Out of Service (Blue) LED lights. 8. Insert ...

  • Intel 05-1850-004 - page 22

    22 OA&M API for Linux Progra mming Guide — August 2005 Application Development Gu idelines ...

  • Intel 05-1850-004 - page 23

    OA&M API for Linu x Programming Guide — August 2005 23 5 5 . Building Applications This chapter provides general information for building applications that use the O A&M librar y . The follo wing topics are in cluded in this chapter: • Compiling and Linking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Intel 05-1850-004 - page 24

    24 OA&M API for Linux Progra mming Guide — August 2005 Building Applications dlgeventproxydef.h defines the generic data structure for O A&M ev ents Note: User-def ined header files that pro v ide an implemen tation of the CEventHandlerAdaptor class (i.e., adminhandler.h) and override its CEventHandlerAdap tor::HandleEvent ( ) function al ...

  • Intel 05-1850-004 - page 25

    OA&M API for Linu x Programming Guide — August 2005 25 Inde x A array of filters 15 C CCTDasiException 9 , 17 CEventHandlerAdaptor 12 , 15 class heirarchy 11 , 19 client data 15 CT Bus 8 D dasi.h 23 devices virtual 20 DlgAdminConsumer 12 dlgadminconsumer.h 23 dlgadminevents.h 23 dlgadminmsg.h 23 dlgcclockinge vents.h 23 dlgcnetworkalarmevents ...

  • Intel 05-1850-004 - page 26

    26 OA&M API for Linux Progra mming Guide — August 2005 ...

Fabricante Intel Categoría Sleep Apnea Machine

Los documentos del dispositivo Intel 05-1850-004 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Intel
- manuales de instrucciones 05-1850-004
- hojas de producto Intel
- folletos informativos
- o etiquetas energéticas Intel 05-1850-004
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Intel 05-1850-004.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Intel 05-1850-004, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Intel 05-1850-004. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Intel 05-1850-004.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Intel 05-1850-004, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Intel 05-1850-004. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Intel 05-1850-004.

El manual de instrucciones completo de Intel debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Intel 05-1850-004 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Intel 05-1850-004, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Intel 05-1850-004 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Intel 05-1850-004 - que deben facilitarnos los primeros pasos durante el uso de Intel 05-1850-004
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Intel 05-1850-004
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Intel 05-1850-004 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Intel 05-1850-004?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Intel 05-1850-004, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Intel 05-1850-004 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)