Manuel d’utilisation Superior CFST-CMP

24 pages 0.59 mb
Télécharger

Aller à la page of 24

Summary
  • Superior CFST-CMP - page 1

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 903589 REV. E 02/2004 CFST -CMN CFPF-CMN CFST -CMP CFPF-CMP MODELS ST ANDARD SERIES INST ALLA TION INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS. DO NOT BUILD A WOOD FIRE. FOR YOUR SAFETY: Do not store or use gasoline or other flammable v ...

  • Superior CFST-CMP - page 2

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 GENERAL INFORMATION The CFST and CFPF Series Unvented Room Heaters covered in this manual feature ceramic fiber split logs which glow realistically when the heater is operating. These heaters have a standing pilot and are manually controlled through the use of a milli- volt gas valve. A spark igniti ...

  • Superior CFST-CMP - page 3

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN- STRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING UNVENTED ROOM HEATER, VOIDING ITS WAR- RANTY. ANY CHANGE TO THIS HEATER AND/OR ITS OPERATING CONTROLS IS DANGEROUS. IMPROPER INSTALLA- TION O ...

  • Superior CFST-CMP - page 4

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Example: CFST/PF heater 34,000 BTU/Hr Gas appliance #1 32,000 BTU/Hr (water heater) Total = 66,000 BTU/Hr * Do not include direct-vent gas appliances. Direct-vent is sealed combustion and draws combustion air from the outdoors. 4 . Compare the maximum BTU/Hr the space can support with the actual amo ...

  • Superior CFST-CMP - page 5

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 41 ⁵⁄₈ ” (1210 mm) Figure 1 A hearth extension is not required with this appliance. If a hearth extension is used, do not block the lower control compartment door. Any ...

  • Superior CFST-CMP - page 6

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 CFST FRAMING SPECIFICATIONS CFST APPLIANCE SPECIFICATIONS A 22 ³⁄₄ " (578 mm)* B 43" (1092 mm) Min. C 43" (1092 mm) Min. Framing Dimensions Figure 3 Figure 4 Figure 5 C A B Gas Line 2 x 4 Wall Framing T op View * ¹⁄₂ " (13mm) Required Air Space Clearance Drywall * Gas L ...

  • Superior CFST-CMP - page 7

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 6 Figure 7 Figure 8 C A B Gas Line CFPF FRAMING SPECIFICATIONS CFPF APPLIANCE SPECIFICATIONS Gas Line Energy Wall 2 x 4 Outside Wall Drywall Dr ywall * Bracket Bracket Framing T op View * ¹⁄₂ " (13mm) Required Air Space Clearance A 22 ³⁄₄ " (578 mm)* B 40 ¹⁄₈ " ( ...

  • Superior CFST-CMP - page 8

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Step 2 . Route a ¹⁄₂ " (13 mm) gas line along the left or right side framing ( Figure 9 ). All appliances have a 3" long ³⁄₈ " NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV. Figure 11 The gas con ...

  • Superior CFST-CMP - page 9

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Step 7. Installing the Optional Remote Wall Switch – The standard millivolt system comes from the factory wired as shown in Figure 12 . Select a convenient location for the remote wall switch and connect the wiring to the appliance ( Figure 13 ). CAUTION: DO NOT CONNECT THE OPTIONAL REMOTE SWITCH ...

  • Superior CFST-CMP - page 10

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Assembling the Logs WARNING: DO NOT ADD EXTRA LOGS OR ORNAMENTS SUCH AS PINE CONES, VERMICULITE OR ROCK WOOL. USING THESE ADDED ITEMS CAN CAUSE SOOTING. Figure 15 Step 9. The heater includes a set of ceramic fiber logs. The logs are assembled as shown in Figure 15 . Handle these logs with great car ...

  • Superior CFST-CMP - page 11

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 The installation of the logs and twigs, should be complete and resemble Figures 15, 16 and 19 . After setting the logs and rockwool into posi- tion as described above, ensure the logs are properly and firmly situated. The heater will not function as intended if the logs are not correctly positioned ...

  • Superior CFST-CMP - page 12

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face. Tarnishing of these pieces is normal, unavoidable and should be expected. Forced Air Kit The F ...

  • Superior CFST-CMP - page 13

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 Gas Flex Line with Valve A gas flex line kit is available to aid in attaching the appliance to the gas supply. This kit can only be used where local codes permit. The kit includes a ¹⁄₂ " NPT to ³⁄₈ " flare in line shut-off valve, a 12" flex line ³⁄₈ " female flar ...

  • Superior CFST-CMP - page 14

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Remote Control Kit RCK Rocker Switch Kit RS Wall Switch Kit WSK Gas Flex Line Kit GFLV Decorative Volcanic Stone DVS 4-Piece Decorative Arch Frame Kit -Main Panel DAT-6-4 -End Panel DAET-6-4 1-Piece Decorative Arch Frame Kit -Main Panel DAT-6-1 -En ...

  • Superior CFST-CMP - page 15

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open. 3. Locate gas control knob and piezo. 4. Depress control knob in and turn clockwise to the “OFF” position ( Figure 23 ) ...

  • Superior CFST-CMP - page 16

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force. Figure 23 Pilot Location Figure 24 Figure 25 Turn Control Knob to “OFF” Position Turn Control Knob to “PILOT” Position EA TPTH TP TH P I L O T H I L O W P I L O T O N it O F F EA T ...

  • Superior CFST-CMP - page 17

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 CFST REPLACEMENT PARTS LIST CFST GAS CONTROLS — MILLIVOLT CFST-CMN CFST-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123071 1 123072 1 2. Bar, Louver (Black) 104951 8 104951 8 3. Hood (Black), Clean Face 108971 2 108971 2 4. Screw 000861 6 000861 6 5. Replacement Glas ...

  • Superior CFST-CMP - page 18

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS – CFST 8 20 9 21 22 23 a. b. c. d. f. g. e. 3 2 1 7 6 2 11 4 5 10 ...

  • Superior CFST-CMP - page 19

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 CFPF REPLACEMENT PARTS LIST CFPF GAS CONTROLS — MILLIVOLT CFPF-CMN CFPF-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123073 1 123074 1 2. Bar, Louver (Black) - Main Panel 104951 8 104951 8 3. Bar, Louver (Black) - End Panel 104955 4 104955 4 4. Hood (Black), Clean Fac ...

  • Superior CFST-CMP - page 20

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 REPLACEMENT PARTS – CFPF 11 20 12 21 22 23 13 4 2 1 10 14 7 6 2 5 3 3 9 a. b. c. d. e. 8 f. g. ...

  • Superior CFST-CMP - page 21

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 21 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position. 5. When igniter button is pressed, there is spark at ODS/pilot, but no ignition. 6. ODS/pilot ...

  • Superior CFST-CMP - page 22

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 22 ...

  • Superior CFST-CMP - page 23

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 23 ...

  • Superior CFST-CMP - page 24

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 24 Printed in U.S.A. © 1997 by SFC P/N 903589 REV. E 02/2004 Catalytic Gas Fireplace Manufacturer's Limited W arranty 10 Y ears THE WARRANTY The manufacturer warrants the components of this Catalytic Gas Fireplace manufactured by SFC, INC. (hereinafter, SFC) to be free from defects in materials ...

Fabricant Superior Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilSuperior CFST-CMP peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Superior
- manuels d’utilisations CFST-CMP
- fiches produit Superior
- dépliants
- ou étiquettes-énergie Superior CFST-CMP
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Superior CFST-CMP.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Superior CFST-CMP, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Superior CFST-CMP. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Superior CFST-CMP.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Superior CFST-CMP, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Superior CFST-CMP par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Superior CFST-CMP.

Le manuel d’utilisation complet Superior, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Superior CFST-CMP - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Superior CFST-CMP, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSuperior CFST-CMP qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Superior CFST-CMP - qui devraient nous aider dans les premières étapes lors de l'utilisation Superior CFST-CMP
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Superior CFST-CMP
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Superior CFST-CMP dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Superior CFST-CMP?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Superior CFST-CMP, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Superior CFST-CMP il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)