Manuel d’utilisation Aquacal H120

36 pages 1.46 mb
Télécharger

Aller à la page of 36

Summary
  • Aquacal H120 - page 1

    POO L & SPA HEAT PUMP O WNER’S MANUAL H e a t W a v e A e r o T e m p H 1 0 0 A T 1 0 0 H 1 2 0 A T 1 2 0 N O T E : T H I S M A N U A L A L S O A P P L I E S T O X L 1 0 0 , X L 1 2 0 , S B 1 2 0 , & A P S 1 2 0 M O D E L S ...

  • Aquacal H120 - page 2

    2 Owner Note s ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ___________________ ...

  • Aquacal H120 - page 3

    3 Table of Contents WELCOME TO THE AQUACA L FAMILY ..................... ........... ............ ........... 4 IMPORTANT FEATURES OF YOUR NEW HEAT PUMP ........... ............ ......4 GENERAL SAFETY INFORMA TION ........... ............ ........... ............ ........... .......5 WATER CHEM I STRY & TEMPERATURE FACTOR S .................... ...

  • Aquacal H120 - page 4

    4 WELCOME TO THE AQUACAL FAM ILY Congratulations on your wise decision to make an AquaCal heat pump part of your home. Since 1981, AquaCal has m aint ained the worldwide lead in the manufacture of swimm ing pool & spa heat pumps. Your new heat pump is not only a great investment, but also the m ost cost effective method available for heating po ...

  • Aquacal H120 - page 5

    5 GENERAL SAF ETY INFORM ATION Used and maintained properly, y our heat pump will provide year-upon-year of safe and economical service. However, as wi th any mechanical or electrical device, to get the most from your heat pump– while i nsuring personal safety for you and others –certain operational and maintenance fact ors must be observed. Li ...

  • Aquacal H120 - page 6

    6 WATER C HEMI STRY & TE MPE RATURE FACT ORS Water Temperature Safety Factors Water Chemistry Safety Factors RECOMMENDED CH EMISTRY WATE R STANDARDS Chlorine…………… …: 1.0 – 3.0 ppm in pools , 1.5 – 3.0 ppm in spas Bromine…………… …: 2.0 – 4.0 ppm in pools , 3.0 – 5.0 ppm in spas PH……………… …….: 7.4 – ...

  • Aquacal H120 - page 7

    7 HOW A HEAT PUMP WO RKS T HE FOLLO WING E XPLANA TION IS P ROVIDED T O HEL P YOU I N UNDERSTA NDING WHAT TO EXPECT FROM YO UR HE AT PUMP … A Heat Pump Does Not Make Heat… Heat pumps are so extraordinarily efficient because they do not need to produce heat in order to warm pool or spa water. R ather, heat pumps sim ply transfer heat from the ou ...

  • Aquacal H120 - page 8

    8 GETTING F AMILIAR WITH CONTROLS DIGITAL CONT ROLLER – PAN EL L AYOUT Control Buttons ( AS INDICATED BY CIRCLED LETTERS ) A. Down Arrow – Pressing th is key decreases the temperature setting. Setting the temperature below 60°F turns the heat pump off. B. Pool / Spa Selector – Pressing this key selects either the pool or spa m ode. Also used ...

  • Aquacal H120 - page 9

    9 DIGITAL CONT ROLLER - OPER ATIONAL DIS PLAYS T HE FOLLOWING CODES WI LL BE DISPLAYED AS PART OF THE NORMAL OPERATI ON OF THE HEATER : OPERATIONAL CODES o FLO —No water flow detected. Code message will appear any time the circulating pump is off, or when the hea ter is not receiving correct water flow. o OFF —Syste m is off. Sy stem is off unt ...

  • Aquacal H120 - page 10

    10 GETTING YO UR HEAT P UMP STARTED & STOPP ED ATTENTION: THIS IS A QUICK-START GUIDE …For m ore complete information concerning the digital controller features a nd programm ing, see: Owner’s Instructions for HP7 Digital Heat Pump Controller, locate d in the appendix of this manual. INITIAL START UP 1. Start the water circulator pum p. NOT ...

  • Aquacal H120 - page 11

    11 GETTING YOUR HEAT PUMP STARTED & STOPPED (Continued) 8. In operation, whenever the actual (display ed) water temperature falls below the desired set point, the unit will start heat ing after an initial time delay of 3-4 minutes. NOTE: T HE HEA T PUMP INCORPORA TES AN ANTI - SHOR T CYCLE TIME DELAY . S HOULD OPERATION BE INTERRUPTED , RESTAR ...

  • Aquacal H120 - page 12

    12 MAINTENAN CE PLANNE D MAI NTENANCE PROG RAM AquaCal offers a very reasonably priced, profess ionally-performed, Planned Maintenance Program ….See APPENDIX for full details. GENERAL MAI NTENANCE o You should have your heat pum p inspected and maintained on an annual basis by a qualified pool heat pump specialist. Additionally, if your heat pump ...

  • Aquacal H120 - page 13

    13 MAINTAI NING PROPER WATE R FLOW o It is important to operate and m aintain your filter according to the m anufacturer’s specifications. As a filter gets dirty, the water flow to the heat pump is reduced. The higher the pressure on the filter gauge, the lower t he flow rate. o Similar to a dirty filter, large am ounts of debris in the pump bask ...

  • Aquacal H120 - page 14

    14 Recommended Clearances… Sides, Front, and Rear 12-I NCHES (R EAR ) 24-I NCHES ( SIDE ) 24-I NCHES ( SIDE ) 30-I NCHES ( FRONT ) ...

  • Aquacal H120 - page 15

    15 Recommended Clearances… Overh ead, Front, & Rear: RAIN RUN - OFF MUST BE DIRECTED AWAY FROM UNIT . OVERHANG WI TH GUTTER 30” M INIMUM C LEARANCE , F RONT 1 F T . MINIMUM C LEARANCE , R EAR 5 FT . MINIMUM CLEARANCE , O VERHEAD No Scale ...

  • Aquacal H120 - page 16

    16 SEASONAL USE & SHUT DOW N DURING T HE SW IM SEAS ON o During the swim season, even if the pool or spa is not in use, al low water to flow through the heater. o This eliminates the need to repositi on valves when you do wish to heat your pool or spa. FREEZE P ROTE CTION / E XTEND ED SHUT DO WNS o In areas where freezing conditions are a ra re ...

  • Aquacal H120 - page 17

    17 Winterizing (Cont inued) 5. Permit all of the water to drain out of the condenser and then, threading clockwise, replace the plug finger-tight. 6. Reinstall the heater front cover and secure w ith attaching screws previously removed. 7. To prevent insects and verm in from entering the plum bing during the winterized period, partially reconnect t ...

  • Aquacal H120 - page 18

    18 Winterizing (Conti nued) To Winterize a Heat Pump Equipp ed with an External Drain (Per Figure-3) 1. Disconnect all electrical power to the heat er; turn OFF circulating pump. 2. At the two (2) connection unions, disc onnect the plumbing to the heater (removal is counter-clockwise). 3. Locate the drain plug at lower, right-hand, front corner of ...

  • Aquacal H120 - page 19

    19 TROUBLESH OOTING HEAT PUM P NOT RUNNIN G o Is the display lit? If not, ensure the m ain breaker (located at the power supply panel) and the disconnect switch (located ne ar the heat pump) are both turned ON. o Doe s the display read “Flo”? If so , check to be sure that the circulating pump is operating and the filter is clean. There m a y al ...

  • Aquacal H120 - page 20

    20 WATER LE AKI NG OUT O F TH E HEAT PUM P (Is it a leak or just condensation from normal oper ation? Here’s how to find out). o Sh ut off your heat pum p, leaving the pool pump running. In a couple of hours there should be a marked reduction in the a mount of water around the bottom of the heat pump. o Or, as an alternate m ethod to check for a ...

  • Aquacal H120 - page 21

    21 APPENDIX I. AQUACAL’S PLANNE D MAINTENANCE PROGRAM II. CALCULATING INIT IAL HEATING TIME III. OWNER’S INS TRUCTIONS FOR H P7 DIGITAL HEAT PUMP CONT ROLLER ...

  • Aquacal H120 - page 22

    PLANNE D MAI NTENANCE PROG RAM Just as you would have yearly service performed on your air conditioning system, regular inspection & m aintenance of your AquaCal heat pump will insure highest operating efficiencie s while also protecting your investment… Potentially extending the useful life o f your heat pump far beyond the warranty period. ...

  • Aquacal H120 - page 23

    CALCULAT ING REQUIRE D HE ATING TIM E The initial time it takes to get your pool warm depends on several factors. First you will need to determ i ne ho w m any gallons of water are in your pool. If y ou know this, you can com pute the pounds of water in the pool and the BTU’s necessary to heat the pool to the desired tem perature. Secondly, you n ...

  • Aquacal H120 - page 24

    When you start up your new AquaCal Heat Pump for the fir st time to heat your pool, you must allow the unit to run continuously unti l the desired temperature is reached. This may take from several hours to several days depending upon the tim e of the year and the outside conditions. If y ou utilize a time clock or similar device to control the ope ...

  • Aquacal H120 - page 25

                                           ? ...

  • Aquacal H120 - page 26

    2 TABLE of CONTENTS GENERA L DESCRIPTION OF HP7 CONTROL LER ............................................................................... 3 HP7 CONTROLLER SPECIFICATIONS .................................................................................................... 3 I NPUTS : ................................................................. ...

  • Aquacal H120 - page 27

    3 GENERAL DE SCRIPTION of HP7 CONTRO LLER The HP7 is a powerful microproc essor control designed for use in swim ming pool & spa heat pumps. The control features 3-di git temperature and set point di spla y, with programming changes easil y performed by simple 3-ke y operation. The HP7 offers precise water tempe rature control, accurate de fros ...

  • Aquacal H120 - page 28

    4 CO NTROL PANEL LAYOUT (App earance will va ry between model lin es) ...

  • Aquacal H120 - page 29

    5 START UP & SETTING OPERATING CO NTROLS 1. Applying Power to The Controller: A. W hen power is first applied, the control pe rforms a lamp test and the displ ay will read [888]. Additionall y, all status LED’s lights will illum inate for 4 seconds and then go o ff for 1 second. B. The control will then displ ay the actual temperature as lon ...

  • Aquacal H120 - page 30

    6 5. Changing The Pool Te mperature Set Point: A. Usi ng the Pool / Spa ke y, select the POOL temperature set poin t. The pool set poi nt indicator light will confirm your selection b y lig hting. B. The pool temperature set point range is adjustable from 6 0 ° F. to 95 ° F (104 ° F in latest models) . using the Up     or Down  ? ...

  • Aquacal H120 - page 31

    7 Selecting ULC Option (Con tinued): 4) With [ULC] displayed, pressing either the Up o r Down arrow ke y will display either (1) or (0). Selecting (0) will allow the control keypad to remain unl ocked. Selecting (1) will enable the User Lock Cod e option. Then, to enter a lock code number, press the pool/spa key once. [E LC] (Enter Lock Code) wi ll ...

  • Aquacal H120 - page 32

    8 Selecting Call / Flex Pump Options [C FO] … ( This feature will apply only if the heater installation includes a C all/Flex module.) : A. Depress both t he Up     and Down     arrow keys simultaneousl y until [CF1] display appears. Depress the poo l/spa key twice, the displ ay will appear. B. With the [CFO] (Call Flex Op ...

  • Aquacal H120 - page 33

    9 OWNER TROUBL ESHOOTING Owner Troub leshooting Procedure: Note… This procedure is restricted to problems which may be related to t he control s ystem of your heater, and/or site conditions affecting th e ability of the control s ystem to properly start and run your heater. For other suspected problems , such as (but not li mited to): “Heater L ...

  • Aquacal H120 - page 34

    10 Sequence of O peration PU MP OFF POW ER ON ______________________ "FLO" D ispl ayed PUMP ON POW ER ON ______________________ W at er Temp. D ispl ayed SE T POINT BE LOW 60º F ______________________ Heater is "OFF" Pressin g Up-Dow n Keys W ill Display "OFF", W ater Tem p. Displayed SE T POINT ABOVE 60ºF __________ ...

  • Aquacal H120 - page 35

    11 CONTACTING the FACTORY… Should you ever exp erience problems with your h eater, or if you simply desire further information a bout your heater’s operation, our Customer Support staff stands ready to assist. Please call us toll-free at: 1-800-786-7751. We Sincerely Appreciate Your Business…. Thank you for choosing AQUACAL for your swimming ...

  • Aquacal H120 - page 36

    12     2737 24 th Street North St. Petersburg, FL 3371 3 800-786-7751 www.aquacal.com ...

Fabricant Aquacal Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilAquacal H120 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Aquacal
- manuels d’utilisations H120
- fiches produit Aquacal
- dépliants
- ou étiquettes-énergie Aquacal H120
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Aquacal H120.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Aquacal H120, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Aquacal H120. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Aquacal H120.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Aquacal H120, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Aquacal H120 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Aquacal H120.

Le manuel d’utilisation complet Aquacal, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Aquacal H120 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Aquacal H120, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAquacal H120 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Aquacal H120 - qui devraient nous aider dans les premières étapes lors de l'utilisation Aquacal H120
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Aquacal H120
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Aquacal H120 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Aquacal H120?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Aquacal H120, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Aquacal H120 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image