    1 W415-0583 / B / 05.23.07 INST ALLA TION AND OPERA TION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED T O AND REMAIN WITH THE HOMEOWNER. GD82NT -T NA TURAL GAS GD82PT -T PROP ANE W ARN ...

  • Napoleon GD82NT-T - page 2

    2 W415-0583 / B / 05.23.07 PG 2-5 INTRODUCTION W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING V ent lengths V enting Specifi cations Air T erminal Locations 10-15 INST ALLA TION/FRAMING W all & Ceiling Protection Using Flexible V ent Components Fireplace V ent Connection Using Rigid V ...

  • Napoleon GD82NT-T - page 3

    3 W415-0583 / B / 05.23.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. N APOLEON® products are manuf actured under the strict Standard of the ...

  • Napoleon GD82NT-T - page 4

    4 W415-0583 / B / 05.23.07 Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fi replace. Never obstruct the front opening of the fi replace. Objects placed in front ...

  • Napoleon GD82NT-T - page 5

    5 W415-0583 / B / 05.23.07 24" 16" 8" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer . DO NOT SUB- STITUTE MA TERIALS. Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace ...

  • Napoleon GD82NT-T - page 6

    6 W415-0583 / B / 05.23.07 VER TICAL RISE IN FEET V T FIGURE 4 when (H T ) < (V T ) Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T ...

  • Napoleon GD82NT-T - page 7

    7 W415-0583 / B / 05.23.07 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H ...

  • Napoleon GD82NT-T - page 8

    8 W415-0583 / B / 05.23.07 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T when (H T ) < (V T ) FIGURE 9 For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T < 40 feet See graph to ...

  • Napoleon GD82NT-T - page 9

    9 W415-0583 / B / 05.23.07 FIGURE 12 ...

  • Napoleon GD82NT-T - page 10

    10 W415-0583 / B / 05.23.07 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer . See Accessories to order the specifi c kit required. 1 . Determine the air terminal location, cut and frame 1 1½ inch openings in the ceiling and the roof to provide the minimum cl ...

  • Napoleon GD82NT-T - page 11

    11 W415-0583 / B / 05.23.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. (Fig.a) 3. Stretch the ...

  • Napoleon GD82NT-T - page 12

    12 W415-0583 / B / 05.23.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws pro- vided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 3. Apply high tempera ...

  • Napoleon GD82NT-T - page 13

    13 W415-0583 / B / 05.23.07 FLUE COLLAR RESTRICTOR PLA TE TOP OF THE FIREBOX Proceed once the vent installation is complete. Note : All gas connections must be contained within the fi replace when complete. 1. The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½” manual shut-off valve, and an 18” ...

  • Napoleon GD82NT-T - page 14

    14 W415-0583 / B / 05.23.07 WARNING F acing and/or fi nishing material must ne ver o verhang into the fi replace opening. Do not distor t or force the fr ame kit components. W hen using a rough fi nish materi- al (i.e.; stone), maintain a ¼” - ½” bor der from the fr aming components. NON-COMBUSTIBLE FINISHING MA TERIAL 59 3 / 8 " 21 3 ...

  • Napoleon GD82NT-T - page 15

    15 W415-0583 / B / 05.23.07 FIGURE 32 MANTLE CLEARANCES 0 34 7 8 9 11 13 12 5 6 7 10 12 H E I G H T M A N T L E MANTLE WIDTH Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fi replace if any part has been under water . Call a qualified service technician IMMED ...

  • Napoleon GD82NT-T - page 16

    16 W415-0583 / B / 05.23.07 Optional Front Glass Door Latches Retainer Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the fi rebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door . Next, pi ...

  • Napoleon GD82NT-T - page 17

    17 W415-0583 / B / 05.23.07 FIGURE 39 TOP EDGES BOTTOM EDGES Next, remove the 6 screws that secure the burner base. Once the gas has been disconnected, the burner train assembly will lift out. TOP SIDE OF ROCK CLUSTER 4. After rocks have been placed on the bowl, add the remaining rock by inserting the pin into the hole shown in Fig 40. FIGURE 40 CU ...

  • Napoleon GD82NT-T - page 18

    18 W415-0583 / B / 05.23.07 BOWL BURNER CURVED DECORA TIVE PA N E L BURNER BOTTOM BURNER BASE S E E - T H R U W I N D O W ELECTRODE BOX (AA Battery Required) CONTROL P ANEL CONTROL P ANEL BA TTER Y REPLACEMENT 1. Remove the optional front. (Instructions on Pg. 17) 2. T ilt the control panel forward allowing access to the electode box which is screw ...

  • Napoleon GD82NT-T - page 19

    19 W415-0583 / B / 05.23.07 Yo u r comes equipped with our Night Light TM . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below . Unplug the wire harness / transformer from the junction box inside the fi replace or turn off the electrical break ...

  • Napoleon GD82NT-T - page 20

    20 W415-0583 / B / 05.23.07 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6. TIMER SETTING The Remote Control has a sleep fu ...

  • Napoleon GD82NT-T - page 21

    21 W415-0583 / B / 05.23.07 CHILD SAFETY LOCK-OUT This function is to deactivate con- trol button. The function is active when the lock icon is lit. T o activate this function press the ON / OFF button and within one second the UP key T o reactivate the remote control buttons follow the same sequence, press ON / OFF key and within one second press ...

  • Napoleon GD82NT-T - page 22

    22 W415-0583 / B / 05.23.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) FIGURE 57 ...

  • Napoleon GD82NT-T - page 23

    23 W415-0583 / B / 05.23.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Use only your hand to turn the gas control ...

  • Napoleon GD82NT-T - page 24

    24 W415-0583 / B / 05.23.07 AIR SHUTTER OPENING Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be e ...

  • Napoleon GD82NT-T - page 25

    25 W415-0583 / B / 05.23.07 CONVERSION KIT This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly , a fi re, explosion or production o ...

  • Napoleon GD82NT-T - page 26

    26 W415-0583 / B / 05.23.07 # P ART NO. DESCRIPTION 1 W135-0275 OUTER ROCKS 2 W135-0304 SINGLE ROCK 3 W135-0277 BOWL 4 GL-655 ROCK SET ASSEMBL Y 5 W565-0090 WIRE MESH 6* W390-0002 DOOR LA TCH ( EA ) 7 W725-0047 NA TURAL GAS V AL VE - MODULA TING 7 W725-0048 PROP ANE GAS V AL VE - MODULA TING 8* W455-0019 NA TURAL GAS ORIFICE #43 8* W455-0003 PROP A ...

  • Napoleon GD82NT-T - page 27

    27 W415-0583 / B / 05.23.07 35 34 16 48 46 45 22 19 28 18 20 AUX ON 0:00 00 ON/OFF FEATURE SELECT 21 25 23 24 26 1 2 17 4 11 9 13 12 10 54 40 41 42 43 55 39 3 5 ...

  • Napoleon GD82NT-T - page 28

    28 W415-0583 / B / 05.23.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked. Carbon is being de- posited on glass, ...

  • Napoleon GD82NT-T - page 29

    29 W415-0583 / B / 05.23.07 Remote wall switch is in “OFF” position; main burner comes on when gas knob is turned to “ON” position. W all switch is mounted upside down - reverse. Faulty valve. - replace. - replace. Remote wall switch is ground- ing. - check for ground (short); repair ground or replace wire. Remote wall switch wire is ground ...

  • Napoleon GD82NT-T - page 30

    30 W415-0583 / B / 05.23.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

  • Napoleon GD82NT-T - page 31

    31 W415-0583 / B / 05.23.07 NOTES ...

Fabricant Napoleon Catégorie Fire Pit

Les documents que nous recevons du fabricant de l'appareilNapoleon GD82NT-T peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Napoleon
- manuels d’utilisations GD82NT-T
- fiches produit Napoleon
- dépliants
- ou étiquettes-énergie Napoleon GD82NT-T
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Napoleon GD82NT-T.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Napoleon GD82NT-T, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Napoleon GD82NT-T. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Napoleon GD82NT-T.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Napoleon GD82NT-T, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Napoleon GD82NT-T par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Napoleon GD82NT-T.

Le manuel d’utilisation complet Napoleon, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Napoleon GD82NT-T - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Napoleon GD82NT-T, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNapoleon GD82NT-T qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Napoleon GD82NT-T - qui devraient nous aider dans les premières étapes lors de l'utilisation Napoleon GD82NT-T
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Napoleon GD82NT-T
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Napoleon GD82NT-T dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Napoleon GD82NT-T?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Napoleon GD82NT-T, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Napoleon GD82NT-T il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)