Manuel d’utilisation IMC Networks iMcV-T1/E1/J1

21 pages 3.22 mb
Télécharger

Aller à la page of 21

Summary
  • IMC Networks iMcV-T1/E1/J1 - page 1

    iMcV-T1/E1/J1 Operation Manual ...

  • IMC Networks iMcV-T1/E1/J1 - page 2

    FCC Radio Frequency Interference Statement This equipment has been tested and found to comp ly with the limi ts for a Class B computi ng device, pursuant to Part 15 of the F CC Rules. These limits are designed to provide reasona ble protection agains t har mful interferenc e when the equi pment is operated in a com merc ial environment. This equi p ...

  • IMC Networks iMcV-T1/E1/J1 - page 3

    Table of Content s FCC Radio Frequency Interference Stateme nt .................................................... ii Warranty ............................................................................................................ ii About th e iMcV-T1/E 1/J1 ...................................................................................4 ...

  • IMC Networks iMcV-T1/E1/J1 - page 4

    About the iMcV-T1/E 1/J1 The i McV-T1/ E1/J1™ chass is mou nted medi a conversion module allows you to extend the distances between T1, J1, and E1 co pper telephony systems by addi ng a fiber segmen t. The d istances you can add ran ge from 2 km to 100km dependin g on the module used an d the fiber t ype available. Contents This box contains t he ...

  • IMC Networks iMcV-T1/E1/J1 - page 5

    Configuration The iMcV-T1/E 1/J1 module is factory-configur ed to use the fo llowing defa ult features : • T1/ E1 Mo de .................................................................................................... T1 • Receive Equalizer Gain Limit ( EGL) : .......................-30 dB (L imi ted Lon g Ha ul) • Line Encoding : ........ ...

  • IMC Networks iMcV-T1/E1/J1 - page 6

    Available configurations enable d by DIP switches (and iView 2 ): T1 Mode Configurations (default) • Receive Equalizer Gain Limit (EGL) iView 2 o -36 dB (Long Haul) o -30 dB (Limited Long Haul) (default) • Line Encoding iView 2 o B8ZS o AMI (default) • Transmit LIU Waveshape (Build-out) o DSX-1 (0 to 133 ft) 0 dB CSU (default) o DSX-1 (133 to ...

  • IMC Networks iMcV-T1/E1/J1 - page 7

    Installation At the central location the iMc V-T1/E1/J1 unit is typically install ed in a managed chassis su ch as the iMediaChassis or the iMediaCenter . iMediaChassis iMediaCenter 7 ...

  • IMC Networks iMcV-T1/E1/J1 - page 8

    MediaChassis The MediaCha ssis provides a ty pical unmanaged chassis suitable for all r emote installation locations. NOTE Chassi s may also be available in Industria l Ethernet (I E) configur ations. Each modul e requires on e slot i n the chassis. To install a mo dule, rem ove the blank brackets cov ering th e slots whe re the mo dule is to be in ...

  • IMC Networks iMcV-T1/E1/J1 - page 9

    DIP Switch Tabl e T1/E1 Se lection S2-1: OFF T1 Mode Selected default S2-1: ON E1 Mode Selected Receive Equalizer Gain Limit (EGL) E1 iVIEW 2 S2-2: ON -12 dB (Short Haul) iVIEW 2 S2-2: OFF -43 dB (Long Haul) iVIEW 2 T1 iVIEW 2 S2-2: ON -36 dB (Long Haul) iVIEW 2 S2-2: OFF -30 dB (Limited Long Haul ) iVIEW 2 default Line Encodin g iVIEW 2 iVIEW 2 S2 ...

  • IMC Networks iMcV-T1/E1/J1 - page 10

    10 ...

  • IMC Networks iMcV-T1/E1/J1 - page 11

    Unmanaged Modules Before installing the i McV-T1/E1/J1 modul e into an unmanaged chassis, configure the module hard ware-sel ectable featur es via DIP switches loca ted at positi on S3 and S2 on the PCB (refer to t he DIP Switch Table section for more infor mation). The jumpers located at positions J P1 and JP2 are factory configured— DO NOT CHAN ...

  • IMC Networks iMcV-T1/E1/J1 - page 12

    Receive LIU Termination (Line Termination) This opt ion allows you to se t the rece ive term ination. T his is used to properly terminate c ables in order t o prevent signal r eflections w hich can cause sign al degradation. Transmit Data Source This opt ion allows you to se t the module to se nd no rmal data (def ault) or to send specif ic tes t-p ...

  • IMC Networks iMcV-T1/E1/J1 - page 13

    Remote Ma nage ment This option allo ws you to enable R emote management on the modul e. The re mote manageme nt fea ture i s desig ned to work only on th e remote modu le of the Local/Remote pair . With Remote management enabled, you can e asily perform the following: • Test t he line integ rity of the remote copper port. • Use the Local unit ...

  • IMC Networks iMcV-T1/E1/J1 - page 14

    Module LED Functions This sec tion desc ribes th e LEDs and their f u nctions. The Fiber port LED RM is the only LED t hat should b e lit on th e modules under normal operating c onditions. Copper Port LEDs LPBK Glows gr een when the mo dule is set t o one of the Loopback mode s. NO LNK Glows green when a UTP link is NOT established. PBEO Only used ...

  • IMC Networks iMcV-T1/E1/J1 - page 15

    Testing To test a media converter by itself, first make sure y ou have an appropriate fi ber patch cable, then perform the following ste ps: 1. Connect t he media c onverter t o the T1/E1 device wit h a standar d UTP cable. I f the NO LNK LED for the copper port remains on, you are n ot receiving a valid signal. Push the cross over push button on t ...

  • IMC Networks iMcV-T1/E1/J1 - page 16

    The iMcV-T1/E 1/J1 can be configured to use the foll owing loopback test modes: • Local Fiber Loopbac k Mode This set ting te sts the path from the CO coppe r port to the Local iMcV -T1/E1/ J1 module fiber port an d back. • Remote Fiber Loopba ck Mode This set ting te sts the path from the CO coppe r port to the Remote iMcV-T 1/E1/J1 module fib ...

  • IMC Networks iMcV-T1/E1/J1 - page 17

    Remote Fiber Loopback Mode To se t the loopback testing m ode to Remote Fiber Loo pback Mode , perfo rm the following: 1. Set the Local iMcV-T1/E1/J 1 module Loopback to None (DIP switch S3-3=On and S3-4=On) 2. Set the Remote iMcV -T1/ E1/J1 mod ule to Local Loopback (DIP switch S3-3= Off and S3-4= On). This co nfiguratio n allows yo u to test the ...

  • IMC Networks iMcV-T1/E1/J1 - page 18

    Testing with Pseudorandom Bit Sequence (PRBS) To test the copper segment from the Remote module to the Customer Prem ises Equipment (CPE) by us ing PRBS, perfor m the following: 1. Set the CPE to l oopback the signal. 2. Set the Remote module to genera te PRBSs (DIP switch S2-9=On an d S2-10=Off). Check the LEDs to verify errors are not re ceived ( ...

  • IMC Networks iMcV-T1/E1/J1 - page 19

    Specifications Power Cons umption (Typi cal): 0.550 Amp Operatin g Temperatur e: 32° to 122° F ( 0° to 50° C) Storage Te mperature : 0° to 160°F (-20° t o 70° C) Humidity: 5 to 95% (non-co ndensing); 0 to 10,000 ft. altitude Dime nsions : Single Slot iMcV module Fiber Optic Specifications For fiber optic specifications, vi sit our Web site ...

  • IMC Networks iMcV-T1/E1/J1 - page 20

    Saf ety C ertif icat ion s UL/CUL: Listed to Safety of Informati on Technology Equip ment, including Electrical Busin ess Equipm ent. CE: The p roducts de scribed herein comply wi th the C ouncil Dire ctive on Electromagne tic Compatibility (89/33 6/EEC) and the Council Directive on Electrical Eq uipment Design ed for use within Certain Voltage Li ...

  • IMC Networks iMcV-T1/E1/J1 - page 21

    19772 Pauling • Foothill Ranch, CA 926 10-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetwork s.com © 2007 IMC Networks. Al l rights reserved The informatio n in this documen t is subje ct to ch ange with out noti ce. IMC Networks assumes no respo nsibility f or any errors t hat may appear i n this document. iMcV-T1/E 1/J1 is a t ...

Fabricant IMC Networks Catégorie Network Router

Les documents que nous recevons du fabricant de l'appareilIMC Networks iMcV-T1/E1/J1 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques IMC Networks
- manuels d’utilisations iMcV-T1/E1/J1
- fiches produit IMC Networks
- dépliants
- ou étiquettes-énergie IMC Networks iMcV-T1/E1/J1
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation IMC Networks iMcV-T1/E1/J1.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation IMC Networks iMcV-T1/E1/J1, manuels d’entretien, brefs manuels ou manuels de l’utilisateur IMC Networks iMcV-T1/E1/J1. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit IMC Networks iMcV-T1/E1/J1.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil IMC Networks iMcV-T1/E1/J1, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser IMC Networks iMcV-T1/E1/J1 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs IMC Networks iMcV-T1/E1/J1.

Le manuel d’utilisation complet IMC Networks, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel IMC Networks iMcV-T1/E1/J1 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières IMC Networks iMcV-T1/E1/J1, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lIMC Networks iMcV-T1/E1/J1 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil IMC Networks iMcV-T1/E1/J1 - qui devraient nous aider dans les premières étapes lors de l'utilisation IMC Networks iMcV-T1/E1/J1
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de IMC Networks iMcV-T1/E1/J1
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service IMC Networks iMcV-T1/E1/J1 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de IMC Networks iMcV-T1/E1/J1?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec IMC Networks iMcV-T1/E1/J1, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec IMC Networks iMcV-T1/E1/J1 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)