Manuel d’utilisation Cabletron Systems 9T428-16

40 pages 0.44 mb
Télécharger

Aller à la page of 40

Summary
  • Cabletron Systems 9T428-16 - page 1

    9032172-04 SmartSwitch 9000 9T425-16, 9T427-16, and 9T428-16 Token Ring Module User’s Guide ...

  • Cabletron Systems 9T428-16 - page 2

    ...

  • Cabletron Systems 9T428-16 - page 3

    i Notice Notice Cabletron Systems r eserves the right to make changes in speciÞcations and other information contained in this document without prior notice. The reader should in all cases consult Cabletr on Systems to determine whether any such changes have been made. The hardwar e, Þrmware, or softwar e described in this manual is subject to ch ...

  • Cabletron Systems 9T428-16 - page 4

    ii Notice FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference r eceived, including interference that may cause undesir ed operation. NOTE: This equipment has been tested and found to c ...

  • Cabletron Systems 9T428-16 - page 5

    iii Notice DECLARA TION OF CONFORMITY Application of Council Directi ve(s): 89/336/EEC 73/23/EEC Manufacturer’ s Name: Cabletron Systems, Inc. Manufacturer’ s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representati ve Name: Mr. J. Solari European Representati ve Address: Cabletron Systems Limited Nexus House, Newbury Bu ...

  • Cabletron Systems 9T428-16 - page 6

    Notice iv ...

  • Cabletron Systems 9T428-16 - page 7

    v Contents Chapter 1 Intr oduction Features........................................................................................................................... 1-1 Related Manuals ............................................................................................................ 1-4 Getting Help ..................................... ...

  • Cabletron Systems 9T428-16 - page 8

    Notice vi Chapter 5 Specifications Safety ............................................................................................................................... 5-1 Service ............................................................................................................................. 5-1 Physical ............................ ...

  • Cabletron Systems 9T428-16 - page 9

    1-1 Chapter 1 Intr oduction The 9T425-16, 9T427-16, and 9T428-16 T oken Ring SmartSwitch 9000 ª Modules are Enterprise Backbone switches supporting Smart Networking Services, RMON per port and Dedicated T oken Ring. The 9T425-16, 9T427-16, and 9T428-16 modules (shown in Figure 1-1) pr ovide sixteen ports, either UTP or STP for the 9T425-16 and 9T4 ...

  • Cabletron Systems 9T428-16 - page 10

    Introduction 1-2 Figure 1-1. The 9T425-16, 9T427-16, and 9T428-16 SmartSwitch 9000 Modules TOKEN RING 9T427-16 STN Mb/s LED MODE 5 6 7 8 1 2 3 4 11 12 13 14 15 16 9 10 TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX ...

  • Cabletron Systems 9T428-16 - page 11

    1-3 Introduction P acket Switching Packet Switching occurs between the front panel T oken Ring connections and/or to any other module in the chassis via the INB2 bus. These modules are capable of T ransparent Bridging or Sour ce Route T ranslational Bridging. IEEE 802.1d Spanning T ree Pr otocol is supported in all bridging functions. Source Route ...

  • Cabletron Systems 9T428-16 - page 12

    Introduction 1-4 SFVLAN (SecureF ast Vir tual LANS) The 9T425-16, 9T427-16, and 9T428-16 allow connection-orientated Switched V irtual Circuits (SVC). Protocol T ranslations The 9T425-16, 9T427-16, and 9T428-16 allow Òany-to-anyÓ connectivity for IPX, IP , SNA, Netbios, Appletalk protocols between T oken Ring and Ethernet, FDDI, and Fast Ethernet ...

  • Cabletron Systems 9T428-16 - page 13

    1-5 Introduction Getting Help For additional support related to this device or document, contact Cabletr on Systems using one of the following methods: Before calling Cabletron Systems, have the following information ready: ¥ Y our Cabletr on Systems service contract number ¥ A description of the failure ¥ A description of any action(s) already ...

  • Cabletron Systems 9T428-16 - page 14

    Introduction 1-6 ...

  • Cabletron Systems 9T428-16 - page 15

    2-1 Chapter 2 Installation Installing the Smar tSwitc h 9000 Module The SmartSwitch 9000 module may be installed into any two available slots. T o install, follow the steps below: 1. Remove the blank panels covering the slots that the module is being mounted in. All other slots must be cover ed if modules are not being installed, to ensur e proper ...

  • Cabletron Systems 9T428-16 - page 16

    Installation 2-2 Figure 2-1. Installing the Smar tSwitch 9000 Module 7 F LN K 8 F LN K F LN K 10 F LN K I NS 11 F LN K I NS 12 RX TX RX TX RX Circuit Card Card Guides Metal Back-Panel Receptacle for ESD wrist strap W arning: Ensure that the circuit card is between the card guides . Lock do wn the top and bottom plastic tabs at the same time, applyi ...

  • Cabletron Systems 9T428-16 - page 17

    2-3 Installation The Reset Switch The Reset switch is located on the front panel, under the top plastic tab as shown in Figure 2-2. It serves two functions: ¥ Pressing the r eset switch twice within three seconds causes the pr ocessor (i960) to reset. ¥ Pressing and holding the switch for thr ee or more seconds causes the module to shutdown. Pres ...

  • Cabletron Systems 9T428-16 - page 18

    Installation 2-4 Setting the Module Car d DIP Switch An eight position DIP switch is located just under the edge of the top module car d as shown in Figure 2-3. The functions of the switch ar e listed in T able 2-1. Figure 2-3. Location of Module DIP Switch 1 2 3 4 5 6 7 8 ...

  • Cabletron Systems 9T428-16 - page 19

    2-5 Installation See the Cautions at the end of this table. T able 2-1. Functions of DIP Switch Switch Function Description 8 Clear Password 1 When toggled, this switch clears user-enter ed passwords stor ed in NVRAM, and restor es the default passwords. Once r eset you can use the defaults or enter new passwords. 7 Clear NVRAM 2 The module uses NV ...

  • Cabletron Systems 9T428-16 - page 20

    Installation 2-6 Fr ont P anel Cabling This section details the front panel cabling for the 9T425-16, 9T427-16, and 9T428-16 modules. The 9T425-16 and 9T427-16 Modules This section shows the pin-outs for wiring cable to the front panel RJ45 connectors. Station P ort Pins Figure 2-4 illustrates the signal assignments for RJ45 station port pins. Figu ...

  • Cabletron Systems 9T428-16 - page 21

    2-7 Installation Lobe P ort Pins Figure 2-5 illustrates the signal assignments for RJ45 lobe port pins. Figure 2-5. RJ45 Lobe P or t Pins – Signal Assignments The 9T428-16 Module T able 2-2 lists signal tolerance speciÞcations for the Multimode Fiber Optic cable used for front panel connections. The Fiber Optic cable segments have ST connectors. ...

  • Cabletron Systems 9T428-16 - page 22

    Installation 2-8 Figure 2-6. Connecting Fiber Optic cable to the 9T428-16 Recommended Cable Lengths The IEEE 802.5 speciÞcation does not specify a minimum lobe length in meters that a T oken Ring station must meet. Rather the standar d speciÞes Cable Attenuation, Signal to Crosstalk Noise Ratio (SCNR) and a Next Loss to Insertion Loss Ratio (NIR) ...

  • Cabletron Systems 9T428-16 - page 23

    2-9 Installation T able 2-3. 16 MBPS (Station Mode) - 9T425-16/9T427-16 Cable T ype Passive MAU (meters) Active MAU (meters) Category 3 UTP 55 100 Category 4/5 UTP 100 180 T ype 1 STP 200 300 T able 2-4. 4 MBPS (Station Mode) - 9T425-16/9T427-16 Cable T ype Passive MAU (meters) Active MAU (meters) Category 3 UTP 150 250 Category 4/5 UTP 250 350 T y ...

  • Cabletron Systems 9T428-16 - page 24

    Installation 2-10 Defaults When the module is installed, the parameters listed below are the defaults. These can be changed by Local Management or by SNMP management. Ring Speed (or Media Rate) Defaults to a 16Mbps ring speed. Ring Numbers Default to the T oken Ring port number (i.e., port 3 = ring number 3). If ÒAuto-Detect Ring NumberÓ is enabl ...

  • Cabletron Systems 9T428-16 - page 25

    3-1 Chapter 3 Operation The 9T425-16, 9T427-16, and 9T428-16 SmartSwitch 9000 Modules provide connectivity between the front panel T oken Rings and the INB2 backplane. SmartSwitch 9000 modules connect to either the Internal Network Bus (INB) or the Flexible Network Bus (FNB) bus. The 9T425-16, 9T427-16, and 9T428-16 modules connect only to the INB2 ...

  • Cabletron Systems 9T428-16 - page 26

    Operation 3-2 Figure 3-1. 9T425-16, 9T427-16, and 9T428-16 Block Dia gram All data packets destined for a front panel port, the INB, or the i960 ar e converted into the canonical format before forwar ding to the SmartSwitch 9000 ASIC. Network Interface Blocks (NIBs) check for valid data packets entering the system. If an error ed data packet is fou ...

  • Cabletron Systems 9T428-16 - page 27

    3-3 Operation Switching The 9T425-16, 9T427-16, and 9T428-16 operate as a Source Route T ranslational (SR-TB) switch. They provide translation to transpar ent frames. For information on conÞguring the switching function, see the addendum to the SmartSwitch 9000 Local Management User Õs Guide, containing information speciÞc to this model. All SR ...

  • Cabletron Systems 9T428-16 - page 28

    Operation 3-4 Sour ce Route and Sour ce Route T ranslational Switching In SR (Source Routing) and SR T (Source Route and T ransparent) modes, the received SR packets ar e stripped of their RIF during the translation to canonical frame format. Packets that are queued for transmission out the T oken Ring port can have a RIF inserted from the RIF cach ...

  • Cabletron Systems 9T428-16 - page 29

    3-5 Operation Spanning T ree Algorithm is a hierarchy (or tr ee) of priorities that bridges establish between themselves. This hierarchy guarantees that primary and r edundant data paths are clearly deÞned at all times, so that the network is continuously available to users. In a multiple bridge environment, one bridge in the network establishes i ...

  • Cabletron Systems 9T428-16 - page 30

    Operation 3-6 System Diagnostic Contr oller This diagnostic controller is composed of a Z-80 micr oprocessor and its supporting logic. The diagnostic controller is designed to contr ol the power-up sequencing of modules, monitor the 9T425-16, 9T427-16, and 9T428-16 input and output power parameters, keep watch over the main host processor , as well ...

  • Cabletron Systems 9T428-16 - page 31

    3-7 Operation learning. When operating in SecureFast Switch mode, all Þltering/forwar ding decisions are made based on a DA-SA pair and its receive port. The SmartSwitch 9000 hub can support modules operating in traditional switch mode and SecureFast Switch mode simultaneously . This pr ovides security when-and-where needed, and ease-of-conÞgurat ...

  • Cabletron Systems 9T428-16 - page 32

    Operation 3-8 ...

  • Cabletron Systems 9T428-16 - page 33

    4-1 Chapter 4 LANVIEW LEDs The front panel LANVIEW LEDs, shown in Figur e 4-1, indicate the status of the module and may be used as an aid in troubleshooting. Figure 4-1. LANVIEW LEDs TOKEN RING S M B C P U INB Mb/s STN Mb/s Mode System Status INB T ransmit T oken Ring P or t T ransmit T oken Ring P or t Receiv e INB Receive P or t Speed Station Mo ...

  • Cabletron Systems 9T428-16 - page 34

    LANVIEW LEDs 4-2 The 9T427-16 also has a front panel mode switch, shown in Figur e 4-2, that changes the functions of the LEDs. Figure 4-2. 9T427-16 LEDs and Mode Switch TOKEN RING 9T427-16 STN Mb/s LED MODE 5 6 7 8 1 2 3 4 11 12 13 14 15 16 9 10 TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/s TX STN RX Mb/ ...

  • Cabletron Systems 9T428-16 - page 35

    4-3 LANVIEW LEDs The functions of the two System Status LEDs, System Management Bus (SMB) and the CPU, are listed in T able 4-1. The functions of the INB receive LED ar e listed in T able 4-2. The functions of the INB transmit LED are listed in T able 4-3. T able 4-1. System Status LEDs (SMB and CPU) LED Color State Description Green Functional Ful ...

  • Cabletron Systems 9T428-16 - page 36

    LANVIEW LEDs 4-4 The functions of the T oken Ring Port r eceive LEDs are listed in T able 4-4. The functions of the T oken Ring Port transmit LEDs ar e listed in T able 4-5. The functions of the Station Mode LEDs are listed in T able 4-6. T able 4-4. T oken Ring Receive LEDs LED Color State Green Insert, No activity , Port Enabled Y ellow (Flashing ...

  • Cabletron Systems 9T428-16 - page 37

    4-5 LANVIEW LEDs The Port Speed LEDs show a combination of Ring Speed and Access Protocol in use. The functions of the Port speed LEDs are listed in T able 4-8. * TXI is T ransmit I mmediate or Full Duplex operation. TKP is T o k en P assing or standard T oken Ring. T able 4-7. Mode LEDs (9T428-16 Only) LED Color State Green Port is ConÞgured as S ...

  • Cabletron Systems 9T428-16 - page 38

    LANVIEW LEDs 4-6 ...

  • Cabletron Systems 9T428-16 - page 39

    5-1 Chapter 5 Specifications Safety This equipment meets the safety requir ements of: ¥ UL 1950 ¥ CSA C22.2 No. 950 ¥ EN 60950 ¥ IEC 950 ¥ EMI Requirements of FCC Part 15 Class A ¥ EN 55022 Class A ¥ VCCI Class I ¥ EMC requir ements of: EN 50082-1 IEC 801-2 ESD IEC 801-3 Radiated susceptibility IEC 801-4 EFT Service MTBF (MHBK-217E) >20 ...

  • Cabletron Systems 9T428-16 - page 40

    Specifications 5-2 Ph ysical Dimensions 35.0 D x 44.0 H x 6.0 W centimeters (13.8 D x 17.4 H x 2.4 W inches) W eight Unit: 1.4kg. (3lb) 9T427-16 2.7kgs. (6lbs.) 9T425-16 & 9T428-16 Shipping: 1.81kg. (4lbs.) 9T427-16 3.6kgs. (8lbs.) 9T425-16 & 9T428-16 Electrical CPU: i960 Local DRAM Memory: 20Mb (expandable to 48Mb) Flash: 4Mb (expandable ...

Fabricant Cabletron Systems Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilCabletron Systems 9T428-16 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cabletron Systems
- manuels d’utilisations 9T428-16
- fiches produit Cabletron Systems
- dépliants
- ou étiquettes-énergie Cabletron Systems 9T428-16
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cabletron Systems 9T428-16.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cabletron Systems 9T428-16, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cabletron Systems 9T428-16. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cabletron Systems 9T428-16.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Cabletron Systems 9T428-16, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cabletron Systems 9T428-16 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cabletron Systems 9T428-16.

Le manuel d’utilisation complet Cabletron Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cabletron Systems 9T428-16 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cabletron Systems 9T428-16, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCabletron Systems 9T428-16 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cabletron Systems 9T428-16 - qui devraient nous aider dans les premières étapes lors de l'utilisation Cabletron Systems 9T428-16
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cabletron Systems 9T428-16
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cabletron Systems 9T428-16 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cabletron Systems 9T428-16?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cabletron Systems 9T428-16, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cabletron Systems 9T428-16 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)