Manual de instrucciones A.O. Smith GPVX-50

32 de páginas 1.36 mb
Descargar

Pasar a la página of 32

Summary
  • A.O. Smith GPVX-50 - page 1

    1 Instruction Manual PRINTED 1208 315465-000 KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. POWER VENTED GAS MODELS WITH HOT SURF ACE IGNITION NOT FOR USE IN MANUF ACTURED (MOBILE) HOMES ALL TECHNICAL AND W ARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE ...

  • A.O. Smith GPVX-50 - page 2

    2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety m ...

  • A.O. Smith GPVX-50 - page 3

    3 GENERAL SAFETY ...

  • A.O. Smith GPVX-50 - page 4

    4 SAFE INST ALLA TION, USE AND SERVICE............................2 GENERAL SAFETY..................................................................3 T ABLE OF CONTENTS ............................................................ 4 INTRODUCTION ......................................................................4 Preparing for the New Installatio ...

  • A.O. Smith GPVX-50 - page 5

    5 For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters insta lled in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated b y the Commonwealth and where the side wall exhaust vent termination is less than seven ...

  • A.O. Smith GPVX-50 - page 6

    6 TYPICAL INST ALLA TION GET TO KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe–Exhaust B V ent T erminal C V ent Adapter-Rubber Boot D Blower Assembly E Cold W ater Inlet F Inlet W ater Shut-off V alve G Union H Inlet Dip T ube J Anode** K Hot W ater Outlet L Outlet Receptacle (1 15 V AC) M T emperature-Pressure Relief V alve FIGURE 1. N Flu ...

  • A.O. Smith GPVX-50 - page 7

    7 TYPICAL INST ALLA TION FIGURE 2. MIXING V AL VE USAGE This appliance has been design certi fi ed as complying with American National Standard/CSA Standard for water heaters and is considered suitable for: W ater (Potable) Heating and Space Heating: All models are considered suitable for water (potable) heating and space heating. HOTTER W A TER C ...

  • A.O. Smith GPVX-50 - page 8

    8 F ACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Whe ...

  • A.O. Smith GPVX-50 - page 9

    9 and 12" (30.5 cm) from the top. (Standard clearance.) If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater . Adequate clearance for servicing this appliance should be considered before installation, such as changing the anodes, etc. A minimum clearance of 5" ...

  • A.O. Smith GPVX-50 - page 10

    10 Chemical vapor corrosion of the fl ue, blower assembly and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which ar ...

  • A.O. Smith GPVX-50 - page 11

    11 W A TER PIPING HOTTER W A TER CAN SCALD: W ater heaters are intended to produce hot water . Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than o ...

  • A.O. Smith GPVX-50 - page 12

    12 Figure 10 shows the typical attachment of the water piping to the water heater . The water heater is equipped with 3/4 inch NPT water connections. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connection. Do not solder the cold water supply line directly to the cold water inlet. It ...

  • A.O. Smith GPVX-50 - page 13

    13 GAS PIPING Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (3.5 kPa) for natural and propane gas (L.P .). The minimum inlet gas pressure shown on the rating plate is that which will permit fi ring at rated input. All gas piping must comply with local codes ...

  • A.O. Smith GPVX-50 - page 14

    14 SEDIMENT TRAPS A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fi tting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. If a tee fi tting is used, it shall be installed ...

  • A.O. Smith GPVX-50 - page 15

    15 VENT CONNECTIONS TO BLOWER ASSEMBL Y Figure 15 shows the optimal placement of the 2" to 3" or 3" to 4" reducer; however , the vent can be reduced at any point in the vent system as long as the maximum and minimum vent length requirements are met. FIGURE 15. VENTING AND INST ALLA TION Plan the layout of the vent system from th ...

  • A.O. Smith GPVX-50 - page 16

    16 The unit may be vented horizontally through a wall or vertically through the roof. Pipe runs must be adequately supported along both vertical and horizontal runs as follows: • For Schedule 40, 2" PVC, ABS, Coex Cellular Core vent pipe: Every 3 feet (0.9 m). • For Schedule 40, 3" PVC, ABS, Coex Cellular Core vent pipe: Every 3.5 fee ...

  • A.O. Smith GPVX-50 - page 17

    17 For 4" V enting, the maximum equivalent feet of pipe allowed is 160 feet (48.8 m). This does not include the V ent T ermination (supplied locally) for the water heater . For the 4" venting, one 90° elbow is approximately equal to 8 feet (2.4 m). One 45° elbow is approximately equal to 4 feet (1.2 m). It is recommended that at least 2 ...

  • A.O. Smith GPVX-50 - page 18

    18 FIGURE 16. This unit can vent through 2", 3" or 4" nonmetallic pipe and fi ttings. The vent pipe installation can be started from either the blower discharge or the termination wall. Keep in mind the total vent system (pipe and elbows) when installing the vent system, see VENTING AND INST ALLA TION, pages 15 - 17. FIGURE 17. The ...

  • A.O. Smith GPVX-50 - page 19

    19 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the speci fi c application you are attempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C . Know the reputation of your manufacturer and ...

  • A.O. Smith GPVX-50 - page 20

    20 B. Deburring Use a knife, plastic pipe deburring tool, or fi le to remove burrs from the end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°-15° should be added to the end to permit easier insertion of the pipe into the end of the fi tting. F ...

  • A.O. Smith GPVX-50 - page 21

    21 ...

  • A.O. Smith GPVX-50 - page 22

    22 Due to the nature of the typical gas water heater , the water temperature in certain situations may vary up to 30°F (16.7°C) higher or lower at the point of use such as, bathtubs, showers, sink, etc. It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all cases, that the water te ...

  • A.O. Smith GPVX-50 - page 23

    23 FOR YOUR INFORMA TION ST ART UP CONDITIONS CONDENSA TE Whenever the water heater is fi lled with cold water, some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensate. This usually happens when: a. A new water heater is fi lled with cold water for the fi rst time. b. Burning ...

  • A.O. Smith GPVX-50 - page 24

    24 VENTING SYSTEM INSPECTION At least once a year a visual inspection should be made of the venting system. Y ou should look for: 1. Obstructions which could cause improper venting. The combustion and ventilation air fl ow must not be obstructed. 2. Damage or deterioration which could cause improper venting or leakage of combustion products. Be su ...

  • A.O. Smith GPVX-50 - page 25

    25 INST ALLED IN SUIT ABLE AREA: T o insure suf fi cient ventilation and combustion air supply , proper clearances from the water heater must be maintained. See “Locating the New W ater Heater” section. Combustible materials such as clothing, cleaning materials, or fl ammable liquids, etc. must not be placed against or adjacent to the water h ...

  • A.O. Smith GPVX-50 - page 26

    26 LEAKAGE CHECKPOINTS Read this manual fi rst. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water . Never use this water heater unless it is completely fi lled with water . T o prevent damage to the tank, the tank must be fi lled w ...

  • A.O. Smith GPVX-50 - page 27

    27 Key No. Part Description 1 Burner Assembly 2 Burner Head 3 Burner Ori fi ce 4 Burner T ube 5 HSI Ignition Assembly 6 Inner Door 7 Inner Door Gasket 8 Flue Baf fl e 9 Flue Restrictor 10 Blower Assembly 1 1 Air Intake Screen - Base Pan 12 Inlet T ube 13 Gas Control V alve 14 Drain V alve 15 Drain V alve Washer 16 Outer Door (may appear different ...

  • A.O. Smith GPVX-50 - page 28

    28 TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a quali fi ed service technician. Read the GENERAL SAFETY INFORMA TION section fi rst. ...

  • A.O. Smith GPVX-50 - page 29

    29 ...

  • A.O. Smith GPVX-50 - page 30

    30 These guidelines should be utilized by a quali fi ed service agent. When calling for service notify the service agent that this is a “Flammable V apor Ignition Resistant” Product. TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES Figure 1 and 15. Page 9. ...

  • A.O. Smith GPVX-50 - page 31

    31 THIS W ARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . If the glass lined tank in this water heater shall prove upon examination by (the warrantor) to have leaked during the warranty period in normal residential use, due to natural corrosion from potable water therein, the warrantor will furnish the ORIGINAL OWNER a replacement water heater ...

  • A.O. Smith GPVX-50 - page 32

    32 ...

Fabricante A.O. Smith Categoría Water Heater

Los documentos del dispositivo A.O. Smith GPVX-50 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos A.O. Smith
- manuales de instrucciones GPVX-50
- hojas de producto A.O. Smith
- folletos informativos
- o etiquetas energéticas A.O. Smith GPVX-50
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones A.O. Smith GPVX-50.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje A.O. Smith GPVX-50, instrucciones de servicio, instrucciones cortas o instrucciones de usuario A.O. Smith GPVX-50. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto A.O. Smith GPVX-50.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo A.O. Smith GPVX-50, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar A.O. Smith GPVX-50. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de A.O. Smith GPVX-50.

El manual de instrucciones completo de A.O. Smith debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual A.O. Smith GPVX-50 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice A.O. Smith GPVX-50, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de A.O. Smith GPVX-50 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo A.O. Smith GPVX-50 - que deben facilitarnos los primeros pasos durante el uso de A.O. Smith GPVX-50
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con A.O. Smith GPVX-50
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de A.O. Smith GPVX-50 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de A.O. Smith GPVX-50?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con A.O. Smith GPVX-50, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con A.O. Smith GPVX-50 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)