    IS3480 Quantum E ® Scan Engine User’s Guide ...

  • Honeywell QUANTUME IS3480 - page 2

    Disclaimer Honeywell International In c. (“HII”) reserves the ri ght to make changes in specifications and other inform ation cont ained in this docu ment without prior notice, and the reader should in all c ases consult HII to determine whether an y such changes have been made. The inform ation in this publication does not represent a commitme ...

  • Honeywell QUANTUME IS3480 - page 3

    ii T ABLE OF C ONTENTS Introduction Product Over view ............................................................................................. 1 Scanner and A ccessories ................................................................................. 2 Maintenanc e .............................................................................. ...

  • Honeywell QUANTUME IS3480 - page 4

    iii T ABLE OF C ONTENTS IR Activati on Ran ge ........................................................................................ 25 Troubleshootin g Guid e ....................................................................................... 26 Design Specif ications .......................................................................... ...

  • Honeywell QUANTUME IS3480 - page 5

    1 I NTRODUCTION Quantum E ® is a miniature, omni-directional scanning engine with optional single- line scanning capabil ity. The self-contai ned devic e is fully enclosed elimin ating the need for an external window or custom enclosure. It is designed for use in OEM equipment such as price lookup s ystems and kiosks. Quantum E s slim design makes ...

  • Honeywell QUANTUME IS3480 - page 6

    2 I NTRODUCTION Scanner and Accessories B ASIC K IT C OMPONENTS Part No. Description IS3480 Quantum E Scanner 00-02026 IS3480 Installation and User’s Guide * 00-02407 MetroSelect ® Configuration Guide * * Guides also available for dow nload at www.honeywellaidc .com. O PTIONAL A CCESSORIES Part No. Description AC to DC Power Transformer - Regula ...

  • Honeywell QUANTUME IS3480 - page 7

    3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part No. Description 59-59002x-3 Keyboard Wedge PowerLink cable 59-59020x-3 Stand Alone Keyboard Po werLink cable 59-59235x-N-3 Low Speed USB Non-Locking Communication Cable straight cord, shor t strain relief 35-35959 Utility Flex Cable 59-59249x-N-3 Communication Cable, Host end Not T ...

  • Honeywell QUANTUME IS3480 - page 8

    4 I NTRODUCTION Scanner Components Figure 1a. Scanner Components I TEM N O . D ESCRIPTION 1 Utility Connector Located Un der Rubber Seal The rubber seal protecting the utilit y connector should only be removed if the utility connector is to be used. 2 10-Pin RJ45, Female Socket 3 Blue, White and Yellow LED Indic ators 4 Red Output Window (Laser Ape ...

  • Honeywell QUANTUME IS3480 - page 9

    5 I NTRODUCTION Caution and Serial Number Labels Figure 2. Caution To maintain compliance with applicable standards, all circuits conne cted to the scanner must meet the requirements for SELV (S afety E xtra L ow V oltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, th ...

  • Honeywell QUANTUME IS3480 - page 10

    6 I NSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480. 3. Connect the 9-pin female end of the PowerLink cable to the host device. Note: Skip to step 6 if receiving power from the host device. 4. Plug the external power ...

  • Honeywell QUANTUME IS3480 - page 11

    7 I NSTALLATION RS485  1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS3480. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host device. When the scanner first receives po we r, the blue LED will turn on; the scanner will simultaneously beep once and fla ...

  • Honeywell QUANTUME IS3480 - page 12

    8 I NSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480. 3. Disconnect the keyboard from the host device. 4. Connect the “Y” end of the PowerLink cable to the keyboar d and the keyboard port on the host device. If necessary, use the male/female adap ...

  • Honeywell QUANTUME IS3480 - page 13

    9 I NSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480. 3. Connect the other end of the PowerLink cable to the keyboard port on the host device. 4. Plug the external power supply int o the power jack on the PowerLink cable. Check the AC input req ...

  • Honeywell QUANTUME IS3480 - page 14

    10 I NSTALLATION Low Speed USB (Integrated) 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-pin socket on the IS3480. 3. Plug the other end of the USB interface cable into the host device’s USB port. 4. Turn on the host device. As a default, the IS3480-38 leaves the factory with USB Keyboard Em ...

  • Honeywell QUANTUME IS3480 - page 15

    11 I NSTALLATION Notes for Laser Emulation IS3480-104 Only The IS3480-104 leaves the fa ctory with the Laser Emulation Mode enabled . If the Recall Defaults bar code is sc anned while reconfiguri ng the scanner, the laser emulation mode will no longer be enabl ed. Scan the following bar code to re-enable the l aser emulation interface. This feature ...

  • Honeywell QUANTUME IS3480 - page 16

    12 S CANNER O PERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable sc an pattern modes available with the IS3480. • The primary scan pattern mode is the default scan pattern active when the scanner starts. • The secondary scan pattern mode is activated by pressing the button located on the side of the scanne ...

  • Honeywell QUANTUME IS3480 - page 17

    13 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON C LICK M ODE WITH C ODE G ATE E NABLED For illustration purposes the unit’s primary sc an pattern has been set to all scan lines (omnidirectional reading) and the secondar y pattern has been set to single-line (menu reading) with a 10 second but ton click timeo ...

  • Honeywell QUANTUME IS3480 - page 18

    14 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON C LICK M ODE WITH C ODE G ATE D ISABLED For illustration purposes the unit’s primary sc an pattern has been set to all scan lines (omnidirectional reading) and the secondar y pattern has been set to single-line (menu reading) with a 10 second but ton click time ...

  • Honeywell QUANTUME IS3480 - page 19

    15 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON H OLD M ODE WITH C ODE G ATE E NABLED For illustration purposes the unit’s primary sc an pattern has been set to all scan lines (omnidirectional reading) and the secondar y pattern has been set to single-line (menu reading) with a 10 second but ton click timeou ...

  • Honeywell QUANTUME IS3480 - page 20

    16 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON H OLD M ODE WITH C ODE G ATE D ISABLED For illustration purposes the unit’s primary sc an pattern has been set to all scan lines (omnidirectional reading) and the secondar y pattern has been set to single-line (menu reading) with a 10 second but ton click timeo ...

  • Honeywell QUANTUME IS3480 - page 21

    17 S CANNER O PERATION Sweet Spot Mode The sweet spot mod e is used to determine where the maximum read rate area or “sweet spot” is located for a specific bar code type. When activated this mode provides visual and audi ble feedback indicating ho w the scanner is scanning. Number of Illuminated LEDs Beeper Pitch % of Maximum Read Rate 4 high 8 ...

  • Honeywell QUANTUME IS3480 - page 22

    18 S CANNER O PERATION Audible Indicators When the IS3480 is in operati on, it can provide audible feedback. These soun ds indicate the status of the scanner. Eight settings are availab le for the tone of the beep (normal, six alternate tones and no to n e). For instruction on how to change the tone of the beeper, refer to the Metr oSelect Configur ...

  • Honeywell QUANTUME IS3480 - page 23

    19 S CANNER O PERATION Visual Indicators There are four LEDs locat ed on the top of the IS3480. When the scanner i s on, the flashing or constant il luminatio n of the LEDs indi cates the status of the current scan and the scanner. No LEDs The LEDs will not be illumi nated if the scanner is not receivi ng power from the host or transformer. They ar ...

  • Honeywell QUANTUME IS3480 - page 24

    20 S CANNER O PERATION Failure Mode Indicators Flashing Blue a nd One Razzberry Tone This indicates that the scanner has experien ced a laser subsystem failure. Return the unit to an authoriz ed service center for repair. Flashing Blu e and White and Tw o Ra zz b er ry Tones This indicates that the scanner has experien ced a motor failure. Return t ...

  • Honeywell QUANTUME IS3480 - page 25

    21 S CANNER O PERATION Depth of Field Specifications* Normal Scan Zone Specifications are based o n a 0.33 mm (13 mil) bar code. Figure 9. Normal Depth of Field * All specifications are subject to change w ithout notice. ...

  • Honeywell QUANTUME IS3480 - page 26

    22 S CANNER O PERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based o n a 0.33 mm (13 mil) bar code. Figure 10. Reduced Depth of Field * All specifications are subject to change w ithout notice. ...

  • Honeywell QUANTUME IS3480 - page 27

    23 S CANNER O PERATION Depth of Field by Bar Code Element Width* Normal Scan Zone M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F mm .13 .15 .19 .25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 11. Normal Scan Zone by Bar Code Element W idth * All specifications are subject to change w ithout notice. ...

  • Honeywell QUANTUME IS3480 - page 28

    24 S CANNER O PERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F mm .13 .15 .19 .25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 12. Reduced Scan Zone by Bar Code Ele ment Width * All specifications are subject to change w ithout notice. ...

  • Honeywell QUANTUME IS3480 - page 29

    25 S CANNER O PERATION IR Activation Range* Quantum E ’s default power save mode † is Laser OFF . This power save mode turns the laser off after a configured per iod of non-us e. Any movement detected by the IR in the activation area will cause the scanner to exit power save mode. The laser will automatically tur n back on preparing the scanner ...

  • Honeywell QUANTUME IS3480 - page 30

    26 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Honeywell representative to preserve the limited warranty terms on page 47. Symptoms Possible Cause(s) Solution All Interfaces The unit has no LEDs, beeper or motor spin. No power is being supplied to the scanner. Check the transformer, outlet and power strip. ...

  • Honeywell QUANTUME IS3480 - page 31

    27 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan ( the white LED stays on ). The scanner is configured to support some form of host handshaking but is not receiving the signal. If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that t ...

  • Honeywell QUANTUME IS3480 - page 32

    28 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution RS232 Only The unit powers up OK and scans OK but does not communicate properly to the host. The com port at the host is not working or is not configured properly. Check to make sure that the baud rate and parity of the scanner and the communication port match and that the program is lo ...

  • Honeywell QUANTUME IS3480 - page 33

    29 D ESIGN S PECIFICATIONS IS3480 Operational Normal Depth of Field: 25 mm - 280 mm (1"- 11") 0.33 mm (13 mil) bar code Reduced Depth of Field: 25 mm - 150 mm (1"- 6") Omni Scan Scan Speed: 1650 scan lines per second No. of Scan Lines: 20 Single-Line Scan Speed: 80 scan lines per second No. of Scan Lines: 1 Raster Scan Speed: 32 ...

  • Honeywell QUANTUME IS3480 - page 34

    30 D ESIGN S PECIFICATIONS IS3480 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g) Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 1.375 W Standby Power: 1.0 W Operating Current: 275 mA typical at 5VDC Standby Current: 200 mA typical at 5VDC DC Transformers: Class II; 5.2VDC @ ...

  • Honeywell QUANTUME IS3480 - page 35

    31 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMM UNICATIO N P ROTOCOL ( S ) IS3480 11 RS485  and Full RS232 C 38 RS232 Low Speed USB, Keyboar d Emulation or Serial Emulation 41 Full RS232C/Light Pen Emulation 47 Keyboar ...

  • Honeywell QUANTUME IS3480 - page 36

    32 C ONFIGURATION M ODES The IS3480 Series scanner has three mod es of configuration. • Bar Codes The IS3480 can be configur ed by scanning the bar codes inclu ded in the Single-Line Configur ation Guide or the Supplemental Confi guration Guide. The manuals are availab le for download at www . honeywellaid c.com . • MetroSet 2 This user-friendl ...

  • Honeywell QUANTUME IS3480 - page 37

    33 U PGRADING THE F IRMWARE The IS3480 is part of Honeywell's lin e of scanners with flash upgr adeable firmware. The upgrade process requir es, a new firmware file supplied to the customer by a customer service representativ e  and Honeywell's MetroSet 2 software  . A personal computer running Windo ws 95 or greater with an avai ...

  • Honeywell QUANTUME IS3480 - page 38

    34 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS Many functions of the scanner can be "config u red" - that is enabled or disabled. The scanner is shipped from the factor y c onfigured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in ...

  • Honeywell QUANTUME IS3480 - page 39

    35 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT USB RS232* OR RS232 TTL L IGHT P EN RS485  KBW L ASER E MULATION Expanded ID “]e0” *       GS1 DataBar Limited Enable       GS1 DataBar Limited ID “]e0” *       GS1 DataBar Limit ...

  • Honeywell QUANTUME IS3480 - page 40

    36 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT USB RS232* OR RS232 TTL L IGHT P EN RS485  KBW L ASER E MULATION Transmit UPC-A Check Digit *             Transmit UPC-E Check Digit             Expand UPC-E            ? ...

  • Honeywell QUANTUME IS3480 - page 41

    37 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT USB RS232* OR RS232 TTL L IGHT P EN RS485  KBW L ASER E MULATION Nixdorf ID          LRC Enabled          UPC Prefix          UPC Suffix          Transmit AIM ID Charac ...

  • Honeywell QUANTUME IS3480 - page 42

    38 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT USB RS232* OR RS232 TTL L IGHT P EN RS485  KBW L ASER E MULATION Supplements are not Required *             Two Digit Redundancy *             Five Digit Redundancy           ...

  • Honeywell QUANTUME IS3480 - page 43

    39 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections The IS3480 scanner interface s terminate to a 10-pin modular socket. The serial number label i ndicates the interface enabl ed when the scanner is shipped from the factory. Figure 14. IS3480- 47 Keyboard W edge and Stand-Alone Keyb oard IS3480- 41 RS232 and Light Pen Emulation Pin Func ...

  • Honeywell QUANTUME IS3480 - page 44

    40 S CANNER AND C ABLE T ERMINATIONS Figure 15. IS3480- 104 RS232, RS232 TTL, or Laser Emulation Pin Function 1 Ground 2 RS23 2 Transmit Output 3 RS23 2 Receive Input 4 RT S Output (TTL RS232) / Flip Sense 5 CT S Input (TTL RS232) / Trigger Emulation Output 6 DT R Input (TTL RS232) / Scan Enable 7 Receiv e (TTL RS232) / Good Read 8 T ransmit (TTL R ...

  • Honeywell QUANTUME IS3480 - page 45

    41 S CANNER AND C ABLE T ERMINATIONS Figure 16. Figure 17. Zero Insertion Force Connector (ZIF), 6-pin Utilit y Connector Pin Function 1 Aux +5V: Power out. Can supply up to 100mA @ 5V. 2 Good Read: Open-collector output. Lo w -go ing 20mA output for duration of 32 ms at a baud rate of 9600. Represent s a successful bar code read. Can be used to dr ...

  • Honeywell QUANTUME IS3480 - page 46

    42 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000x-3 coile d or 59-59000x-3 st raight Pin Function 1 Shield Ground 2 RS23 2 Transmit Output 3 RS23 2 Receive Input 4 DT R Input/Light Pen Source 5 Power/Signal Ground 6 Lig ht Pen Data 7 CT S Input 8 RTS Output 9 +5VDC USB Power/Comm ...

  • Honeywell QUANTUME IS3480 - page 47

    43 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge Po werLink Cable 59-59002x-3 Pin Function 5-Pin DIN, Female 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC Pin Function 6-Pin DIN, Male 1 PC Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect Honeywell will s ...

  • Honeywell QUANTUME IS3480 - page 48

    44 R EGULATORY C OMPLIAN CE Safety ITE Equipment IEC 60950-1: 2005+A11, EN 60950-1:2006+A11 Laser Laser Class 1: IEC 60825-1:2007+A1+A2, EN 60825-1:2007+A1+A2 Caution Use of controls or adj ustments or performance of proc edures other than those specifi ed herein may res ult in hazardous laser light exposure. Under no circumst ances should the cust ...

  • Honeywell QUANTUME IS3480 - page 49

    45 R EGULATORY C OMPLIAN CE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity per formance is not guar anteed for scanner ca bles grea ter than 3 me ters in length when f ully extended. Changes or mo difications not ex pressly approved by the party respons ible for compliance could void the user’s ...

  • Honeywell QUANTUME IS3480 - page 50

    46 R EGULATORY C OMPLIAN CE EMC Changes or modifications not expressly approved by the part y responsible for compliance could void the user’s authority to operate the equipment. Standard Eu ropeo Attenzione Questo e’ un prodotto di classe A . Se usato in vicina nza di residenze p rivate potrebbe causare inter ferenze radio che po trebbero rich ...

  • Honeywell QUANTUME IS3480 - page 51

    47 L IMITED W ARRANTY Honeywell International Inc. ("HII") warrants its products and optio nal accessories to be free from defects in materials and workmanship and to conform to HII’s published specifications applicabl e to the products purchased at the time of shipment. This warranty does not cover any HII prod uct which is (i) imprope ...

  • Honeywell QUANTUME IS3480 - page 52

    48 L IMITED W ARRANTY All provisions of this Limited Warranty are separate an d severable, which means that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enf orceabilit y of the other prov isions hereof. Use of any peripherals not provided by the manufactur er may result in damage not covere ...

  • Honeywell QUANTUME IS3480 - page 53

    49 P ATENTS For patent information, please refer to www.honey wellaidc.com/patents. ...

  • Honeywell QUANTUME IS3480 - page 54

    50 I NDEX A AC ....................................... 2, 6–10 Accessories ............................... 2, 3 Adapter .......................................... 8 Audible Indicator .. 12, 18–20, 26–28 B Bar Code ....... 18–20, 26–28, 29, 32 Bar Width ..................................... 29 Beep .................... 18, 19, 20, 26–28 ...

  • Honeywell QUANTUME IS3480 - page 55

    51 I NDEX M Maintenanc e .................................. 3 Manual............................... 2, 18, 31 MetroSelec t ................................. 32 Mode of Operation Button ...................................... 17 Primary .............................. 12–17 Secondary .......................... 12–17 Sweet Spot Mode .............. ...

  • Honeywell QUANTUME IS3480 - page 56

    52 C USTOMER S UPPORT Technical Assistance If you need assistance installing or troubl esho oting your devi ce, please call your distributor or the nearest technical supp ort office: North Amer ica/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeyw ell.com Latin A merica Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasup ...

  • Honeywell QUANTUME IS3480 - page 57

    53 C USTOMER S UPPORT Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obt ain warranty or non- warranty service, contact the appropriate location belo w to obtain a Return Material Authorization number (RMA #) before returning the product. North America T ...

  • Honeywell QUANTUME IS3480 - page 58

    54 C USTOMER S UPPORT Online Product Service and Rep air Assistance You can also access product service and repair ass istance online at www.honeywellaidc.com. ...

  • Honeywell QUANTUME IS3480 - page 59

    ...

  • Honeywell QUANTUME IS3480 - page 60

    Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02026 Rev H 11/10 ...

Fabricant Honeywell Catégorie Scanner

Les documents que nous recevons du fabricant de l'appareilHoneywell QUANTUME IS3480 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Honeywell
- manuels d’utilisations QUANTUME IS3480
- fiches produit Honeywell
- dépliants
- ou étiquettes-énergie Honeywell QUANTUME IS3480
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Honeywell QUANTUME IS3480.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Honeywell QUANTUME IS3480, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Honeywell QUANTUME IS3480. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Honeywell QUANTUME IS3480.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Honeywell QUANTUME IS3480, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Honeywell QUANTUME IS3480 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Honeywell QUANTUME IS3480.

Le manuel d’utilisation complet Honeywell, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Honeywell QUANTUME IS3480 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Honeywell QUANTUME IS3480, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHoneywell QUANTUME IS3480 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Honeywell QUANTUME IS3480 - qui devraient nous aider dans les premières étapes lors de l'utilisation Honeywell QUANTUME IS3480
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Honeywell QUANTUME IS3480
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Honeywell QUANTUME IS3480 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Honeywell QUANTUME IS3480?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Honeywell QUANTUME IS3480, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Honeywell QUANTUME IS3480 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)