    SVM178-B April, 201 1 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation . . . and thoughtful operation on your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WITHOUT READ- ING THIS MANUAL AND THE SAFETY PRECAU ...

  • Lincoln Electric VANTAGE SVM178-B - page 2

    V ANT AGE® 500 SAFETY i i FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b.Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. _____________________ ...

  • Lincoln Electric VANTAGE SVM178-B - page 3

    V ANT AGE® 500 SAFETY ii ii FUMES AND GASES can be dangerous. 5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep fumes and gases away from the breathing zone. When welding with electrodes which req ...

  • Lincoln Electric VANTAGE SVM178-B - page 4

    V ANT AGE® 500 SAFETY iii iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’s recommendations. 8.c. Ground the equipment in accordance wit ...

  • Lincoln Electric VANTAGE SVM178-B - page 5

    V ANT AGE® 500 SAFETY iv iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a ...

  • Lincoln Electric VANTAGE SVM178-B - page 6

    V ANT AGE® 500 SAFETY Electromagnetic Compatibility (EMC) Confor mance P roducts displaying the CE mark are in conformity with European Community Council Directive of 1 5 Dec 2004 on the appro ximation of the laws of the Member Stat es relating to electromagnetic compatibilit y , 2004/1 08/EC . It was manuf actured in conformit y with a national s ...

  • Lincoln Electric VANTAGE SVM178-B - page 7

    V ANT AGE® 500 SAFETY Electromagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surr ounding ar ea ma y ext end bey ond the boundar ies of the premises. Methods of Reducing Emissions Mains Supply W elding equipment should be con ...

  • Lincoln Electric VANTAGE SVM178-B - page 8

    - MASTER T ABLE OF CONTENTS FOR ALL SECTIONS - I I V ANT AGE® 500 Page Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i-iv Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 9

    T ABLE OF CONTENTS - INST ALLA TION SECTION A1.1 A1.1 V ANT AGE® 500 Installation - V ANT AGE® 500 Deutz F3L912 (Code 10995) T echnical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A1.2 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 10

    INST ALLA TION A1.2 A1.2 V ANT AGE® 500 TECHNICAL SPECIFICA TIONS - V antage 500® DEUTZ (K2271-1) INPUT - DIESEL ENGINE Make /Model Description Speed (RPM) Displacement Starting Capacities System Deutz 3 cylinder High Idle 1900 173 cu. in 12VDC battery Fuel F3L 912 44HP (33 kw) (2.83L) & Starter (25 US gal Diesel Engine @ 1800 RPM Full Load 1 ...

  • Lincoln Electric VANTAGE SVM178-B - page 11

    INST ALLA TION A1.3 A1.3 V ANT AGE® 500 Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions, detailed engine starting, operating and ma ...

  • Lincoln Electric VANTAGE SVM178-B - page 12

    INST ALLA TION A1.4 A1.4 V ANT AGE® 500 LIFTING The V antage® 500 lift bale should be used to lift the machine. The V antage® 500 is shipped with the lift bale retracted. Before attempting to lift the V antage® 500, secure the lift bale in a raised position. Secure the lift bale as follows: a. Open the engine compartment door . b. Locate the tw ...

  • Lincoln Electric VANTAGE SVM178-B - page 13

    INST ALLA TION A1.5 A1.5 V ANT AGE® 500 PRE-OPERA TION ENGINE SERVICE READ the engine operating and maintenance instruc- tions supplied with this machine. • Keep hands away from the engine muffler or HOT engine parts. • Stop engine and allow to cool before fueling. • Do not smoke when fueling. • Fill fuel tank at a moderate rate and do n ...

  • Lincoln Electric VANTAGE SVM178-B - page 14

    INST ALLA TION A1.6 A1.6 V ANT AGE® 500 IMPORT ANT : T o prevent ELECTRICAL DAMAGE WHEN: a) Installing new batteries b) Using a booster Use correct polarity — Negative Ground. The V antage® 500 is shipped with the negative battery cable disconnected. Before you operate the machine, make sure the Engine Switch is in the OFF position and attach t ...

  • Lincoln Electric VANTAGE SVM178-B - page 15

    INST ALLA TION A1.7 A1.7 V ANT AGE® 500 WELDING OUTPUT CABLES With the engine off, route the electrode and work cables through the strain relief bracket provided on the front of the base and connect to the terminals provided. These connections should be checked periodically and tightened if necessary . Listed in T able A1.1 are copper cable sizes ...

  • Lincoln Electric VANTAGE SVM178-B - page 16

    INST ALLA TION A1.8 A1.8 V ANT AGE® 500 Figure A1.1 Connection of the V antage® 500 to Premises Wiring 1. Install the double-pole, double-throw switch between the power company meter and the premises disconnect. Switch rating must be the same as or greater than the customer ’s premises disconnect and service over cur- rent protection. 2. T ake ...

  • Lincoln Electric VANTAGE SVM178-B - page 17

    T ABLE OF CONTENTS - OPERA TION SECTION B1.1 B1.1 V ANT AGE® 500 Operation - V ANT AGE® 500 Deutz F3L912 (Code 10995) Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B1.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 18

    OPERA TION B1.2 B1.2 V ANT AGE® 500 OPERA TING INSTRUCTIONS Read and understand this entire section before oper- ating your V antage® 500. SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions: detailed e ...

  • Lincoln Electric VANTAGE SVM178-B - page 19

    OPERA TION B1.3 B1.3 V ANT AGE® 500 RECOMMENDED APPLICA TIONS WELDER The V antage® 500 provides excellent constant current DC welding output for stick (SMA W) and TIG welding. The V antage® 500 also provides excellent constant voltage DC welding output for MIG (GMA W) and Innershield (FCA W) welding. GENERA TOR The V antage® 500 provides smooth ...

  • Lincoln Electric VANTAGE SVM178-B - page 20

    OPERA TION B1.4 B1.4 V ANT AGE® 500 ENGINE CONTROLS (Items 1 through 9) 1 . R UN ST O P SW IT CH T oggling the switch to the RUN position energizes the fuel solenoid for approximately 30 seconds. The engine must be started within that time or the fuel solenoid will denergize, and the switch must be tog- gled to reset the timer . 2. ST ART PUSHBUTT ...

  • Lincoln Electric VANTAGE SVM178-B - page 21

    OPERA TION 6. OIL PRESSURE GAUGE The gauge displays the engine oil pressure when the engine is running. 7. ENGINE PROTECTION  The yellow engine protection light remains off with proper oil pressure and under normal operating tem- peratures. If the light turns on, the engine protection system will stop the engine. Check for proper oil and coolan ...

  • Lincoln Electric VANTAGE SVM178-B - page 22

    OPERA TION 13. WELDING TERMINALS SWITCH In the WELD TERMINALS ON position, the output is electrically hot all the time. In the REMOTEL Y CON- TROLLED position, the output is controlled by a wire feeder or amptrol device, and is electrically off until a remote switch is depressed. 14. WIRE FEEDER VOL TMETER SWITCH: Matches the polarity o ...

  • Lincoln Electric VANTAGE SVM178-B - page 23

    OPERA TION ENGINE OPERA TION ST ARTING THE ENGINE 1. Open the engine compartment door and check that the fuel shutoff valve is in the open position (lever to be in line with the hose). 2. Check for proper oil level and coolant level. Close engine compartment door . 3. Remove all plugs connected to the AC power recep- tacles. 4. Set IDLER switch to ...

  • Lincoln Electric VANTAGE SVM178-B - page 24

    WELDER OPERA TION DUTY CYCLE Duty Cycle is the the ratio of the uninterrupted on-load duration to 10 minutes. The total time period of one complete on-load and no-load cycle is 10 minutes. For example, in the case of a 60% duty cycle, load is applied continuously for 6 minutes followed by a no- load period of 4 minutes. STICK WELDING MODE The V ant ...

  • Lincoln Electric VANTAGE SVM178-B - page 25

    OPERA TION B1.9 B1.9 V ANT AGE® 500 V ANT AGE 500 SETTINGS WHEN USING THE K799 HI-FREQ UNIT • Set the WELD MODE switch to the 20-250 setting (TIG). • Set the IDLER switch to the HIGH position. • Set the WELDING TERMINALS switch to the WELD TERMINALS ON position. This will close the solid state contactor and provide an always “hot” electr ...

  • Lincoln Electric VANTAGE SVM178-B - page 26

    OPERA TION B1.10 B1.10 V ANT AGE® 500 WIRE FEED (CONST ANT VOL T AGE) WELDING Connect a wire feeder to the V antage® 500 and set welder controls according to the instructions listed ear- lier in this section. See the operator ’s manual for the wire feeder or the “ Diagrams ” section of this manual for connecting instructions of various Linc ...

  • Lincoln Electric VANTAGE SVM178-B - page 27

    OPERA TION B1.11 B1.11 V ANT AGE® 500 T ABLE B1.4 – V ANT AGE 500 EXTENSION CORD LENGTH RECOMMENDA TIONS Current (Amps) 15 15 20 20 25 30 38 50 V oltage (V olts) 120 240 120 240 240 240 240 240 Load (W atts) 1800 3600 2400 48010 6000 7200 9000 12000 30 60 (9) (18) 40 75 30 60 (12) (23) (9) (18) 75 150 50 100 90 75 (23) (46) (15) (30) (27) (23) 1 ...

  • Lincoln Electric VANTAGE SVM178-B - page 28

    NOTES B1.12 B1.12 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 29

    T ABLE OF CONTENTS - ACCESSORIES SECTION C1.1 C1.1 V ANT AGE® 500 Accessories - V ANT AGE® 500 Deutz F3L912 (Code 10995) Options/Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C1.1 Optional Field Installed Accessories . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 30

    ACCESSORIES C1.2 C1.2 V ANT AGE® 500 K802N POWER PLUG KIT - Provides four 120V plugs rated at 20 amps each and one dual voltage, full KV A plug rated at 120/240V , 50 amps. The 20 amp/120V plug may not be compatible with NEMA common household receptacles. K802R POWER PLUG KIT - Provides four 120V plugs rated 15 amps each and one dual voltage, fu ...

  • Lincoln Electric VANTAGE SVM178-B - page 31

    ACCESSORIES C1.3 C1.3 V ANT AGE® 500 TIG OPTIONS K1783-9 PT A-26V TIG T orch Air Cooled 200 amp torch (2 piece) equipped with valve for gas flow control. 25 ft. (7.6m) length. KP509 Magnum Parts Kit for PT A-26V TIG T orch Magnum Parts Kit provides all the torch accessories you need to start welding. Parts kit provides collets, collet bodies, a ...

  • Lincoln Electric VANTAGE SVM178-B - page 32

    NOTES C1.4 C1.4 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 33

    T ABLE OF CONTENTS - MAINTENANCE SECTION D1.1 D1.1 V ANT AGE® 500 Maintenance - V ANT AGE® 500 Deutz F3L912 (Code 10995) Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D1.2 Routine and Periodic Maintenance . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 34

    MAINTENANCE D1.2 D1.2 V ANT AGE® 500 SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • T urn the engine off before working inside the machine. • Remove covers or guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is com- plete. • If cove ...

  • Lincoln Electric VANTAGE SVM178-B - page 35

    MAINTENANCE D1.3 D1.3 V ANT AGE® 500 CHANGE THE OIL FIL TER: Change the oil filter the first time between 25 and 50 hours of operation. Then, under normal operating conditions, change the oil filter after every 250 hours of operation. If the engine is operated under heavy load or in high ambient tem - peratures, change the oil filter more frequent ...

  • Lincoln Electric VANTAGE SVM178-B - page 36

    MAINTENANCE D1.4 D1.4 V ANT AGE® 500 FUEL FIL TERS: When working on the fuel system: • Keep naked lights away , do not smoke • Do not spill fuel The V antage® 500 is equipped with a Fuel Pre- Filter/W ater Separator Assembly located before the lift pump and a Secondary Fuel Filter located after the lift pump and before the fuel injectors. The ...

  • Lincoln Electric VANTAGE SVM178-B - page 37

    MAINTENANCE D1.5 D1.5 V ANT AGE® 500 4. Slide the new element onto the grommet post on the bottom of the filter header until the element no longer easily moves up into the filter header . Now rotate the element (it may take almost 1 full turn) with a slight upward pressure until the element begins to further engage the header . With the prop- er o ...

  • Lincoln Electric VANTAGE SVM178-B - page 38

    MAINTENANCE D1.6 D1.6 V ANT AGE® 500 BLEEDING THE FUEL SYSTEM: In the event the engine is operated until it runs out of fuel, you will need to bleed the fuel system in order to start the engine. Refer to the engine operation manual. AIR FIL TER Excessive air filter restriction will result in reduced engine life. The air filter element is a dry car ...

  • Lincoln Electric VANTAGE SVM178-B - page 39

    MAINTENANCE D1.7 D1.7 V ANT AGE® 500 MAINTENANCE INSTRUCTIONS Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 40

    MAINTENANCE D1.8 D1.8 V ANT AGE® 500 COOLING SYSTEM The cooling system of the Deutz engine needs to be checked and cleaned periodically . Consult the engine Operation Manual for the proper frequency and proce- dure. COOLING BLOWER BEL T : The following procedure should be followed to replace the cooling blower belt: 1. Allow the machine to cool. 2 ...

  • Lincoln Electric VANTAGE SVM178-B - page 41

    MAINTENANCE D1.9 D1.9 V ANT AGE® 500 T ABLE D1.1 DEUTZ ENGINE MAINTENANCE SCHEDULE FREQUENCY MAINTENANCE REQUIRED Daily or Before Starting Engine • Fill fuel tank. •  Check oil level. • Check air cleaner for dirty , loose, or damaged parts. Replace if necessary . • Check air intake and cooling areas, clean as necessary . 1 First 50 Hours ...

  • Lincoln Electric VANTAGE SVM178-B - page 42

    MAINTENANCE D1.10 D1.10 V ANT AGE® 500 BA TTER Y MAINTENANCE GASES FROM BA TTER Y can explode. • Keep sparks, flame, and cigarettes away from battery . BA TTERY ACID can burn eyes and skin. • Wear gloves and eye protection and be careful when working near a bat- tery . Follow the instructions printed on the battery . T o prevent EXPLOSION when ...

  • Lincoln Electric VANTAGE SVM178-B - page 43

    MAINTENANCE D1.11 D1.11 V ANT AGE® 500 WELDER/GENERA TOR MAINTENANCE STORAGE: Store the V antage 500 in clean, dry , pro- tected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air . Do this at least once a week in particularly dirty areas. NAMEPLA TES: Whenever routine maintenance is performed on this machine ...

  • Lincoln Electric VANTAGE SVM178-B - page 44

    MAINTENANCE D1.12 D1.12 V ANT AGE® 500 WARNING 1 2 4 3 5 7 8 6 9 10 OFF FIGURE D1.5 – MAJOR COMPONENT LOCA TIONS 1. CONTROL P ANEL ASSEMBL Y 2. CONTROL BOX & OUTPUT ASSEMBL Y 3. POWER MODULE ASSEMBL Y 4. BASE & LIFT BALE ASSEMBL Y 5. FUEL T ANK & MOUNTING 6. ENGINE ASSEMBL Y 7. GENERA TOR 8. SOLENOID ASSEMBL Y 9. CASEBACK 10. CASE TO ...

  • Lincoln Electric VANTAGE SVM178-B - page 45

    T ABLE OF CONTENTS - INST ALLA TION SECTION A2.1 A2.1 V ANT AGE® 500 Installation - V ANT AGE® 500 Deutz F4L201 1 (Codes 1 1 180,1 1415) T echnical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A2.2 Safety Precautions . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 46

    INST ALLA TION A2.2 A2.2 V ANT AGE® 500 TECHNICAL SPECIFICA TIONS - V ANT AGE 500 DEUTZ (K2405-1) INPUT - DIESEL ENGINE Make /Model Description Speed (RPM) Displacement Starting Capacities System DEUTZ 4 cylinder High Idle 1890 190 cu. in 12VDC battery Fuel F4L201 1 48HP (36 kw) Low Idle 1425 (3.1L) & Starter 25 US gal. Diesel Engine @ 1800 RP ...

  • Lincoln Electric VANTAGE SVM178-B - page 47

    INST ALLA TION A2.3 A2.3 V ANT AGE® 500 Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions, detailed engine starting, operating and m ...

  • Lincoln Electric VANTAGE SVM178-B - page 48

    INST ALLA TION A2.4 A2.4 V ANT AGE® 500 LIFTING The V antage lift bale should be used to lift the machine. The V antage is shipped with the lift bale retracted. Before attempting to lift the V antage, secure the lift bale in a raised position. Secure the lift bale as follows: a. Open the engine compartment door . b. Locate the two access holes on ...

  • Lincoln Electric VANTAGE SVM178-B - page 49

    INST ALLA TION A2.5 A2.5 V ANT AGE® 500 PRE-OPERA TION ENGINE SERVICE READ the engine operating and maintenance instruc- tions supplied with this machine. • Keep hands away from the engine muffler or HOT engine parts. • Stop engine and allow to cool before fueling. • Do not smoke when fueling. • Fill fuel tank at a moderate rate and do n ...

  • Lincoln Electric VANTAGE SVM178-B - page 50

    INST ALLA TION A2.6 A2.6 V ANT AGE® 500 IMPORT ANT : T o prevent ELECTRICAL DAMAGE WHEN: a) Installing new batteries b) Using a booster Use correct polarity — Negative Ground. The V antage is shipped with the negative battery cable disconnected. Before you operate the machine, make sure the Engine Switch is in the OFF position and attach the dis ...

  • Lincoln Electric VANTAGE SVM178-B - page 51

    INST ALLA TION A2.7 A2.7 V ANT AGE® 500 WELDING OUTPUT CABLES With the engine off, route the electrode and work cables through the strain relief bracket provided on the front of the base and connect to the terminals provided. These connections should be checked periodically and tightened if necessary . Listed in T able A2.1 are copper cable sizes ...

  • Lincoln Electric VANTAGE SVM178-B - page 52

    INST ALLA TION A2.8 A2.8 V ANT AGE® 500 Figure A2.1 Connection of the V antage to Premises Wiring 1. Install the double-pole, double-throw switch between the power company meter and the premises disconnect. Switch rating must be the same or greater than the cus- tomer ’s premises disconnect and service over current protection. 2. T ake necessary ...

  • Lincoln Electric VANTAGE SVM178-B - page 53

    T ABLE OF CONTENTS - OPERA TION SECTION B2.1 B2.1 V ANT AGE® 500 Operation - V ANT AGE® 500 Deutz F4L201 1 (Codes 1 1 180,1 1415) Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B2.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 54

    OPERA TION B2.2 B2.2 V ANT AGE® 500 OPERA TING INSTRUCTIONS Read and understand this entire section before oper- ating your V antage 500. SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions: detailed eng ...

  • Lincoln Electric VANTAGE SVM178-B - page 55

    OPERA TION B2.3 B2.3 V ANT AGE® 500 RECOMMENDED APPLICA TIONS WELDER The V antage 500 provides excellent constant current DC welding output for stick (SMA W) and TIG welding. The V antage 500 also provides excellent constant volt- age DC welding output for MIG (GMAW) and Innershield (FCA W) welding. GENERA TOR The V antage 500 provides smooth 120/ ...

  • Lincoln Electric VANTAGE SVM178-B - page 56

    OPERA TION B2.4 B2.4 V ANT AGE® 500 ENGINE CONTROLS (Items 1 through 9) 1 . R UN ST O P SW IT CH T oggling the switch to the RUN position energizes the fuel solenoid for approximately 30 seconds. The engine must be started within that time or the fuel solenoid will denergize, and the switch must be tog- gled to reset the timer . 2. ST ART PUSHBUTT ...

  • Lincoln Electric VANTAGE SVM178-B - page 57

    OPERA TION B2.5 B2.5 V ANT AGE® 500 6. OIL PRESSURE GAUGE The gauge displays the engine oil pressure when the engine is running. 7. ENGINE PROTECTION  The yellow engine protection light remains off with proper oil pressure and under normal operating tem- peratures. If the light turns on, the engine protection system will stop the engine. Check ...

  • Lincoln Electric VANTAGE SVM178-B - page 58

    OPERA TION B2.6 B2.6 V ANT AGE® 500 WELDING CONTROLS (Items 10 through 19) 10. OUTPUT CONTROL: The OUTPUT dial is used to preset the output voltage or current as displayed on the digital meters for the four welding modes. When in the CC-STICK, DOWN- HILL PIPE or CV -WIRE modes and when a remote control is connected to the 6-Pin or 14-Pin Connector ...

  • Lincoln Electric VANTAGE SVM178-B - page 59

    OPERA TION B2.7 B2.7 V ANT AGE® 500 20. CIRCUIT BREAKERS These circuit breakers provide separate overload current protection for each 120V circuit at the 240V single phase receptacle, each 120V single phase receptacle, the 240V three phase receptacle, the 120V AC in the 14-Pin connector , the 42V AC in the 14-Pin connector and battery circuit over ...

  • Lincoln Electric VANTAGE SVM178-B - page 60

    WELDER OPERA TION DUTY CYCLE Duty Cycle is the the ratio of the uninterrupted on-load duration to 10 minutes. The total time period of one complete on-load and no-load cycle is 10 minutes. For example, in the case of a 60% duty cycle, load is applied continuously for 6 minutes followed by a no- load period of 4 minutes. STICK WELDING MODE The V ant ...

  • Lincoln Electric VANTAGE SVM178-B - page 61

    OPERA TION B2.9 B2.9 V ANT AGE® 500 V ANT AGE 500 SETTINGS WHEN USING THE K799 HI-FREQ UNIT • Set the WELD MODE switch to the 20-250 setting (TIG). • Set the IDLER switch to the HIGH position. • Set the WELDING TERMINALS switch to the WELD TERMINALS ON position. This will close the solid state contactor and provide an always “hot” electr ...

  • Lincoln Electric VANTAGE SVM178-B - page 62

    OPERA TION B2.10 B2.10 V ANT AGE® 500 WIRE FEED (CONST ANT VOL T AGE) WELDING Connect a wire feeder to the V antage 500 and set welder controls according to the instructions listed ear- lier in this section. See the operator ’s manual for the wire feeder or the “Diagrams ” section of this manual for connecting instructions of various Lincoln ...

  • Lincoln Electric VANTAGE SVM178-B - page 63

    OPERA TION B2.11 B2.11 V ANT AGE® 500 T ABLE B2.4 – V ANT AGE 500 EXTENSION CORD LENGTH RECOMMENDA TIONS Current (Amps) 15 15 20 20 25 30 38 50 V oltage (V olts) 120 240 120 240 240 240 240 240 Load (W atts) 1800 3600 2400 48010 6000 7200 9000 12000 30 60 (9) (18) 40 75 30 60 (12) (23) (9) (18) 75 150 50 100 90 75 (23) (46) (15) (30) (27) (23) 1 ...

  • Lincoln Electric VANTAGE SVM178-B - page 64

    NOTES B2.12 B2.12 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 65

    T ABLE OF CONTENTS - ACCESSORIES SECTION C2.1 C2.1 V ANT AGE® 500 Accessories - V ANT AGE® 500 Deutz F4L201 1 (Codes 1 1 180, 1 1415) Options/Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C2.2 Optional Field Installed Accessories . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 66

    ACCESSORIES C2.2 C2.2 V ANT AGE® 500 K802N POWER PLUG KIT - Provides four 120V plugs rated at 20 amps each and one dual voltage, full KV A plug rated at 120/240V , 50 amps. 120V plug may not be compatible with NEMA common household receptacles. K802R POWER PLUG KIT - Provides four 120V plugs rated 15 amps each and one dual voltage, full KV A plu ...

  • Lincoln Electric VANTAGE SVM178-B - page 67

    ACCESSORIES C2.3 C2.3 V ANT AGE® 500 TIG OPTIONS K1783-9 PT A-26V TIG T orch Air Cooled 200 amp torch (2 piece) equipped with valve for gas flow control. 25 ft. (7.6m) length. KP509 Magnum Parts Kit for PT A-26V TIG T orch Magnum Parts Kit provides all the torch accessories you need to start welding. Parts kit provides collets, collet bodies, a ...

  • Lincoln Electric VANTAGE SVM178-B - page 68

    NOTES C2.4 C2.4 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 69

    T ABLE OF CONTENTS - MAINTENANCE SECTION D2.1 D2.1 V ANT AGE® 500 Maintenance - V ANT AGE® 500 Deutz F4L201 1 (Codes 1 1 180,1 1415) Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D2.2 Routine and Periodic Maintenance . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 70

    MAINTENANCE D2.2 D2.2 V ANT AGE® 500 SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • T urn the engine off before working inside the machine. • Remove covers or guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is com- plete. • If cove ...

  • Lincoln Electric VANTAGE SVM178-B - page 71

    MAINTENANCE D2.3 D2.3 V ANT AGE® 500 CHANGE THE OIL FIL TER Change the oil filter the first time between 25 and 50 hours of operation. Then, under normal operating con- ditions, change the oil filter after every 250 hours of operation. If the engine is operated under heavy load or in high ambient tem peratures, change the oil filter more frequentl ...

  • Lincoln Electric VANTAGE SVM178-B - page 72

    MAINTENANCE D2.4 D2.4 V ANT AGE® 500 FUEL FIL TERS When working on the fuel system • Keep naked lights away , do not smoke ! • Do not spill fuel ! ------------------------------------------------------------------------ The V ANT AGE 500 DEUTZ is equipped with a Fuel Filter/W ater Separator located after the lift pump and before fuel injectors ...

  • Lincoln Electric VANTAGE SVM178-B - page 73

    MAINTENANCE D2.5 D2.5 V ANT AGE® 500 AIR FIL TER: Excessive air filter restriction will result in reduced engine life. The air filter element is a dry cartridge type. It can be cleaned and reused. However , damaged elements should not be reused. Stop engine after 100 hours of running time and clean filter element. Replace the filter if necessary . ...

  • Lincoln Electric VANTAGE SVM178-B - page 74

    MAINTENANCE D2.6 D2.6 V ANT AGE® 500 MAINTENANCE INSTRUCTIONS Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 75

    MAINTENANCE D2.7 D2.7 V ANT AGE® 500 COOLING SYSTEM The cooling system of the Deutz engine needs to be checked and cleaned periodically . Consult the engine Operation Manual for the proper frequency and proce- dures. COOLING BLOWER BEL T : The following procedure should be followed to replace the cooling blower belt: 1. Allow the machine to cool. ...

  • Lincoln Electric VANTAGE SVM178-B - page 76

    MAINTENANCE D2.8 D2.8 V ANT AGE® 500 WELDER/GENERA TOR MAINTENANCE STORAGE: Store the V antage 500 in clean, dry , pro- tected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air . Do this at least once a week in particularly dirty areas. NAMEPLA TES: Whenever routine maintenance is per- formed on this machine ...

  • Lincoln Electric VANTAGE SVM178-B - page 77

    MAINTENANCE D2.9 D2.9 V ANT AGE® 500 BA TTER Y MAINTENANCE GASES FROM BA TTER Y can explode. • Keep sparks, flame, and cigarettes away from battery . BA TTERY ACID can burn eyes and skin. • Wear gloves and eye protection and be careful when working near a bat- tery . Follow the instructions printed on the battery . T o prevent EXPLOSION when: ...

  • Lincoln Electric VANTAGE SVM178-B - page 78

    MAINTENANCE D2.10 D2.10 V ANT AGE® 500 WARNING W ARNING 1 1 2 2 4 4 6 6 3 3 5 5 7 7 10 10 9 9 FIGURE D2.6 – MAJOR COMPONENT LOCA TIONS 1. CONTROL P ANEL ASSEMBL Y 2. CONTROL BOX & OUTPUT ASSEMBL Y 3. POWER MODULE ASSEMBL Y 4. BASE & LIFT BALE ASSEMBL Y 5. FUEL T ANK & MOUNTING 6. ENGINE ASSEMBL Y 7. GENERA TOR 8. SOLENOID ASSEMBL Y 9 ...

  • Lincoln Electric VANTAGE SVM178-B - page 79

    T ABLE OF CONTENTS - INST ALLA TION SECTION A3.1 A3.1 V ANT AGE® 500 Installation - V ANT AGE® 500 Deutz D201 1L4i (Code1 1468) T echnical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A3.2 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 80

    INST ALLA TION A3.2 A3.2 V ANT AGE® 500 TECHNICAL SPECIFICA TIONS - V ANT AGE® 500 DEUTZ (K2405-2) INPUT - DIESEL ENGINE Make /Model Description Speed (RPM) Displacement Starting Capacities System DEUTZ 4 cylinder High Idle 1890 190 cu. in 12VDC battery Fuel D 201 1 L4i 48HP (36 kw) Low Idle 1425 (3.1L) & Starter 25 US gal. Diesel Engine @ 18 ...

  • Lincoln Electric VANTAGE SVM178-B - page 81

    INST ALLA TION A3.3 A3.3 V ANT AGE® 500 Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions, detailed engine starting, operating and m ...

  • Lincoln Electric VANTAGE SVM178-B - page 82

    INST ALLA TION A3.4 A3.4 V ANT AGE® 500 LIFTING The V antage lift bale should be used to lift the machine. The V antage is shipped with the lift bale retracted. Before attempting to lift the V antage, secure the lift bale in a raised position. Secure the lift bale as follows: a. Open the engine compartment door . b. Locate the two access holes on ...

  • Lincoln Electric VANTAGE SVM178-B - page 83

    INST ALLA TION A3.5 A3.5 V ANT AGE® 500 PRE-OPERA TION ENGINE SERVICE READ the engine operating and maintenance instruc- tions supplied with this machine. • Keep hands away from the engine muffler or HOT engine parts. • Stop engine and allow to cool before fueling. • Do not smoke when fueling. • Fill fuel tank at a moderate rate and do n ...

  • Lincoln Electric VANTAGE SVM178-B - page 84

    INST ALLA TION A3.6 A3.6 V ANT AGE® 500 IMPORT ANT : T o prevent ELECTRICAL DAMAGE WHEN: a) Installing new batteries b) Using a booster Use correct polarity — Negative Ground. The V antage is shipped with the negative battery cable disconnected. Before you operate the machine, make sure the Engine Switch is in the OFF position and attach the dis ...

  • Lincoln Electric VANTAGE SVM178-B - page 85

    INST ALLA TION A3.7 A3.7 V ANT AGE® 500 WELDING OUTPUT CABLES With the engine off, route the electrode and work cables through the strain relief bracket provided on the front of the base and connect to the terminals provided. These connections should be checked periodically and tightened if necessary . Listed in T able A3.1 are copper cable sizes ...

  • Lincoln Electric VANTAGE SVM178-B - page 86

    INST ALLA TION A3.8 A3.8 V ANT AGE® 500 Figure A3.1 Connection of the V antage to Premises Wiring 1. Install the double-pole, double-throw switch between the power company meter and the premises disconnect. Switch rating must be the same or greater than the cus- tomer ’s premises disconnect and service over current protection. 2. T ake necessary ...

  • Lincoln Electric VANTAGE SVM178-B - page 87

    T ABLE OF CONTENTS - OPERA TION SECTION B3.1 B3.1 V ANT AGE® 500 Operation - V ANT AGE® 500 Deutz D201 1L4i (Code 1 1468) Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B3.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 88

    OPERA TION B3.2 B3.2 V ANT AGE® 500 OPERA TING INSTRUCTIONS Read and understand this entire section before oper- ating your V antage 500. SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions: detailed eng ...

  • Lincoln Electric VANTAGE SVM178-B - page 89

    OPERA TION B3.3 B3.3 V ANT AGE® 500 RECOMMENDED APPLICA TIONS WELDER The V antage 500 provides excellent constant current DC welding output for stick (SMA W) and TIG welding. The V antage 500 also provides excellent constant volt- age DC welding output for MIG (GMAW) and Innershield (FCA W) welding. GENERA TOR The V antage 500 provides smooth 120/ ...

  • Lincoln Electric VANTAGE SVM178-B - page 90

    OPERA TION B3.4 B3.4 V ANT AGE® 500 ENGINE CONTROLS (Items 1 through 9) 1 . R UN ST O P SW IT CH T oggling the switch to the RUN position energizes the fuel solenoid for approximately 30 seconds. The engine must be started within that time or the fuel solenoid will denergize, and the switch must be tog- gled to reset the timer . 2. ST ART PUSHBUTT ...

  • Lincoln Electric VANTAGE SVM178-B - page 91

    OPERA TION B3.5 B3.5 V ANT AGE® 500 6. OIL PRESSURE GAUGE The gauge displays the engine oil pressure when the engine is running. 7. ENGINE PROTECTION  The yellow engine protection light remains off with proper oil pressure and under normal operating tem- peratures. If the light turns on, the engine protection system will stop the engine. Check ...

  • Lincoln Electric VANTAGE SVM178-B - page 92

    OPERA TION B3.6 B3.6 V ANT AGE® 500 WELDING CONTROLS (Items 10 through 19) 10. OUTPUT CONTROL: The OUTPUT dial is used to preset the output voltage or current as displayed on the digital meters for the four welding modes. When in the CC-STICK, DOWN- HILL PIPE or CV -WIRE modes and when a remote control is connected to the 6-Pin or 14-Pin Connector ...

  • Lincoln Electric VANTAGE SVM178-B - page 93

    OPERA TION B3.7 B3.7 V ANT AGE® 500 20. CIRCUIT BREAKERS These circuit breakers provide separate overload current protection for each 120V circuit at the 240V single phase receptacle, each 120V single phase receptacle, the 240V three phase receptacle, the 120V AC in the 14-Pin connector , the 42V AC in the 14-Pin connector and battery circuit over ...

  • Lincoln Electric VANTAGE SVM178-B - page 94

    OPERA TION B3.8 B3.8 V ANT AGE® 500 WELDER OPERA TION DUTY CYCLE Duty Cycle is the the ratio of the uninterrupted on-load duration to 10 minutes. The total time period of one complete on-load and no-load cycle is 10 minutes. For example, in the case of a 60% duty cycle, load is applied continuously for 6 minutes followed by a no- load period of 4 ...

  • Lincoln Electric VANTAGE SVM178-B - page 95

    OPERA TION B3.9 B3.9 V ANT AGE® 500 V ANT AGE 500 SETTINGS WHEN USING THE K799 HI-FREQ UNIT • Set the WELD MODE switch to the 20-250 setting (TIG). • Set the IDLER switch to the HIGH position. • Set the WELDING TERMINALS switch to the WELD TERMINALS ON position. This will close the solid state contactor and provide an always “hot” electr ...

  • Lincoln Electric VANTAGE SVM178-B - page 96

    OPERA TION B3.10 B3.10 V ANT AGE® 500 WIRE FEED (CONST ANT VOL T AGE) WELDING Connect a wire feeder to the V antage 500 and set welder controls according to the instructions listed ear- lier in this section. See the operator ’s manual for the wire feeder or the “Diagrams ” section of this manual for connecting instructions of various Lincoln ...

  • Lincoln Electric VANTAGE SVM178-B - page 97

    OPERA TION B3.11 B3.11 V ANT AGE® 500 T ABLE B3.4 – V ANT AGE 500 EXTENSION CORD LENGTH RECOMMENDA TIONS Current (Amps) 15 15 20 20 25 30 38 50 V oltage (V olts) 120 240 120 240 240 240 240 240 Load (W atts) 1800 3600 2400 48010 6000 7200 9000 12000 30 60 (9) (18) 40 75 30 60 (12) (23) (9) (18) 75 150 50 100 90 75 (23) (46) (15) (30) (27) (23) 1 ...

  • Lincoln Electric VANTAGE SVM178-B - page 98

    NOTES B3.12 B3.12 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 99

    T ABLE OF CONTENTS - ACCESSORIES SECTION C3.1 C3.1 V ANT AGE® 500 Accessories - V ANT AGE® 500 Deutz F4L201 1 (Codes 1 1 180, 1 1415) Options/Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C3.2 Optional Field Installed Accessories . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 100

    ACCESSORIES C3.2 C3.2 V ANT AGE® 500 K802N POWER PLUG KIT - Provides four 120V plugs rated at 20 amps each and one dual voltage, full KV A plug rated at 120/240V , 50 amps. 120V plug may not be compatible with NEMA common household receptacles. K802R POWER PLUG KIT - Provides four 120V plugs rated 15 amps each and one dual voltage, full KV A plu ...

  • Lincoln Electric VANTAGE SVM178-B - page 101

    ACCESSORIES C3.3 C3.3 V ANT AGE® 500 TIG OPTIONS K1783-9 PT A-26V TIG T orch Air Cooled 200 amp torch (2 piece) equipped with valve for gas flow control. 25 ft. (7.6m) length. KP509 Magnum Parts Kit for PT A-26V TIG T orch Magnum Parts Kit provides all the torch accessories you need to start welding. Parts kit provides collets, collet bodies, a ...

  • Lincoln Electric VANTAGE SVM178-B - page 102

    NOTES C3.4 C3.4 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 103

    T ABLE OF CONTENTS - MAINTENANCE SECTION D3.1 D3.1 V ANT AGE® 500 Maintenance - V ANT AGE® 500 Deutz D201 1L4i (Codes 1 1468) Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D3.2 Routine and Periodic Maintenance . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 104

    MAINTENANCE D3.2 D3.2 V ANT AGE® 500 SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • T urn the engine off before working inside the machine. • Remove covers or guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is com- plete. • If cove ...

  • Lincoln Electric VANTAGE SVM178-B - page 105

    MAINTENANCE D3.3 D3.3 V ANT AGE® 500 CHANGE THE OIL FIL TER Change the oil filter the first time between 25 and 50 hours of operation. Then, under normal operating con- ditions, change the oil filter after every 250 hours of operation. If the engine is operated under heavy load or in high ambient tem peratures, change the oil filter more frequentl ...

  • Lincoln Electric VANTAGE SVM178-B - page 106

    MAINTENANCE D3.4 D3.4 V ANT AGE® 500 FUEL FIL TERS When working on the fuel system • Keep naked lights away , do not smoke ! • Do not spill fuel ! The V ANT AGE 500 DEUTZ is equipped with a Fuel Filter/W ater Separator located after the lift pump and before fuel injectors.The procedure for changing the fil- ter is as follows. See Figure D3.2 1 ...

  • Lincoln Electric VANTAGE SVM178-B - page 107

    MAINTENANCE D3.5 D3.5 V ANT AGE® 500 AIR FIL TER: Excessive air filter restriction will result in reduced engine life . The air filter element is a dry cartridge type. It can be cleaned and reused. However , damaged elements should not be reused. Stop engine after 100 hours of running time and clean filter element. Replace the filter if necessary ...

  • Lincoln Electric VANTAGE SVM178-B - page 108

    MAINTENANCE D3.6 D3.6 V ANT AGE® 500 MAINTENANCE INSTRUCTIONS Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 109

    MAINTENANCE D3.7 D3.7 V ANT AGE® 500 COOLING SYSTEM The cooling system of the Deutz engine needs to be checked and cleaned periodically . Consult the engine Operation Manual for the proper frequency and proce- dures. COOLING BLOWER BEL T : The following procedure should be followed to replace the cooling blower belt: 1. Allow the machine to cool. ...

  • Lincoln Electric VANTAGE SVM178-B - page 110

    MAINTENANCE D3.8 D3.8 V ANT AGE® 500 WELDER/GENERA TOR MAINTENANCE STORAGE: Store the V antage 500 in clean, dry , pro- tected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air . Do this at least once a week in particularly dirty areas. NAMEPLA TES: Whenever routine maintenance is per- formed on this machine ...

  • Lincoln Electric VANTAGE SVM178-B - page 111

    MAINTENANCE D3.9 D3.9 V ANT AGE® 500 BA TTER Y MAINTENANCE GASES FROM BA TTER Y can explode. • Keep sparks, flame, and cigarettes away from battery . BA TTERY ACID can burn eyes and skin. • Wear gloves and eye protection and be careful when working near a bat- tery . Follow the instructions printed on the battery . T o prevent EXPLOSION when: ...

  • Lincoln Electric VANTAGE SVM178-B - page 112

    MAINTENANCE D3.10 D3.10 V ANT AGE® 500 WARNING W ARNING 1 1 2 2 4 4 6 6 3 3 5 5 7 7 10 10 9 9 FIGURE D2.6 – MAJOR COMPONENT LOCA TIONS 1. CONTROL P ANEL ASSEMBL Y 2. CONTROL BOX & OUTPUT ASSEMBL Y 3. POWER MODULE ASSEMBL Y 4. BASE & LIFT BALE ASSEMBL Y 5. FUEL T ANK & MOUNTING 6. ENGINE ASSEMBL Y 7. GENERA TOR 8. SOLENOID ASSEMBL Y 9 ...

  • Lincoln Electric VANTAGE SVM178-B - page 113

    T ABLE OF CONTENTS - INST ALLA TION SECTION A4.1 A4.1 V ANT AGE® 500 Installation - V ANT AGE® 500 Cummins B3.3 (Code 10996) T echnical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A4.2 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 114

    INST ALLA TION A4.2 A4.2 V ANT AGE® 500 TECHNICAL SPECIFICA TIONS - V antage 500 CUMMINS (K2272-1) INPUT - DIESEL ENGINE Make /Model Description Speed (RPM) Displacement Starting Capacities System Cummins 4 cylinder High Idle 1900 199 cu. in 12VDC battery Fuel B3.3 56HP (42 kw) Low Idle 1425 (3.3L) & Starter (25 US gal) Diesel Engine @ 1800 RP ...

  • Lincoln Electric VANTAGE SVM178-B - page 115

    INST ALLA TION A4.3 A4.3 V ANT AGE® 500 Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions, detailed engine starting, operating and m ...

  • Lincoln Electric VANTAGE SVM178-B - page 116

    INST ALLA TION A4.4 A4.4 V ANT AGE® 500 LIFTING The V antage lift bale should be used to lift the machine. The V antage is shipped with the lift bale retracted. Before attempting to lift the V antage, secure the lift bale in a raised position. Secure the lift bale as follows: a. Open the engine compartment door . b. Locate the two access holes on ...

  • Lincoln Electric VANTAGE SVM178-B - page 117

    INST ALLA TION A4.5 A4.5 V ANT AGE® 500 PRE-OPERA TION ENGINE SERVICE READ the engine operating and maintenance instruc- tions supplied with this machine. • Keep hands away from the engine muffler or HOT engine parts. • Stop engine and allow to cool before fueling. • Do not smoke when fueling. • Fill fuel tank at a moderate rate and do n ...

  • Lincoln Electric VANTAGE SVM178-B - page 118

    INST ALLA TION A4.6 A4.6 V ANT AGE® 500 IMPORT ANT : T o prevent ELECTRICAL DAMAGE WHEN: a) Installing new batteries b) Using a booster Use correct polarity — Negative Ground. The V antage is shipped with the negative battery cable disconnected. Before you operate the machine, make sure the Engine Switch is in the OFF position and attach the dis ...

  • Lincoln Electric VANTAGE SVM178-B - page 119

    INST ALLA TION A4.7 A4.7 V ANT AGE® 500 WELDING OUTPUT CABLES With the engine off, route the electrode and work cables through the strain relief bracket provided on the front of the base and connect to the terminals provided. These connections should be checked periodically and tightened if necessary . Listed in T able A4.1 are copper cable sizes ...

  • Lincoln Electric VANTAGE SVM178-B - page 120

    INST ALLA TION A4.8 A4.8 V ANT AGE® 500 Figure A4.1 Connection of the V antage to Premises Wiring 1. Install the double-pole, double-throw switch between the power company meter and the premises disconnect. Switch rating must be the same or greater than the cus- tomer ’s premises disconnect and service over current protection. 2. T ake necessary ...

  • Lincoln Electric VANTAGE SVM178-B - page 121

    T ABLE OF CONTENTS - OPERA TION SECTION B4.1 B4.1 V ANT AGE® 500 Operation - V ANT AGE® 500 Cummins B3.3 (Code 10996) Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B4.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 122

    OPERA TION B4.2 B4.2 V ANT AGE® 500 OPERA TING INSTRUCTIONS Read and understand this entire section before oper- ating your V antage 500. SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions: detailed eng ...

  • Lincoln Electric VANTAGE SVM178-B - page 123

    OPERA TION B4.3 B4.3 V ANT AGE® 500 RECOMMENDED APPLICA TIONS WELDER The V antage 500 provides excellent constant current DC welding output for stick (SMA W) and TIG welding. The V antage 500 also provides excellent constant volt- age DC welding output for MIG (GMAW) and Innershield (FCA W) welding. GENERA TOR The V antage 500 provides smooth 120/ ...

  • Lincoln Electric VANTAGE SVM178-B - page 124

    OPERA TION B4.4 B4.4 V ANT AGE® 500 ENGINE CONTROLS (Items 1 through 9) 1 . R UN ST O P SW IT CH T oggling the switch to the RUN position energizes the fuel solenoid for approximately 30 seconds. The engine must be started within that time or the fuel solenoid will denergize, and the switch must be tog- gled to reset the timer . 2. ST ART PUSHBUTT ...

  • Lincoln Electric VANTAGE SVM178-B - page 125

    OPERA TION B4.5 B4.5 V ANT AGE® 500 6. OIL PRESSURE GAUGE The gauge displays the engine oil pressure when the engine is running. 7. ENGINE PROTECTION  The yellow engine protection light remains off with proper oil pressure and under normal operating tem- peratures. If the light turns on, the engine protection system will stop the engine. Check ...

  • Lincoln Electric VANTAGE SVM178-B - page 126

    OPERA TION B4.6 B4.6 V ANT AGE® 500 WELDING CONTROLS (Items 10 through 19) 10. OUTPUT CONTROL: The OUTPUT dial is used to preset the output voltage or current as displayed on the digital meters for the four welding modes. When in the CC-STICK, DOWN- HILL PIPE or CV -WIRE modes and when a remote control is connected to the 6-Pin or 14-Pin Connector ...

  • Lincoln Electric VANTAGE SVM178-B - page 127

    OPERA TION B4.7 B4.7 V ANT AGE® 500 20. CIRCUIT BREAKERS These circuit breakers provide separate overload current protection for each 120V circuit at the 240V single phase receptacle, each 120V single phase receptacle, the 240V three phase receptacle, the 120V AC in the 14-Pin connector , the 42V AC in the 14-Pin connector and battery circuit over ...

  • Lincoln Electric VANTAGE SVM178-B - page 128

    OPERA TION B4.8 B4.8 V ANT AGE® 500 WELDER OPERA TION DUTY CYCLE Duty Cycle is the the ratio of the uninterrupted on-load duration to 10 minutes. The total time period of one complete on-load and no-load cycle is 10 minutes. For example, in the case of a 60% duty cycle, load is applied continuously for 6 minutes followed by a no- load period of 4 ...

  • Lincoln Electric VANTAGE SVM178-B - page 129

    OPERA TION B4.9 B4.9 V ANT AGE® 500 V ANT AGE 500 SETTINGS WHEN USING THE K799 HI-FREQ UNIT • Set the WELD MODE switch to the 20-250 setting (TIG). • Set the IDLER switch to the HIGH position. • Set the WELDING TERMINALS switch to the WELD TERMINALS ON position. This will close the solid state contactor and provide an always “hot” electr ...

  • Lincoln Electric VANTAGE SVM178-B - page 130

    OPERA TION B4.10 B4.10 V ANT AGE® 500 WIRE FEED (CONST ANT VOL T AGE) WELDING Connect a wire feeder to the V antage 500 and set welder controls according to the instructions listed ear- lier in this section. See the operator ’s manual for the wire feeder or the “Diagrams ” section of this manual for connecting instructions of various Lincoln ...

  • Lincoln Electric VANTAGE SVM178-B - page 131

    OPERA TION B4.11 B4.11 V ANT AGE® 500 T ABLE B3.4 – V ANT AGE 500 EXTENSION CORD LENGTH RECOMMENDA TIONS Current (Amps) 15 15 20 20 25 30 38 50 V oltage (V olts) 120 240 120 240 240 240 240 240 Load (W atts) 1800 3600 2400 48010 6000 7200 9000 12000 30 60 (9) (18) 40 75 30 60 (12) (23) (9) (18) 75 150 50 100 90 75 (23) (46) (15) (30) (27) (23) 1 ...

  • Lincoln Electric VANTAGE SVM178-B - page 132

    NOTES B4.12 B4.12 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 133

    T ABLE OF CONTENTS - ACCESSORIES SECTION C4.1 C4.1 V ANT AGE® 500 Accessories - V ANT AGE® 500 Cummins B3.3 (Code 10996) Options/Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C4.1 Optional Field Installed Accessories . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 134

    ACCESSORIES C4.2 C4.2 V ANT AGE® 500 K802N POWER PLUG KIT - Provides four 120V plugs rated at 20 amps each and one dual voltage, full KV A plug rated at 120/240V , 50 amps. 120V plug may not be compatible with NEMA common household receptacles. K802R POWER PLUG KIT - Provides four 120V plugs rated 15 amps each and one dual voltage, full KV A plu ...

  • Lincoln Electric VANTAGE SVM178-B - page 135

    ACCESSORIES C4.3 C4.3 V ANT AGE® 500 TIG OPTIONS K1783-9 PT A-26V TIG T orch Air Cooled 200 amp torch (2 piece) equipped with valve for gas flow control. 25 ft. (7.6m) length. KP509 Magnum Parts Kit for PT A-26V TIG T orch Magnum Parts Kit provides all the torch accessories you need to start welding. Parts kit provides collets, collet bodies, a ...

  • Lincoln Electric VANTAGE SVM178-B - page 136

    NOTES C4.4 C4.4 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 137

    T ABLE OF CONTENTS - MAINTENANCE SECTION D4.1 D4.1 V ANT AGE® 500 Maintenance - V ANT AGE® 500 Cummins B3.3 (Code 10996) Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D4.2 Routine and Periodic Maintenance . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 138

    MAINTENANCE D4.2 D4.2 V ANT AGE® 500 SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • T urn the engine off before working inside the machine. • Remove covers or guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is com- plete. • If cove ...

  • Lincoln Electric VANTAGE SVM178-B - page 139

    MAINTENANCE D4.3 D4.3 V ANT AGE® 500 3. Apply a thin coat of new oil to the rubber gasket on the new oil filter . 4. Spin the new filter onto the mounting adapter finger tight until the gasket is evenly seated. Then turn it down another 1/2 turn. Do not overtighten the new filter . 5. Refill the engine with the proper amount and type of oil as des ...

  • Lincoln Electric VANTAGE SVM178-B - page 140

    MAINTENANCE D4.4 D4.4 V ANT AGE® 500 FUEL FIL TERS When working on the fuel system • Keep naked lights away , do not smoke ! • Do not spill fuel ! The V ANT AGE 500 Cummins is equipped with a Fuel Filter/W ater Separator located after the lift pump and before fuel injectors.The procedure for changing the fil- ter is as follows. See Figure D4.2 ...

  • Lincoln Electric VANTAGE SVM178-B - page 141

    MAINTENANCE D4.5 D4.5 V ANT AGE® 500 AIR FIL TER Excessive air filter restriction will result in reduced engine life. The air filter element is a dry cartridge type. It can be cleaned and reused. However , damaged elements should not be reused. Stop engine after 100 hours of running time and clean filter element. Replace the filter if necessary . ...

  • Lincoln Electric VANTAGE SVM178-B - page 142

    MAINTENANCE D4.6 D4.6 V ANT AGE® 500 MAINTENANCE INSTRUCTIONS Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 143

    MAINTENANCE D4.7 D4.7 V ANT AGE® 500 WELDER/GENERA TOR MAINTENANCE STORAGE: Store the V antage 500 in clean, dry , pro- tected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air . Do this at least once a week in particularly dirty areas. NAMEPLA TES: Whenever routine maintenance is per- formed on this machine ...

  • Lincoln Electric VANTAGE SVM178-B - page 144

    MAINTENANCE D4.8 D4.8 V ANT AGE® 500 BA TTER Y MAINTENANCE GASES FROM BA TTER Y can explode. • Keep sparks, flame, and cigarettes away from battery . BA TTERY ACID can burn eyes and skin. • Wear gloves and eye protection and be careful when working near a battery . Follow the instructions printed on the battery . T o prevent EXPLOSION when: ? ...

  • Lincoln Electric VANTAGE SVM178-B - page 145

    MAINTENANCE D4.9 D4.9 V ANT AGE® 500 WARNING 1 2 4 3 5 7 6A 9 10 OFF FIGURE D.5 – MAJOR COMPONENT LOCA TIONS 1. CONTROL P ANEL ASSEMBL Y 2. CONTROL BOX & OUTPUT ASSEMBL Y 3. POWER MODULE ASSEMBL Y 4. BASE & LIFT BALE ASSEMBL Y 5. FUEL T ANK & MOUNTING 6A. ENGINE ASSEMBL Y 7. GENERA TOR FRAME 8. SOLENOID ASSEMBL Y 9. CASEBACK 10. CASE ...

  • Lincoln Electric VANTAGE SVM178-B - page 146

    NOTES D4.10 D4.10 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 147

    T ABLE OF CONTENTS - INST ALLA TION SECTION A5.1 A5.1 V ANT AGE® 500 Installation - V ANT AGE® 500 Cummins B3.3 (Code 1 1 181, 1 1416) T echnical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A5.2 Safety Precautions . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 148

    INST ALLA TION A5.2 A5.2 V ANT AGE® 500 TECHNICAL SPECIFICA TIONS - V ANT AGE 500 CUMMINS (K2406-1) INPUT - DIESEL ENGINE Make /Model Description Speed (RPM) Displacement Starting Capacities System CUMMINS 4 cylinder High Idle 1890 199 cu. in 12VDC battery Fuel B3.3 53HP (40 kw) Low Idle 1400 (3.3L) & Starter 25 US gal. Diesel Engine @ 1800 RP ...

  • Lincoln Electric VANTAGE SVM178-B - page 149

    INST ALLA TION A5.3 A5.3 V ANT AGE® 500 Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions, detailed engine starting, operating and m ...

  • Lincoln Electric VANTAGE SVM178-B - page 150

    INST ALLA TION A5.4 A5.4 V ANT AGE® 500 LIFTING The V antage lift bale should be used to lift the machine. The V antage is shipped with the lift bale retracted. Before attempting to lift the V antage, secure the lift bale in a raised position. Secure the lift bale as follows: a. Open the engine compartment door . b. Locate the two access holes on ...

  • Lincoln Electric VANTAGE SVM178-B - page 151

    INST ALLA TION A5.5 A5.5 V ANT AGE® 500 PRE-OPERA TION ENGINE SERVICE READ the engine operating and maintenance instruc- tions supplied with this machine. • Keep hands away from the engine muf- fler or HOT engine parts. • Stop engine and allow to cool before fueling. • Do not smoke when fueling. • Fill fuel tank at a moderate rate and do ...

  • Lincoln Electric VANTAGE SVM178-B - page 152

    INST ALLA TION A5.6 A5.6 V ANT AGE® 500 IMPORT ANT : T o prevent ELECTRICAL DAMAGE WHEN: a) Installing new batteries b) Using a booster Use correct polarity — Negative Ground. The V antage is shipped with the negative battery cable disconnected. Before you operate the machine, make sure the Engine Switch is in the OFF position and attach the dis ...

  • Lincoln Electric VANTAGE SVM178-B - page 153

    INST ALLA TION A5.7 A5.7 V ANT AGE® 500 WELDING OUTPUT CABLES With the engine off, route the electrode and work cables through the strain relief bracket provided on the front of the base and connect to the terminals provided. These connections should be checked periodically and tightened if necessary . Listed in T able A5.1 are copper cable sizes ...

  • Lincoln Electric VANTAGE SVM178-B - page 154

    INST ALLA TION A5.8 A5.8 V ANT AGE® 500 Figure A5.1 Connection of the V antage to Premises Wiring 1. Install the double-pole, double-throw switch between the power company meter and the premises disconnect. Switch rating must be the same or greater than the cus- tomer ’s premises disconnect and service over current protection. 2. T ake necessary ...

  • Lincoln Electric VANTAGE SVM178-B - page 155

    T ABLE OF CONTENTS - OPERA TION SECTION B5.1 B5.1 V ANT AGE® 500 Operation - V ANT AGE® 500 Cummins B3.3 (Codes 1 1 181 & 1 1416) Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B5.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 156

    OPERA TION B5.2 B5.2 V ANT AGE® 500 OPERA TING INSTRUCTIONS Read and understand this entire section before oper- ating your V antage 500. SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have thoroughly read all operating and maintenance man- uals supplied with your machine. They include impor- tant safety precautions: detailed e ...

  • Lincoln Electric VANTAGE SVM178-B - page 157

    OPERA TION B5.3 B5.3 V ANT AGE® 500 RECOMMENDED APPLICA TIONS WELDER The V antage 500 provides excellent constant current DC welding output for stick (SMA W) and TIG welding. The V antage 500 also provides excellent constant volt- age DC welding output for MIG (GMAW) and Innershield (FCA W) welding. GENERA TOR The V antage 500 provides smooth 120/ ...

  • Lincoln Electric VANTAGE SVM178-B - page 158

    OPERA TION B5.4 B5.4 V ANT AGE® 500 ENGINE CONTROLS (Items 1 through 9) 1 . R UN ST O P SW IT CH T oggling the switch to the RUN position energizes the fuel solenoid for approximately 30 seconds. The engine must be started within that time or the fuel solenoid will denergize, and the switch must be tog- gled to reset the timer . 2. ST ART PUSHBUTT ...

  • Lincoln Electric VANTAGE SVM178-B - page 159

    OPERA TION B5.5 B5.5 V ANT AGE® 500 6. OIL PRESSURE GAUGE The gauge displays the engine oil pressure when the engine is running. 7. ENGINE PROTECTION  The yellow engine protection light remains off with proper oil pressure and under normal operating tem- peratures. If the light turns on, the engine protection system will stop the engine. Check ...

  • Lincoln Electric VANTAGE SVM178-B - page 160

    OPERA TION B5.6 B5.6 V ANT AGE® 500 WELDING CONTROLS (Items 10 through 19) 10. OUTPUT CONTROL: The OUTPUT dial is used to preset the output voltage or current as displayed on the digital meters for the four welding modes. When in the CC-STICK, DOWN- HILL PIPE or CV -WIRE modes and when a remote control is connected to the 6-Pin or 14-Pin Connector ...

  • Lincoln Electric VANTAGE SVM178-B - page 161

    OPERA TION B5.7 B5.7 V ANT AGE® 500 20. CIRCUIT BREAKERS These circuit breakers provide separate overload current protection for each 120V circuit at the 240V single phase receptacle, each 120V single phase receptacle, the 240V three phase receptacle, the 120V AC in the 14-Pin connector , the 42V AC in the 14-Pin connector and battery circuit over ...

  • Lincoln Electric VANTAGE SVM178-B - page 162

    OPERA TION B5.8 B5.8 V ANT AGE® 500 WELDER OPERA TION DUTY CYCLE Duty Cycle is the the ratio of the uninterrupted on-load duration to 10 minutes. The total time period of one complete on-load and no-load cycle is 10 minutes. For example, in the case of a 60% duty cycle, load is applied continuously for 6 minutes followed by a no- load period of 4 ...

  • Lincoln Electric VANTAGE SVM178-B - page 163

    OPERA TION B5.9 B5.9 V ANT AGE® 500 V ANT AGE 500 SETTINGS WHEN USING THE K799 HI-FREQ UNIT • Set the WELD MODE switch to the 20-250 setting (TIG). • Set the IDLER switch to the HIGH position. • Set the WELDING TERMINALS switch to the WELD TERMINALS ON position. This will close the solid state contactor and provide an always “hot” electr ...

  • Lincoln Electric VANTAGE SVM178-B - page 164

    OPERA TION B5.10 B5.10 V ANT AGE® 500 WIRE FEED (CONST ANT VOL T AGE) WELDING Connect a wire feeder to the V antage 500 and set welder controls according to the instructions listed ear- lier in this section. See the operator ’s manual for the wire feeder or the “Diagrams ” section of this manual for connecting instructions of various Lincoln ...

  • Lincoln Electric VANTAGE SVM178-B - page 165

    OPERA TION B5.11 B5.11 V ANT AGE® 500 SIMUL T ANEOUS WELDING AND AUXILIAR Y POWER LOADS It must be noted that the auxiliary power ratings are with no welding load. Simultaneous welding and power loads are specified in table B5.4. The permissible currents shown assume that current is being drawn from either the 120 V AC or 240 V AC supply (not both ...

  • Lincoln Electric VANTAGE SVM178-B - page 166

    NOTES B5.12 B5.12 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 167

    T ABLE OF CONTENTS - ACCESSORIES SECTION C5.1 C5.1 V ANT AGE® 500 Accessories - V ANT AGE® 500 Cummins B3.3 (Codes 1 1 181 &1 1416) Options/Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C5.1 Optional Field Installed Accessories . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 168

    ACCESSORIES C5.2 C5.2 V ANT AGE® 500 K802N POWER PLUG KIT - Provides four 120V plugs rated at 20 amps each and one dual voltage, full KV A plug rated at 120/240V , 50 amps. 120V plug may not be compatible with NEMA common household receptacles. K802R POWER PLUG KIT - Provides four 120V plugs rated 15 amps each and one dual voltage, full KV A plu ...

  • Lincoln Electric VANTAGE SVM178-B - page 169

    ACCESSORIES C5.3 C5.3 V ANT AGE® 500 TIG OPTIONS K1783-9 PT A-26V TIG T orch Air Cooled 200 amp torch (2 piece) equipped with valve for gas flow control. 25 ft. (7.6m) length. KP509 Magnum Parts Kit for PT A-26V TIG T orch Magnum Parts Kit provides all the torch accessories you need to start welding. Parts kit provides collets, collet bodies, a ...

  • Lincoln Electric VANTAGE SVM178-B - page 170

    NOTES C5.4 C5.4 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 171

    T ABLE OF CONTENTS - MAINTENANCE SECTION D5.1 D5.1 V ANT AGE® 500 MAINTENANCE - V ANT AGE 500 CUMMINS (CODE 1 1 181 & 1 1416) Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D5.2 Routine Maintenance . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 172

    MAINTENANCE D5.2 D5.2 V ANT AGE® 500 SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • T urn the engine off before working inside the machine. • Remove covers or guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is complete. • If covers ...

  • Lincoln Electric VANTAGE SVM178-B - page 173

    MAINTENANCE D5.3 D5.3 V ANT AGE® 500 3. Apply a thin coat of new oil to the rubber gasket on the new oil filter . 4. Spin the new filter onto the mounting adapter finger tight until the gasket is evenly seated. Then turn it down another 1/2 turn. Do not overtighten the new filter . 5. Refill the engine with the proper amount and type of oil as des ...

  • Lincoln Electric VANTAGE SVM178-B - page 174

    MAINTENANCE D5.4 D5.4 V ANT AGE® 500 FUEL FIL TERS When working on the fuel system • Keep naked lights away , do not smoke ! • Do not spill fuel ! ------------------------------------------------------------------------ The V ANT AGE 500 Cummins is equipped with a Fuel Filter/W ater Separator located after the lift pump and before fuel injecto ...

  • Lincoln Electric VANTAGE SVM178-B - page 175

    MAINTENANCE D5.5 D5.5 V ANT AGE® 500 AIR FIL TER: Excessive air filter restriction will result in reduced engine life. The air filter element is a dry cartridge type. It can be cleaned and reused. However , damaged elements should not be reused. Stop engine after 100 hours of running time and clean filter element. Replace the filter if necessary . ...

  • Lincoln Electric VANTAGE SVM178-B - page 176

    MAINTENANCE D5.6 D5.6 V ANT AGE® 500 MAINTENANCE INSTRUCTIONS Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 177

    MAINTENANCE D5.7 D5.7 V ANT AGE® 500 WELDER/GENERA TOR MAINTENANCE STORAGE: Store the V antage 500 in clean, dry , pro- tected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air . Do this at least once a week in particularly dirty areas. NAMEPLA TES: Whenever routine maintenance is per- formed on this machine ...

  • Lincoln Electric VANTAGE SVM178-B - page 178

    MAINTENANCE D5.8 D5.8 V ANT AGE® 500 BA TTER Y MAINTENANCE GASES FROM BA TTER Y can explode. • Keep sparks, flame, and cigarettes away from battery . BA TTERY ACID can burn eyes and skin. • Wear gloves and eye protection and be careful when working near a battery . Follow the instructions printed on the battery . T o prevent EXPLOSION when: ? ...

  • Lincoln Electric VANTAGE SVM178-B - page 179

    MAINTENANCE D5.9 D5.9 V ANT AGE® 500 WARNING 1 2 4 3 5 7 6A 9 10 OFF FIGURE D5.4 – MAJOR COMPONENT LOCA TIONS 1. CONTROL P ANEL ASSEMBL Y 2. CONTROL BOX & OUTPUT ASSEMBL Y 3. POWER MODULE ASSEMBL Y 4. BASE & LIFT BALE ASSEMBL Y 5. FUEL T ANK & MOUNTING 6A. ENGINE ASSEMBL Y 7. GENERA TOR FRAME 8. SOLENOID ASSEMBL Y 9. CASEBACK 10. CAS ...

  • Lincoln Electric VANTAGE SVM178-B - page 180

    NOTES D5.10 D5.10 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 181

    T ABLE OF CONTENTS-THEOR Y OF OPERA TION SECTION E-1 E-1 V ANT AGE® 500 Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 182

    THEOR Y OF OPERA TION E-2 E-2 V ANT AGE® 500 FIGURE E.2 - BA TTER Y , ENGINE, ROTOR, PULL COIL BOARD AND PERIPHERAL BOARD (ENGINE PROTECTION NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion GENERAL DESCRIPTION The V antage 500 is a diesel engine-driven welding power source capable of producing 500 amps at 40VDC at a 100% d ...

  • Lincoln Electric VANTAGE SVM178-B - page 183

    THEOR Y OF OPERA TION E-3 E-3 V ANT AGE® 500 FIGURE E.3 - WELD WINDINGS, RECTIFIER, POWER MODULES AND FEEDBACK WELD WINDINGS, RECTIFIER, POWER MODULES AND FEEDBACK The three-phase stator weld windings are connected to a three-phase rectifier bridge. The resultant DC voltage is applied to four paralleled capacitors incorporated within each of the t ...

  • Lincoln Electric VANTAGE SVM178-B - page 184

    THEOR Y OF OPERA TION E-4 E-4 V ANT AGE® 500 FIGURE E.4 - POWER MODULES AND WELD CONTROL BOARD WELD CONTROL BOARD The 80 VDC derived from the filter capacitors on the Power Modules, supplies various regulated DC volt- ages to operate the Weld Control PC board circuitry . It also supplies two regulated DC voltages to operate the IGBT driver circuit ...

  • Lincoln Electric VANTAGE SVM178-B - page 185

    THEOR Y OF OPERA TION E-5 E-5 V ANT AGE® 500 INSULA TED GA TE BIPOLAR TRANSIST OR (IGBT) OPERA TION An IGBT is a type of transistor . IGBT s are semicon- ductors well suited for high frequency switching and high current applications. Drawing A in Figure E.5 shows an IGBT in a passive mode. There is no gate signal, zero volts relative to the source ...

  • Lincoln Electric VANTAGE SVM178-B - page 186

    THEOR Y OF OPERA TION E-6 E-6 V ANT AGE® 500 PULSE WIDTH MODULA TION The term PULSE WIDTH MODULA TION is used to describe how much time is devoted to conduction in the cycle. Changing the pulse width is known as MODULA- TION. Pulse Width Modulation (PWM) is the varying of the pulse width over the allowed range of a cycle to affect the output of th ...

  • Lincoln Electric VANTAGE SVM178-B - page 187

    THEOR Y OF OPERA TION E-7 E-7 V ANT AGE® 500 CHOPPER TECHNOLOGY FUNDAMENT ALS The new era of welding machines such as the V antage 500, employ a technology whereby a DC source is turned on and off (chopped up) at high speed, then smoothed through an inductor to control an arc. Hence the name “Chopper .” The biggest advantage of chopper technol ...

  • Lincoln Electric VANTAGE SVM178-B - page 188

    NOTES E-8 E-8 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 189

    T ABLE OF CONTENTS - TROUBLESHOOTING AND REP AIR F-1 F-1 V ANT AGE® 500 T roubleshooting and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-1 How to Use T roubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 190

    TROUBLESHOOTING AND REP AIR F-2 F-2 V ANT AGE® 500 This T roubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below . Step 1. LOCA TE PROBLEM (SYMPTOM). Look under the column labeled “PROBLEM (SYMPTOMS)”. This column describes pos- sible symptoms that the ...

  • Lincoln Electric VANTAGE SVM178-B - page 191

    TROUBLESHOOTING AND REP AIR F-3 F-3 V ANT AGE® 500 Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrical connections. T o avoid prob- lems when troubleshooting and replacing PC boards, please use the following procedure: 1. Determine to the best of your technical ability that th ...

  • Lincoln Electric VANTAGE SVM178-B - page 192

    OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric VANTAGE SVM178-B - page 193

    OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric VANTAGE SVM178-B - page 194

    OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric VANTAGE SVM178-B - page 195

    FUNCTION PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubl ...

  • Lincoln Electric VANTAGE SVM178-B - page 196

    FUNCTION PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubl ...

  • Lincoln Electric VANTAGE SVM178-B - page 197

    ENGINE PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric VANTAGE SVM178-B - page 198

    ENGINE PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric VANTAGE SVM178-B - page 199

    ENGINE PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric VANTAGE SVM178-B - page 200

    WELDING PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical trouble ...

  • Lincoln Electric VANTAGE SVM178-B - page 201

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 202

    FIGURE F .1 – DOOR REMOV AL CASE COVER REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. T urn the engine off. 2. Using the 3/8" wrench, remove the battery cover . Slide the battery out and disconnect the negative battery cable. 3. Unlatch and open the engine service access door . 4. Support the door assembly . Using the 3/8" ...

  • Lincoln Electric VANTAGE SVM178-B - page 203

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 204

    B1 B2 B3 B4 B5 B6 B7 B8 POWER RESIST OR INSULA TED GLOVE FIGURE F .2 – CHOPPER MODULE CAP ACITOR TERMINAL DISCHARGE CHOPPER MODULE CAP ACIT OR DISCHARGE PROCEDURE (CONTINUED) PROCEDURE 1. Turn engine off. 2. Perform the Case Cover Removal Procedure. Note: It is necessary to remove the fuel cap in order to take the case cover off the machine. Be s ...

  • Lincoln Electric VANTAGE SVM178-B - page 205

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 206

    B1 B4 B5 B6 B2 B3 87 W8 LEAD W7 LEAD POS LEAD POS LEAD NEG LEAD NEG LEAD 88 PWM Input Present Power at Recitifier Bridge Chopper Operating LED3 LED2 LED1 LXX XX X- X FIGURE F .3 – LEADS & TERMINALS CHOPPER MODULE RESIST ANCE TEST (CONTINUED) PROCEDURE 1. T urn the engine off. 2. Perform the Case Cover Removal procedure. 3. Perform the Capacit ...

  • Lincoln Electric VANTAGE SVM178-B - page 207

    T ABLE F .1 – CHOPPER TEST T ABLE CHOPPER MODULE RESIST ANCE TEST (CONTINUED) TROUBLESHOOTING AND REP AIR F-19 F-19 V ANT AGE® 500 B5 B6 6k to 9k B6 B5 6k to 9k B4 B5 200k or higher B5 B4 400k or higher B4 B6 200k or higher B6 B4 400k or higher B2 B3 6k to 9k B3 B2 6k to 9k B4 B2 200k or higher B2 B4 400k or higher B4 B3 200k or higher B3 B4 400 ...

  • Lincoln Electric VANTAGE SVM178-B - page 208

    NOTES F-20 F-20 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 209

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 210

    Shutdown Solenoid Idler Solenoid FIGURE F .4 – IDLER SOLENOID LEAD TERMINALS IDLER SOLENOID TEST PROCEDURE (CONTINUED) TEST PROCEDURE 1. T urn the engine off. 2. Unlatch, lift, and secure the right side engine ser- vice access door . 3. Locate and separate J55/P55 connector that attaches the idler solenoid leads to the wiring har- ness leads (#22 ...

  • Lincoln Electric VANTAGE SVM178-B - page 211

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 212

    Shutdown Solenoid Idler Solenoid FIGURE F .5 – SHUTDOWN SOLENOID SHUTDOWN SOLENOID TEST PROCEDURE TEST PROCEDURE 1. T urn the engine off. 2. Unlatch, lift, and secure the right side engine ser- vice access door . 3. Locate and separate J54 / P54 connector that attaches the shutdown solenoid leads to the wiring harness leads ( #262, #232 and #265) ...

  • Lincoln Electric VANTAGE SVM178-B - page 213

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 214

    OFF MARK BLOWER PADDLE HERE FIGURE F .6 – STROBE MARK LOCA TION ENGINE THROTTLE ADJUSTMENT TEST PROCEDURE (CONTINUED) PROCEDURE Strobe-tach Method 1. Conduct this procedure with the engine OFF . 2. Unlatch, lift and secure the right side engine ser- vice access door . Perform the Case Cover Removal and Replacement Procedure . (For Strobe-T ach me ...

  • Lincoln Electric VANTAGE SVM178-B - page 215

    Shutdown Solenoid LEFT SIDE Idler Solenoid Adjusting Collar Locking Nut Adjusting Screw Locking Nut FIGURE F .7 – HIGH AND LOW IDLE ADJUSTMENTS - CUMMINS ENGINE ONL Y ENGINE THROTTLE ADJUSTMENT TEST PROCEDURE (CONTINUED) PROCEDURE Frequency Counter Method 1. Plug the frequency counter into one of the 1 15 V AC auxiliary receptacles. 2. Start the ...

  • Lincoln Electric VANTAGE SVM178-B - page 216

    ENGINE THROTTLE ADJUSTMENT TEST PROCEDURE (CONTINUED) PROCEDURE Oscilloscope Method 1. Connect the oscilloscope to the 1 15 V AC recepta- cle, according to the manufacturer ’s instructions. At HIGH IDLE (1900 RPM), the waveform should exhibit a period of 15.8 milliseconds. At LOW IDLE (1475 RPM), the waveform should exhibit a period of 20.3 milli ...

  • Lincoln Electric VANTAGE SVM178-B - page 217

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 218

    SLIP RINGS BRUSH HOLDER ASSEMBL Y ACCESS P ANEL FIGURE F .8 – ROTOR BRUSH LEADS ROT OR RESIST ANCE TEST (CONTINUED) PROCEDURE 1. Conduct this test with the engine off. 2. Using the 3/8" wrench, remove the right front case side. 3. Using the 3/8" wrench, remove the brush holder access panel. See Figure F .10. 4. Using the 3/8" wrenc ...

  • Lincoln Electric VANTAGE SVM178-B - page 219

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 220

    #200A #200B #201 FIGURE F .9 – ROTOR BRUSH LOCA TION FLASHING AND ROT OR VOL T AGE TEST (CONTINUED) PROCEDURE 1. Using the 3/8" wrench, remove the sheet metal screws from the right front case side. 2. Carefully remove the right case side. 3. Set the volt/ohmmeter to the DC volts position. 4. Locate leads #200A and #201A at the rotor brush- e ...

  • Lincoln Electric VANTAGE SVM178-B - page 221

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 222

    FIGURE F .10 – FRONT CONTROL P ANEL REMOV AL ST A T OR VOL T AGE TEST (CONTINUED) PROCEDURE 1. T urn the engine off. 2. Using the 3/8" wrench, remove the screws holding the front control panel to the case top and sides. 3. Carefully lower the front control panel. 4. Using the 3/8" wrench, remove the front left and right side panels. 5. ...

  • Lincoln Electric VANTAGE SVM178-B - page 223

    32 32A 42A 42B 236A CB6 CB5 CB3 CB2 J13 CB1 3C 6D 3D 6 4 3 5C 5E 6B 6C 3B 4A GND-L STATOR LEADS 3A GND-C GND-D 6E 5B J12 J10 GND-E J11 238B Back of Control Panel T ypical 3Ø Auxiliary Machine FIGURE F .1 1 – AUXILIAR Y LEAD TEST LOCA TIONS ON BACK OF CONTROL P ANEL ST A T OR VOL T AGE TEST (CONTINUED) TROUBLESHOOTING AND REP AIR F-35 F-35 ...

  • Lincoln Electric VANTAGE SVM178-B - page 224

    WELD WINDING LEAD CONNECTIONS W1 W6 W3 W2 W5 W4 FIGURE F .12 – OUTPUT RECTIFIER DIODE BRIDGE ST A T OR VOL T AGE TEST (CONTINUED) 1. Locate the weld winding leads connected to the three-phase output rectifier diode bridge. See Figure F .12. 2. Check for approximately 68V AC from: W1/W6 to W2/W3. W1/W6 to W4/W5 W2/W3 to W4/W5 3. If any of these vo ...

  • Lincoln Electric VANTAGE SVM178-B - page 225

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 226

    FIGURE F .13 – DOOR REMOV AL OUTPUT RECTIFIER BRIDGE TEST (CONTINUED) PROCEDURE 1. T urn the engine off. 2. Perform Case Cover Removal Procedure . 3. Perform Chopper Module Capacitor Discharge Procedure . 4. Using the 3/8" wrench, remove the three screws holding the lower front panel (output panel) to the case front assembly . Then remove th ...

  • Lincoln Electric VANTAGE SVM178-B - page 227

    WELD WINDING LEAD CONNECTIONS W1 W6 W3 W2 W5 W4 FIGURE F .14 – DIODE LEAD REMOV AL OUTPUT RECTIFIER BRIDGE TEST (CONTINUED) 9. Using the 7/16” wrench, remove the stator leads from the three AC terminals. Label leads for reassembly . Note leads and AC terminals place- ment for reassembly . See Figure F .15 . 10. Electronically isolate the 3 AC t ...

  • Lincoln Electric VANTAGE SVM178-B - page 228

    OUTPUT RECTIFIER BRIDGE TEST (CONTINUED) TROUBLESHOOTING AND REP AIR F-40 F-40 V ANT AGE® 500 FIGURE F .15 – DIODE LEAD REMOV AL AC 1 + - D.C. D.C. 1 2 3 AC DC+ DC- + - AC 1,2,3 1 2 3 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Ma ...

  • Lincoln Electric VANTAGE SVM178-B - page 229

    OUTPUT RECTIFIER BRIDGE TEST (CONTINUED) TROUBLESHOOTING AND REP AIR F-41 F-41 V ANT AGE® 500 T ABLE F .2 – DIODE TEST T ABLE AC1 DC(+) Forward Bias (Low Resistance) AC2 DC(+) Forward Bias (Low Resistance) AC3 DC(+) Forward Bias (Low Resistance) DC(-) AC1 Forward Bias (Low Resistance) DC(-) AC2 Forward Bias (Low Resistance) DC(-) AC3 Forward Bia ...

  • Lincoln Electric VANTAGE SVM178-B - page 230

    NOTES F-42 F-42 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 231

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 232

    ELECTRONIC GOVERNOR TEST (CONTINUED) TEST PROCEDURE CHECK CONTROLLER 1. T urn the Run/Stop switch to Run. Do not start engine. 2. The engine protection light should be ON for 5 sec- onds then go out. 3. After 30 additional seconds the light should come back on. 4. If a-c or 1-3 are OK then the controller is probably good. 5. If the engine protectio ...

  • Lincoln Electric VANTAGE SVM178-B - page 233

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 234

    #239 #281 #238 FIGURE F .16 – ENGINE AL TERNA TOR LOCA TION (DEUTZ 10995) CHARGING CIRCUIT TEST (CONTINUED) PROCEDURE 1. T urn engine off. 2. Using the 3/8" wrench, remove the left rear case cover . (remove right rear case cover for Cummins engine 10996) 3. Locate the engine alternator . See Figure F .16. 4. Start the engine and run it at hi ...

  • Lincoln Electric VANTAGE SVM178-B - page 235

    This is the typical auxiliary output volt- age generated from a properly operat- ing machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time. Note: Scope probes connected at machine 1 15V AC receptacle. SCOPE SETTINGS V olts/Div .....................50V/Div . Horizontal Sweep ...

  • Lincoln Electric VANTAGE SVM178-B - page 236

    0 volts 50V 5ms This is the typical DC open circuit out- put voltage generated from a properly operating machine in the Constant Current (CC)mode. Note that each vertical division repre- sents 50 volts and that each horizon- tal division represents 5 milliseconds in time. SCOPE SETTINGS V olts/Div .....................50V/Div . Horizontal Sweep ... ...

  • Lincoln Electric VANTAGE SVM178-B - page 237

    0 volts 20V 0.1ms This is the typical DC output voltage generated from a properly operating machine in the Constant Current (CC) mode. Note that each vertical division repre- sents 20 volts and that each horizon- tal division represents 0.1 millisec- onds in time. The machine was loaded with a resistance grid bank to 500 amps at 40 volts. SCOPE SET ...

  • Lincoln Electric VANTAGE SVM178-B - page 238

    0 volts 10V 5 µs This is the typical output voltage gen- erated from a properly operating machine in the TIG Mode. Note that each vertical division repre- sents 10 volts and that each horizontal division represents 50 microseconds in time. The machine was loaded with a resis- tance grid bank to 200 amps at 16 VDC. SCOPE SETTINGS V olts/Div ....... ...

  • Lincoln Electric VANTAGE SVM178-B - page 239

    0 volts 50V 5MS This is the typical auxiliary output volt- age generated from a properly operat- ing machine in the CV mode. Note that each vertical division repre- sents 50 volts and that each horizontal division represents 5 milliseconds in time. SCOPE SETTINGS V olts/Div .....................50V/Div . Horizontal Sweep .....5 ms/Div . Coupling .. ...

  • Lincoln Electric VANTAGE SVM178-B - page 240

    0 volts 20V 0.1ms This is the typical DC output voltage generated from a properly operating machine in the Constant V oltage (CV) mode. Note that each vertical division repre- sents 20 volts and that each horizon- tal division represents 5 milliseconds in time. The machine was loaded with a resistance grid bank to 500 amps at 40 volts. SCOPE SETTIN ...

  • Lincoln Electric VANTAGE SVM178-B - page 241

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 242

    Leads 262, 232M, 265 FIGURE F .17 – SHUTDOWN SOLENOID LEAD CONNECTIONS SHUTDOWN SOLENOID REMOV AL AND REPLACEMENT (DEUTZ) PROCEDURE 1. T urn engine off. 2. Unlatch, lift and secure the engine access door . 3. Locate and remove the spade connectors that attach the shutdown solenoid terminals to the wiring harness leads. Cut the cable tie. 4. Remov ...

  • Lincoln Electric VANTAGE SVM178-B - page 243

    Shutdwn Solenoid Idler Solenoid LEADS 262 232M 265 FIGURE F .18 – SHUTDOWN SOLENOID LINKAGE ARM ASSEMBL Y SHUTDOWN SOLENOID REMOV AL AND REPLACEMENT (CUMMINS) PROCEDURE 1. T urn engine off. 2. Unlatch. lift and secure engine access door . 3. Locate and remove the spade connectors that attach the shutdown solenoid terminals to the wiring harness l ...

  • Lincoln Electric VANTAGE SVM178-B - page 244

    NOTES F-56 F-56 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 245

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 246

    OUTPUT RECTIFIER BRIDGE 2 7/16" BOL TS 2 7/16" BOL TS 2 1/2" NUTS CHOPPER MODULES (2) HEA TSINKS FIGURE F .19 – DOOR REMOV AL OUTPUT RECTIFIER REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. T urn the engine off. 2. Perform the output panel removal as described in the Case Cover Removal procedure. 3. Perform the Chopp ...

  • Lincoln Electric VANTAGE SVM178-B - page 247

    Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed thr ...

  • Lincoln Electric VANTAGE SVM178-B - page 248

    PLUG FUEL LINES U-BOL TS (2 ) LEADS #229 AND #242D { FIGURE F .20 – FUEL T ANK REMOV AL DET AILS ST A T OR/ROTOR REMOV AL AND REPLACEMENT (CONTINUED) PROCEDURE Refer to Figure F .20. 1. T urn the engine off and disconnect battery leads and drain fuel. 2. Perform the Case Cover Removal procedure, including removing the output panel. 3. Perform the ...

  • Lincoln Electric VANTAGE SVM178-B - page 249

    #201A 6 #200D #4 FIL TER CAP ACITOR FIELD DIODE RECTIFIER BRIDGE FIGURE F .21 – PLUG J52/FIL TER CAP ACITOR/FIELD RECTIFIER BRIDGE DISCONNECTION ST A T OR/ROTOR REMOV AL AND REPLACEMENT (CONTINUED) 1 1. See Figure F .21. Using the slot head screw driver , disconnect leads #200A, #200B(+) and #201A(-) or remove screw cap bracket and remove cap fro ...

  • Lincoln Electric VANTAGE SVM178-B - page 250

    CONTROL BOX PULL COIL PC BOARD (LEADS #265 & #227 12 VDC STUD LEADS #232L & #232M FIGURE F .22 – BRUSH HOLDER AND LEAD REMOV AL ST A T OR/ROTOR REMOV AL AND REPLACEMENT (CONTINUED) PROCEDURE 1. T urn the engine off. 2. Using the 3/8" wrench, remove the battery cover . Slide the battery out and disconnect the negative battery cable. 3 ...

  • Lincoln Electric VANTAGE SVM178-B - page 251

    6 SCREWS SHROUD ACOUSTICAL FOAM FIGURE F .24 – DOOR REMOV AL ST A T OR/ROTOR REMOV AL AND REPLACEMENT (CONTINUED) 18. See Figure F .24. With the 5/16" wrench, remove the six screws that hold the top and bottom of the alternator shroud together . 19. With the 7/16" wrench, remove the two nuts, lock washers and flat washers that hold the ...

  • Lincoln Electric VANTAGE SVM178-B - page 252

    CENTER P ANEL LIFT FRAME WELDMENT BASE FUEL T ANK SUPPORTS F AN BAFFLE FIGURE F .25 – LIFT FRAME AND ASSOCIA TED COMPONENT REMOV AL ST A T OR/ROTOR REMOV AL AND REPLACEMENT (CONTINUED) In steps 20 – 24, the lift frame weldment, fuel tank sup- ports, and fan baffle are removed as a unit. See Figure F .25. 20. Using the 3/8" wrench, remove t ...

  • Lincoln Electric VANTAGE SVM178-B - page 253

    BOL TS (4) F AN HUB MOUNTING FOOT FL YWHEEL SPLASH PLA TE F AN NU T ST A TOR / ENGINE MOUNTING BOL TS & LOCK W ASHERS BEARING FIGURE F .26 – ST A TOR REMOV AL ST A T OR/ROTOR REMOV AL AND REPLACEMENT (CONTINUED) PROCEDURE First, cut any necessary cable ties in order to free the stator leads from the bundle of leads running to the control box. ...

  • Lincoln Electric VANTAGE SVM178-B - page 254

    FLEX PLA TE BLOWER SEGMENT (4) ROT OR FIGURE F .27 – ROTOR REMOV AL ST A T OR/ROTOR REMOV AL AND REPLACEMENT (CONTINUED) PROCEDURE Refer to Figure F .27 for rotor removal. 1. Support the rotor with the hoist. 2. Using the 5/8" wrench, remove the flex plate bolts, lock washers, and four blower segments. The rotor will be free to fall when the ...

  • Lincoln Electric VANTAGE SVM178-B - page 255

    ST A T OR/ROTOR REMOV AL AND REPLACEMENT (CONTINUED) LEAD RECONNECTION CHECKLIST ENGINE n Leads #5I and #229 to fuel level sensor n Brush leads #201(-) and #200B(+) n Leads #5H, and #201A, #200, #200A, and #6A to the field bridge rectifier OUTPUT P ANEL AND CONTROL BOX n Leads #232N and #227 to Pull Coil PC board n Leads #232L and #232N to 12 VDC i ...

  • Lincoln Electric VANTAGE SVM178-B - page 256

    TROUBLESHOOTING AND REP AIR F-68 F-68 V ANT AGE® 500 RETEST AFTER REP AIR Retest a machine: • If it is rejected under test for any reason that requires you to remove any mechanical part which could af fect the machine’s electrical characteristics. OR • If you repair or replace any electrical components. ENGINE RPM Mode No Load RPM Load RPM L ...

  • Lincoln Electric VANTAGE SVM178-B - page 257

    TROUBLESHOOTING AND REP AIR F-69 F-69 V ANT AGE® 500 RETEST AFTER REP AIR (CONTINUED) TOUCH ST ART TIG MODE OUTPUT Mode Selector Open Circuit Short Circuit Switch Fine Control V oltage Current TIG 20 - 250 A Maximum 10 - 15 18 - 28 TIG 20 - 250 A Minimum 10 - 15 18 - 28 AUXILIAR Y POWER OUTPUT 230 V olt Receptacle 1 15 V olt Receptacles Open Circu ...

  • Lincoln Electric VANTAGE SVM178-B - page 258

    NOTES F-70 F-70 V ANT AGE® 500 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 259

    T ABLE OF CONTENTS - DIAGRAM SECTION G-1 G-1 V ANT AGE® 500 Electrical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-1 Wiring Diagram (G4342 Code 10995 Deutz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric VANTAGE SVM178-B - page 260

    ELEcTricaL DiaGramS G-2 v aNTaGE® 500 WiriNG DiaGram - v aNT aGE®500 - G4342 (cODE 11095 DEuTz) O UTP UT CO NT R OL C CW RE CTI FIE R B RI D GE HOU R M ETER ALT 75 PIN C H P OT 278 SILVER - 232 R 238A 231 42A 41A 405A + 232 C FU EL OIL PR ESS URE 241 228 START B UTT ON 5L 229 232B 5M 247 OIL TE M PE R ATU RE 243 222 MOD E SELECTO R SW ITC H 206A ...

  • Lincoln Electric VANTAGE SVM178-B - page 261

    ELEcTricaL DiaGramS G-3 v aNTaGE® 500 WiriNG DiaGram - v aNT aGE® 500 - G4329 (cODE 10996) C B6 10A 42A 42 RE CTI FIE R B RI D GE 238A 231 42A 41A 243 232 41 START B UTT ON 238 222 MOD E SELECTO R SW ITC H 206A + 206A W2 W2 W3 W3 W5 W4 W5 W4 W1 W1 W6 W6 214 S5 218 1 2 3 220 A 4 - 206S 208B 208A 208B + 50MV= 400AMPS W4 & W5 W2 & W3 W1 & ...

  • Lincoln Electric VANTAGE SVM178-B - page 262

    ELEcTricaL DiaGramS G-4 v aNTaGE® 500 WiriNG DiaGram - v aNT aGE® 500 - G4847 (cODES 1 1180,1 1415 & 1 1468) C B6 10A 42A 42 RE CTI FIE R B RI D GE 42A 41A 41 222 MOD E SELECTO R SW ITC H 206A + 206A 214 S5 218 1 2 3 220 A 4 - 206S 208B 208A 208B + 50MV= 400AMPS W4 & W5 W2 & W3 W1 & W6 204S 23 2D STATO R 42V W INDI NG G484 7 B 208 ...

  • Lincoln Electric VANTAGE SVM178-B - page 263

    ELEcTricaL DiaGramS G-5 v aNTaGE® 500 WiriNG DiaGram - v aNT aGE® 500 - G4971 (cODES 1 1181 &1 1416) C B6 10A 42A 42 RE CTI FIE R B RI D GE 42A 41A 243 232 41 START B UTT ON 238 222 M OD E SELECTO R SW ITC H 206A + 206A 214 S5 218 1 2 3 220 A 4 - 206S 208B 208A 208B + 50MV= 400AMPS W4 & W5 W2 & W3 W1 & W6 204S STATO R 42V W INDI N ...

  • Lincoln Electric VANTAGE SVM178-B - page 264

    ELEcTricaL DiaGramS G-6 v aNTaGE® 500 SchEma Tic - cOmpLETE machiNE - G4363 (cODE 10995 DEuTz) p aGE 1 G 4363 E NGI N EE RI NG CO NT RO LLE D MA NU FA CT U RE R: No R EL EASE D F R OM X A.01 G4363 VANTAGE 50 0 ( DEUT Z) MACHI N E SCHEMA TI C NONE Reference bmuter D RAWN BY: DESIG N I NFO RMATI ON ENG I NEER: AP PRO VED : REFERENCE: EQ UIP M ENT TY ...

  • Lincoln Electric VANTAGE SVM178-B - page 265

    ELEcTricaL DiaGramS G-7 v aNTaGE® 500 SchEma Tic - cOmpLETE machiNE - G4363 (cODE 10995 DEuTz) p aGE 2 E N- 1 7 0 G 4363 E NGI N EE RI NG CO NT RO LLE D MA NU FA CT U RE R: No R EL EASE D F R OM X A.01 G4363 VANTAGE 50 0 ( DEUT Z) MACHI N E SCHEMA TI C NONE Reference bmuter D RAWN BY: DESIG N I NFO RMATI ON ENG I NEER: AP PRO VED : REFERENCE: EQ U ...

  • Lincoln Electric VANTAGE SVM178-B - page 266

    ELEcTricaL DiaGramS G-8 v aNTaGE® 500 SchEma Tic - cOmpLETE machiNE - G4442 (cODE 10996 cummiNS) p aGE1 G 4442 E NGI N EE RI NG CO NT RO LLE D MA NU FA CT U RE R: No R EL EASE D F R OM X A.01 G4442 VANTAGE 500 ( CUMMINS) MACHI N E SCHEMA TI C NONE Reference bmuter D RAWN BY: DESIG N I NFO RMATI ON ENG I NEER: AP PRO VED : REFERENCE: EQ UIP M ENT T ...

  • Lincoln Electric VANTAGE SVM178-B - page 267

    ELEcTricaL DiaGramS G-9 v aNTaGE® 500 SchEma Tic - cOmpLETE machiNE - G4442 (cODE 10996 cummiNS) p aGE 2 G 4442 E NGI N EE RI NG CO NT RO LLE D MA NU FA CT U RE R: No R EL EASE D F R OM X A.01 G4442 VANTAGE 500 ( CUMMINS) MACHI N E SCHEMA TI C NONE Reference bmuter D RAWN BY: DESIG N I NFO RMATI ON ENG I NEER: AP PRO VED : REFERENCE: EQ UIP M ENT ...

  • Lincoln Electric VANTAGE SVM178-B - page 268

    ELEcTricaL DiaGramS G-10 v aNTaGE® 500 SchEma Tic - cOmpLETE machiNE - G4848 (cODES 1 1180, 1 1415 & 11468 DEuTz) paGE 1 G4848 VA NTA GE 500 DE UT Z MAC HI N E SC HEM ATIC NONE G4487 B. M UTER N.S. DO NO T SC AL E T HIS DR A WING D RAWN BY: DESIG N I NFO RMATI ON ENG I NEER: AP PRO VED : EQ UIP M ENT TYPE: SUBJECT: SCA L E: UF CRM36466 1 PAGE ...

  • Lincoln Electric VANTAGE SVM178-B - page 269

    ELEcTricaL DiaGramS G-11 v aNTaGE® 500 SchEma Tic - cOmpLETE machiNE - G4848 (cODES 1 1180, 1 1415 & 11468 DEuTz) paGE 2 G4848 VA NTA GE 500 DE UT Z MAC HI N E SC HEM ATIC NONE G4487 B. M UTER N.S. DO NO T SC AL E T HIS DR A WING D RAWN BY: DESIG N I NFO RMATI ON ENG I NEER: AP PRO VED : EQ UIP M ENT TYPE: SUBJECT: SCA L E: UF CRM36466 2 PAGE ...

  • Lincoln Electric VANTAGE SVM178-B - page 270

    ELEcTricaL DiaGramS G-12 v aNTaGE® 500 SchEma Tic - cOmpLETE machiNE - G4791 (cODES 1 1181 & 11416 cummiNS) p aGE 1 G-12 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return t ...

  • Lincoln Electric VANTAGE SVM178-B - page 271

    ELEcTricaL DiaGramS G-13 v aNTaGE® 500 SchEma Tic - WELD cONTrOL BOarD - G4108 p aGE 1 G-13 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric VANTAGE SVM178-B - page 272

    ELEcTricaL DiaGramS G-14 v aNTaGE® 500 SchEma Tic - WELD cONTrOL BOarD - G4801-1 p aGE 2 G-14 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master T ...

  • Lincoln Electric VANTAGE SVM178-B - page 273

    ELEcTricaL DiaGramS G-15 v aNTaGE® 500 SchEma Tic - WELD cONTrOL BOarD - G4801-1 p aGE 3 G-15 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master T ...

  • Lincoln Electric VANTAGE SVM178-B - page 274

    ELEcTricaL DiaGramS G-16 v aNTaGE® 500 SchEma Tic - WELD cONTrOL BOarD - G4801-1 p aGE 4 G-16 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master T ...

  • Lincoln Electric VANTAGE SVM178-B - page 275

    ELEcTricaL DiaGramS G-17 v aNTaGE® 500 SchEma Tic - WELD cONTrOL BOarD - p aGE 5 G-17 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Retur ...

  • Lincoln Electric VANTAGE SVM178-B - page 276

    ELEcTricaL DiaGramS G-18 v aNTaGE® 500 SchEma Tic - chOppEr pc BOarD - m19792-1 G-18 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return ...

  • Lincoln Electric VANTAGE SVM178-B - page 277

    ELEcTricaL DiaGramS G-19 v aNTaGE® 500 SchEma Tic - pEriphEraL BOarD - G3663 G-19 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to ...

  • Lincoln Electric VANTAGE SVM178-B - page 278

    ELEcTricaL DiaGramS G-20 v aNTaGE® 500 SchEma Tic puLL cOiL/Ba TTEry BOarD - G41 17-1 G-20 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

Fabricant Lincoln Electric Catégorie Welding System

Les documents que nous recevons du fabricant de l'appareilLincoln Electric VANTAGE SVM178-B peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lincoln Electric
- manuels d’utilisations VANTAGE SVM178-B
- fiches produit Lincoln Electric
- dépliants
- ou étiquettes-énergie Lincoln Electric VANTAGE SVM178-B
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lincoln Electric VANTAGE SVM178-B.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lincoln Electric VANTAGE SVM178-B, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lincoln Electric VANTAGE SVM178-B. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lincoln Electric VANTAGE SVM178-B.

Manuel d’utilisation complet de l’appareil Lincoln Electric VANTAGE SVM178-B, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lincoln Electric VANTAGE SVM178-B par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lincoln Electric VANTAGE SVM178-B.

Le manuel d’utilisation complet Lincoln Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lincoln Electric VANTAGE SVM178-B - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lincoln Electric VANTAGE SVM178-B, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLincoln Electric VANTAGE SVM178-B qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lincoln Electric VANTAGE SVM178-B - qui devraient nous aider dans les premières étapes lors de l'utilisation Lincoln Electric VANTAGE SVM178-B
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lincoln Electric VANTAGE SVM178-B
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lincoln Electric VANTAGE SVM178-B dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lincoln Electric VANTAGE SVM178-B?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lincoln Electric VANTAGE SVM178-B, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lincoln Electric VANTAGE SVM178-B il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)