    MS9530 Series Voyager® RF Single Line Hand-Held RF Bar Code Scanner Installation and User’s Guide PRELIMINARY MS9530 Voyager RF Printed: September 2002 Version: 1.1 Status: Approved 1 ...

  • Metrologic MS9530 Series - page 2

    Table of Contents Voyager RF Scanne r – Over view ............................................................ 3 Base Stat ion.............................................................................................. 4 Unpacking List.......................................................................................... 5 Connecting the Bas ...

  • Metrologic MS9530 Series - page 3

    Product Overview The MS9530 Series Voyager RF is a wireless single line hand-held scanner with one bi-directional RF channel radio which provides about 20-30 meters portability. It has got a battery pack which can be removed from the unit to be charged through a Wall-Power supply in about 110 min. No charging stand is required. Once charged the uni ...

  • Metrologic MS9530 Series - page 4

    BASE STATION The Base Station is a interface decoder to which the Voyager is connected via a virtual RS232 port. Its func tion is to receive RF data from Voyager RF and transmit it to the Host. Therefore, all the standar d features that can be used when connecting a RS232 device to a Base Station, as explained in the Base Station Configuration Guid ...

  • Metrologic MS9530 Series - page 5

    UNPACKING LIST The kit is packed accordi ng to its functionality: Transmitter: • Voyager RF: Reader + Battery Pack • Wall-Power Supply for Battery Pack charging • Voyager RF Configuration Manual • Voyager RF installation and User guide Base Station: • Base Station • Base Station Manual • For Wedge interface: 1. Cable Y-XX 2. Power Sup ...

  • Metrologic MS9530 Series - page 6

    CONNECTING THE BASE STATION TO THE HOST WEDGE INTERFACE 1. Turn off the Host system 2. Connect the cable Y-XX between the keyboard and Host 3. When Power supply required (it is recommended all the times for better RF transmissions), check that the voltage matches the AC outlet and then connect 4. Power up the Host system RS232 INTERFACE 1. Turn off ...

  • Metrologic MS9530 Series - page 7

    LINKING THE VOYAGER RF TO THE BASE STATION This section explains how to link the Vo yager RF to the Base Station. It is supposed that the software is already loaded into the unit and that the Base Station is configured with its own serial number. • Power ON the Base Station • Insert Battery Pack and press CodeGate button to power ON the unit. ? ...

  • Metrologic MS9530 Series - page 8

    • Read Fix Serial RF Number barcode to load Base Station's serial number into the Voyager. • Read Base Station Serial Number barcode. (located on the Base Station). • Read Enter/Exit Configuration Mode barcode. • After reading this barcode the Voyager will try to link the Base Station. Now a linki ng should be performed. At this moment ...

  • Metrologic MS9530 Series - page 9

    FIXING VOYAGER RF ID NUMBERS This section explains how to fix an Identifier number to each Voyager RF. Basically, each Base Station can work with up to 5 VoyagerRF’s at the same time. To enable this facility, an Identif ier Number (ID) mu st be configured to each Voyager RF. By reading RF De faults, ID=1 is configured. There cannot be more than o ...

  • Metrologic MS9530 Series - page 10

    The system is ready to work. Please note again, that each time a Voyager RF is activated, it indicates its ID number just before linking with Base Station with steady RED and GREEN LED’s whilst the YELLOW LED flashes an appropriate number of times in relation to its ID number. Ie; one YELLOW led flash means ID=1 and 5 YELLOW LED flashes would ind ...

  • Metrologic MS9530 Series - page 11

    BASE STATION TESTING BARCODE The Base Station will accept all data fr om Voyager RF where the Base Serial Number is “0000000000”. Use this Test Barcode as Base Serial Number when programming the Voyager RF Serial Number to fix t he Voyager RF in test Mode. This Barcode is for testing purpose s and should NEVER can be considered as functional Ba ...

  • Metrologic MS9530 Series - page 12

    BATTERY PACK In order to charge the Batte ry Pack, there is no need to use a cradle. It can be re-charged when disconnected from the sca nner with the Voyager RF 5V, 1.5A Wall Power Supply. The Battery Pack can’t be recharged while inserted into the Voyager. Therefore it is recommended that two battery packs are used. One can be in use with the s ...

  • Metrologic MS9530 Series - page 13

    Standby mode will discharge the battery pac k in around 5 days. The number of readings will naturally decreas e as the standby time incr eases. To avoid having low battery messages appearing, it is recommended that the battery pack is disconnected from the sc anner when not in use over an extended period of time. MS9530 Voyager RF Printed: Septembe ...

  • Metrologic MS9530 Series - page 14

    VISUAL INDICATORS The scanner has RED and GREEN LED’s. When the scanner is on, these visual indicators show the st ate of the scanner functionality. Start Up Sequence From Stand-by, once the user presses Co deGate button, the scanner goes into start-up mode. Whilst in this mode, the YELLOW LED is displayed. 1. The scanner starts checking its OS ( ...

  • Metrologic MS9530 Series - page 15

    Low Battery Message When the battery starts to loose its c harge, the scanner detects it and makes a Razzberry sound every time a new r eading is performed. The YELLOW, RED and GREEN LED’s will also flash alternatively. However, the Voyager RF will continue to operate. The operator should, at this point, re move the battery pack and recharge it. ...

  • Metrologic MS9530 Series - page 16

    PROGRAMING MODES Voyager RF can be programmed vi a Barcodes. Use Metrologic’s MetroSelect Single Line Configuration Guide to configure the unit. This configuration guide is common to all Voyagers. When using Voyager RF, this one should be used and the following sections of the Single Line Configuration Guide should be avoided: RS-232, Keyboard, O ...

  • Metrologic MS9530 Series - page 17

    MetroSet It is possible to download/upload se ttings from MetroSet 2 (PC based software) to each Voyager RF by radio. In order to do that, read t he MetroSet RF barcode with the Voyager RF that you want to work with and follow MetroSet RF instructions. Always read this barcode before runni ng the MetroSet RF upload/download commands. Keep the Voyag ...

  • Metrologic MS9530 Series - page 18

    SOFTWARE VERSION It is possible to find out the software of Voyager RF as well as the Base Station to which the unit is linked with. Scanning the following barcode, the Base Station will transmit the actual software revision with the following format: MI9530 BASE STATION: #50200, MA RCH 2002.| MS9530: BODY/OS #14655/50100 MS9530 Voyager RF Printed: ...

  • Metrologic MS9530 Series - page 19

    EML EML Handshake is a defined data formatting handshake that allows the Voyager RF to send and receive data from the Host System through the Base Station. To be able to use this f eature, the Ba se Station: • Must be connected via RS232 to the Host System using the M-01 cable • Must have EML feature activated (see Base Station’s manual to kn ...

  • Metrologic MS9530 Series - page 20

    MS9530 Voyager RF Printed: September 2002 Version: 1.1 Status: Approved 20 SPECIFICATIONS RF LINK SPECIFICATIONS Frequencies: 434 MHz Bandwidth: 2 x 75 kHz Modulation: FM RF Protocol: Two way data transmission, One channel. 39062.5 Baud speed. Output Power Voyager RF: <10 mw Output Power Base Station: 6 mw Operating Range: Up to 30 Mts. (Open Ai ...

Fabricant Metrologic Catégorie Scanner

Les documents que nous recevons du fabricant de l'appareilMetrologic MS9530 Series peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Metrologic
- manuels d’utilisations MS9530 Series
- fiches produit Metrologic
- dépliants
- ou étiquettes-énergie Metrologic MS9530 Series
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Metrologic MS9530 Series.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Metrologic MS9530 Series, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Metrologic MS9530 Series. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Metrologic MS9530 Series.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Metrologic MS9530 Series, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Metrologic MS9530 Series par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Metrologic MS9530 Series.

Le manuel d’utilisation complet Metrologic, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Metrologic MS9530 Series - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Metrologic MS9530 Series, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMetrologic MS9530 Series qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Metrologic MS9530 Series - qui devraient nous aider dans les premières étapes lors de l'utilisation Metrologic MS9530 Series
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Metrologic MS9530 Series
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Metrologic MS9530 Series dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Metrologic MS9530 Series?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Metrologic MS9530 Series, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Metrologic MS9530 Series il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)