    TM 1 Hotwire 5216 Remote T ermination Unit (RTU) Customer Premises Installation Instructions Document Number 5216-A2-GN10-10 February 1998 Before Y ou Begin An optional POTS (Plain Old T elephone Service) splitter is available for the 5216 RTU. When a POTS splitter is installed, the telephone and 5216 RADSL (Rate Adaptive Digital Subscriber Line) R ...

  • Paradyne 5216 - page 2

    2 Package Checklist V erify that your package contains the following: - Model 5216 Remote T ermination Unit (RTU) - DSL interface cable with RJ1 1 modular plugs - Power cord with power transformer - T wo ferrite chokes - W arranty card Refer to Cables & Connectors , page 13, for standard pin numbers. What Does the Hotwire R TU Do? The 5216 RTU ...

  • Paradyne 5216 - page 3

    3 When a POTS splitter is used at both ends of the local loop, wiring is connected: H From the demarcation point to the CP POTS splitter , and H From the demarcation point to the DSL jack. 97-15608 Punchdown Block or NID DSL Jack RT U New Wiring Connections Existing Wir ing (PO TS) Customer Premises (CP) DSL Ethernet Crossov er Cable Central Office ...

  • Paradyne 5216 - page 4

    4 DSL Access without a POTS Splitter When the 5216 RTU is installed without a POTS splitter , a second telephone wiring pair is needed for DSL access. 97-15609 Punchdown Block or NID DSL Jack RT U Customer Premises (CP) PO TS DSL Ethernet Crossov er Cable Central Office (CO) Demarcation P oint Local Loop New Wiring Connections Existing Wir ing (PO ...

  • Paradyne 5216 - page 5

    5 Installing the DSL Access Wiring The local loop terminates at the punchdown block or NID. Wiring must be connected from the customer premises side of the punchdown block or the NID to the DSL jack. T ypically , the punchdown block is installed in commercial locations and the NID is installed in residential locations. " Procedur e 1. Access t ...

  • Paradyne 5216 - page 6

    6 Green (T1) and red (R1) are the standard wiring colors used in the next two illustrations. In the following example, a NID is used without a POTS splitter . It includes an existing POTS line and a second pair installed for DSL access. The POTS pair for the existing POTS line wiring does not need to be disconnected unless a POTS splitter is going ...

  • Paradyne 5216 - page 7

    7 2. Locate the DSL pair of T1/R1 connectors on the customer premises side of the NID or punchdown block. Attach the wiring that will be connected to the DSL jack. T ighten both terminal screws with a flat-blade screwdriver . DSL/PO TS Access from Local Loop Wiring to DSL Jac k T elephone Network Interface Device (NID) Ground Tip T1 (Green) Ring R1 ...

  • Paradyne 5216 - page 8

    8 DSL Jack Installation The 5216 RTU connects to the local loop via wiring from the demarcation point to an RJ1 1 wall jack. The DSL twisted-pair wiring from the local loop terminates at a new or existing wall jack. It may be necessary to install a standard single RJ1 1 jack or replace a single jack with a double RJ1 1 jack. The RJ1 1 6-pin jack us ...

  • Paradyne 5216 - page 9

    9 Installing the R TU Place the 5216 RTU on a flat surface with clearance for the rear connectors. " Procedur e 1. Use the RJ1 1 6-pin cable for the DSL connection. Insert one end of the cable into the jack labeled DSL. Insert the other end into the wall jack labeled DSL. 97-15300-01 DSL Jack POWER ETHERNET DSL Hotwire RTU 2. Use an 8-pin Ethe ...

  • Paradyne 5216 - page 10

    496-14952 97-15303c Ethernet Line PO WER ETHERNET DSL Hotwire RTU F err ite Choke 10 3. Place the large ferrite choke on the Ethernet cable as closely as possible to the RTU. Pass the Ethernet cable through the ferrite choke twice, creating a loop as shown. 4. Close the two halves around the cable and snap the ferrite choke shut. Press down on the ...

  • Paradyne 5216 - page 11

    11 6. Close the two halves around the cable and snap the ferrite choke shut. Press down on the plastic latch to secure the ferrite choke in place around the cable. 7. Plug the transformer into an AC outlet. The RTU hardware installation is now complete. When the power cord is installed, the RTU goes through a power-on self-test. Power -On When powe ...

  • Paradyne 5216 - page 12

    12 LED Status Condition DSL Blinking ON OFF RTU is establishing the DSL link. The LED blinks on and off about five times per second. The DSL link is now active and ready to transmit and receive data. The DSL link has not been established. ETHERNET ON OFF The Ethernet 10BaseT connection to the end-user system is active. No Ethernet 10BaseT device is ...

  • Paradyne 5216 - page 13

    97-15304 6- P i n RJ 1 1 Pl ug DS L Li ne Pi n #1 Pi n #6 13 LED Symptom Action DSL and Ethernet LEDs are on and there is no data transmission. The DSL link and the Ethernet link have been established. If the problem continues, contact the NSP . Ethernet LED is off. V erify that the Ethernet 10BaseT cable is securely installed at both ends, and tha ...

  • Paradyne 5216 - page 14

    14 H The Ethernet interface crossover cable connector uses an 8-pin, non-keyed modular plug. 97-15305 8- P i n Pl u g E t he r ne t Ca bl e Pi n #1 Pi n #8 10BaseT TX D + 10BaseT TX D  10BaseT R X D + No t Us ed No t Us ed 10BaseT R X D  No t Us ed No t Us ed 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 10BaseT TX D + 10BaseT TX D  10BaseT R X D + No t ...

  • Paradyne 5216 - page 15

    15 Model 5216 R TU T echnical Specifications Item Specification * Height x Width x Depth 1.35 ″ x 6.00 ″ x 8.75 ″ (3.43 cm x 15.35 cm x 22.23 cm) Weight 1 lb. 1 oz. (0.48 kg) Power Class 2 T ransformer normal service input voltage range Input: 100 V ac, 50 Hz; 120 V ac, 60 Hz; or 230 V ac, 50/60 Hz Output: 15 Vdc nominal (+ 10%), minimum 0.6A ...

  • Paradyne 5216 - page 16

    16 Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. T o ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. 3. Do n ...

  • Paradyne 5216 - page 17

    17 CE Marking When the product is marked with the CE mark on the equipment label, this demonstrates full compliance with the following European Directives: H Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within states relating to ...

  • Paradyne 5216 - page 18

    18 Declaration of Conformity This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2 and 15 of the Federal Communications Commission’s Rules. This compliance information statement pertains to the following products: T rade Name: Hotwire Model Number: 5216-A2-200 This device complies with Part 15 of the FCC Rules. Operat ...

  • Paradyne 5216 - page 19

    19 EMI W arnings ! W ARNING: T o Users of Digital Apparatus in Canada: This Class B digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la classe B respecte toutes les exigences du règlement sur le matérial brouilleur du Canada. Notice to Users of the Canadian T elephone ...

  • Paradyne 5216 - page 20

    20 W arranty , Sales, and Service Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty , sales, service, repair , installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the fol ...

Fabricant Paradyne Catégorie Network Router

Les documents que nous recevons du fabricant de l'appareilParadyne 5216 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Paradyne
- manuels d’utilisations 5216
- fiches produit Paradyne
- dépliants
- ou étiquettes-énergie Paradyne 5216
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Paradyne 5216.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Paradyne 5216, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Paradyne 5216. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Paradyne 5216.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Paradyne 5216, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Paradyne 5216 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Paradyne 5216.

Le manuel d’utilisation complet Paradyne, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Paradyne 5216 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Paradyne 5216, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lParadyne 5216 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Paradyne 5216 - qui devraient nous aider dans les premières étapes lors de l'utilisation Paradyne 5216
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Paradyne 5216
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Paradyne 5216 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Paradyne 5216?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Paradyne 5216, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Paradyne 5216 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)