  • TFA Xeno - page 1

    20 WE A THER STAT ION Instruction Manual Cat. No. 35.1 111.IT Thank you for choosi ng this wirel ess weather stati on from TFA. BEFORE Y OU USE IT Please be sure to read the i nstruction manual carefully. This information wi ll help you to famili arise yoursel f with your new device, l earn all of i ts functions and parts, fi nd out important detai ...

  • TFA Xeno - page 2

    21 FOR YOUR S AFETY: • The product is e xclusively intended for t he field o f applicati on described above. The product should only be used as descri bed within these i nstructions. • Unauthorised repai rs, modificati ons or changes to the product are pro hibited. • The product is not to be used for medical purpose or for publi c information ...

  • TFA Xeno - page 3

    22 Stand LCD Display Function keys ELEMENTS The Weather S tation Thermo-H ygro Transmit ter • Remote transmissi on of outdoor temperature and humidity to weather station by 868MH z • Alternately di splay the outdoor temperature and humidity readi ngs on LCD • W all mounting case • Mounting at a shel tered place. Avoi d direct rai n and suns ...

  • TFA Xeno - page 4

    23 1. Remove the battery cover b y pushing the battery cover upwards with your thumb. 2. Insert the batteries, observi ng the correct polari ty (see battery compartment marki ng). 3. Replace the battery cover o n the unit. TO INSTAL L AND REP LACE BAT TERIES IN THE WEATHER S TATION The weather statio n uses 2 x AA, IEC L R6, 1.5V batteri es. To ins ...

  • TFA Xeno - page 5

    24 SETTING UP 1. First, insert the batteri es in the transmi tter (see “T o install and replace batterie s in the ther mo-hygro transmitter ” above). 2. Within 2 minutes of poweri ng up the tran smitter , insert the batteries i n the weather statio n (see “ To install and replace batterie s in the w eather station ” above). O nce the batter ...

  • TFA Xeno - page 6

    25 DCF RADIO C ONTRO LLED TIME The time base for t he radio controll ed time is a C esium Atomic Cl ock operated by the Physikali sch Technisc he Bundesanstalt Bra unschweig which has a time dev iation of less than one seco nd in one milli on years. The time i s coded and transmi tted from Mainfli ngen near Fra nkfurt via frequency signal DCF-77 (7 ...

  • TFA Xeno - page 7

    26 + key MIN/MAX key SET key FUNCTION KE YS: Weather Station: The weather statio n has 3 easy to use f unction keys: SET key • Press and hold t he key to enter manual setting modes: time zone, ma nual time setti ng, calendar, time recepti on ON/OFF + key • Increase, change, toggl e all values in manual set mode MIN/MAX key • Press shortly to ...

  • TFA Xeno - page 8

    27 LCD SCREEN The LCD screen is spl it into 5 sections di splayi ng the information for time/cal endar, weather f orecast, moo n phase, indoor data, a nd outdoor data. * W hen the signal is successfull y received by the weat her station, the outdoor tra nsmission icon wi ll be swi tched on. (If not successful, t he icon will not be shown on LCD). T ...

  • TFA Xeno - page 9

    28 TIME ZONE S ETTING: The time zone defa ult of the weather stati on is “0”. To set a different time zo ne: 1. The current time zone value starts flas hing. 2. Use the + key to set t he time zone. T he range runs from 0 to -12 and t hen runs from +12 back to 0 in consecutive 1-ho ur intervals. 3. Confirm with the SE T key and enter the Manual ...

  • TFA Xeno - page 10

    29 CALENDAR SETTING: The date default of t he weather statio n is 1. 1. 2011. O nce the radio-controll ed time signals are rec eived, the date i s automaticall y updated. However, if the s ignals are not received, the date ca n also be set manual ly. 1. The year starts flas hing. 2. Use the + key to set t he year (betwee n year 2011- 2039). 3. Pres ...

  • TFA Xeno - page 11

    30 Note: If the Time Reception fu nction is turned OFF manually, the clock will not atte mpt any reception of the DCF time as long as the Time Reception OF F function is activated. The time reception icon “ “ w ill not be displayed on the LCD. TO EXIT THE M ANUA L SETTING M ODE To exit the manual setting mode anytim e during t he manual setti n ...

  • TFA Xeno - page 12

    31 any better (with sunny i con) or worse (wi th rai ny icon) since the icons are al ready at their extre mes. The icons displ ayed forecasts the weather in terms of getting better or worse a nd not necessari ly sunny or rai ny as each icon indicates. For example, i f the current weat her is cloudy and the rai ny icon is displ ayed, it does not mea ...

  • TFA Xeno - page 13

    32 Indoor relative humidity in RH% Indoor temperature in ºC indicator i s pointing downwards together w ith cloud a nd sun icons, then the l ast noticeable change in the weat her was when it was s unny (the sun icon onl y). Therefore, t he next change in the weat her will be cloud with rain i cons since the indicator i s pointing downwards . Note: ...

  • TFA Xeno - page 14

    33 distance may be decreased . Please bear t his in mi nd when positi oning the transmitters. Al so the batteri es may be reduced in power for t he thermo-hygr o transmi tter. CHECKING FOR 868MHz R ECEP TION If the outdoor temperat ure and humidi ty data are not bei ng received wi thin three minutes after setti ng up (or o utdoor display al ways sh ...

  • TFA Xeno - page 15

    34 To wall mount: 1. Fix a screw (not suppl ied) into the desired wall , leaving the head extended out by abo ut 5mm. 2. Place the weather stati on onto the screw, using the ha nging hole on the backside. Gently p ull the weather station down to lock t he screw into place. Free standing: With the detachabl e stand, the weather station can be placed ...

  • TFA Xeno - page 16

    35 CARE AND M AINTEN ANCE • Clean the instrume nt and the transmitter with a soft damp cloth. Do not use solvents or scou ring agents. Protect from moist ure. • Remove the batteri es if you do not use t he product for a lengthy period. TROUBLESHO OTING Problems Solution No indicati on on the weather station • Ensure batteries pol arity are co ...

  • TFA Xeno - page 17

    36 appropriate coll ection sites accordi ng to national or local regulations in order to protec t the enviro nment. The symbols for t he heavy metals contained are: Cd=cadmium, Hg=merc ury , Pb=lead This instrument is l abelled in accordance with the EU Waste Electrical and Electronic Equipment Directi ve (WEEE). Please do not dispose of t his prod ...

  • TFA Xeno - page 18

    37 TFA Dostmann GmbH & C o. KG, Z um Ottersberg 12, D - 97877 W ertheim No part of this ma nual may be reproduc ed without wri tten consent of TFA Dostma nn. The technic al data are correct at the time of goi ng to print and may cha nge without pri or notice. DECLARATIO N OF CON FORMIT Y Herewith we declare, t hat this wirel ess transmissi on d ...

Fabricant TFA Catégorie Weather station

Les documents que nous recevons du fabricant de l'appareilTFA Xeno peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques TFA
- manuels d’utilisations Xeno
- fiches produit TFA
- dépliants
- ou étiquettes-énergie TFA Xeno
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation TFA Xeno.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation TFA Xeno, manuels d’entretien, brefs manuels ou manuels de l’utilisateur TFA Xeno. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit TFA Xeno.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil TFA Xeno, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser TFA Xeno par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs TFA Xeno.

Le manuel d’utilisation complet TFA, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel TFA Xeno - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières TFA Xeno, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTFA Xeno qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil TFA Xeno - qui devraient nous aider dans les premières étapes lors de l'utilisation TFA Xeno
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de TFA Xeno
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service TFA Xeno dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de TFA Xeno?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec TFA Xeno, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec TFA Xeno il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)