    61225101L1-5B 1 Express 6530 SHDSL NxNTU Installation and Maintenance Section 61225101L1-5B Issue 2, December 2002 CONTENTS 1. GENERAL ..................................................................... 1 2. CONNECTIONS ........................................................... 4 3. OPTIONING ..................................................... ...

  • ADTRAN SHDSL NxNTU - page 2

    2 61225101L1-5B The Express 6530 can be powered from any AC power source ranging from 90 V to 240 V at frequencies of 50 Hz to 60 Hz, or a nominal -48 VDC power source. The SHDSL NTU will be used to provide access to customer premises to E1 or Nx64k leased-line services, as well as primary-rate ISDN. The SHDSL NTU is required to support leased-line ...

  • ADTRAN SHDSL NxNTU - page 3

    61225101L1-5B 3 The Express 6530 has four front panel pushbuttons. The buttons are protected from accidental operation. The front panel button functions can be disabled via the management interface. It is possible to disable the port select SHDSL option to avoid the possibility of looping the SHDSL port when disabled. Table 2 lists and describes th ...

  • ADTRAN SHDSL NxNTU - page 4

    4 61225101L1-5B 2. CONNECTIONS Back Panel Features The back panel of the Express 6530 SHDSL NxNTU is illustrated in Figure 3 . The SHDSL port uses a RJ-45 connector with the interchange circuits and pinouts listed in Table 3 . Table 3. SHDSL Pin Connections e m a N e g n a h c r e t n In o i t p i r c s e Dt u o n i P C / Nn o i t c e n n o C o N3 ...

  • ADTRAN SHDSL NxNTU - page 5

    61225101L1-5B 5 The local management port is a DB-9 female connector and is labeled V.28. The interchange circuits and pinouts are listed in Table 5 . The local management baud rate will auto-detect between 2400 baud and 57600 baud. See EIA-574, Sec 2.2 and Figure 2.7, with Receive Data, Transmit Data and Signal Ground only. The other pins are inte ...

  • ADTRAN SHDSL NxNTU - page 6

    6 61225101L1-5B Table 7 defines the V.35 port pin connections. Table 8 defines the V.36 port pin connections. r e b m u N t i u c r i Ce m a N t i u c r i CE C D m o r F / o T) B / A ( t u o n i P 2 0 1d n u o r G l a n g i SB 3 - 2 0 1a t a D t i m s n a r TO TS / P 4 0 1a t a D e v i e c e RM O R FT / R 5 0 1d n e S o t t s e u q e RO TC 6 0 1d n ...

  • ADTRAN SHDSL NxNTU - page 7

    61225101L1-5B 7 3. OPTIONING Hardware Optioning The strap map for the Express 6530 SHDSL NxNTU is illustrated in Figure 4 . Figure 4. Express 6530 Strap Map ...

  • ADTRAN SHDSL NxNTU - page 8

    8 61225101L1-5B Figure 5. Express 6530 Menu Tree Software Optioning The menu tree in Figure 5 illustrates the path to every provisioning, performance monitoring, and test access point in the Express 6530 menu system. 1. Unit Information Main Menu 2. Provisioning 2. L T 1. NT 1. PN127 2. V .54 2. Disable 1. Enable 1. -15. Threshold in dB 0. Disabled ...

  • ADTRAN SHDSL NxNTU - page 9

    61225101L1-5B 9 Cross-Connect Map The purpose of the cross-connect map is to allocate the time slots (TS0s) from the SHDSL loop to user ports (E1, V.35/X.21) and configure framing. The cross-connect maps can be accessed via the VT100 terminal screens. Select “1,” Provisioning , from the Main Menu. Choose to provision the local unit (Selection 1 ...

  • ADTRAN SHDSL NxNTU - page 10

    10 61225101L1-5B G. Full G.703 Service If this quick key command is selected, the cross- connect map will automatically configure the time slots for Full G.703 service, and the framing will be set for transparent. Refer to the Typical Applications subsection for more information. N. Full Nx64k Service If this quick key command is selected, the cros ...

  • ADTRAN SHDSL NxNTU - page 11

    61225101L1-5B 11 Typical Applications Framed Full E1 Service is set up using the quick key “G,” and then selecting “A” to save the changes. The screen in Figure 8 illustrates a cross-connect map configured for Framed Full E1 Service. Unframed Full E1 Service is set up using the quick key “G,” entering “1” in both the SHDSL TS0 slot ...

  • ADTRAN SHDSL NxNTU - page 12

    12 61225101L1-5B Full Nx64k 2 Mbps Service is set up using the quick key “N,” and then selecting “A” to save the changes. The screen in Figure 10 illustrates a cross-connect map configured for Full Nx64k 2 Mbps Service. In addition, when setting up Full Nx64k 2 Mbps Service, the type of line interface must be specified. V.35, V.36, or X.21 ...

  • ADTRAN SHDSL NxNTU - page 13

    61225101L1-5B 13 Bit Error Rate Test The SHDSL NTU contains a built-in Bit Error Rate Test (BERT). The BERT involves injecting and detecting a Pseudorandom Binary Sequence (PRBS) toward the network on the selected payload (i.e. G.703, Nx64, or entire SHDSL payload). The PRBS used in the SHDSL NTU is PRS15 as defined in ITU-T O.150 and O.151. It is ...

  • ADTRAN SHDSL NxNTU - page 14

    14 61225101L1-5B Local Customer Transparent Loopback – Provides a loopback at the NTU in the customer direction ( Figure 14 ). Data is passed transparently to the network side. Local Network Transparent Loopback – Provides a loopback at the NTU in the network direction ( Figure 18 ). Data is passed transparently to the customer side. Figure 14. ...

  • ADTRAN SHDSL NxNTU - page 15

    61225101L1-5B 15 Loopbacks may be initiated via the VT100 test screens, front panel pushbuttons, Nx64K port control leads, or by receiving V.54 or PN127 in-band looping signals. Not all loopback types are available for all ports and port services by all initiating sources. See Table 9 for an overview. A key to the symbols displayed in Table 9 is av ...

  • ADTRAN SHDSL NxNTU - page 16

    16 61225101L1-5B Multiple Services The NTU supports the configuration of multiple services. These services are routed to either the G.703/G.704 interface or the Nx64k interface. The Nx64k interface supports a single service with 1 <= N <= 36. The G.703 interface (with G.704 framing) supports multiple services (often termed “Stacked E1”). ...

  • ADTRAN SHDSL NxNTU - page 17

    61225101L1-5B 17 The NTU provides framing on the E1 port as described in G.704 (sections 2.3 and 5) and G.706 (section 4) and G.736. In this mode, the data arriving at the SHDSL interface need not contain any G.704 framing and the NTU generates the framing. One or more services can be routed into time slots 1-31. CRC-4 multiframe may be enabled or ...

  • ADTRAN SHDSL NxNTU - page 18

    18 61225101L1-5B 4. SPECIFICATIONS Table 10 lists the specifications for the Express 6530 SHDSL NxNTU. Network Interface Line Rate:. ............................................................ SHDSL per ITU G.991.2 Line Code: ............................................................ TC PAM Connector: ............................................ ...

  • ADTRAN SHDSL NxNTU - page 19

    61225101L1-5B 19 5. WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. USA and Canadian customers can also receive a copy of the warranty via ADTRAN’s toll free ...

  • ADTRAN SHDSL NxNTU - page 20

    20 61225101L1-5B ...

Fabricant ADTRAN Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilADTRAN SHDSL NxNTU peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques ADTRAN
- manuels d’utilisations SHDSL NxNTU
- fiches produit ADTRAN
- dépliants
- ou étiquettes-énergie ADTRAN SHDSL NxNTU
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation ADTRAN SHDSL NxNTU.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation ADTRAN SHDSL NxNTU, manuels d’entretien, brefs manuels ou manuels de l’utilisateur ADTRAN SHDSL NxNTU. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit ADTRAN SHDSL NxNTU.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil ADTRAN SHDSL NxNTU, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser ADTRAN SHDSL NxNTU par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs ADTRAN SHDSL NxNTU.

Le manuel d’utilisation complet ADTRAN, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel ADTRAN SHDSL NxNTU - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières ADTRAN SHDSL NxNTU, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lADTRAN SHDSL NxNTU qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil ADTRAN SHDSL NxNTU - qui devraient nous aider dans les premières étapes lors de l'utilisation ADTRAN SHDSL NxNTU
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de ADTRAN SHDSL NxNTU
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service ADTRAN SHDSL NxNTU dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de ADTRAN SHDSL NxNTU?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec ADTRAN SHDSL NxNTU, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec ADTRAN SHDSL NxNTU il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)