  • APC EPW9 - page 1

    Installation and Operation Emergency Power Off System test ...

  • APC EPW9 - page 2

    Legal Disclaimer The information presented in this manual is not warranted by the Schneider Electric IT Corporation to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed operational and site specic development plan. Therefore, Schneider Electric IT Corporation assumes no liability for damag ...

  • APC EPW9 - page 3

    T able of Contents IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS ............................................................................................................... 1 Safety Instructions for North America ................................................................... 1 Safety Instructions for Europe, Middle East, and Afri ...

  • APC EPW9 - page 4

    ii Emergency Power Of f System Installation and Operation 990–161 1C-001 ...

  • APC EPW9 - page 5

    IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation, operation, and maintenance of the EPO system. Safety Instructions for North America W ARNING: Only certied electricians may install the system and the wiring to the products IT controls. W ARNING: Assem ...

  • APC EPW9 - page 6

    Safety Instructions for Europe, Middle East, and Africa W ARNING: Only certied electricians may install the system and the wiring to the products IT controls. W ARNING: Assembly has not been evaluated for emergency life critical applications, but is intended for emergency equipment power off. Note: W iring from the system to the products IT cont ...

  • APC EPW9 - page 7

    Specications Electrical Input/Output V oltage 24 VDC 48 VDC/240 V AC (External circuit) Current 1 A at 24 VDC 1 A at 48 VDC (External circuit) Frequency 50/60 Hz Circuits (qty) 9 Contact state Normally Open (NO) Physical Dimensions (W×L×D) EPO box 226 × 251×66 mm (8.9×9.9×2.6 in) Shipping 305 × 305×140 mm (12×12×5.5 in) W eight EPO box ...

  • APC EPW9 - page 8

    Overview Emergency Power Off System The Emer gency Power Off (EPO) System consists of one or more wall-mounted, push-button EPO boxes. Each EPO box provides a single point of equipment shutdown for up to eight APC devices and one third-party device (such as an upstream breaker), using Normally Open (NO) contact closure connections. An EPO box can b ...

  • APC EPW9 - page 9

    Note: W iring, conduits, and mounting hardware are not provided. 990–161 1C-001 Emergency Power Off System Installation and Operation 5 ...

  • APC EPW9 - page 10

    Installation Prepare the EPO 1. Open the EPO System box by removing the screws on the side. Keep the screws for use after the system is installed. The box will not close securely without the screws in place. 2. Mount the system in a readily-accessible area, on a wall near the principal entrance doors, according to NEC Articles 645.10 and 645.1 1, I ...

  • APC EPW9 - page 11

    3. Install an appropriate tting with a lock-nut for each knockout used. 4. Connect conduits to the ttings. Note: If not using conduits, run the cables through the knockout directly . Mount the EPO (running conduits or cables behind the wall) One120mm(4in)squarejunctionbox T wo120mm(4in)squarejunctionb ...

  • APC EPW9 - page 12

    2. Run the conduits (or cables) from the connected devices to the junction or switch box. If using conduits, it will contain all wiring from the connected devices and all cascading cables. Remove the knockouts required for installation. Note: When planning conduit requirements, consider that two cascading cables will t in 13 mm (½ in) conduits ...

  • APC EPW9 - page 13

    7. Reinforce the EPO box with 6 mm (¼ in) screws in the corner mounting holes. Note: The top two 6 mm (¼ in) mounting holes may be blocked by some junction boxes. In this instance, use only the bottom two 6 mm (¼ in) mounting holes for reinforcement. Connect Devices to the EPO Box Connect APC devices to terminals 1–8. Connect an auxiliary devi ...

  • APC EPW9 - page 14

    5. Connect a suitable ground or PE wire to the #8-32 ground stud in the lower left corner of the EPO box. Mount Additional EPO Boxes There are two alternatives for wiring additional EPO boxes. Either cascade the boxes only to wire devices to one box (see “Cascade Multiple EPO Boxes“ ), or wire devices directly to each EPO box (see “Direct W i ...

  • APC EPW9 - page 15

    APC APC APC APC APC APC APC APC Note: The recommended maximum total distance of wire, to run per circuit is 300 m (1000 ft). Cascade the APC Devices with CA T -5 Cables Connect the CA T -5 cables to the jacks inside the EPO box. Each cable can support up to four APC device wire pairs. Follow these guidelines when connecting CA T -5 cables: • Use ...

  • APC EPW9 - page 16

    Cascade the Auxiliary Device with Wire Pairs 1. After wires are run from auxiliary device (1) to terminal block position 9, run a second set of wires (2) from terminal block position 9 on the rst EPO box to terminal block position 9 on the second EPO box. 2. Continue until all boxes are connected. (See the diagram in “Cascade Multiple EPO Boxe ...

  • APC EPW9 - page 17

    Note: If an APC FM Series Precision Air Conditioning System connected to the EPO box, pressing the check point will shut off functionality to the unit, but the unit will still be powered. B. After verifying the wiring, close the system box, making sure not to pin wires or disturb connections, and secure with the screws, previously removed when open ...

  • APC EPW9 - page 18

    Operation Engage the System 1. Lift the shield on any of the installed EPO boxes and press the button. A red ag will drop down from the box, providing an easy visual mark as to which EPO box in your room has been activated. Reset the EPO System 1. Pull the button towards you (1) and push the ag up until it catches (2). Pulling the button does ...

  • APC EPW9 - page 19

    Reset the Equipment Apply power to the devices according to the procedures for each device. Note: Refer to the operation manual included with each device for specic instructions on how to apply power to the device. 990–161 1C-001 Emergency Power Off System Installation and Operation 15 ...

  • APC EPW9 - page 20

    Wiring Diagram 16 Emergency Power Off System Installation and Operation 990–161 1C-001 ...

  • APC EPW9 - page 21

    990–161 1C-001 Emergency Power Off System Installation and Operation 17 ...

  • APC EPW9 - page 22

    ...

  • APC EPW9 - page 23

    ...

  • APC EPW9 - page 24

    Worldwide Customer Support Customer support is available at no charge via e-mail or telephone. Contact information is available at www .apc.com/support/contact © Schneider Electric. APC and the APC logo are owned by Schneider Electric Industries S.A.S. or their af liated companies. All other trademarks are property of their respective owners. 9 ...

Fabricante APC Categoría Power Supply

Los documentos del dispositivo APC EPW9 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos APC
- manuales de instrucciones EPW9
- hojas de producto APC
- folletos informativos
- o etiquetas energéticas APC EPW9
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones APC EPW9.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje APC EPW9, instrucciones de servicio, instrucciones cortas o instrucciones de usuario APC EPW9. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto APC EPW9.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo APC EPW9, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar APC EPW9. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de APC EPW9.

El manual de instrucciones completo de APC debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual APC EPW9 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice APC EPW9, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de APC EPW9 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo APC EPW9 - que deben facilitarnos los primeros pasos durante el uso de APC EPW9
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con APC EPW9
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de APC EPW9 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de APC EPW9?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con APC EPW9, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con APC EPW9 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)