  • Fluke Thermal Imagers Ti10 - page 1

    PN 28 03044 Augus t 200 7 © 2007 Fluk e C orporati on, Al l ri ghts r eserve d. Pri nted i n USA All pro duct n ames are tr adem arks of their r espectiv e c ompani es. Ti 1 0 , Ti 2 5 , Ti R a n d Ti R 1 Thermal Imagers Users Manual ...

  • Fluke Thermal Imagers Ti10 - page 2

    LIMITED WARRANTY AND LIMI TATION OF LIABILITY Each Fl uke p roduc t is w arran ted to be f ree fr om def ects in ma teri al and workm anshi p und er no rmal use an d servic e. The wa rranty perio d is two yea rs and begins on th e dat e of sh ipme nt. Part s, pro duc t repairs, and s ervi ces ar e warr anted for 90 days . Thi s war ranty e xtends o ...

  • Fluke Thermal Imagers Ti10 - page 3

    i Table of Contents Title Page Introduction ............................................................................... 1 Contacting Fluk e ....................................................................... 1 Safety Inf ormation ..................................................................... 2 Unpacking th e Imager .................. ...

  • Fluke Thermal Imagers Ti10 - page 4

    Ti10, Ti25, TiR and TiR1 Users Man ual ii Changing the SD Card ............................................................... 15 Setting the Backlight .................................................................. 15 General Specifications ............................................................... 15 Detailed Specifications .............. ...

  • Fluke Thermal Imagers Ti10 - page 5

    iii List of Tables Table Title Page 1. Symbols ..................................................................................... 2 2. Features and C ontrols ................................................................ 4 List of Figures Figure Title Page 1. Range an d Span Settings ........................................................... ...

  • Fluke Thermal Imagers Ti10 - page 6

    Ti10, Ti25, TiR and TiR1 Users Man ual iv ...

  • Fluke Thermal Imagers Ti10 - page 7

    1 Introduction The Fluke Ti10, Ti25, TiR, and TiR1 Thermal Im agers (hereafter “the Imager”) are handheld im aging cam eras used for p redictive main tenance, equipm ent troublesho oting, an d verificatio n. All fou r Imagers prod uce therm al and visual imag es on a 640 X 480 disp lay. Thermal and visual im ages are displayed on the Im ager LC ...

  • Fluke Thermal Imagers Ti10 - page 8

    Ti10, Ti25, TiR and TiR1 Users Man ual 2 Safety Informatio n Use the Imager on ly as specified in this manual. See Table 1 for a lis t of sym bols us ed on t he Imag er and in th is manu al. A Wa rning identifies haz ardous co nditio ns an d acti ons tha t could c ause bodily harm or death. A Ca ution identi fies conditions and actions that could d ...

  • Fluke Thermal Imagers Ti10 - page 9

    Thermal Imagers Unpackin g the Im ager 3 Unpacking the Imager Carefully unpack the follo wing items: • Ti1 0, Ti 25, Ti R or Ti R 1 Im ag e r • AC Power Adapt er/Ch arger • Rug ge d Car r yi ng Case • SD Memory Card • SD Card Reader • Soft Transport Bag • User Manu als (in various langu ages) • SmartVie w™ Soft ware • Warranty R ...

  • Fluke Thermal Imagers Ti10 - page 10

    Ti10, Ti25, TiR and TiR1 Users Man ual 4 Table 2. Features and Controls 8 1 4 5 6 9 2 7 3 10 11 12 14 13 exj01.eps Item Description 1 LCD Disp lay 2 Function Softkey s (F1. F2, and F3) 3 Battery Cover 4 Speaker 5 Microph one 6 Auto backlig ht sen sor 7 Hand strap 8 AC adapter/c harger in put t erminal ...

  • Fluke Thermal Imagers Ti10 - page 11

    Thermal Imagers Using the Menu 5 Table 2. Fe atures and Contr ols (cont.) Item Description 9 SD mem ory card com partm ent 10 Retractabl e Lens Cover 11 Visual camera 12 Thermal (IR) camera 13 Focus contro l 14 Trigger Using the Menu The menus , coupled with the three s oftkeys ( c , a , and d ), provide access for setting features (date, tim e, la ...

  • Fluke Thermal Imagers Ti10 - page 12

    Ti10, Ti25, TiR and TiR1 Users Man ual 6 Setting the Date To set the date: 1. Pre ss a until Date appears over the F1 sof tkey. 2. Press the soft ke y labeled Date . The date can be dis play ed in one of two f ormats: MM/DD/Y Y or DD/MM/YY . 3. Press the softke y labeled w ith the desir e d date for mat. 4. Press the soft ke y labeled Up ( c ) or D ...

  • Fluke Thermal Imagers Ti10 - page 13

    Thermal Imagers Saving Im ager D ata 7 Note Minim um focus dis tance for thermal ( IR) camera is 15 cm ( approx. 6 inches) . Mini mum focus di stance f or vis ible ( vis ual) l ight camera i s 46 cm (appr ox. 18 i nches ). Note The Imager can s ave t he image as a si mple pict ure or as a radiomet ric i mage that all ows f urther temper ature analy ...

  • Fluke Thermal Imagers Ti10 - page 14

    Ti10, Ti25, TiR and TiR1 Users Man ual 8 Selecting a P alette The palette menu provides di fferent thermal vie wing patterns. Gra yscale, Blue- Red, High C ontrast, an d Ironbow are av ailable in all four Imagers . The TiR1 and Ti25 add Amber and Hot Metal to the list. T o select a palette: 1. Pre ss a until Palette appears over c . 2. Press the so ...

  • Fluke Thermal Imagers Ti10 - page 15

    Thermal Imagers Adjustin g the Therm al Im age 9 T otal Imager Range Span Le v el exj02.eps Figure 1. Range and Span S e ttings Setting the L evel (Manual) When put into manual ran ging, the level setti ng adjusts the ther mal span within the total temperature range o f the I mager. See Figure 1. To set th e level: 1. After en tering the manual ran ...

  • Fluke Thermal Imagers Ti10 - page 16

    Ti10, Ti25, TiR and TiR1 Users Man ual 10 2. Press the soft ke y labeled In crease to widen th e temperature span or Decreas e to narro w it. 3. Press the soft ke y labeled Done to set the I mager’s range level. Switching Between PI P and Full IR (Ti10 and TiR Onl y) The Imager can be set to display a fu ll in frared im age (Full IR) or an infrar ...

  • Fluke Thermal Imagers Ti10 - page 17

    Thermal Imagers Adding Voi ce Annot ation to S aved Data (T i25 and T iR1 Onl y) 11 4. Press the soft ke y labeled Up to display the previous image or Down to display the next s tored image. To delete a singl e Image fro m the SD card: 1. Perform t he st eps under viewing stored im ages above to brin g the des ired image to the displa y. 2. Press t ...

  • Fluke Thermal Imagers Ti10 - page 18

    Ti10, Ti25, TiR and TiR1 Users Man ual 12 Listeni ng to Voice Annot ations (Ti2 5 and TiR1 Only) To play the v oice annotation already st ored wi th an image on th e SD card: 1. Perform the st eps in the “Reviewing and Deleting Stored Imag es” s ection to bring th e desired imag e to the Imager’s dis play. 2. Press the soft ke y labeled Sele ...

  • Fluke Thermal Imagers Ti10 - page 19

    Thermal Imagers Setting Em issivity (Ti25 an d TiR1 only) 13 the object's surface. The Im ager detects the inf rared energy from an object and uses this information to esti mate the temperature of the obj ect. Mo st of the objects m easured s uch as painted m e tal, w ood, w ater, skin, and cl oth are v ery efficient at radiating en ergy and i ...

  • Fluke Thermal Imagers Ti10 - page 20

    Ti10, Ti25, TiR and TiR1 Users Man ual 14 To set the emissi vity value dir ectly: 1. Press the soft ke y labeled ε . 2. Press the soft ke y labeled Up or Down to increm e nt or decrement respectively the emissivity value displayed just above the softkey labels . 3. Press the soft ke y labeled Done to select the se t value. Setting File For mat Dat ...

  • Fluke Thermal Imagers Ti10 - page 21

    Thermal Imagers Changing t he SD Card 15 Changing the SD Card To eject an SD card from the Imag er, press in on the exposed edge of the SD card and th en releas e. The card sh ould pop parti ally out after releasin g it. Carefu lly pu ll the card ou t of the slot . Note The SD Car d can be i nsert ed and removed w hile the Imager is in operation. T ...

  • Fluke Thermal Imagers Ti10 - page 22

    Ti10, Ti25, TiR and TiR1 Users Man ual 16 Soft ware ................................................................SmartV iew™ full analysi s and reporting s oftware included Power Battery ...............................................................Rec hargeable ba ttery pack ( i ncluded) Battery Li fe ........................................ ...

  • Fluke Thermal Imagers Ti10 - page 23

    Thermal Imagers Detailed Speci ficati ons 17 Detailed Specifica tions Temperature Measurements Temperature Range (not calibrated below -10 ° C) TiR and Ti R1 ................................................. -20 ° C t o +100 ° C Ti10 ............................................................... -20 ° C to +250 ° C Ti25 ...................... ...

  • Fluke Thermal Imagers Ti10 - page 24

    Ti10, Ti25, TiR and TiR1 Users Man ual 18 Ti10 ............................................................ 5 ° C Ti25, TiR, and TiR1 ....................................2. 5 ° C Minim um span (in auto mode) Ti10 ............................................................ 10 ° C Ti25, TiR, and TiR1 ....................................5 ° C IR- ...

Fabricante Fluke Categoría Digital Camera

Los documentos del dispositivo Fluke Thermal Imagers Ti10 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Fluke
- manuales de instrucciones Thermal Imagers Ti10
- hojas de producto Fluke
- folletos informativos
- o etiquetas energéticas Fluke Thermal Imagers Ti10
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Fluke Thermal Imagers Ti10.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Fluke Thermal Imagers Ti10, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Fluke Thermal Imagers Ti10. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Fluke Thermal Imagers Ti10.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Fluke Thermal Imagers Ti10, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Fluke Thermal Imagers Ti10. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Fluke Thermal Imagers Ti10.

El manual de instrucciones completo de Fluke debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Fluke Thermal Imagers Ti10 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Fluke Thermal Imagers Ti10, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Fluke Thermal Imagers Ti10 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Fluke Thermal Imagers Ti10 - que deben facilitarnos los primeros pasos durante el uso de Fluke Thermal Imagers Ti10
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Fluke Thermal Imagers Ti10
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Fluke Thermal Imagers Ti10 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Fluke Thermal Imagers Ti10?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Fluke Thermal Imagers Ti10, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Fluke Thermal Imagers Ti10 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)