    Simply connecting the world Patch Release Note Patch 86241-06 For Rapier Switches Intr oduction This patch rel ea se note li sts the issues ad dressed and enhancements made in patch 86241-06 for Software Release 2.4. 1 on existing models of Rapier L3 managed switches. Patch file details are li sted in T able 1. This release note should be r ead in ...

  • Allied Telesis 86241-06 - page 2

    2 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E Featur es in 86241-06 Patch 86241-06 includes all issues reso lved and e nhancem ents released in previous patch es for Software Release 2.4.1, an d the following enhancements: Wh en m o re t ha n tw o f ire w a ll p ol ic i es were configur ed, an unexpecte d switc ...

  • Allied Telesis 86241-06 - page 3

    Patch 86241-06 For Rapier Switches 3 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E During an SSH session between the sw itch and the Secur e CR T client, the client did not receive a r eply to it s MAX-packet-size CMSG. The switch does not support this message, but will now send a negative r esponse to satisfy the secure CR T clie ...

  • Allied Telesis 86241-06 - page 4

    4 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E DHCP was assigni ng incorre ct IP addr esses to clients when they moved from a r elayed to a non-r elayed range. Gateway checks have been ad ded to remove this issue. Deriving the originating VLAN f rom incoming packets could, in some circumstances, cause a software ...

  • Allied Telesis 86241-06 - page 5

    Patch 86241-06 For Rapier Switches 5 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E After sending a DHCP NAK in response to a client’s DHCP REQUEST with a bad lease ti me, the switch would fail to ag e out its corr esponding DHCP OFFER entry . This issue has been r esolved. The switch would disasse rt the AIS, IDLE, LOF and LOS a ...

  • Allied Telesis 86241-06 - page 6

    6 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E Featur es in 86241-05 Patch file details are listed in T able 2: Patch 86241-05 includes all issues reso lved and e nhancem ents released in previous patch es for Software Release 2.4.1, an d the following enhancements: Support has been added for SNMPv2c. SNMP respo ...

  • Allied Telesis 86241-06 - page 7

    Patch 86241-06 For Rapier Switches 7 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E Debugging commands are now available for the RADIUS and T ACACS control pr otocols. Raw packets, deco ded packets, and errors can now be displayed. Access control packet debugging allows the contents of the packets to be viewed. The debugging comman ...

  • Allied Telesis 86241-06 - page 8

    8 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E PIM was disabled permanentl y if the RESET IP command, or the DISABLE IP command followed by the ENABLE IP commands wer e executed. PIM is now automatically restarted if these commands ar e used. Previousl y the SET FIREW ALL POLICY RULE command permi t ted the use ...

  • Allied Telesis 86241-06 - page 9

    Patch 86241-06 For Rapier Switches 9 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E The DELETE IPV6 6T04 command sometimes caused an err or . This issue has been re sol v ed. The DECREMENT parameter of the ADD IPV6 INTERF ACE command was not recognised in the command line. This issue has been resolve d. The SET QOS TRAFFICCLASS com ...

  • Allied Telesis 86241-06 - page 10

    10 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E PPP interface speed. This issue has been r esolved so that the LNS side of the PPP interface shows the corr ect speed. Th e s ou rc e m as k i s n ow al wa ys 0x ffffffff in t he DV MR P f or wa rdi ng ta bl e. The temporary r oute in the DVMRP route table was not ...

  • Allied Telesis 86241-06 - page 11

    Patch 86241-06 For Rapier Switches 11 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E Some change actions, and the resending of pr u ne messages were not operating correctly . This issue has been resolved. The ADD FIREW ALL POLICY and SET FIREW ALL POLICY commands did not generate a valid port list whe n the optional POR T parameter ...

  • Allied Telesis 86241-06 - page 12

    12 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E After an ASYN port test, the port is now r eset to its pr e-test state if the test was started by a user connected to the same ASYN port. The following issues have been resolved: • When equal paths exist to a source, a PIM DM downstr e am switch/ router could not ...

  • Allied Telesis 86241-06 - page 13

    Patch 86241-06 For Rapier Switches 13 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E If multiple IPv6 interfaces shar ed the same link-local addr ess, pings to the link-local addr ess some times failed. This i ssu e has been reso lved. The source net mask has been r emoved from DVMRP prune , graft and graft-ack messages. Featur es ...

  • Allied Telesis 86241-06 - page 14

    14 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E The virtual MAC addr ess was used as the source MAC for all packets forwarded on an interface associated with a V irtual Router (VR). This was confusing when multiple VRs wer e defined over the same interface because only one virtual MAC address was ever used. The ...

  • Allied Telesis 86241-06 - page 15

    Patch 86241-06 For Rapier Switches 15 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E IPSec no longer logs packets that match an ACTION=ALLOW policy . The overhead of this logging was affecting non- IPSec traffic. The LOCALRSAKEY parameter in the CREA TE ISAKMP POLICY and SET ISAKMP POLICY commands was not acce pting the value zero. ...

  • Allied Telesis 86241-06 - page 16

    16 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E The SHOW IPV6 INTERF ACE command now shows the addr ess lifetime aging status that is determined by the DECREMENT pa rameter in the ADD IPV6 INTERF ACE command. The default valid and pr eferred addr ess lifetimes have been changed to 30 days and 7 days r espectivel ...

  • Allied Telesis 86241-06 - page 17

    Patch 86241-06 For Rapier Switches 17 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E The SHOW CLASSIFIE R command was not d isplaying Layer 3 in formation if the classifier had been cr eated with the parameters ETHFORMA T=SN AP and PROTOCOL={IP|0000000800}. This issue has been resolved. When acting as a PPPoE Access Concen trator ( ...

  • Allied Telesis 86241-06 - page 18

    18 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E When an IP Multihomed interface was used as an OSP F interface, neighbour r elationships wer e only established i f the IP interface for OS PF was added first in the configuration. Now , OSPF establis hes neig hbour relationships r egardless of the IP Multihomed in ...

  • Allied Telesis 86241-06 - page 19

    Patch 86241-06 For Rapier Switches 19 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E The following issues have been resolved: • It was possible to assign the same network on dif ferent IPV6 interfaces • The loopback address was being added to other interfaces • The tunnel configuration was not showing corr ectly in IPV6 confi ...

  • Allied Telesis 86241-06 - page 20

    20 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E An ISDN call was acti vated by IPv6 Router Advertisements over IPv6 tunnel interfaces. This issue has been r esolved. Packets with a RIP source addr ess and next hop addr ess that are not on the same subnet as the interface will now be processed. If the r eceived n ...

  • Allied Telesis 86241-06 - page 21

    Patch 86241-06 For Rapier Switches 21 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E Featur es in 86241-01 Patch file details are listed in T able 6: Patch 86241-01 includes the following enhancements: A new command allow s the Layer 3 aging timer to be changed: SET SWITCH L3AGEINGTIMER=<seconds> where seconds can be 30 - 432 ...

  • Allied Telesis 86241-06 - page 22

    22 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E but is now checked by ICMP handlers fo r attacks and eligibility . If the ICMP traffic matches a NA T rule, NA T will occur on inbound and outbound traffic. HTTP 1.0 r equests sometimes caused the fir ewall HTTP proxy to close prematur ely . Cached TCP sessions wer ...

  • Allied Telesis 86241-06 - page 23

    Patch 86241-06 For Rapier Switches 23 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E into 8 blocks of 8 5 bits with 84 bits available for payload, and one bit for framing overhead. The frame structure is shown in Figur e 1 on page 23. Figure 1: DS3 Framing Structur e. The switch with the DS3 interface is called the near end . The e ...

  • Allied Telesis 86241-06 - page 24

    24 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E The three C-bits in M-s ubf rame 4 ar e designated as FEBE bits. The FEBE bits are r eturned to the far end to indicate the occurrence of a framing err or or CP- bit parity err or . If none occur , the FEBE bits are set to all ones. One or all of the FEBE bits are ...

  • Allied Telesis 86241-06 - page 25

    Patch 86241-06 For Rapier Switches 25 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E Diagnostic loopback is shown in Figur e 3 on page 25. In this loopback mode the transmit signal is connected straight to the receive signal. Figure 3: Diagnostic Loopback. In C-bit parity mode it is also possible for the switch to request a loopbac ...

  • Allied Telesis 86241-06 - page 26

    26 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E maintenance link allows a nu mber of identification messages to be inserted in to the path over head of the DS3 signal. These messages ar e in the form of text characters and allow the users a t either end of the DS3 path to ensure that the correct DS3 signal has r ...

  • Allied Telesis 86241-06 - page 27

    Patch 86241-06 For Rapier Switches 27 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E The P ARAM24 parameter specifies the 24-hour counter thr eshold for all performance monitoring parameters (P ES, PSES, SEF , UAS, LES, CES, CSES) between 1 and 65535 seconds inclusive. If a trigger has been cr eated, it will assert if the 24-hour c ...

  • Allied Telesis 86241-06 - page 28

    28 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E ■ ENABLE DS3 TEST ■ RESET DS3 ■ RESET DS3 COUNTERS ■ SET DS3 ■ SHOW DS3 CMTCE ■ SHOW DS3 CONFIGURA TION ■ SHOW DS3 COUNTERS ■ SHOW DS3 DEBUG ■ SHOW DS3 ST A TE ■ SHOW DS3 TEST Once the interface is set up and configur ed, it can be used in conju ...

  • Allied Telesis 86241-06 - page 29

    Patch 86241-06 For Rapier Switches 29 Patch 86241-05 for Software R elease 2.4.1 C613-10340 -00 REV E Dynamic Port Security Dynamic Port Security allows for dynamic MAC addr ess learning on a switch port. If a MAC addr ess is unused for a peri od of time, it will be aged from the database of currently acce pted MAC address es. This allows the learn ...

  • Allied Telesis 86241-06 - page 30

    30 Patch Release Note Patch 86241-05 for Software R elease 2.4.1 C613-10340-00 REV E Figure 1-7: Example output from the SHOW SWITCH PORT command showing the RELEARN parameter . A vailability Patches can be downloaded fr om the So ftware Updates ar ea of the Allied T elesyn web site at www .alliedtelesyn.co.nz/su pport/updates/patches.html . A lice ...

Fabricant Allied Telesis Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilAllied Telesis 86241-06 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Allied Telesis
- manuels d’utilisations 86241-06
- fiches produit Allied Telesis
- dépliants
- ou étiquettes-énergie Allied Telesis 86241-06
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Allied Telesis 86241-06.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Allied Telesis 86241-06, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Allied Telesis 86241-06. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Allied Telesis 86241-06.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Allied Telesis 86241-06, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Allied Telesis 86241-06 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Allied Telesis 86241-06.

Le manuel d’utilisation complet Allied Telesis, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Allied Telesis 86241-06 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Allied Telesis 86241-06, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAllied Telesis 86241-06 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Allied Telesis 86241-06 - qui devraient nous aider dans les premières étapes lors de l'utilisation Allied Telesis 86241-06
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Allied Telesis 86241-06
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Allied Telesis 86241-06 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Allied Telesis 86241-06?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Allied Telesis 86241-06, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Allied Telesis 86241-06 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)