Manuel d’utilisation Drolet 36C03U TYPE 139

21 pages 0.19 mb
Télécharger

Aller à la page of 21

Summary
  • Drolet 36C03U TYPE 139 - page 1

    ULTRA FLAME FIREPLACE GAS INSERT INSTALLATION AND OPERATING INSTRUCTIONS FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY IF YOU SMELL GAS : 1. OPEN WINDOWS 2. TURN OFF MAIN GAS SUPPLY 3. DON’T TOUCH ELECTRICAL SWITCHES 4. EXTINGUISH ANY OPEN FLAME 5 ...

  • Drolet 36C03U TYPE 139 - page 2

    TABLE OF CONTENTS : GENERAL INFORMATION :............................................................................. 2 WARNING :........................................................................................................ 3 SPECIFICATIONS :............................................................................................ 4 TO ...

  • Drolet 36C03U TYPE 139 - page 3

    GENERAL INFORMATION : The ULTRA FLAME is a high efficiency firepl ace gas insert with an input rating of 30 000 Btu/h with natural gas and 26 000 Btu/h with propane. It features a millivolt valve with a constant pilot. This lets you choose between a wall mounted switch, a wireless remote control to turn on or off the main flam e at will. This also ...

  • Drolet 36C03U TYPE 139 - page 4

    WARNING * INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. * DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THE GAS INSERT. * HOT WHEN IN OPERATION. KEEP, FURNITURE, CLOTHING AND FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE. * ADVISE ADULTS AND CHILDREN TO THE HAZARD OF HIGH SURFACE TEMPERATURES AND THAT THEY S HOULD STAY AWAY TO AVOID BURNS OR CLOTH ...

  • Drolet 36C03U TYPE 139 - page 5

    SPECIFICATIONS : Dimensions : height : 20” width : 28” depth : 15” face plate : 44 5/16” x 27 1/2” glass : 14 1/2 x 30 5/16 1400 ° F clear ceramic F u e l : N a t u r a l G a s P r o p a n e Input : 30 000 26 000 Btu/h Manifold pressure : 3.5 11 in w.c. Min inlet pressure : 5 11 in w.c. Max inlet pressure : 7 14 in w.c. Vent size : 4” ...

  • Drolet 36C03U TYPE 139 - page 6

    TOP, SIDE AND FRONT VIEWS : 5 ...

  • Drolet 36C03U TYPE 139 - page 7

    INSTALLATION : 1. When the masonry fireplace that will r eceive the ULTRA FLAME gas insert is thoroughly cold, remove all ashes and vacuum clean. 2. Remove the glass front from the gas insert following page 11 instructions. 3. Remove the burner and firebox bottom plate from the gas insert following page 12 instructions. 4. Remove the draft hood fro ...

  • Drolet 36C03U TYPE 139 - page 8

    11. Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws. 12. Push the ULTRA FLAME back in the fireplace while pulling the draft hood in place. To do so, fix two ropes to the dr aft hood sliders. Make sure the draft hood front lip is squeezed under the steel angl e to prevent any motion. The probe tube must g ...

  • Drolet 36C03U TYPE 139 - page 9

    13. Install a 1/8” NPT plugged tapping for test gauge connection immediately upstream of the gas supply connection to the appliance. 14. Install a shutoff valve to the gas line. Tighten securely using a pipe joint compound. 15. Install a 3/8” flex connector to connect the shutoff valve to the gas valve on the fireplace. Tighten securely using a ...

  • Drolet 36C03U TYPE 139 - page 10

    - Install the wall switch in a convenient location. Route a proper sized wire from the switch or the thermostat to the gas valve. Distance between valve Wire gage and switch 8 ’ 2 2 1 2 ’ 2 0 2 0 ’ 1 8 3 2 ’ 1 6 5 0 ’ 1 4 - Connect the wires in serial with the face plate flame switch ( green wires ). NOTE : DO NOT CONNECT THE WALL SWITCH ...

  • Drolet 36C03U TYPE 139 - page 11

    20. Install the firebox bottom plate and burner following page 12 instructions. 21. Install the 4 logs on the burner as shown on page 13. 22. If so desired, install the embers kits as shown on page 16. 23. Install the glass front following page 11 instructions. 24. Install the face plate according to page 14 instructions. 25. Install a cap on the l ...

  • Drolet 36C03U TYPE 139 - page 12

    GLASS FRONT REMOVAL CLEANING AND INSTALLATION : * To remove the glass front, unscrew the six screws holding it in place as shown. CAUTION : Hold the glass while unscrewing to prevent it from falling. * Clean the glass only with liquid cleaners or soaps and water, do not use abrasive cleaners which could remove the coating on the glass. WARNING : Do ...

  • Drolet 36C03U TYPE 139 - page 13

    BURNER REMOVAL AND INSTALLATION : REMOVAL : 1. Slide the burner to the left and pull toward you. 2. To gain access to the fan, also remove the firebox bottom plate. INSTALLATION : 1. Put the bottom plate back in place. 2. Put the burner assembly back in the firebox and push to the right until it touches the firebox side. Make sure the main orif ice ...

  • Drolet 36C03U TYPE 139 - page 14

    LOG INSTALLATION : 1. Remove the glass front as described on page 11. 2. Install the longer log in back of the firebox with locating grooves on top. 3. Install the 14” log in the front of the fire box and to the right. Make sure the log is pushed against the metal retainer on the burner face. 4. Place the front of the log with a hole in the secon ...

  • Drolet 36C03U TYPE 139 - page 15

    FACE PLATE ASSEMBLY AND INSTALLATION : ASSEMBLY : 1. Bolt the face plate top piece to the left piece using two #10-24 x 1/2 bolts and nuts (B). 2. Place both louver assemblies in position with their pivot rod inserted through the face plate side pieces holes (C). Th e top and bottom louvers are clearly identified. WARNING : Do not invert the top an ...

  • Drolet 36C03U TYPE 139 - page 16

    INSTALLATIONS : 1. Screw the air deflector on the unit as shown using three #10 x 1/2 metal screws. 2. Bring the face plate in position on the gas insert taking care to slip the air deflector between the top louver and the bottom of the top piece. Secure using four #10 x 1/2 metal screws (D). 3. Connect the slip on the terminals on the rocker switc ...

  • Drolet 36C03U TYPE 139 - page 17

    REFRACTORY PANELS INSTALLATIONS : 1. Remove the front glass as described on page 11. 2. Remove the logs from the firebox. 3. Install the two sides refractory panels a nd pull them forward as mush as possible to help insertion of the back panel. 4. Place the back refractory against the back of the firebox. 5. Push the side refractory against the bac ...

  • Drolet 36C03U TYPE 139 - page 18

    OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS : 1. Open the bottom louvers of the face plate to reach the control. 2. Turn the gas valve knob to the “OFF” position and wait 5 minutes. Note : You have to depress the gas valve knob to turn from “PILOT” to “OFF” or from “OFF” to “PILOT”. 3. Turn the gas valve knob to “PILOT”. 4. ...

  • Drolet 36C03U TYPE 139 - page 19

    MAINTENANCE INSTRUCTIONS : TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. * The venting system and the gas insert should be inspected at least once a year. * Remove the glass front and the logs clean them if necessary. * The control compartment, air circulating passages, firebox, logs and burner sh ...

  • Drolet 36C03U TYPE 139 - page 20

    OPTIONAL PARTS ITEM DESCRIPTION Part No QTY Face plate, silver gray enamel E5422 1 Face plate, black enamel E5420 1 Face plate, gold E5415 1 Face plate, charcoal painted E5416 1 Face plate, black painted E5418 1 Wall switch E5978 1 Remote control E5568 1 Decorative refractory kit E5988 1 REPLACEMENT PARTS ITEM DESCRIPTION Part No QTY Log kit 2232 1 ...

  • Drolet 36C03U TYPE 139 - page 21

    ____________________________ LIMITED 5 YEARS WARRANTY ____________________________ DROLET STOVES AND FIREPLACES INC. here by warrants the quality of its fireplace gas insert against manufacturing defects. Th e product shall be delivered to the buyer in good condition and the latter should inform the vendor im mediately of any defect in the product ...

Fabricant Drolet Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilDrolet 36C03U TYPE 139 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Drolet
- manuels d’utilisations 36C03U TYPE 139
- fiches produit Drolet
- dépliants
- ou étiquettes-énergie Drolet 36C03U TYPE 139
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Drolet 36C03U TYPE 139.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Drolet 36C03U TYPE 139, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Drolet 36C03U TYPE 139. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Drolet 36C03U TYPE 139.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Drolet 36C03U TYPE 139, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Drolet 36C03U TYPE 139 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Drolet 36C03U TYPE 139.

Le manuel d’utilisation complet Drolet, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Drolet 36C03U TYPE 139 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Drolet 36C03U TYPE 139, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDrolet 36C03U TYPE 139 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Drolet 36C03U TYPE 139 - qui devraient nous aider dans les premières étapes lors de l'utilisation Drolet 36C03U TYPE 139
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Drolet 36C03U TYPE 139
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Drolet 36C03U TYPE 139 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Drolet 36C03U TYPE 139?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Drolet 36C03U TYPE 139, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Drolet 36C03U TYPE 139 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)