    IWAKI AMERICA FA-2E AIR DRIVEN BELLOWS PUMP INSTRUCTION MANUAL ...

  • Raymarine FA-2E - page 2

    CONTENTS 1 INTRODUC TION ........................................................................................................ 3 2 UNPACKING AND IN SPECTION .............................................................................. 2 2.1 Operation Sequence ...................................................................................... ...

  • Raymarine FA-2E - page 3

    1 INTRODUCTION Thank you for selecting an Iwaki America FA-2E Air Driven Bellows Pump. These pumps are designed exclusively for pumping semiconductor grade, high p uri ty liquids. To ensure safety and maximum service life of the pump, please read this instruction ma nual thoroughly prior to installat ion and operation. CAUTION! 1. This instruction ...

  • Raymarine FA-2E - page 4

    2 2 UNPACKING AND INSPECTION Open the package and check that the product conforms to your order. Also check each of the following points. For any problem or inconsistency, contact Iwaki America at once. 1. Check that the model num ber indicated on the name plate conforms to the specifications of your order. 2. Check that the pump body and parts hav ...

  • Raymarine FA-2E - page 5

    3 2.1 Operation Sequence Refer to Figure 2. When pressurized air is supp lied to chamber 'a' of the pump, bellows 'A' is compressed and fluid is discharged from the bellows through the pu mp head discharge (outlet) port. Simultaneously, bellows 'B' is exte nded and fluid is drawn into the bellows through the pump head ...

  • Raymarine FA-2E - page 6

    4 2 IDENTIFICATION CODES 1 2 3 FA - 2E - W02 1. Series code: FA : Non-metallic pump for medium temperature liquid 2. Maximum discharge volume: 0.5 Gal/min (2L/min) 3. Special specifications No symbol: Threaded suction & discharge W02 : Tubing connections 3 SPECIFICATIONS 3.1 FA-2E Pump Specifications Max. discharg e volum e Note 1 0.5 GAL/mi n ...

  • Raymarine FA-2E - page 7

    5 3.2 Proximity Sensor Speci fications (for FA-2E pumps) Type High frequency oscillation switch Output system NPN DC open/close output Power source voltage 12-24 VDC ±10%, ripple (P-P): 10% max Current consumption 13 mA max Setting distance Less than 80% of the switching distance Hysteresis 10% max of detecting distance Switching distance 1.5mm (0 ...

  • Raymarine FA-2E - page 8

    6 3.3 FA-2E Pump Dimensions/Mass Mass: 8.6 lbs (3.7kg) Figure 4 ...

  • Raymarine FA-2E - page 9

    7 4 HANDLING PRECAUTIONS The following information deals with measures to ensure safe operation of the pump system. Please read the precautions carefully. To operate this pump, a 4-way solenoid valve and a controller (Iwaki America supplied m odel or host PLC) are required. In addition, to enhance system safety, a quick exhaust valve is recommended ...

  • Raymarine FA-2E - page 10

    8 4.2 Pump Handling Precautions • Do not stop pump without opening discharge first: When stopping pump operation, first release pressure in the discharge line & then shut off supply air pressure. Residual pressure in the liquid discharge pi ping may result in deformation of the bellows due to the force of hydraulic pressure. • Do not suspen ...

  • Raymarine FA-2E - page 11

    9 • Prohibited liquids: The following liquids must not be used: - Liquids that are easily crystallized - Liquids containing slurry - Solvent based fluids Service life of the valve and bellows is shortened by liquids that are easily crystallized or contain slurry. Some solvents may cause premature failure due to incompatability with liquid end mat ...

  • Raymarine FA-2E - page 12

    10 4.4 Liquid Circulation Syst em Design Recommendations In typical semiconductor wet process liquids, a catalyst such as H 2 O, O 3 or H 2 O 2 is added to the process liquid. The subsequent reaction generates heat a nd produces extreme gassing of the liquid. Measures should be taken to reduce the amount of gas laden liquid which can enter the pump ...

  • Raymarine FA-2E - page 13

    11 3. Another technique is to install an air detection sen sor in the suction port area, so that the auto valve is automatically opened by a signal sent out from the sen sor and the air elimination operation is initiated. 5 INSTALLATION, PIPING & WIRING 5.1 Installation 1. Pump installation position • In case of flooded suction system, set th ...

  • Raymarine FA-2E - page 14

    12 5.2 Piping 5.2.1 General 1. Carry out sufficient air blowing or flushing of tubi ng and connectors to remove foreign m atter from inside surfaces prior to connecting them with the pump. 2. Tube connections should be done such that the extra load of pi ping is not applied to the pump, use pipe supports as necessary. Supports also prevent the vibr ...

  • Raymarine FA-2E - page 15

    13 2. Install a filter or strainer with low piping resi stance on the sucti on piping to block the entrance of solid particles or wafer fragments. CAUTION! Wafer fragments inside the pump may get stuck in the bellows and cause damage. If solid matter clogs the pum p's valv es, internal suction or discharge volume may be affected with the norma ...

  • Raymarine FA-2E - page 16

    14 5.2.3 Air Piping It is critical that all pneumatic piping and component s be sized according to the porting of the pum p. Full port components with matching effective cross-sectional area are recommended. 1. Effective cross-sectional area indicates th e capacity to allow air to flow freely. When air is sent through a pipe, the air cannot run tot ...

  • Raymarine FA-2E - page 17

    15 2. Install a relief type regulating valve: Fluctuation of supply air pressure results in fluctu ation of the pum p stroke rate as well as discharge volume. Install a regulating valve to maintain the ai r pressure at a fixed level. Select the regulator based on the air consumption rate of the pump. Pressure drop rating of the regulator should be ...

  • Raymarine FA-2E - page 18

    16 Figure 9 Pneumatic Piping/Control (FA-2E shown) ...

  • Raymarine FA-2E - page 19

    17 5.4 Wiring instructions 5.4.1 General A. Extension of leak detector electrode wire: Keep the resistance value at 5K ohms or below. A resistance greater than the above may make it impossible to detect a conductivity change between the leak detection electrodes. (This is dependent on the controller system.) B. Wiring of proximity sensor: Isolate t ...

  • Raymarine FA-2E - page 20

    18 5.4.5 Wiring for proximity sensor CAUTION! The proximity sensors of the F series pump have three leads. Faulty wiring may cause the proximity sensor to short circuit. Carry out the wiring carefully and accurately. • Connect the leads of proximity sensor A with te rminals 6, 7, and 8 respectively of the controller. • Connect the leads of prox ...

  • Raymarine FA-2E - page 21

    19 6 OPERATION Carry out the following preparatory steps when starting pump operation for the first time after installation or after a long suspension of the pump operation. 1. Confirm that all liquid connectors along the liquid piping s ystem are fastened tightly. 2. Confirm that the valves on the suction and discharge piping (if appli cable) are ...

  • Raymarine FA-2E - page 22

    20 7 TROUBLESHOOTING TROUBLE CAUSES COUNTERMEASURES INSPECTION & CHECK POINTS Faulty operation of 4- way solenoid valve 1 Inspect and repair or rep lace. a Install qui ck e xhaust valves if damaged by corrosive gas Wrong wiring or disconnection in proximity sensor 1 Inspect and correct wiring. 2 Replace if shorted. a Check if the three wires ar ...

  • Raymarine FA-2E - page 23

    21 TROUBLE CAUSES COUNTERMEASURES INSPECTION & CHECK POINTS Liquid leaks. Bellows are damaged. 1 Replace pum p head. a Check if s upply air pressure is within the specification. b Check if pump stroke speed is within the specification. c Check if liqu id temperature is . within the specification. d Check if residual pressure is removed upon pum ...

Fabricante Raymarine Categoría Water Pump

Los documentos del dispositivo Raymarine FA-2E que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Raymarine
- manuales de instrucciones FA-2E
- hojas de producto Raymarine
- folletos informativos
- o etiquetas energéticas Raymarine FA-2E
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Raymarine FA-2E.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Raymarine FA-2E, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Raymarine FA-2E. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Raymarine FA-2E.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Raymarine FA-2E, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Raymarine FA-2E. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Raymarine FA-2E.

El manual de instrucciones completo de Raymarine debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Raymarine FA-2E - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Raymarine FA-2E, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Raymarine FA-2E que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Raymarine FA-2E - que deben facilitarnos los primeros pasos durante el uso de Raymarine FA-2E
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Raymarine FA-2E
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Raymarine FA-2E en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Raymarine FA-2E?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Raymarine FA-2E, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Raymarine FA-2E probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)