Manuel d’utilisation Trane TWA075A

56 pages 3.72 mb
Télécharger

Aller à la page of 56

Summary
  • Trane TWA075A - page 1

    Split S yst em Heat Pumps Split S ystem Heat Pumps T W A075A -TW A20 0B Air Handlers T W E050A -T WE20 0B 50 H z SSP -PRC002-EN January 2004 ...

  • Trane TWA075A - page 2

    ©American Standard Inc. 20 0 1 SSP -PRC0 02-EN Intr oduction Split System Heat Pump Units . . . Designed With Y our Needs In Mind. The T rane reputation for quality and reliability in air conditioning continues with the Odyssey™ family of light commercial split systems. T rane paid at tention to your needs to mak e sure you get a system that wil ...

  • Trane TWA075A - page 3

    Contents SSP -PRC0 02-EN 2 4 6 7 8 9 12 12 24 31 33 39 52 Intr oduction F eat ur es and Benefits Application Consider ations Selection Pr ocedur e Model Number Description Gener al D ata P erfor mance Data Cool and Heat P erformance F an P erformance Electr ic P o wer Connection and Wir ing Dimension and W eights Mec hanical Specifications 3 ...

  • Trane TWA075A - page 4

    4 SSP -PRC0 02-EN F eatures and Benef its Condensing Units Options The TW A075A and 1 0 0A single compressor models feature single refrigeration circuitry , lowering job installation costs by requiring only one set of refrigerant lines. These units are ideal for the low cost, new construction jobs as well as renovation and replacement buildings. In ...

  • Trane TWA075A - page 5

    5 SSP -PRC0 02-EN F eatures and Benef its Odyssey — A Complete Split Syst em Odyssey deliver s the flexibility to select a complete system that meets your par ticular job requirements. Air handlers are designed, tested, and rated with outdoor units to let you select the proper matc h between capacity and load. Heat pumps can also be matc hed with ...

  • Trane TWA075A - page 6

    6 SSP -PRC0 02-EN Application Considerations T ypical Horiz ontal Air Handler Application T ypical V ertical Air Handler Application T ypical Split Syst em Application Lo w Ambient Cooling As manufactured, these units can operate to 50°F (1 0°C) in the cooling mode of operation. An accessory head pressure control will allow operation to 0° F (-1 ...

  • Trane TWA075A - page 7

    7 SSP -PRC0 02-EN S election P rocedure Cooling Capacity St ep 1 — Calculate the building’ s total and sensible cooling loads at design conditions. St ep 2 — Siz e the equipment using T able PD-1 . Matc h the cooling loads at design conditions. Example: The following are the building cooling requirements a Electrical Characteristics: 380-415/ ...

  • Trane TWA075A - page 8

    8 SSP -PRC0 02-EN Model Number Description Digit 8 - Electr ical Charact e r istics D = 380-415/3/50 Digits 9, 1 0 - Fact ory - Installed Options 0 0 = No Options 0S = Blac k Epoxy Coated Coil Digit 1 1 - Minor Design Sequence D = Four th Digit 12- Service Digit A= F i r s t Split Syst em Heat Pump Model Nomenclatur e Digit 7 - Major Development Se ...

  • Trane TWA075A - page 9

    9 SSP -PRC0 02-EN General Data (Heat P umps) T able GD-1 — Gener al Data — Heat Pumps TWA075A TWA100A Cooling Performance 1 Gross Cooling Capacity, Btu (kW) Matched Air Handler, Btu (kW) 85,000 (24.89) 1 12,0 0 0 (32.79) Heat Pump Only 2 , Btu (kW ) 85,000 (24.89) 1 12,00 0 (32.79) ARI Net Cooling Capacity 3 83,000 (24.30) 1 08,00 0 (31 .62) Sy ...

  • Trane TWA075A - page 10

    10 SSP -PRC0 02-EN General Data (Heat P umps) T able GD-2 Gener al D ata — Heat Pumps TWA155B TWA200B Cooling Performance 1 Gross Cooling Capacity, Btu (kW) Matched Air Handler, Btu (kW) 167 ,00 0 (48.9) 218,000 (63.83) Condensing Unit Only 2 , Btu (kW ) 167 ,00 0 (48.9 ) 218,000 (63.83) ARI Net Cooling Capacity 3 162,00 0 (47 .43) 21 1,0 00 (61 ...

  • Trane TWA075A - page 11

    11 SSP -PRC0 02-EN T able GD-3 — Gener al Data — Air Handlers TWE050A TWE075A TWE1 0 0A TWE1 0 0B System Data 1 No. Refrigerant Circuits 1 1 1 2 Suction Line, in. (mm) OD 1 . 120 (28.4) 1 .380 (35.0) 1 .380 (35.0) 1 .380 (35.0) Liquid Line, in. (mm) OD 0.38 (9.7) 0.50 (12.7) 0.50 (12.7) 0.50 (12.7) Indoor Coil — T ype Plate Fin Plate Fin Plat ...

  • Trane TWA075A - page 12

    12 P erformance Data SSP -PRC0 02-EN (S ystem) T able PD-1 — Gross Cooling Capacities (MBh) TW A075A Heat Pump with TWE075A Air Handler (I-P) Ambient T emperature (°F) 85 95 1 0 5 1 15 Enter. D r y Entering W et Bulb (°F) B u l b 6 16 77 3 6 1 6 77 36 16 77 36 16 7 7 3 C F M (°F) T ot al Sens. T ot al Sens. T ot al Sens. T ota l Sens. T ot al ...

  • Trane TWA075A - page 13

    13 P erf ormance Data SSP -PRC0 02-EN (S ystem) T able PD-2 — Gr oss Cooling Capacities (MBh) TW A1 0 0A Heat Pump with TWE1 0 0A Air Handler (I-P) Ambient T emperature (°F) 85 95 1 0 5 1 15 Enter. D r y Entering W et Bulb (°F) B u l b 6 16 77 3 6 1 6 77 36 16 77 36 16 7 7 3 C F M (°F) T ota l Sens. T ota l Sens. T ot al Sens. T ot al Sens. T ...

  • Trane TWA075A - page 14

    14 P erformance Data SSP -PRC0 02-EN (S ystem) T able PD-3 — Gross Cooling Capacities (MBh) TW A155B Heat Pump with TWE155B Air Handler (I-P) Ambient T emperature (°F) 85 95 1 0 5 1 15 Enter. D r y Entering W et Bulb (°F) B u l b 6 16 77 3 6 1 6 77 36 16 77 36 16 7 7 3 C F M (°F) T ota l Sens. T ot al Sens. T ot al Sens. T ot al Sens. T o ta l ...

  • Trane TWA075A - page 15

    15 P erf ormance Data SSP -PRC0 02-EN T able PD-4 — Gr oss Cooling Capacities (MBh) TW A20 0B Heat Pump with TWE200B Air Handler (I-P) Ambient T emperature (°F) 85 95 1 0 5 1 15 Enter. D r y Entering W et Bulb (°F) B u l b 6 16 77 3 6 1 6 77 36 16 77 36 16 7 7 3 C F M (°F) T ota l Sens. T ota l Sens. T ot al Sens. T ot al Sens. T ota l Sens. T ...

  • Trane TWA075A - page 16

    16 P erformance Data SSP -PRC0 02-EN (TW A075A) T able PD-5 — Gr oss Cooling Perf or mance (kW) TW A075A Heat Pump Only (SI) OD T e m p Suction Reference T emperature °C °C -1 .1 1 . 7 4. 4 7 .2 10 12.8 Head pressure (kP A) 1 142 1 180 1220 1262 1305 1350 18.3 Capacity (kW) 21 .2 23.4 25.7 28.1 30.5 33.0 OD Unit P ower (kW) 4.91 5.01 5.13 5.25 ...

  • Trane TWA075A - page 17

    17 P erf ormance Data SSP -PRC0 02-EN (TW A1 0 0A) T able PD-6— Gross Cooling P erformance (MBh) TW A1 00A Heat Pump Only (I-P) OD T e mp Suction Reference T emperature °F ° F 30 35 40 45 50 55 Head press PSIG 1 6 4 16 9 1 7 4 17 9 1 8 5 1 9 1 65 Cap. Btuh/1000 9 9.4 109.5 120.0 130.9 142.2 153.9 OD Un it KW 6.39 6.53 6.67 6.83 6.99 7 .16 Head ...

  • Trane TWA075A - page 18

    18 P erformance Data SSP -PRC0 02-EN (TW A1 55B) T able PD-7 — Gross Cooling P erfor mance (MBh) TW A155B Heat Pump Only (I-P) OD T e m p Suction Reference T emperature °F ° F 30 35 40 45 50 55 Head press PSIG 1 6 5 17 0 1 7 6 18 2 1 8 8 1 9 4 65 Cap. Btuh/1000 142.4 157 .4 173.0 189.2 205.9 222.8 OD U nit KW 9.59 9.80 10.02 10.26 10.52 10.78 H ...

  • Trane TWA075A - page 19

    19 P erf ormance Data SSP -PRC0 02-EN (TW A20 0B) T able PD-8 — Gross Cooling P erformance (MBh) TW A20 0B Heat Pump Only (I-P) OD T e mp Suction Reference T emperature °F ° F 3 03 54 04 55 05 5 Head press PSIG 1 7 3 17 9 1 8 5 1 91 1 9 8 20 5 65 Cap. Btuh/1000 1 96.4 215.5 235.3 255.8 276.9 298.5 OD U nit KW 12.94 13.25 13.58 13.93 14.30 14.69 ...

  • Trane TWA075A - page 20

    20 P erformance Data SSP -PRC0 02-EN (S ystem) Correction Factors - Other Airflows (Table Value x Correction Factor = Value at new airflow) Airf low 2250 cfm 2750 cfm 3822 m 3 /h 4672 m 3 /h Heating Capacity x 0. 99 x 1.0 1 Co m pr e ss o r k W x 1.02 x 0.98 Values at ARI Rating Conditions of: 70F (21.1C) and 47/43F (8.3/6.1C)(High Temp.Cond.) 70F ...

  • Trane TWA075A - page 21

    21 P erf ormance Data SSP -PRC0 02-EN (S ystem) T able PD-1 0 — Gross Heating Capacities (kW) TW A100A Heat Pump with TWE1 0 0A Air Handler At 5649 m 3 /h (SI) Outdoor H e a t i n g C a p a c i t y ( k W ) A t T o t a l Po w e r i n K i l o wa tt s A t T empe ratu re Indicated Indoor Dry Bulb T emperature Indicated Indoor Dry Bulb T emperature (? ...

  • Trane TWA075A - page 22

    22 P erformance Data SSP -PRC0 02-EN (S ystem) T able PD-1 1 — Gross Heating Capacities (MBh) TW A155B Heat Pump with TWE155B Air Handler At 50 0 0 CFM (I-P) Outdoor H e a t i n g Capacity (BTUH/1000) At T o tal Power in Kil owatts At T emper atur e Indicated Indoor Dry Bulb T emperature Indicated Indoor Dry Bulb T emperature ( ° F ) 6 07 07 58 ...

  • Trane TWA075A - page 23

    23 P erf ormance Data SSP -PRC0 02-EN (S ystem) T able PD-12 — Gr oss Heating Capacities (MBh) TW A20 0B Heat Pump with TWE200B Air Handler At 6675 CFM (I-P) Outdoor H e a t i n g Capacity (BTUH/1000) At T otal Power in Kil owatts At T empe ratu re Indicated Indoor Dry Bulb T emperature Indicated Indoor Dry Bulb T emperature ( ° F ) 6 07 07 58 0 ...

  • Trane TWA075A - page 24

    24 P erformance Data SSP -PRC0 02-EN (Air Handler) T able PD-13— Ev aporator F an P erformance — TWE050A (SI) External Static Pressure (Pascal) 25 50 7 5 100 125 150 174 199 224 249 274 m 3 /h r RPM k W RPM k W RPM k W RPM k W RPM k W RPM k W RPM k W RPM k W RPM k W RPM k W RPM k W 2379 ———— 6 4 6 0 . 2 8 6 9 8 0 . 3 1 7 5 1 0 . 3 5 8 0 ...

  • Trane TWA075A - page 25

    25 P erf ormance Data SSP -PRC0 02-EN (Air Handler) T able PD-16 — Blow er Speeds — TWE075A Motor Drive T urns Open D r i v e 6543210 St an da rd N/A 600 650 700 750 800 850 L o w S t a t i c N/A 428 464 499 535 571 606 H i g h S t a t i c N/A 700 750 800 850 900 950 T able PD-15 — Ev aporat or F an P erf ormance TWE075A (I-P) External Static ...

  • Trane TWA075A - page 26

    26 P erformance Data SSP -PRC0 02-EN (Air Handler) T able PD - 18 — Blo wer Speeds — TWE1 0 0A, TWE1 0 0B Motor Sheave T urns Open D r i v e 6543210 S t a n d ar d N /A 587 629 671 713 755 796 L ow S t a ti c N / A 453 485 518 550 583 615 H i g h S t a t i c N/A 606 641 677 713 748 784 H i g h S t a t i c I I N/ A 745 789 833 877 920 965 T able ...

  • Trane TWA075A - page 27

    27 P erf ormance Data SSP -PRC0 02-EN (Air Handler) T able PD-20— Blow er Speeds — TWE155B Motor Sheave T urns Open D r i v e 6543210 St an da rd 61 9 648 677 705 734 763 N/A H i g h S t a t i c 777 806 835 863 892 921 950 T able PD-1 9 — Ev aporat or F an P erf ormance TWE155B (SI) External Static Pressure (Pascal) 25 50 7 5 100 125 150 174 ...

  • Trane TWA075A - page 28

    28 P erformance Data SSP -PRC0 02-EN (Air Handler) T able PD-22 — Blow er Speeds — TWE20 0B Motor Sheave T urns Open D r i v e 6543210 St an da rd 706 732 758 784 81 1 837 8 63 L o w S t a t i c I 457 478 500 521 542 563 58 5 L o w S t a t i c I I 574 595 617 638 659 680 7 02 Hig h S ta ti c N/A 82 1 86 2 903 94 5 98 6 1027 T able PD-21— Cont ...

  • Trane TWA075A - page 29

    29 P erf ormance Data SSP -PRC0 02-EN T able PD-23— Dischar ge Plenum And Grille Assembly Thr ow Distance — Air Handler — ft (m) Unit Louver Angle Deflection Position Model No. C F M m 3 /h Straight 20 40 55 1400 2378 3 8 (1 1 . 6 ) 2 4 (7 . 3 ) 22 ( 6 . 7 ) 18 ( 5 . 5 ) 1600 2718 4 2 (1 2 . 8 ) 3 1 ( 9 . 4 ) 26 (7 . 9 ) 20 ( 6 . 1 ) TWE050 1 ...

  • Trane TWA075A - page 30

    30 P erformance Data SSP -PRC0 02-EN T able PD-25 — Au xiliary Electr ic Heat Capacity — Air Handler No . Stage 1 Stage 2 T otal U n it T ot a l o f kW B t u kW kW B t u kW B t u kW Model No. k W St ages I nput Output Output Input Output Output Output Output TWE050, 075,100 3. 47 1 3. 47 1 1 ,8 5 1 3 .4 7 — — — 1 1,85 1 3 .4 7 6.92 1 9.92 ...

  • Trane TWA075A - page 31

    31 SSP -PRC0 02-EN Electrical Data T able ED-1— Electr ical Charact eristics — Mot ors — Air Handler Standard Fan Motor Oversized F an Motor Unit Amps Amps Model No. V olts Phase FLA LRA Phase FLA LRA TWE050 380/41 5 3 1 .4 8.2 3 1 .8 21 .6 TWE075 380/41 5 3 3.2 1 9.7 3 4.0 25.5 TWE1 00 380/415 3 3.6 25.5 3 5.3 37 . 5 TWE155 380/41 5 3 4.6 37 ...

  • Trane TWA075A - page 32

    32 SSP -PRC0 02-EN Electrical Data T able ED-5— Unit Wiring With Electr ic Heat (Single Point Connection) — Air Handlers Heater Heater T o Use Control Minimum Maximum Model No. kW Rating 1 with Unit Stages Circuit Ampacity 2 Fuse Breaker Size 2 BA YHTRL405A 3.47 1 9 1 5 BA YHTRL41 0A 6.92 TWE050AD 1 17 20 BA YHTRL415A 1 0.39 1 24 25 BA YHTRL425 ...

  • Trane TWA075A - page 33

    33 SSP -PRC0 02-EN Jobsite Connections Wiring shown with dashed lines is to be furnished and installed by the customer . All customer - supplied wiring must be copper only and must conform to NEC and local electrical codes. Codes may require line of sight between disconnect switc h and unit. NO TE: 1 . When electric heater accessory is used single ...

  • Trane TWA075A - page 34

    34 SSP -PRC0 02-EN T ypical Wiring (Heat P ump) Heat Pump — Single Compressor T ypical unit wiring diagram. For specific wiring, see indi vidual Service Facts. ...

  • Trane TWA075A - page 35

    35 SSP -PRC0 02-EN T ypical Wiring (Heat Pump) ...

  • Trane TWA075A - page 36

    36 SSP -PRC0 02-EN Heat Pump — Dual Compressors T ypical unit wiring diagram. For specific wiring, see indi vidual Service Facts. (Heat Pump) T ypical Wiring ...

  • Trane TWA075A - page 37

    37 SSP -PRC0 02-EN T ypical Wiring (Heat Pump) ...

  • Trane TWA075A - page 38

    38 SSP -PRC0 02-EN T ypical Wiring (Air Handler) Air Handler T ypical unit wiring diagram. For specific wiring, see indi vidual Service Facts. ...

  • Trane TWA075A - page 39

    39 SSP -PRC0 02-EN (Heat Pump) Dimensional Data Figure DD-1 — TW A075 Heat Pump All dimensions are in inc hes and millimeter s. Note 1 MINIMUM CLEARANCE FOR PROPER OPERA TION IS 36 INCHES (914 MM) FROM WALLS, SHRUBBERY , PRIV ACY FENCES, ETC. MINIMUM CLEARANCE BETWEEN ADJACEN T UNITS IS 72 INCHES (1828 MM) ...

  • Trane TWA075A - page 40

    40 SSP -PRC0 02-EN Dimensional Data (Heat Pump) Figure DD-2 — 1 0 T on TW A1 00A Heat Pump All dimensions are in inc hes and millimeter s. Note 1 MINIMUM CLEARANCE FOR PROPER OPERA TION IS 36 INCHES (914 MM) FROM WALLS, SHRUBBERY , PRIVA CY FENCES, ETC. MINIMUM CLEARANCE BETWEEN AD JACENT UNITS IS 72 INCHES (1828 MM) ...

  • Trane TWA075A - page 41

    41 SSP -PRC0 02-EN Dimensional Data (Heat Pump) Figure DD-3 — TW A155B Heat Pump All dimensions are in inc hes and millimeter s. Note 1 MINIMUM CLEARANCE FOR PROPER OPERA TION IS 36 INCHES (914 MM) FROM WALLS, SHRUBBERY , PRIVA CY FENCES, ETC. MINIMUM CLEARANCE BETWEEN AD JACENT UNITS IS 72 INCHES (1828 MM) ...

  • Trane TWA075A - page 42

    42 SSP -PRC0 02-EN (Heat Pump) Dimensional Data Figure DD-4 — TW A200B Heat Pump All dimensions are in inc hes and millimeter s. Note 1 MINIMUM CLEARANCE FOR PROPER OPERA TION IS 36 INCHES (914 MM) FROM WALLS, SHRUBBERY , PRIVA CY FENCES, ETC. MINIMUM CLEARANCE BETWEEN AD JACENT UNITS IS 72 INCHES (1828 MM) ...

  • Trane TWA075A - page 43

    43 SSP -PRC0 02-EN (Air Handler) Dimensional Data Figure DD-5 — TWE050A Air Handlers All dimensions are in inc hes and millimeter s. Notes: 1. Length, Width, and Height Dimensions do not include 1/2” (12.7mm) access panel depth. 2. Removable drain pan and attached drain connection may be installed on either end of unit in either the vertical or ...

  • Trane TWA075A - page 44

    44 SSP -PRC0 02-EN (Air Handler) Dimensional Data Figure DD-6 — TWE075A Air Handler All dimensions are in inc hes and millimeter s. Notes: 1. Length, Width, and Height Dimensions do not include 1/2” (12.7mm) access panel depth. 2. Removable drain pan and attached drain connection may be installed on either end of unit in either the vertical or ...

  • Trane TWA075A - page 45

    45 SSP -PRC0 02-EN Notes: 1. Length, Width, and Height Dimensions do not include 1/2” (12.7mm) access panel depth. 2. Removable drain pan and attached drain connection may be installed on either end of unit in either the vertical or horizontal configuration. Plastic drain pan access plate on the end of unit opposite drain connection must be remov ...

  • Trane TWA075A - page 46

    46 SSP -PRC0 02-EN Dimensional Data (Air Handler) Notes: 1. Length, Width, and Height Dimensions do not include 1/2” (12.7mm) access panel depth. 2. Removable drain pan and attached drain connection may be installed on either end of unit in either the vertical or horizontal configuration. Plastic drain pan access plate on the end of unit opposite ...

  • Trane TWA075A - page 47

    47 SSP -PRC0 02-EN Dimensional Data (Air Handler s) T able DD-1 — Air Handler Dimensions — in. (mm) Model No. AA AB A C AD AE AF AJ AK AL TWE050A 35 5 / 8 12 1 / 16 1 5 / 8 32 1 / 4 2 15 / 16 32 1 / 4 7 13 / 16 12 3 / 8 34 9 / 16 (905) (306.4) ( 41 .3) (81 9.2) (74.6) (81 9.2) (198.4) (314.3) (878) TWE075A 45 1 / 8 16 1 11 / 16 41 15 / 16 6 5 / ...

  • Trane TWA075A - page 48

    48 SSP -PRC0 02-EN Dimensional Data Figure DD-1 0— TWE155B Air Handler All dimensions are in inc hes and millimeter s. (Air Handler) Notes: 1. Length, Width, and Height Dimensions do not include 1/2” (12.7mm) access panel depth. 2. Removable drain pan and attached drain connection may be installed on either end of unit in either the vertical or ...

  • Trane TWA075A - page 49

    49 SSP -PRC0 02-EN Dimensional Data (Air Handler s) Figure DD-1 1 — TWE200B Air Handler All dimensions are in inc hes and millimeter s. Notes: 1. Length, Width, and Height Dimensions do not include 1/2” (12.7mm) access panel depth. 2. Removable drain pan and attached drain connection may be installed on either end of unit in either the vertical ...

  • Trane TWA075A - page 50

    50 SSP -PRC0 02-EN Figure DD-12— TWE155B and 200B Air Handlers All dimensions are in inc hes and millimeter s. T able DD-2 — Air Handler Dimensions — in. (mm) Model No. A B C D E F G H J TWE155B 77 1 / 4 (1 962.2) 1 3 / 16 (30.2) 48 (121 9.2) 1 1 7 / 16 (290.5) 18 (457 .2) 3 3 / 8 (85.7) 35 1 / 16 (890.6) 73 7 / 8 (187 6.4) 3 3 / 4 (95.3) TWE ...

  • Trane TWA075A - page 51

    51 SSP -PRC0 02-EN Dimensional Data ( A ccessories) Figure DD-13— Electr ic Heat er for TWE050, 075, 1 00 Air Handlers All dimensions are in inc hes and millimeter s. Figure DD-14 — Electr ic Heater for TWE155 and 20 0 Air Handlers ...

  • Trane TWA075A - page 52

    52 SSP -PRC0 02-EN Mec hanical Specif ications Heat Pumps General Unit shall be assembled on heavy gauge steel mounting/lifting rails and shall be weather proofed. Unit shall include a hermetic scroll or reciprocating compressor(s), plate fin condenser coil, fans and motors, controls, and holding c harge of nitrogen. Operating Range shall be betwee ...

  • Trane TWA075A - page 53

    53 SSP -PRC0 02-EN Air Handlers General Air handler units shall be completely factory assembled including coil, condensate drain pan, fan motor(s), filters, and controls in an insulated casing that can be applied in either ver tical or horizontal configuration. Unit shall be rated and tested in accordance with ARI standard 340/360. Unit shall be UL ...

  • Trane TWA075A - page 54

    ...

  • Trane TWA075A - page 55

    ...

  • Trane TWA075A - page 56

    T rane An American Standard Compan y www .trane.com For more information contact your local office or e-mail us at comfort@trane.com Since T rane has a policy of continuous product and product data improvement, it reserves the right to c hange design and specifications without notice. Literature Order Number File Number Supersedes Stoc king Locatio ...

Fabricant Trane Catégorie Heating System

Les documents que nous recevons du fabricant de l'appareilTrane TWA075A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Trane
- manuels d’utilisations TWA075A
- fiches produit Trane
- dépliants
- ou étiquettes-énergie Trane TWA075A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Trane TWA075A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Trane TWA075A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Trane TWA075A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Trane TWA075A.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Trane TWA075A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Trane TWA075A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Trane TWA075A.

Le manuel d’utilisation complet Trane, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Trane TWA075A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Trane TWA075A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTrane TWA075A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Trane TWA075A - qui devraient nous aider dans les premières étapes lors de l'utilisation Trane TWA075A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Trane TWA075A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Trane TWA075A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Trane TWA075A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Trane TWA075A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Trane TWA075A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)