  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 1

    Owners Guide and Installation Instructions Solar Loline Conversion Kit Electric Water Heater W A RNING: Pl umber – Be A w are Use copper pipe O NLY . Plastic p ipe MUST NOT be used. It is a requirement o f a solar water heate r installation th at all pipe work be in cop per and not plastic, du e to the effec ts of high water tempera tures and pre ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 2

    WARNING: Plumber – Be Aware: · The solar col d and hot pi pes bet ween the solar storage tank and t he s olar collectors MUS T BE of copper and fu lly insu lated with Armaflex ins ulation or similar (minimum thickness 10 mm). · Plastic pipe MUST NOT be used, as it w ill not withstand the temper ature of the water generated by the solar colle ct ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 3

    CONTENTS 3 HOUSEHOLDER – We recomme nd y ou read p ages 4 to 1 7. The other pages ar e intende d for the in staller but ma y be of int erest. About y our w ater heater ..................................................................... 4 Regular care ......................................................................................... 9 How ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 4

    ABOUT YOUR WATER HEATER 4 MODEL TYPE Congratulations for choosing a Rhee m electric water heater and a Rheem sola r conversion kit. The Rheem solar co nversion kit co nverts your Rheem e lectric wat er heater into a Rheem solar Loline water heater. Your Rheem solar Loline wate r heater is designed fo r the solar collect ors to be roof mount ed and ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 5

    ABOUT YOUR WATER HEATER 5 HOTTER W ATER INCRE ASES THE RISK OF SC ALD INJURY W e recommend, and it may also be required by regulatio ns, that an approved temperature limiting device, such as the Rheem Temp-Set, be fitted into the hot water piping to th e bathroom and ens uite when this water he ater is installed. T his will keep the water temperat ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 6

    ABOUT YOUR WATER HEATER 6 · · TO TURN ON THE WATER HE ATER · Open the cold water isolatio n valve full y at the inlet to t he wate r heater. · If the solar collectors and solar hot a nd cold pipes h ave been drained, it will be necessary to blee d the coll ector circuit (r efer to “Blee ding the Solar Collectors” on page 7). If the electric ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 7

    ABOUT YOUR WATER HEATER 7 ANODE PROTECTI ON The anode installe d in your water heater will slowly dissipate whilst protecti ng the cylinder. The life of the water heat er cylinder may be extende d by arranging for an authorised person to inspect t he anode an d replacing it i f requir ed. The suggested tim e after inst allation when the anode shoul ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 8

    ABOUT YOUR WATER HEATER 8 FLUSHING THE SO LAR COLLECT ORS It may be necessary to flush the sola r collectors if there is s ediment in the water supply. To flush th e solar collectors, follo w the procedure “Bleeding the Solar Collectors” on page 7, allowing the water to flow from th e bleed valve drain line fo r five minutes before closing t he ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 9

    REGULAR CARE 9 TEMPER ATURE AND PRESSURE RELIEF V ALVE This valve is near th e top of the water h eater and is essential for its s afe operat ion. It is possible for the valve to release a little water through th e drain pipe during each h eating period. T his occurs a s the water is heated and e xpands b y approximate ly 1/50 of its vol um e. Neve ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 10

    HOW YOUR WATER HEATER WORKS 10 The Rheem s olar Loline system has its vitreous enamel lined solar storage ta nk installed at ground or floor level, remot ely from the solar collectors . As the su n heats the water in t he solar colle ctors the incre ase in temp erature acti vates the circulator. The circulator then mo ves the water from the so lar ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 11

    HOW YOUR WATER HEATER WORKS 11 SINGLE ELEMENT MODELS · Continuous electric ity suppl y This type of conn ection is suited to where the stor age capacit y is less than the normal dail y usage. · Off-Peak electricit y suppl y This type of conne ction will only allow boosting to occur during se t hours. A volume of water suf ficient for the da y’s ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 12

    HOW YOUR WATER HEATER WORKS 12 MANUAL CONTROLS An isolating switch is installed in your electrical me ter box for your solar water heater. Rheem re commends as an opti onal extra a second s witch, called t he Booster Switch, be in stalled in a con venient location such as the kitche n or laundry. This switch should be a normal on/off ma nually oper ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 13

    HOW YOUR WATER HEATER WORKS 13 “ONE SHOT CONT ROL” SWITCH The “One Shot Control” s witch has been special ly de veloped to h elp provid e maximum sa vings with el ectricall y boosted solar water he aters conne cted to a continuous electricit y supply. Power mu st be available to the “One Shot Co ntrol” switch before the b ooster he atin ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 14

    SAVE A SERVICE CALL 14 · · · Check the items b elo w before making a service call. You will be charged fo r attending to any con dition or fault that is not relate d to manufacture or failure of a part. NOT ENOUGH HOT WATER (OR NO HOT W ATER) Insufficient sunligh t Insufficient sunlight due to cloudy weather during su mmer mon ths or lo w solar ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 15

    SAVE A SERVICE CALL 15 · · · · · Air in collecto rs (no solar gain) It is possible und er certain conditions, s uch as when the pi pe work has bee n opened, that air may become trapp ed in the solar collectors. T his will prevent the circulator from moving water arou nd the collector circuit. T he air will need to be purged from the sol ar col ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 16

    SAVE A SERVICE CALL 16 · · · · TEMPER ATURE AND PRESSURE RELIEF V ALVE RUNNING Normal Operation It is normal and desirable t his valve allows a small qu antity of water t o escape during t he hea ting c ycle. However, if it discharges mor e than a bucket full of water in 24 hours, ther e may be another pr oblem. Continuous dribble Try gently ra ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 17

    SAVE A SERVICE CALL 17 · · · · · HIGH ELECTRICITY BILLS W ith the installation of your new solar h ot water system, maximum ele ctrical energ y savings can be achieved with careful planning of hot water usage. Should you at any time, feel your electricit y account is too high, we suggest you check the following points: Is the relief valv e run ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 18

    INSTALL ATION – SOLAR STORAGE TANK 18 The system is su itable for i nstallation, and offers prot ection ag ainst freeze dam age, in areas up to 80 0 metres altitude. T he s ystem has NO W ARRANTY for freez e damage above 80 0 metres a ltitude (refer to “W arranty” on page 40). THIS WATER HE ATER IS NOT SUI T A BLE FOR POOL HE ATING. SOLAR W A ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 19

    INSTALL ATION – SOLAR STORAGE TANK 19 SAFE TRAY It is a requireme nt of the N ational Pl umbing Code AS/NZS 3500.4.2 that for new installations all water heat ers be i nstalled in a safe tray where in the e vent of a leak, property ma y be damaged. Installation of such trays must compl y with Clause 4. 4 and Sub-clauses 1 to 5 of the above mentio ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 20

    INSTALL ATION – SOLAR STORAGE TANK 20 REDUCING HE AT LOSSES We recommend the first 1.5 to 2 m of the hot water line coming out of the water heater be insulated with weatherpro of insulation. In additi on, the insulati on of the hot water line from the water hea ter must compl y with the requirement s of AS/NZS 3400.4.2. ANODE TYPES The correct an ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 21

    INSTALL ATION – SOLAR STORAGE TANK 21 ASSEMBLY OF CO LD W ATER SUPPLY AND SOLAR PIPE CONNE CTIONS Use thread sealing tape or approved t hread sealant o n all fittin gs. All compression fittin gs must use b rass or copper olives. Ensure the air bleed valve is open when filling collectors . HOT WATER OUTL ET Provide a union for disconne ction. Insu ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 22

    INSTALL ATION – SOLAR STORAGE TANK 22 Rheemglas Single Element Twin Element Optima Single Element Twin Element 111250 162250 411250 462250 111315 162315 411315 462315 111400 162400 411400 462400 Storage Litres 270 340 423 Boost Top Litres 50 50 90 Bottom Litres 250 315 400 Dimensions A mm 1390 1700 1880 B mm 650 650 690 C mm 695 695 735 D mm 1117 ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 23

    INSTALL ATION – SOLAR STORAGE TANK 23 INDOOR LOCATION OUTDOOR LOC ATION ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 24

    INSTALL ATION – SOLAR CONT ROL UNIT 24 The solar contr ol uni t is desig ned to be mounted o n the side of the solar storage tank, with its locatio n above and of fset from the c old water inlet. T he solar contr ol unit, supplied with a 1.8 metre power cord, requires a 22 0 – 240 V general powe r outlet (GPO) locate d within 1.2 metres of its ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 25

    INSTALL ATION – SOLAR CONT ROL UNIT · Insulate the prefor med pipe (4) with the 28 0 mm long x 12 mm diam insulation (12) and secure with the cabl e ties (14) pro vided · Fit the air bleed valve and non retur n valve assembl y (11) to the solar hot water inlet of the 5 way tee (2). En sure the bleed valve outlet is orie ntated downwards at a sl ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 26

    INSTALL ATION – SOLAR CONT ROL UNIT 26 SUPPLIED IN SOL AR LOLINE CON VERSION KIT 1. Nipple BSP½” X G ½” 2. 5 way tee 4. Preformed pipe DN 15 5. Compression nut 6. Olive 7. Circulator 8. Solar co ntrol unit 9. Screws 10. Cold se nsor probe 11. Air bleed valve and non return valve asse mbly 12. Insulati on 280 mm l ong x 12 mm diam 13. Insula ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 27

    INSTALLATION – SO LAR COLLECTORS SOLAR COLLECTOR LOC ATION Solar collectors must be installed i n a sha de free position an d located as follows: The solar coll ectors are to installed facing toward the e quator (i.e. nort h facing in the sou thern h emisphere and south facing in the northern hemisphere). W here this orie ntation is not practical ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 28

    CONNECTIONS - PLUMBING 28 CONNECTION SIZES · Hot water connecti on: RP¾/2 0. · Cold water connecti on: R¾/2 0. (cold water inlet to t ank: RP¾ /20). · Solar hot (from colle ctor) connecti on: DN15 compression f itting. · Solar cold (to collect or) connectio n: DN15 compression f itting. · Relief valve c onnection: RP ½/15. · Bleed valve c ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 29

    CONNECTIONS - PLUMBING 29 WARNING: Plumber – Be Aware: · The solar cold and hot pi pes between the sol ar storage ta nk and the solar collector s MUS T BE of cop per and full y insulated wi th Armafle x insulation or similar ( minimum thick ness 10 mm). · The insulation m ust be weatherproof if exposed and fitted up to the connections on both t ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 30

    CONNECTIONS - PLUMBING 30 RELIEF VALVE The T emperature and Press ure Relief valve must be fitt ed bef ore the water heate r is operated. Before fitting th e relief valve, make sure the probe has not been ben t. Seal the thread with T eflon tape - never hemp. Make sure the tape does n ot hang over the end of th e thread. Screw the valve int o the c ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 31

    CONNECTIONS - PLUMBING 31 EXPANSION CONT ROL V A LVE Local regulations ma y make it m andatory to i nstall a n expansio n control valve (ECV) in t he cold water sup ply line. In oth er areas ECVs are not require d unless the satur ation inde x is gre ater than + 0.4 (refer to “W ater Supplies” on page 38). Ho wever, they ma y be needed in corro ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 32

    CONNECTIONS - EL ECTRICAL 32 The power suppl y must not be turne d on until the solar stor age tank is fil led with water, and a satisfactor y megger reading is obtained. T he solar storag e tank with an electric boos ter heating unit is designed for dir ect connection to a 240 V AC 50 Hz m ains po wer suppl y with an isolating s witch installed at ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 33

    CONNECTIONS - EL ECTRICAL 33 MANUAL CONTROLS A manual switch ca n be installed in the power supply circui t to the solar storage tank. The on/off booster s witch can be installed with a single element mod el connected to eit her a conti nuous or an Off-Peak electricit y supply, or with a t win element model to control the bott om heating unit conne ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 34

    COMMISSIONING 34 TO FILL AND TURN ON THE W ATER HE ATER The power suppl y to the solar st orage tank a nd solar con trol unit must not be switched on until th e water heater is filled with water and a satisfact ory megger reading is obtaine d. Open all of the hot water taps i n the hous e (don’t for get the sh ower). Open the cold water isolation ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 35

    COMMISSIONING 35 TO TURN OFF THE WATER HE ATER If it is necessar y to turn off the water hea ter on completio n of the installation , such as on a building sit e or where the premis es is vacant, th en: · Close the cold water isolatio n valve at the inlet to the water heater. · Switch off the electri cal supply at th e isolating s witch to the so ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 36

    DRAINING THE SOL AR COL LECTORS 36 · · · · · To drain the s olar collectors a nd the sol ar hot and cold pipe: · Turn off the water h eater (ref er to “To T urn Off the W ater Heater” on p age 35). · Using a flat bladed scre w driver, open the bleed valve fitted adjacent to th e 5 w ay tee at the c old water inl et of the water hea ter ( ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 37

    37 ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 38

    WATER SUPPLIES 38 Your R heem water he ater is man ufactured t o suit the w ater condit ions of m ost Australian metropoli tan suppli es. Howev er, there are some k nown w ater supplies whi ch can have detriment al effects on the water h eater an d its opera tion and/or life expectancy. I f you are unsure o f your w ater quality , you can obt ain i ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 39

    RHEEM SOLAR WATER HEATER WARRANTY - AUSTRALIA ONLY - 39 WARRANTY CONDITIONS 1. This warranty is appl icable only to water heaters manufactured from 1 st Augus t 2002. 2. The water heater must be ins talled in acc ordance with the Rheem water h eater ins tallation i nstructions, supplied wi th the water heater, an d in accord ance with all relev ant ...

  • Rheem Solar Loline Conversion Kit Electric Wter Heater - page 40

    RHEEM SOLAR WATER HEATER WARRANTY - AUSTRALIA ONLY - 40 Rheem will: a) Repai r or, i f necess ary re place any R heem wat er heate r; or b) Repl ace any com ponent (or, i f necessa ry, arran ge t he install ation of a n ew wat er heate r), which fa lls within the Warranty Per iods spec ified below, in accordan ce with and sub ject to the followi ng ...

Fabricant Rheem Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilRheem Solar Loline Conversion Kit Electric Wter Heater peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Rheem
- manuels d’utilisations Solar Loline Conversion Kit Electric Wter Heater
- fiches produit Rheem
- dépliants
- ou étiquettes-énergie Rheem Solar Loline Conversion Kit Electric Wter Heater
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Rheem Solar Loline Conversion Kit Electric Wter Heater.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Rheem Solar Loline Conversion Kit Electric Wter Heater, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Rheem Solar Loline Conversion Kit Electric Wter Heater. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Rheem Solar Loline Conversion Kit Electric Wter Heater.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Rheem Solar Loline Conversion Kit Electric Wter Heater, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Rheem Solar Loline Conversion Kit Electric Wter Heater par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Rheem Solar Loline Conversion Kit Electric Wter Heater.

Le manuel d’utilisation complet Rheem, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Rheem Solar Loline Conversion Kit Electric Wter Heater - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Rheem Solar Loline Conversion Kit Electric Wter Heater, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRheem Solar Loline Conversion Kit Electric Wter Heater qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Rheem Solar Loline Conversion Kit Electric Wter Heater - qui devraient nous aider dans les premières étapes lors de l'utilisation Rheem Solar Loline Conversion Kit Electric Wter Heater
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Rheem Solar Loline Conversion Kit Electric Wter Heater
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Rheem Solar Loline Conversion Kit Electric Wter Heater dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Rheem Solar Loline Conversion Kit Electric Wter Heater?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Rheem Solar Loline Conversion Kit Electric Wter Heater, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Rheem Solar Loline Conversion Kit Electric Wter Heater il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)