Manual de instrucciones Lennox International Inc. GWB8-262E-2

32 de páginas 0.98 mb
Descargar

Pasar a la página of 32

Summary
  • Lennox International Inc. GWB8-262E-2 - page 1

    P/N# 240009276, Rev . A [03/2012] RET AIN THESE INSTRUCTIONS FOR FUTURE REFERENCE These instructions must be af fi xed on or adjacent to the boiler . GAS FIRED BOILER INST ALLA TION INSTRUCTIONS PRODUCT LITERA TURE Lennox Industries Inc. Dallas, T exas This boiler cannot be used with all types of chimneys. R ead these instructions carefully before ...

  • Lennox International Inc. GWB8-262E-2 - page 2

    2 1 - DIMENSIONS Table 1 - Dimensions BOILER MODEL NUMBER DIMENSIONS (INCH.) FLUE DIAMETER “A” WIDTH GWB8-245E-2/GWB8-262E-2 72 7 ½ GWB8-280E-2/GWB8-299E-2 7 30¾ Add 5½” to height for vent Damper . Figure 1 - Dimensions ...

  • Lennox International Inc. GWB8-262E-2 - page 3

    3 2 - BOILER RATINGS AND CAPACITIES Table 2 - Ratings and Capacities BOILER MODEL NUMBER (1) † NATURAL GAS † PROPANE GAS AFUE Input (3) Mbh Heating Capacity (3) Mbh (2) NET AHRI RATING Water, (3) Mbh HIGH ALTITUDE INPUT (3) Mbh INPUT (3) Mbh HEATING CAPACITY (3) Mbh (2) NET AHRI RATING Water, (3) Mbh HIGH ALTITUDE INPUT (3) Mbh INTERMITTENT IGN ...

  • Lennox International Inc. GWB8-262E-2 - page 4

    4 3 - TABLE OF CONTENTS IMPORT ANT : Read the following instructions COMPLETEL Y before installing!! KEEP THIS MANUAL NEAR BOILER RETAIN FOR FUTURE REFERENCE WARNING K eep boiler area clear and free from combustible materials, gasoline and other fl ammable vapors and liquids. DO NO T obstruct air openings to the boiler room. Modi fi cation, subst ...

  • Lennox International Inc. GWB8-262E-2 - page 5

    5 4 - INSTALLATION PROCEDURE Table 3 - MINIMUM CLEARANCE DIMENSIONS Inches (mm) T op 6” (152mm) Rear 6” (152mm) Control Side 7” (178mm) Opposite Side 6” (152mm) Front 18” (457mm) Flue/V ent Connector 6” (152mm) Near Boiler Piping 1/2” (13mm) WARNING Improper installation, adjustment, alteration, service or maintenance could result in ...

  • Lennox International Inc. GWB8-262E-2 - page 6

    6 5 - VENTILATION & COMBUSTION AIR Provide combustion air and ventilation air in accordance with the section “Air for Combustion and Ventilation,” of the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Sections 8.2, 8.3 or 8.4 of Natural Gas and Propane Installation Code, CAN/CSA B149.1, or applicable provisions of local building codes. Pro ...

  • Lennox International Inc. GWB8-262E-2 - page 7

    7 6 - CONNECTING SUPPLY AND RETURN PIPING RELIEF VALVE DISCHARGE LINE Check local codes for maximum distance from fl oor or allowable safe point of discharge . WARNING Burn or Scald Hazard. Discharge line shall be installed to relief valv e outlet connection to avoid burns, scalding, or water damage due to discharge of steam and/or hot water durin ...

  • Lennox International Inc. GWB8-262E-2 - page 8

    8 6 - CONNECTING SUPPLY AND RETURN PIPING WARNING Burn and scald hazard. Safety relief valv e could discharge steam or hot water during oper ation. In- stall discharge piping per these instructions. ! Figure 3 - Temperature Pressure Gauge V erify clean water supply is av ailable to water inlet valv e. Install sand strainer when w ater supply is fro ...

  • Lennox International Inc. GWB8-262E-2 - page 9

    9 Figure 5 - Chilled Water Piping Figure 4 - Typical Hot Water Piping 6 - CONNECTING SUPPLY AND RETURN PIPING ...

  • Lennox International Inc. GWB8-262E-2 - page 10

    10 Figure 6 - BYPASS PIPING - CIRCULATOR ON SUPPLY Figure 7 - BYPASS PIPING - CIRCULATOR ON RETURN Bypass Piping Required For High Mass (Large Water Content) Systems 6 - CONNECTING SUPPLY AND RETURN PIPING ...

  • Lennox International Inc. GWB8-262E-2 - page 11

    11 Boilers connecting to gas vents or chimneys, vent installations shall be in accordance with “V enting of Equipment” , of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or “Venting Systems and Air Supply for Appliances,” of the Natural Gas and Propane Installation Code, CAN/CSA B149.1, or applicable provisions of the local building codes ...

  • Lennox International Inc. GWB8-262E-2 - page 12

    12 Minimum Vent Pipe Clearance W ood and other combustible materials must not be closer than 6” from any surface of single wall metal vent pipe. Listed T ype B vent pipe or other listed venting systems shall be installed in accordance with their listing. Removing E xisting B oiler F rom C ommon Venting S ystem When an existing boiler is removed f ...

  • Lennox International Inc. GWB8-262E-2 - page 13

    13 8 - VENT DAMPER OPERATION Figure 8 - Vent Damper Installation Figure 9 - Vent Damper Placement Annually check vent damper and all fl ue product carrying areas of appliance, with particular attention given to deterior ation from corrosion or other sources. If you see corrosion or other deterior ation, contact your heating contr actor for repairs ...

  • Lennox International Inc. GWB8-262E-2 - page 14

    14 9 - GAS SUPPLY PIPING CAUTION WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow gas supplier’s instructions. • If you cannot reach your gas supplier, call the fi re departme ...

  • Lennox International Inc. GWB8-262E-2 - page 15

    15 10 - ELECTRICAL WIRING Electrically bond boiler to ground in accordance with requirements of authority having jurisdiction. R efer to: • USA- National Electrical Code, ANSI/NFPA 70. • Canada - Canadian Electrical Code, Part I, CSA C22.1: Safety Standard for Electrical Installations. ELECTRIC POWER SUPPLY Run separ ate 120 volt circuit from s ...

  • Lennox International Inc. GWB8-262E-2 - page 16

    16 11 - WIRING DIAGRAMS Figure 12 - Integrated High Limit Electronic Ignition Control (240008781) I Inducer is not an option. WARNING Modi fi cation, substitution or elimination of factory equipped, supplied or speci fi ed components may result in personal injury or loss of life. ! ...

  • Lennox International Inc. GWB8-262E-2 - page 17

    17 11 - WIRING DIAGRAMS Figure 13 - Integrated High Limit Electronic Ignition Control (240008781) ...

  • Lennox International Inc. GWB8-262E-2 - page 18

    18 11 - WIRING DIAGRAMS Figure 14 - Integrated High Limit Electronic Ignition Control (240008781) ...

  • Lennox International Inc. GWB8-262E-2 - page 19

    19 12 -GENERAL INSTRUCTIONS FILLING SYSTEM WITH WATER • Close air vents on all radiation units. Open valves to these units. • Verify boiler and expansion tank drain valves are closed. • Air bleed screw on tank drain fi tting should be closed. • Open valve in line from boiler to expansion tank. Open water inlet to your boiler and leave it o ...

  • Lennox International Inc. GWB8-262E-2 - page 20

    20 13 - LIGHTING INSTRUCTIONS 1. STOP! R ead the safety information above. 2. Set the thermostat to lowest setting. 3. T urn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. OFF ON INLET GAS CONTROL KNOB PILOT ADJUSTMENT (UNDER ...

  • Lennox International Inc. GWB8-262E-2 - page 21

    21 14 - OPERATING YOUR BOILER AUTOMATIC GAS VALVE Automatic Gas V alve opens or closes according to heat requirements of thermostat and temperature limit control. It closes if pilot goes out. Each individual control must be operating correctly before any gas can pass to burners. Any one control can hold gas supply from burner regardless of demand o ...

  • Lennox International Inc. GWB8-262E-2 - page 22

    22 14 - OPERATING YOUR BOILER CHECK THERMOSTAT OPERATION A. When set above temperature indicated on thermo stat, boiler should ignite. B. Verify thermostat turns boiler off when room temperature reaches selected setting and starts boiler operating when room temperature falls a few degrees. C. After setting limit control to limit setting, check to s ...

  • Lennox International Inc. GWB8-262E-2 - page 23

    23 15 - MAINTAINING YOUR BOILER BURNERS Beginning of heating season visually check pilot and main burner fl ames. See Figure 16. SAFETY RELIEF VALVE Refer to page 7 for important information. T o test safety relief valv e refer to valv e manufacturer’s instructions packaged with relief valv e. Call T echnical Support if manufacturer’s instruct ...

  • Lennox International Inc. GWB8-262E-2 - page 24

    24 EQUIPMENT AND OPTIONAL AC CESSORIES - WHA T THEY DO 16 - SERVICE HINTS You may avoid inconvenience and service calls by checking these points before you call for service. Possible Cause What to do Thermostat is not set correctly Reset thermostat abov e room temperature Burner is not operating properly Check fl ame. If it is y ellow , burner is ...

  • Lennox International Inc. GWB8-262E-2 - page 25

    25 17 - EQUIPMENT AND OPTIONAL ACCESSORIES EXPANSION TANK Expanding water fl ows into expansion tank. T ank should be correct size. T ank is fi lled with air . As water expands it compresses air in the tank to form air pressure cushion. This “spring-like” cushion serves to maintain correct operating w ater pressure regardless of water temper ...

  • Lennox International Inc. GWB8-262E-2 - page 26

    26 BLOCKED VENT SAFETY SWITCH (BLOCKED VENT SAFETY SHUTOFF) Blocked vent safety switch is manual reset disc thermostat with fi xed setpoint (340°F (171°C)), and normally closed contacts. It is located at relief opening of integral draft diverter. In event of chimney or venting system blockage causing products of combustion to spill out of relief ...

  • Lennox International Inc. GWB8-262E-2 - page 27

    27 APPENDIX A - CONTROL MODULE A.1 Installation Environment Considerations WARNING If you do not follow these instructions ex actly, a fi re or explosion may result causing property damage, personal injury or loss of life. • Do not use this appliance if any part has been under water. Immediately call a quali fi ed service technician to inspect ...

  • Lennox International Inc. GWB8-262E-2 - page 28

    28 APPENDIX A - CONTROL MODULE A.5 Operation Module continuously monitors boiler water temper ature and fi res or shuts off burner based on this temperature data. 1. When “Call for Heat” occurs, control enables circulator and monitors boiler water temperature to determine whether thermostat can be satis fi ed without fi ring burners. 2. Cont ...

  • Lennox International Inc. GWB8-262E-2 - page 29

    29 APPENDIX A - CONTROL MODULE A.6 Boiler High Limit Temperature Controller • When water temperature reaches setpoint, controller ends heating cycle. • When water temperature drops below setpoint minus differential, controller restarts heat cycle to re-heat boiler water. • If water temperature exceeds maximum allowed temperature (220°F or 10 ...

  • Lennox International Inc. GWB8-262E-2 - page 30

    30 APPENDIX A - CONTROL MODULE Table 7 - Troubleshooting Error Codes Error Code Number De fi nition Consequence 4 Flame current too low . Check for fl ame. Non critical alarm 6 Flame sensed out of normal sequence (before opening or after closing gas valv e). Soft lockout 18 Gas valv e relays welded. Five consecutiv e soft lockouts. Hard lockout 2 ...

  • Lennox International Inc. GWB8-262E-2 - page 31

    31 APPENDIX A - CONTROL MODULE — If fl ame rod or bracket is bent out of position, restore to correct position. STEP 3: Check spark ignition circuit. Disconnect ignition cable at SPARK terminal on module. WARNING Electrical shock hazard. Ignition circuit generates over 10,000 v olts. T urn OFF electrical power supply at service panel before maki ...

  • Lennox International Inc. GWB8-262E-2 - page 32

    PRODUCT LITERA TURE Lennox Industries Inc. Dallas, T exas Manufactured by: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: www .ecrinternational.com ...

Fabricante Lennox International Inc. Categoría Boiler

Los documentos del dispositivo Lennox International Inc. GWB8-262E-2 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lennox International Inc.
- manuales de instrucciones GWB8-262E-2
- hojas de producto Lennox International Inc.
- folletos informativos
- o etiquetas energéticas Lennox International Inc. GWB8-262E-2
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lennox International Inc. GWB8-262E-2.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lennox International Inc. GWB8-262E-2, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lennox International Inc. GWB8-262E-2. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lennox International Inc. GWB8-262E-2.

El manual de instrucciones del dispositivo Lennox International Inc. GWB8-262E-2, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lennox International Inc. GWB8-262E-2. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lennox International Inc. GWB8-262E-2.

El manual de instrucciones completo de Lennox International Inc. debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lennox International Inc. GWB8-262E-2 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lennox International Inc. GWB8-262E-2, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lennox International Inc. GWB8-262E-2 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lennox International Inc. GWB8-262E-2 - que deben facilitarnos los primeros pasos durante el uso de Lennox International Inc. GWB8-262E-2
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lennox International Inc. GWB8-262E-2
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lennox International Inc. GWB8-262E-2 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lennox International Inc. GWB8-262E-2?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lennox International Inc. GWB8-262E-2, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lennox International Inc. GWB8-262E-2 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen