Manuel d’utilisation Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72

90 pages 2.55 mb
Télécharger

Aller à la page of 90

Summary
  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 1

    7.5x9-inch cover with bleed on 4 sides Enterasys Matrix ® DFE-Gold Series Hardware Installation Guide Module 4H4282-49 Module 4H4283-49 Module 4H4203-72 Module 4H4202-72 Module 4H4284-49 P/N 9033906-05 ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 2

    ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 3

    i Notice Enterasys Networks  reserv es  the  right  to  make  changes  in  specif ications  and  othe r  information  contained  in  this  document  and  its  web  si te  without  prior  notice.  The  reader  should  in  all  cases  consult  Enterasys Netw ork ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 4

    ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This  device  co mplies  with  Par t  15  of  the  FCC  rules.  Operation  is  subject  to  the  following  two  conditions:  (1)  this  devic e  may  not  cause  harmfu l  interference,  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 5

    iii Electromagnetic Compatibility (EMC) This  product  complies  with  the  following:  47  CF R  Pa r t s  2  and  15,  CSA  C108.8,  2004/108/EC,  EN  55022,  EN  61000 ‐ 3 ‐ 2,  EN 61000 ‐ 3 ‐ 3,  EN  55024,  AS/NZS  CISPR  22,  VCCI  V ‐ 3.  Compatibilida ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 6

    iv Enterasys  Customer  Support  at  353  61  705586  (Ireland). ѻ ѻ ક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼៪ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 &U   ໮⒈㘨㣃 3%% ໮⒈Ѡ㣃䝮  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 7

    v VCCI Notice This  is  a  class  A  product  based  on  the  standard  of  the  Vo l u n t a r y  Control  Co uncil  for  Interfe rence  by  Information  Te c h n o l o g y  Equipment  (VCCI).  If  this  equipmen t  is  used  in  a  dome stic  environment , ? ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 8

    vi Safety Information Class 1 Laser Transceivers The single mode interf ace modules use Class 1 la ser transceivers. Read the followi ng safe ty information befor e installing or o perating these modules. The  Class  1  laser  transceivers  use  an  optical  feedback  loop  to  maintain  Class  1  operation ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 9

    vii ENTERASYS NETWORKS, INC. FIRMWARE LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This  document  is  an  agreement  (“ Agreement”)  betwee n  the  end  user  (“Y ou”)  and  Enterasys  Net works,  Inc.,  on  behalf  of  itsel ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 10

    viii 3. APPLICABLE  LAW. This  Agreem ent  shal l  be  interpreted  and  governed  under  the  laws  and  in  the  state  and  federal  cour ts  of  th e  Commonwealth  of  Massachusetts  without  regard  to  its  conflicts  of  laws  provisions.  You  a ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 11

    ix 8. AUDIT  RIGHTS. You  here by  acknowled ge  that  the  intell ectual  property  rights  associated  with  the  Program  are  of  critical  value  to  Enterasys,  and,  accordingly,  You  hereby  agree  to  maintain  complete  books,  records  and  account ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 12

    x ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 13

    xi Contents About This Guide Who Should Use This G uide .............. ................. ............ ................. ............. ................ ............ ....... ... xv How to Use This G uide ............. ................ ............. ............. ................ ............. ................ ..... ............. xvi Related Documents ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 14

    xii Connecting to COM Port for Local Management ... ............. ................ ............. ................ ............. ... 3-20 What Is Needed ........ ............. ................ ............. ............. ............. ................ ............. ....... ......... 3-20 Connecting to an IBM PC or Co mpatible Device ............. .. ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 15

    xiii Figures 1-1 4H4282-49, 4H4283-49, and 4H4203-72 DFE-Gold Modules .......... ............. ................ ............... 1-4 1-2 4H4202 -72 and 4H4284-49 DFE-Gold Modules .... ............. ................ ............. ................ ............ 1-5 3-1 Examples, Slot Numbers/Module Placement in Ma trix E7 Chassi s ..................... ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 16

    xiv Tables 3-1 Contents of DFE-Gold Module Carton .............. ......... ............. ............. ................ ............. ............ 3-2 4-1 LANVIEW LEDs ................... ............. ................ ............. ................ ............. ............. ......... ............ 4-5 4-1 Troubleshooting Checklist ... ......... . ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 17

    Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide xv About This Guide This  guide  prov ides  an  over view ,  installati on  and  troubleshooting  instructions,  and  specifications  for  the  Enterasys  Matr ix ®  DFE ‐ Gold  4H42 82 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72 ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 18

    How to Use This Guide xvi About This Guide How to Use This Guide This  preface  provides  an  overview  of  this  guide  and  the  DFE ‐ Gold  Series  manual  set,  and  a  brief  summary  of  each  chapter;  de fines  the  conv entions  used  in  this  document;  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 19

    Conventions Used in This Guide Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide xvii Conventions Used in This Guide The  following  conventions  are  used  in  this  guide: Lowercase  x :  Indicates  the  general  use  of  an  alphanumeric  character  (for  example,  6x1xx ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 20

    Getting Help xviii About This Guide Getting Help For  additional  support  related  to  the  modules  or  this  document,  contact  Enterasys Network s  using  one  of  the  following  methods: Before  contacti ng  Enterasys Networks  for  technical  support,  have  the  fol ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 21

    Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-1 1 Introduction This  chapter  provides  an  overview  of  the  DFE ‐ Gold  module  capabilities,  and  introduces  the  4H4282 ‐ 49,  4H428 3 ‐ 49,  4H4203 ‐ 72,  4H4202 ‐ 72,  and  4H4284 ‐ 49  DFE ‐ Gold ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 22

    The DFE-Gold Modules 1-2 Introduction • Support  for  a  var i e t y  of  converged  applications  includ ing  Vo I P  with  Pow er ‐ over ‐ Ethernet  The DFE-Gold Modules This  section  provides  an  overview  of  the  4H4282 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72  ( Figure 1 ‐ ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 23

    The DFE-Gold Modules Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-3 full ‐ duplex  mode  of  operation.  The  duplex  mode  can  be  determined  by  either  auto ‐ negotiation  or  manual  configuration.  4H4202-72 The  4H4202 ‐ 72  has  72,  10BASE ‐ T/10 ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 24

    The DFE-Gold Modules 1-4 Introduction Figure 1- 1 4H4282-49, 4H42 83-49, and 4H4203-72 DFE-Gold Module s 1 OFFLINE/RESET button 6 GROUP status LEDs 2 RJ45 COM (Console Port) 7 GROUP select LEDs 3 CPU LED 8 4H4282-49 / 4H4283-49 - N EM option slot 4 MGMT LED 4H4203-72 - Ports (1-72), 10/100, through six RJ21s 5 GROUP SELECT button 9 4H4282-49 - Port ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 25

    The DFE-Gold Modules Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-5 Figure 1-2 4H4202-72 and 4H4284-49 DF E-Gold Mo dules 1 OFFLINE/RESET switch 6 GROUP select LEDs 2 RJ45 COM (Console Port) 7 GROUP SELECT button 3 CPU LED 8 GROUP status LEDs 4 MGMT LED 9 4H4202-72 - Groups 1&2, 48 Ports, 10/100, through RJ45s 4H4284-4 ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 26

    Connectivity 1-6 Introduction Connectivity 4H4282-49 Depending  on  how  the  4H4282 ‐ 49  ( Figure 1 ‐ 1 )  is  configured,  it  can  support  up  to: • 48,  10BASE ‐ T/100BASE ‐ TX  sw itched  ports  connected  through  48  fixed,  RJ45  front ‐ panel  connectors,  o ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 27

    Management Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-7 Management Management  of  the  module  can  be  either  in ‐ band  or  out ‐ of ‐ band.  In ‐ band  remote  management  is  possible  us ing  Te l n e t ,  Enterasys Networks’  NetSight ®  manageme ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 28

    LANVIEW Diagnostic LEDs 1-8 Introduction •N e t w o r k  Services  are  logical  groups  of  Classification  Rules  that  identify  specif ic  networked  applic ations  or  se rvices.  Users  may  be  permitted  or  deni ed  access  to  these  services  based  on  th ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 29

    Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 2-1 2 Network Requirements Before  inst alling  the  module,  re view  the  requirements  and  specificat ions  referred  to  in  this  chapter  concerning  the  following: • 10BASE ‐ T  Netw ork  (page 2 ‐ 1) • 100BASE ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 30

    100BASE-TX Network 2-2 Network Requirements 100BASE-TX Network Fixed  front  pane l  ports  of  the  4 H4282 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72,  and  4H4 202 ‐ 72 provide  a  connection  that  supports  Category  5  UTP  cabling.  The  device  at  the  other  end  of ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 31

    Matrix DFE-Gold Series Modules Hardware Installatio n Guide 3-1 3 Installation This  chapter  provides  the  instructions  to  install  the  4H4282 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72,  4H4202 ‐ 72,  and  4H4284 ‐ 49 DFE ‐ Gold modules. Follow  the  order  of  the  sections  li sted ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 32

    Installation Site Requirement 3-2 Installation Inst allation Site Requirement The  DFE ‐ Gold module  must  be  installed  in  a  Matrix  E7,  N1,  N3,  N5,  or  N7  chassis  located  in  a  Restricted  Access  Location  (RAL).  This  location  should  only  be  acce ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 33

    Installing Optional Netw ork Expansion Module Matrix DFE-Gold Series Modules Hardware Installatio n Guide 3-3 Inst alling Optional Network Exp ansion Module A  Phillips  screwdriver  is  required  to  install  an  optional  netw ork  expansio n  module  into  the  4H4282 ‐ 49,  4H428 3 ‐ 49,  or ? ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 34

    DFE Module Placement and Installation Rules 3-4 Installation To  ensure  proper  operation  of  the  system,  consider  the  following  examples  and  rules  for  module  placement  in  either  chassis. Example 1 ( Figure 3-1 , A) Shows  one  module  installed  in  the  chassis ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 35

    Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installatio n Guide 3-5 Example 3 ( Figure 3-1 , C) Shows  the  primary  management  module  missing  from  slot  1.  As  long  as  the  module  installed  in  slot  2  is  designated  as  a  redundant  manag ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 36

    Installing Module into a Chassis 3-6 Installation Prep aration 1. Remove  the  blank  pa nel  cov ering  the  slot  in  which  the  module  will  be  ins talled.  All  other  slots  must  remain  cov ered  to  ensure  proper  airflow  for  cooling.  (Save  the  blan ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 37

    Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installatio n Guide 3-7 2. Align  the  module  card  between  the  upper  and  lower  card  guides  of  the  desired  slot  and  sl ide  it  into  the  chassis,  taking  care  that  the  module  slid ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 38

    Installing Module into a Chassis 3-8 Installation Figure 3-2 Inst alling Module into Matr ix E7 or N7 Chassis (Matrix E7 sho wn) 1 Card guides 5 Upper/lower locking tabs (in proper open position) 2 Slot number 1(right-most slot is 7) 6 Upper/lower locking tab (in closed position) 3 Module card 7 Backplane connectors (power and FTM2) 4 Metal back p ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 39

    Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installatio n Guide 3-9 Inst alling Module into Matr ix N1, N3, or N5 Chassis A  DFE ‐ Gold module  can  be  installed  in  any  av ailable  chassis  slot  (1  through  3)  in  the  Matrix N3  chassis  or  slots  1  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 40

    Connecting to the Network 3-10 Installation Connecting to the Network For  connecting  unshielded  twisted  pair  (UTP)  segments  from  the  network  or  other  devices,  ref er  to • Connecting  UTP  Cables  to  4H4282 ‐ 49  or  4H4202 ‐ 72  (page 3 ‐ 11) • Connecting  UT ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 41

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-11 Connecting UTP Cables to 4H4282-49 or 4H4202-72 The  fixed  RJ4 5  front  panel  connections  of  the  4H4282 ‐ 49  and  4H4202 ‐ 72  are  10/100  Mbps  ports.  The  ports  have  internal  crosso ver ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 42

    Connecting to the Network 3-12 Installation 3. V erify  that  a  link  exists  by  ch ecki ng  that  the  port  RX  (Receive )  LED  is  ON  (flashing  amber ,  blinking  green,  or  solid  green).  If  the  RX  LED  is  OFF  and  the  TX  (T ransmit)  L ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 43

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-13 Figure 3-5 Four-Wire Crossover Cable RJ45 Pinout s, Connections Between Hub Devices 1 RJ45 device port 3 RJ45-to-RJ45 crossover cable 2 Other device port 4 RX+/RX- and TX+/TX- connections. These connections must share a common color pair . Figure 3-6 Four-Wire ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 44

    Connecting to the Network 3-14 Installation Figure 3-7 Eight-Wire Crossover Cable RJ45 Pinouts , Connections Between Hub Devices 1 RJ45 device port 3 RJ45-to-RJ45 crossover cable 2 Other device port Figure 3-8 Eight-Wire St raight-Throu gh Cable RJ45 Pinout s, Connections Between Sw itches an d End-User De vices 1 RJ45 device port 3 RJ45-to-RJ45 st ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 45

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-15 e. Ensure  that  the  twisted  pai r  connection  meets  the  dB  loss  and  cable  specifications  outlined  in  the  Cabling  Guide.  Refer  to   “Related  Documents”  on  page xvi ? ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 46

    Connecting to the Network 3-16 Installation 3. T o  install  an  RJ21  right ‐ angle  connector ,  refe r  to  Figure 3 ‐ 10  and  proceed  as  follows: a. If  using  an  optional  RJ21  angle  adapter  available  from  Enterasys  Networks,  insert  the  angle  adapte ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 47

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-17 Figure 3-10 Connection Using Optional RJ21 An gle Adapter 1 RJ21 angle adapter 5 Retaining clips 2 RJ21 port connector 6 GROUP SELECT button 3 Retaining screws 7 Example showing how multiple cables would be arranged along the front panel. 4 RJ21 right-angled c ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 48

    Connecting to the Network 3-18 Installation 4. V erify  that  a  link  exists  by  ch ecki ng  that  the  port  RX  (Receive )  LED  is  ON  (flashing  amber ,  blinking  green,  or  solid  green).  If  the  RX  LED  is  OFF  and  the  TX  (T ransmit)  L ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 49

    Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-19 2. Insert  the  MT ‐ RJ  cable  connector  into  the  MT ‐ RJ  front  panel  connector  until  it  clicks  into  place. Figure 3-1 1 Connecting a Fiber-Optic Segment to MT -RJ Front Panel Connector Note: Leave t ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 50

    Connecting to COM Port for Local Management 3-20 Installation 1. V erify  that  a  link  exists  by  ch ecki ng  that  the  port  RX  LED  is  ON  (flashing  amber ,  blinking  green,  or  solid  green).  If  the  RX  LED  is  OFF  and  the  TX  LED  is  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 51

    Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-21 Wi t h  a  UTP  straig ht ‐ through  cable  and  RJ45 ‐ to ‐ DB25  female  adapter ,  you  can  connect  products  equipped  with  an  RJ45  COM  port  to  a  VT  series ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 52

    Connecting to COM Port for Local Management 3-22 Installation Connecting to a VT Series T erminal To  connect  a  VT  Series  terminal  to  an  Enterasys Networks  DFE ‐ Gold module  COM  port  ( Figure 3 ‐ 13 ),  use  a  UTP  straight ‐ through  cable  with  RJ 45  connectors  an ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 53

    Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-23 When  these  parameters  are  se t,  the  Local  Management  password  screen  will  disp lay .  Refer  to  the  Enterasys  Matrix  DFE ‐ Gold  Series  Configuration  Guide  for ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 54

    Connecting to COM Port for Local Management 3-24 Installation 5. W ith  a  PC  connected  to  a  remote  modem,  you  can  configure  the  switch  remotely .  To  accomplish  this,  you  must  configure  you r  PC  VT  emulation  package  with  the  following  param ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 55

    Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-25 Adapter Wiring and Signal Assignment s COM Port Adapter Wiring and Sign al Diagram RJ45 DB9 Pin Conductor Pin Signal 1 Blue 2 Receive (RX) 4 Red 3 T ransmit (TX) 5 Green 5 Ground (GRD) 2 Orange 7 R equest to Send (RTS) 6 Y ellow 8 Clear to Se ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 56

    Completing the Installation 3-26 Installation Completing the Inst allation Completing  the  DFE  module  ins tallation  depends  on  if  the  module  is  being  installed  in: •a  new  DFE  module  sys tem  (refer  to  “Completing  the  Installation”  on  page 3 ‐ 26), ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 57

    Completing the Installation Matrix DFE-Gold Series Modules Hardware Installation Guide 3-27 First-T ime Log-In Using a Console Port Connection Start  the  Command  Line  Interface  (CLI)  from  the  module’ s  local  console  port  as  follows: 1. Connect  a  terminal  to  the  local  conso ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 58

    Completing the Installation 3-28 Installation Completing the Inst allation of a DFE-Gold Module in an Existing System In  an  established  DFE ‐ Gold module  system, •a  DFE ‐ Gold module  is  already  established  as  the  management  module, •t h e  passwords  have  already  been  set  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 59

    Completing the Installation Matrix DFE-Gold Series Modules Hardware Installation Guide 3-29 Logging in with an Administrati vely-Configured User Account If  the  device’ s  default  user  account  settings  have  been  changed,  proceed  as  follows: 1. At  the  login  prompt,  enter  your  ad ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 60

    Completing the Installation 3-30 Installation ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 61

    Matrix DFE-Gold Series Modules Hardware Installatio n Guide 4-1 4 T roubleshooting This  chapter  provides  information  concerning  the  following: • Using  LANVIEW  (page 4 ‐ 1) • T roubleshooting  Checklist  (page 4 ‐ 7) • Overview  of  DFE ‐ Gold  Modu le  Shutdown  Procedure  (page 4 ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 62

    Using LANVIEW 4-2 Troubleshooting Vi ewing Receive/T ran smit Activi ty on 4H4282-49, 4H4283-49, and 4H4203-72 On  the  4H4282 ‐ 49,  4H4283 ‐ 49,  and  4H4203 ‐ 72  you  can  view  the  re ceive  and  transmit  activity  on  the  RX  and  TX  LEDs.  How ever ,  only  one  g ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 63

    Using LANVIEW Matrix DFE-Gold Series Modules Hardware Installatio n Guide 4-3 Vi ewing Receive/T ransmit Activity on 4H4202-72 On  the  4H4202 ‐ 72,  you  can  view  the  receive  and  transmit  activity  on  the  RX  and  TX  LEDs.  Howev er ,  only  one  group  of  24  ports ? ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 64

    Using LANVIEW 4-4 Troubleshooting Viewing the Receive and T ran smit Activity on 4H4284-49 On  the  4H4284 ‐ 49  DFE ‐ Gold module,  you  can  view  the  receiv e  and  transmit  activity  on  the  RX  and  TX  LEDs.  Howev er ,  only  one  group  of  12  ports  may  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 65

    Using LANVIEW Matrix DFE-Gold Series Modules Hardware Installatio n Guide 4-5 T able 4-1 LANVIEW LEDs LED Color Stat e Recommended Act ion MGMT None Off . This module is NOT the Management Module. None. Green Solid . This module is the designated Management Module. None. Amber Flashing . This is a temporary indi cation that the module is saving dat ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 66

    Using LANVIEW 4-6 Troubleshooting RX (Receive) None No link . No activity . Port enabled or di sabled. None. Green Solid . Link present, port enabled, no traffic is being received by th e interface. None. Amber Flashing . Link present, port enabled, traffic is being received by th e interface. Rate of flashing indica tes the data transmission rate. ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 67

    Troubleshooting Checklist Matrix DFE-Gold Series Modules Hardware Installatio n Guide 4-7 T roubleshooting Checklist If  the  module  is  not  wor ki ng  properly ,  refer  to  Ta b l e 4 ‐ 1  for  a  checklist  of  problems,  possible  causes,  and  recommended  actions  to  resolve ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 68

    Troubleshooting Checklist 4-8 Troubleshooting Port(s) goes into standby for no apparent reason. Loop conditio n detected. V erify that S panning T ree is enabled. Refer to the Enterasys Matrix DFE-Gold Serie s Configuration Guide for the instructions to set the type of ST A. Review the network design an d delete unnecessary l oops. If the problem c ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 69

    Overview of DFE-Gold Module Shutdown Procedure Matrix DFE-Gold Series Modules Hardware Installatio n Guide 4-9 Overview of DFE-Gold Module Shut down Procedure The  DFE ‐ Gold module s  installed  in  a  Mat rix  N3  or  Matrix  N7  chassis  are  inter dependent  and  operate  under  a  single  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 70

    Overview of DFE-Gold Module Shutdown Procedure 4-10 Troubleshooting Recommended Shut down Procedure Using OFFLINE/RESET Switch Before  pulling  a  DFE ‐ Gold module  out  of  a  chas sis,  press  or  tap  on  its  OFFLINE /RESET  switch  for  less  than  1 second.  Its  CPU  LED  c ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 71

    Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-1 A Specifications This  appendix  provides  information  about  the  f ollowing: • DFE ‐ Gold  Module  Specifications  (page A ‐ 1) • COM  Po r t  Pinout  Assignments  (page A ‐ 3) • Regulatory  Compliance  (page A ‐ 4) ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 72

    DFE-Gold Module Specifications A-2 Specifications 4H4203-72 Ports 1 through 72 Seventy- two, 10BASE-T/100BASE-TX compliant ports through six RJ21 connectors. 4H4202-72 Ports 1 through 72 Seventy- two, 10BASE-T/100BASE-TX compliant ports through 72 RJ45 connectors. 4H4284-49 Ports 1 through 48 Forty-eigh t, 100BASE-FX multimode fi ber-optic complian ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 73

    COM Port Pinout Assignments Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-3 COM Port Pinout Assignment s The  COM  port  is  a  serial  communications  port  for  loc al  access  to  Local  Management.  Refer  to  Ta b l e A ‐ 2  for  the  COM  port  pin  a ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 74

    Regulatory Compliance A-4 Specifications Regulatory Compliance The  4H4282 ‐ 49,  4H4283 ‐ 49,  4H4203 ‐ 72,  4H4 202 ‐ 72,  4H4284 ‐ 49,  and  7G ‐ 6MGBIC  meet  the  safety  and  electromagnetic  compatibility  (EM C)  requirements  listed  in  Ta b l e A ‐ 3 : T able A-3 Complia ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 75

    Matrix DFE-Gold Series Modules Hardware Installation Guide B-1 B Mode Switch Bank Settings and Optional Installations This  appendix  covers  the  following  items: • Required  T ools  (page B ‐ 1) • Setting  the  Mode  Switches  (page B ‐ 2) • Memory  Locations  and  Replacement  Procedure s ? ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 76

    Setting the Mode Switches B-2 Mode Switch Bank Settings and Optional Installations Setting the Mode Switches Figure B ‐ 1  and  Figure B ‐ 2  show  the  location  of  the  mode  switches  and  the  switch  settings  for  normal  operation.  These  switches  are  set  at  the  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 77

    Setting the Mode Switches Matrix DFE-Gold Series Modules Hardware Installation Guide B-3 Figure B-1 Mode Switch Location on 4H4282-49 and 4H4283-49 1 Mode switch bank (located in same location on both the 4H4282-49 and 4H4 283-49) Figure B-2 Mode Switch Location on 4H4203-72 1 Mode switch bank 4H4282-49 F AST ENET DFE 1 2 3 4 5 6 ➀ ON 12 34 5 6 7 ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 78

    Setting the Mode Switches B-4 Mode Switch Bank Settings and Optional Installations Figure B-3 Mode Switch Location on 4H4202-72 1 Mode switch bank Figure B-4 Mode Switch Location on 4H4284-49 1 Mode switch bank ➀ 1 2345678 ON COM OFFLINE / RESET CPU MGMT GROUP GROUP SELECT GROUP 1 GROUP 2 GROUP 3 1X 6X 7X 12X 13X 18X 19X 24X 1 2 3 4H4202-72 F AST ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 79

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-5 Memory Locations and Replacement Procedures In  the  event  that  the  Dual  In ‐ line  Memory  Module  (DIMM)  or  DRAM  Single  In ‐ line  Memory  Module  (SIMM)  (FLASH  memory)  ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 80

    Memory Locations and Replacement Procedures B-6 Mode Switch Bank Settings and Optional Installations Figure B-6 DIMM and DRAM SIMM Locations (4H4203-72) 1 DRAM SIMM 2 DIMM 3 Main PC board Figure B-7 DIMM and DRAM SIMM Locations (4H4202-72) 1 DRAM SIMM 2 DIMM 3 Main PC board  À Á G R O U P 1 G R O U P 2 G R O U P 3 G R O U P 4 7 2X 7 2X 6 1X 6 1 ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 81

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-7 DIMM Replacement Procedure (4H4282-49 and 4H4283-49) To  remove  and  replace  the  DRAM  SIMM  on  the  4H4282 ‐ 49  or  4H4283 ‐ 49,  refer  to  Figure B ‐ 8  and  Figure B ‐ 9  resp ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 82

    Memory Locations and Replacement Procedures B-8 Mode Switch Bank Settings and Optional Installations 2. Refer  to  Figure B ‐ 9 .  Push  the  connector  arms  aw ay  from  the  mem ory  module  to  release  it  from  the  connector .  3. Remove  the  module  from  the  connector ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 83

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-9 Removing the DRAM SIMM from 4H4203-72 To  remove  the  existing  DRAM  SIMM,  proceed  as  follows: 1. Locate  the  DRAM  SIMM  connector  on  the  main  PC  board.  Refer  back  to ? ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 84

    Memory Locations and Replacement Procedures B-10 Mode Switch Bank Settings and Optional Installations 3. Pull  the  DRAM  SIMM  straight  up  and  remove  it  from  the  connector . Inst alling the DRA M SIMM on 4H4203-72 To  install  the  DRAM  SIM M,  refer  to  Figure B ‐ 12  and  pro ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 85

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B -11 DRAM SIMM Replacement (4H4202-72) Figure B-12 Installing the DRAM SIM M on 4H4203-72 1 Connector arms 3 Connector fingers 2 DRAM SIMM 4 Alignment notches (2) À Ã Á Ã À Â Note: Because of the complexity of correctly replacing the large ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 86

    Memory Locations and Replacement Procedures B-12 Mode Switch Bank Settings and Optional Installations DIMM Replacement Proc edure (All DFE Modules) In  the  event  that  the  DIMM  needs  to  be  replaced,  the  following  sec tions  explain  how  to  remove  and  install  the  DIMM.  I ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 87

    Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B -13 Inst alling the DIMM To  install  a  DIMM,  refer  to  Figure B ‐ 14  and  proceed  as  follows: 1. Insert  the  DIMM  down  between  the  connector  fingers . 2. Pivot  the  DIMM ? ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 88

    Memory Locations and Replacement Procedures B-14 Mode Switch Bank Settings and Optional Installations ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 89

    Index-1 Index Numerics 100BASE-FX connections 3-18 requirements 2-2 100BASE-TX connections 3-1 1 requirements 2-2 10BASE-T connections 3-1 1 , 3-15 requirements 2-1 4H4202-72 introduction to 1-3 4H4203-72 introduction to 1-3 4H4282-49 introduction to 1-2 4H4283-49 introduction to 1-2 4H4284-49 introduction to 1-3 C Cable connections 4H4282-49 or 4 ...

  • Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - page 90

    Index-2 Matrix N3 chassis module installation into 3-9 Matrix N5 chassis module installation into 3-9 Memory replacement of DRAM B-12 Memory locations DIMM and SIMM B-5 Mode Switch setting of B-2 Module features 1-2 , 1-3 N NEM 3-3 Network connecting to 3-10 Network expansion module 3-3 Network Requirements list of 2-1 O OFFLINE/RESET button 4-10 O ...

Fabricant Enterasys Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilEnterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Enterasys
- manuels d’utilisations Gold Distributed Forwarding Engine 4H4202-72
- fiches produit Enterasys
- dépliants
- ou étiquettes-énergie Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72.

Le manuel d’utilisation complet Enterasys, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEnterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 - qui devraient nous aider dans les premières étapes lors de l'utilisation Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Enterasys Enterasys Gold Distributed Forwarding Engine 4H4202-72 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)