  • Black Box SW590A-R2 - page 1

    Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com CUSTOMER SUPPORT INFORMATION JUL Y 199 ...

  • Black Box SW590A-R2 - page 2

    FEDERAL COMMUNICA TIONS COMMISSION AND INDUSTR Y CANADA RADIO FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and f ...

  • Black Box SW590A-R2 - page 3

    Chapter Page 1 Specifications .............................................................................................................4 2 Introduction ...............................................................................................................5 3 Installation .................................................................. ...

  • Black Box SW590A-R2 - page 4

    Interface — RS-232 asynchronous (each port individually selectable for DTE or DCE) Connectors — Switch: (5) DB25S female; Switch with Expansion Board: (9) DB25S female Pins Suppor ted — 1-8, 20, 22 Speed — 110 to 19,200 bps (selectable by port) Memor y — 8K buffer Enclosure — Steel Operating T emperature — 32°F to 113°F (0° to 45° ...

  • Black Box SW590A-R2 - page 5

    The Code Operated Switch II (COS II) makes code-operated switching possible for diverse combinations of serial devices. As it switches, the COS II also reconciles differences in word size, speed, flow control, and parity for up to four devices. An Expansion Board, available separately , doubles the maximum number of devices, to eight. Configuration ...

  • Black Box SW590A-R2 - page 6

    3.1. Introduction In addition to this manual, your Switch package should contain one standard switch unit and a wallmounted power supply . After you’ve unpacked the Switch, take a few minutes to look through this manual. Y ou will need a screwdriver large enough to remove the case screws, and a small screwdriver or other edged tool for setting DI ...

  • Black Box SW590A-R2 - page 7

    The board layout for the Four -Port Expansion Board is shown on this page (Fig. 2). If you have ordered one, check your Board to make sure it matches. NOTE: Every time you change the DIP switch settings, you must press the reset button located on the front panel of the switch, or unplug the power supply. The COS-II will not process any data during ...

  • Black Box SW590A-R2 - page 8

    In addition, there are some system characteristics that are set with the eighth DIP switch of the individual port switch banks. Sections 3.6 and 3.7 explain these functions in depth. 3.4 Bank Assignments The individual port switch banks are assigned as follows: Bank Label Port SWA Master Device Port SWB 0 SWC 1 SWD 2 SWE 3 The Four -Port Expansion ...

  • Black Box SW590A-R2 - page 9

    Automatic Timeout The COS II times the inter vals between the reception of each character and the next. Y ou may instruct it to return to an unlinked state after inter vals of 2.5, 5, or 10 minutes, or you may disable this automatic timeout feature. SWF 5 and SWF 6 control this feature. control lead (DTR or CTS) will be dropped to prevent data loss ...

  • Black Box SW590A-R2 - page 10

    3.6.2 S ETTING THE A RMING C HARACTER WITH SWG Switch Bank SWG supplies a portion of the control-code sequence, the sequence that activates the Switch. The arming character , the ASCII code that alerts the COS-II to an upcoming switch action, is set with SWG. The settings are given in the chart below . For a more detailed explanation of control cod ...

  • Black Box SW590A-R2 - page 11

    ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 ’ 27 39 ON ON ON OFF OFF ON OFF OFF ( 28 40 OFF OFF OFF ON OFF ON OFF OFF ) 29 41 ON OFF OFF ON OFF ON OFF OFF * 2A 42 OFF ON OFF ON OFF ON OFF OFF + 2B 43 ON ON OFF ON OFF ON OFF OFF , 2C 44 OFF OFF ON ON OFF ON OFF OFF - 2D 45 ON OFF ON ON OFF ON OFF OFF . 2E 46 OF ...

  • Black Box SW590A-R2 - page 12

    CODE OPERA TED SWITCH II 12 ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 S 53 83 ON ON OFF OFF ON OFF ON OFF T 54 84 OFF OFF ON OFF ON OFF ON OFF U 55 85 ON OFF ON OFF ON OFF ON OFF V 56 86 OFF ON ON OFF ON OFF ON OFF W 57 87 ON ON ON OFF ON OFF ON OFF X 58 88 OFF OFF OFF ON ON OFF ON OFF Y 59 89 ON OFF OFF ON ON ...

  • Black Box SW590A-R2 - page 13

    ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 80 128 OFF OFF OFF OFF OFF OFF OFF ON 81 129 ON OFF OFF OFF OFF OFF OFF ON 82 130 OFF ON OFF OFF OFF OFF OFF ON 83 131 ON ON OFF OFF OFF OFF OFF ON 84 132 OFF OFF ON OFF OFF OFF OFF ON 85 133 ON OFF ON OFF OFF OFF OFF ON 86 134 OFF ON ON OFF OFF OFF OFF ON 87 135 ON ON ...

  • Black Box SW590A-R2 - page 14

    ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 AE 174 OFF ON ON ON OFF ON OFF ON AF 175 ON ON ON ON OFF ON OFF ON B0 176 OFF OFF OFF OFF ON ON OFF ON B1 177 ON OFF OFF OFF ON ON OFF ON B2 178 OFF ON OFF OFF ON ON OFF ON B3 179 ON ON OFF OFF ON ON OFF ON B4 180 OFF OFF ON OFF ON ON OFF ON B5 181 ON OFF ON OFF ON ON ...

  • Black Box SW590A-R2 - page 15

    ARMING CHARACTER SWITCH POSITIONS LSB MSB ASCII CTRL HEX DECIMAL 1 2 3 4 5 6 7 8 DF 223 ON ON ON ON ON OFF ON ON E0 224 OFF OFF OFF OFF OFF ON ON ON E1 225 ON OFF OFF OFF OFF ON ON ON E2 226 OFF ON OFF OFF OFF ON ON ON E3 227 ON ON OFF OFF OFF ON ON ON E4 228 OFF OFF ON OFF OFF ON ON ON E5 229 ON OFF ON OFF OFF ON ON ON E6 230 OFF ON ON OFF OFF ON ...

  • Black Box SW590A-R2 - page 16

    T o Set SWB 8 Pass breaks ON Ignore breaks OFF Lead Pass-Through This function allows the COS II either to pass hardware-handshake leads to connected devices, or to block them. If they are blocked, the leads will still be used to regulate the 8K internal buffer of the Switch. The following table shows the behavior of the COS II for different combin ...

  • Black Box SW590A-R2 - page 17

    3.9. Connecting and Powering Up the COS-II Once you have configured the internal switches and jumpers, you can connect your devices and the wallmounted power jack to the COS-II. Before you begin, you might wish to check the settings of all the DIP switches again, to make sure you have set them correctly . T o prepare the COS-II: 1. Make sure that S ...

  • Black Box SW590A-R2 - page 18

    4.1. Introduction The primary action of the Switch consists of detecting and responding to control-code sequences. As it switches to a particular port, the COS-II establishes a link between the master and the slave device. After the COS-II has switched, it can lock the link out, that is, it can ignore all requests by other ports until the link is b ...

  • Black Box SW590A-R2 - page 19

    4.6. Indicators The front panel of the Switch contains 10 LEDs. The Power LED, at the extreme right, will glow steadily when power is on. The Lockout LED, a green LED at the extreme left, will light when the unit is in lockout. Each of the eight port LEDs, numbered 0 through 7, will respond to the action of the COS II. When the master port is switc ...

  • Black Box SW590A-R2 - page 20

    CODE OPERA TED SWITCH II After you have hit a key , the screen will change to: Serial Por t T est The Serial Port T est is a loopback test that checks whether data is being correctly transmitted and received on any port. The test also checks, using DTR/CTS/RI or R TS/DCD, whether the box can loop back control leads correctly . T o use this test, yo ...

  • Black Box SW590A-R2 - page 21

    Individual Port Switch Bank Settings Switch Position Setting Option 1 2 3 4 5 6 7 Speed 110 bps ON ON ON 300 bps OFF ON ON 600 bps ON OFF ON 1200 bps OFF OFF ON 2400 bps ON ON OFF 4800 bps OFF ON OFF 9600 bps ON OFF OFF 19200 bps OFF OFF OFF Parity none OFF OFF even OFF ON odd ON OFF Word Size 7 bits per word OFF 8 bits per word ON Flow Control Har ...

  • Black Box SW590A-R2 - page 22

    System Switch Options A vailable through Position 8 Switch Option SWA 8 SWB 8 SWC 8 SWD 8 SWE 8 Self-test ON Normal operation OFF Pass breaks ON Ignore breaks OFF Lead pass-through ON Normal operation OFF Graphics Mode Pause In Master Data ON ON Slave Data OFF ON Master or slave data ON OFF Text Mode OFF OFF 22 CODE OPERA TED SWITCH II ...

  • Black Box SW590A-R2 - page 23

    1000 P ark Drive • Lawrence, P A 15055-1018 • 724-746-5500 • F ax 724-746-0746 ©Copyright 1999. Black Box Corporation. All rights reserved. ...

Fabricant Black Box Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilBlack Box SW590A-R2 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Black Box
- manuels d’utilisations SW590A-R2
- fiches produit Black Box
- dépliants
- ou étiquettes-énergie Black Box SW590A-R2
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Black Box SW590A-R2.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Black Box SW590A-R2, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Black Box SW590A-R2. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Black Box SW590A-R2.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Black Box SW590A-R2, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Black Box SW590A-R2 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Black Box SW590A-R2.

Le manuel d’utilisation complet Black Box, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Black Box SW590A-R2 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Black Box SW590A-R2, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBlack Box SW590A-R2 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Black Box SW590A-R2 - qui devraient nous aider dans les premières étapes lors de l'utilisation Black Box SW590A-R2
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Black Box SW590A-R2
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Black Box SW590A-R2 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Black Box SW590A-R2?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Black Box SW590A-R2, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Black Box SW590A-R2 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)