Manuel d’utilisation Omron BP652

30 pages Non applicable
Télécharger

Aller à la page of 30

Summary
  • Omron BP652 - page 1

    ESP AÑOL ENGLISH 7 series A utomatic W rist Blood Pr essure Monitor Model BP652 INSTRUCTION MANU AL ...

  • Omron BP652 - page 2

    2 TABLE OF CONTENTS Before using the Monitor Introduction ......................................................................................................... 3 Safety Information ................................................................................................ 4 Operating the Device ............................................. ...

  • Omron BP652 - page 3

    3 INTRODUCTION Thank you for purchasing the OMRON ® BP652 IntelliSense ® Automatic W rist Blood Pressure Monitor . The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for people who frequently monitor their own blood pressure. Y our new digital blood pressure monitor uses the oscillometric method of blood pres- sur ...

  • Omron BP652 - page 4

    4 SAFETY INFORMA TION T o assure the corr ect use of the product, basic safety measur es should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . ...

  • Omron BP652 - page 5

    5 SAFETY INFORMA TION Do not use a cellular phone near the device. It may result in an operational failure. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.  Useonly1.5V “AAA”alkalinebatterieswiththisdevice.Donotuseothert ...

  • Omron BP652 - page 6

    6 BEFORE T AKING A MEASUREMENT T o ensure a reliable reading follow these recommendations: 1. A void eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. A void taking measurements during stressful times. 3. ...

  • Omron BP652 - page 7

    7 KNOW Y OUR UNIT Main Unit: Components: 2 “ AAA ” Alkaline Batteries Instruction Manual Quick Start Guide Date/Time setting ( ) button Display Wrist cuff Memory (MEM) button ST ART/STOP butt on User ID selection switch SET button Battery compar tment Date/Time setting ( ) button INTRODUCTION Thank you for purchasing the OMRON ® BP652 IntelliS ...

  • Omron BP652 - page 8

    8 UNIT DISPLA Y Positioning indicat or Diastolic blood pressure Irregular heartbeat symbol Memory symbol (Displayed when viewing values stored in memory) A verage v alue symbol (Refer to “Using the Memory Function” .) Movement error symbol (Displayed if you mo ve your body during the measurement) User ID symbol (A or B) (If “ GUEST ” is sel ...

  • Omron BP652 - page 9

    9 DISPLA Y SYMBOLS IRREGULAR HEAR TBEA T SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. Anirregularheartbeatrhythmisdenedasa rhythm that varies by less than 25% from the average rhy ...

  • Omron BP652 - page 10

    10 This is a general guideline because blood pressure depends on age and morbidity . A lower home blood pressure goal may be recommended for certain patients, including diabetic patients, pregnant women, and patients with renal failure. WARNING Contact your physicianfor specicinformation aboutyour blood pressure. Se ...

  • Omron BP652 - page 11

    11 BA T TERY INST ALLA TION CAUTION Useonly1.5V“AAA”alkalinebatterieswiththisdevice. 1. Press the hook on the bottom of the battery cover and lift the cover off in the direction of the arrow . 2. Install2“AAA”sizebatteriessothe+(positive)and- (negative) polarities match the polarit ...

  • Omron BP652 - page 12

    12 BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display , turn the monitor off and remove all the batteries. Replace with 2 new batteries at the same time. Long-life alkaline batteries are recommended. WARNING Ifbatteryuidshouldgetinyoureyes,immediatelyrinsewith plenty of c ...

  • Omron BP652 - page 13

    13 SET TING THE DA TE AND TIME Setthemonitortothecurrentdateandtimebeforetakingameasurementfortherst time. 1. TO ST ART THE SETTING Press the Date/T ime Setting button ( ) to adjust the date and time. Theyearashesonthedisplay . 2. SETTING THE YEAR Press the Date/T ime Setting butt ...

  • Omron BP652 - page 14

    14 4. SETTING THE DA Y Press the Date/T ime Setting button ( ) to advance by increments of one day . Press the Date/T ime Setting button ( ) to set the current day . Thehourashesonthedisplay . 5. SETTING THE HOUR The time is set using AM or PM. Press the Date/T ime Setting button ( ) to advance by increments of one hour . Press th ...

  • Omron BP652 - page 15

    15 SET TING THE ADV ANCED POSITIONING SENSOR (APS) Y ou can change the options for various settings on your monitor . Pressing the SET button to change a setting. Press the MEM button to select the options for that setting. Afterselectingasetting,presstheST ART/ST OPbuttontoconrmthesettingandturn the pow ...

  • Omron BP652 - page 16

    16 SETTING FOR RIGHT OR LEFT WRIST MEASUREMENT 1. While in the setting mode, press the SET button until the wrist symbol ( or ) appears on the display . NOTES: •Thedefaultsettingis“ ”. •Afteryouchoose“oFF”forthe Positioning indicator , the monitor skips this process. 2. Press the MEM button to sele ...

  • Omron BP652 - page 17

    17 IfthePositioningindicatoris“on1”or“on2”: on1: The buzzer sounds only when the monitor is in proper position. on2: The buzzer sounds a series of two short blips if your wrist is too far away from the measuring position, and beeps when your wrist is in the proper position. oFF: The buzzer will not sound. IfthePos ...

  • Omron BP652 - page 18

    18 CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. APPL YING THE CUFF ON THE LEFT W ...

  • Omron BP652 - page 19

    19 5. Fold the remaining part of the wrist cuff back out of the way . APPL YING THE CUFF ON THE RIGHT WRIST When taking a measurement using the right wrist position the cuff as shown in the illustration. Referto“SettingforRightorLeftW ristforMeasurement”. APPL YING THE WRIST CUFF ...

  • Omron BP652 - page 20

    20 The monitor is designed to take measurements and store the measurement values in memory for two people using USER ID A and USER ID B. The monitor can be used to takeasinglemeasurementusingtheGUESTmodearenotstoredinthememory . 1. Sitcomfortablyinachairwithyourfeetatonthe? ...

  • Omron BP652 - page 21

    21 T AKING A MEASUREMENT 5. Press the ST AR T/STOP button. All symbols appear on the display . Thecuffstartstoinateautomatically . Asthecuffinates,themonitorautomaticallydeterminesyouridealinationlevel. Thismonitordetectsyourbloodpressureandpulserateduringin? ...

  • Omron BP652 - page 22

    22 USING THE MEMOR Y FUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate for each user (A and B) in the memory . The monitor automatically stores up to 100 sets of measurement values (blood pressure and pulse rate) for each user (A and B). When 100 sets of measurement values are stored, the oldest rec ...

  • Omron BP652 - page 23

    23 USING THE MEMOR Y FUNCTION NOTES: • Thedateandtimearealternatelydisplayedwiththemeasurement values. •PresstheMEMbuttonrepeatedlytodisplaythenextvalues. •PressandholdtheMEMbuttontodisplaythevaluesfaster . 3. Press the ST AR T/STOP button to ...

  • Omron BP652 - page 24

    24 CARE AND MAINTENANCE T o keep your digital blood pressur e monitor in the best condition and protect the unit fr om damage, follow the directions listed below: Do not forcefully bend the cuf f. Do not fold tightly . Clean the monitor with a soft dry cloth. Do not use any abrasive or volatile cleaners. Do not attempt to clean the cuff. CAUTION Do ...

  • Omron BP652 - page 25

    25 ERROR INDICA TORS SYMBOL CAUSE CORRECTION Monitor could not detect pulse wave. T ake another measurement and remain still until the measurement is complete. Cuffunder -inated. Cuff not applied correctly . Remove the monitor from your wrist. Read“T akingaMeasurement”. W ait 2-3 minutes. T ake another measurement. Cuffover -i ...

  • Omron BP652 - page 26

    26 TROUBLESHOO TING TIPS PROBLEM CAUSES AND SOLUTIONS No power . No display appears on the unit. Replace both batteries with new ones at the same time. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low . Blood pressure varies constantly . Many factors including stress, time ...

  • Omron BP652 - page 27

    27 FC C ST A TEMENT Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The produc ...

  • Omron BP652 - page 28

    28 Y our BP652 IntelliSense ® Automatic W rist Blood Pressure Monitor, excluding the wrist cuff and batteries, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor . The above warranties extend only to the origin ...

  • Omron BP652 - page 29

    29 SPECIFICA TIONS Model: BP652 (HEM-6052-Z) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valve Rapid Air Release: Automatic exhaust valve Mea ...

  • Omron BP652 - page 30

    Omron Healthcar e, Inc. 1200 Lakeside Drive Bannockburn, IL 60015 www .omronhealthcare.com Copyright © 2010 Omron Healthcare, Inc. Made in China 5329415-9A ...

Fabricant Omron Catégorie Sphygmomanometer

Les documents que nous recevons du fabricant de l'appareilOmron BP652 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omron
- manuels d’utilisations BP652
- fiches produit Omron
- dépliants
- ou étiquettes-énergie Omron BP652
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omron BP652.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omron BP652, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omron BP652. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omron BP652.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Omron BP652, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omron BP652 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omron BP652.

Le manuel d’utilisation complet Omron, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omron BP652 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omron BP652, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmron BP652 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omron BP652 - qui devraient nous aider dans les premières étapes lors de l'utilisation Omron BP652
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omron BP652
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omron BP652 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omron BP652?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omron BP652, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omron BP652 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)