    ACT 250 TURBOMOLECULAR PUMP CONTROLLER FOR A TP 150 AND A TP 400 A TP Series User’ s Manual addendum ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 2

    Contents ACT 250 addendum Alcatel V acuum T echnology France - ACT 250 addendum 1 January 2001 Commissioning Presentation ■ The ACT 250 controller . . . . . . . . . . . . . . ■ p. 3 ■ Main characteristics . . . . . . . . . . . . . . . . ■ p. 3 ■ Accessories . . . . . . . . . . . . . . . . . . . . . . ■ p. 4 ■ ■ Pump supply cable ■ ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 3

    Contents ACT 250 addendum Alcatel V acuum T echnology France - ACT 250 addendum 2 January 2001 Use Commissioning (continued) ■ Controlling the pump from the ACT 250 controller . . . . . . . . . . . . . . . . . ■ p. 24 ■ Controller functions . . . . . . . . . . . . . . . . . ■ p. 26 ■ ■ Precautions ■ ■ Operation in local mode ■ ■ ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 4

    Presentation Alcatel V acuum T echnology France - ACT 250 addendum 3 January 2001 The ACT 250 controller Dear Customer , Y ou have just bought an ACT 250 controller . In order to ensure the best possible performance of the equipment and your complete satisfaction in using it, we advise you to read this addendum carefully before attempting to servic ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 5

    Presentation Alcatel V acuum T echnology France - ACT 250 addendum 4 January 2001 Accessories Pump power supply cable The controller is connected to the pump using a corresponding power supply cable, ordered separately . Cable length (m) Par t No. 1 105086 1.5 A458885 3.5 101812 5 101810 10 101811 15 105303 20 A458478 Kit Par t No. USA 108935 Europ ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 6

    Presentation Alcatel V acuum T echnology France - ACT 250 addendum 5 January 2001 ACT 250 “ box ” controller control modes Local control mode A C T 2 5 0 A C T 2 5 0 POWER FAUL T SPEED STAR T STOP 1 2 Pump start-up switch Pump stop switch Pump status indicators Controller power and fault indicators Remote control The remote control Established ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 7

    Presentation Alcatel V acuum T echnology France - ACT 250 addendum 6 January 2001 ACT 250 “ OEM ” controller control modes Pump start-up switch Pump stop switch Pump status indicators Controller power and fault indicators Local control mode 2 1 Remote control The remote control Established by the REMOTE connector which: - provides remote contro ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 8

    Presentation Alcatel V acuum T echnology France - ACT 250 addendum 7 January 2001 ACT 250 controller technical characteristics Characteristic Unit ACT 250 “ box ” ACT 250 “ OEM ” W eight kg 1.8 1.3 Dimensions H xWxD m m 128.4 × 106.3 × 220 95 × 100 × 212 3U × 1/4 Rack Nominal voltage V 85 - 265 Frequency Hz 50/60 Maximum power W 300 Ma ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 9

    Presentation Alcatel V acuum T echnology France - ACT 250 addendum 8 January 2001 ACT 250 controller technical characteristics RS232 / 48 5 PU MP RE M OT E PO W ER SUPPL Y 212 4t r Ø 3 ,2 P O W ER SUPPLY F A U LT < S PEED A T S PEED S TART S T O P 153 ,1 8 mini . L1 L2 T 4 ,75 9 0 , 15 18 , 6 7 95 m a xi . 100 ACT 250 “ OEM ” dimensions (in ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 10

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 9 January 2001 Safety instr uctions Before switching on the controller , the user should study the manual and follow the safety instructions listed in the compliance cer ti fi cate booklet supplied with the pump. See sheet B10 in the A TP pump User Manual. ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 11

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 10 January 2001 ACT 250 controller electrical connections Connect the RS232/485 serial link cable to the connector (cable and PC supplied by customer) ■ If the controller is remote controlled, make the various connections on the REMOTE connector (see page 13 for wiring details). ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 12

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 11 January 2001 ACT 250 remote connector characteristics When units containing the control circuits are equipped with dr y contact outputs, it is the customer's responsibility to use the outputs in compliance with safety regulations. V oltage control mode Principle of voltage- ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 13

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 12 January 2001 ACT 250 remote connector characteristics Signalling on output contacts These are dr y contacts (48 V AC - 1 A) which replicate pump status information. When the output contact is closed: 1 6 2 7 3 8 4 9 1 - 6 The pump has reached the selected speed 2 - 7 The pump is ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 14

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 13 January 2001 ACT 250 remote connector wiring Use in local mode ■ Standard connector plug (factor y wired) Use in remote control mode ■ Without galvanic isolation (not recommended) Wiring seen from solder side. ■ With galvanic isolation (recommended) Wiring seen from solder ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 15

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 14 January 2001 RS 232 / 485 serial link Wiring the RS 232 or RS 485 serial link See sheet B 110 in the A TP Series Pump User Manual. Con fi guring the RS 232 or RS 485 serial link The link is con fi gured using switches on the rear panel of the controller . 01 Switch description ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 16

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 15 January 2001 Detailed description of RS commands Syntax conventions applicable to all commands Status values Error messages ADR Syntax Result adr = address, from 000 to 255 <CR> Carriage Return (ascii 13) <LF> Line Feed (ascii 10); shown in brackets as it is not comp ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 17

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 16 January 2001 Detailed description of RS commands CKS Syntax Result CYC Syntax Result Enables or disables checksums on reply strings #adr CKS ON<CR>[<LF>] Enables the ASCII checksum character at the end of a reply string or #adr CKS OFF<CR>[<LF>] Disables ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 18

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 17 January 2001 Detailed description of RS commands DLI Syntax Result See also: DLR DLR Syntax Result See also: DLI, LNG, SEP , SHT Enables DataLogger operation (RS232 only) #adr DLR <CR>[<LF>] #adr ,sssss,nnnnn,iiii,ttttt,uuuu.o,www ,ppp,vvv Returns current values : ss ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 19

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 18 January 2001 Detailed description of RS commands HDR Syntax Result IDN Syntax Result Identi fi es the device which is communicating, and its software version #adr IDN <CR>[<LF>] #adr , VS.... - Vx.zz ’ or #adr , VS.... - Vx.zz for “ Alcatel pump type ” Returns ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 20

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 19 January 2001 Detailed description of RS commands LEV Syntax Result LNG Syntax Result See also: SHT Returns the state of the parameters de fi ned by SET #adr LEV <CR>[<LF>] #adr ,nnnnn,sssss,aaaa,hhhhh or #adr ,nnnnn rpm,sssss rpm,aaaa mA,hhhhh hours Returns the curr ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 21

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 20 January 2001 Detailed description of RS commands OPT Syntax Result See also: SEL Used to select possible user choices #adr OPT2 n<CR>[<LF>] choice of temperature unit: n = 0 : degrees Centigrade n = 1 : degrees Fahrenheit #adr ,ok Comment: The choice of the temperatu ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 22

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 21 January 2001 Detailed description of RS commands SBY Syntax Result See also: NSP , RPM Switches the speed set point to the stand-by value #adr SBY <CR>[<LF>] #adr ,ok Resets the stand-by speed to its last stored value, and allows it to be modi fi ed if an “ RPM ? ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 23

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 22 January 2001 Detailed description of RS commands SET Syntax Result See also: LEV SHT Syntax Result See also: LNG SPD Syntax Result See also: LNG , SHT De fi nes the internal operating parameters #adr SET 1 hhhhh<CR>[<LF>] : maintenance time limit 000<hhhhh<655 ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 24

    Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 23 January 2001 Detailed description of RS commands ST A Syntax Result TMP Syntax Result Returns the status of the internal dynamic parameters #adr ST A <CR>[<LF>] #adr ,xxxxxx,yyyyyy ,zzzzzz,sssss,iiii,www ,ppp,vvv ,ttttt<CR><LF> adr: address 543210 xxxxxx ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 25

    Use Alcatel V acuum T echnology France - ACT 250 addendum 24 January 2001 Controlling the pump from the ACT 250 controller Once all connections are complete, plug the controller into the mains. A C T 2 5 0 A C T 2 5 0 POWER F AUL T SPEED ST ART STOP Indicator lights “ box ” version “ OEM ” version Y ellow lit Controller on Red lit Controlle ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 26

    Use Alcatel V acuum T echnology France - ACT 250 addendum 25 January 2001 Controlling the pump from the ACT 250 controller ST ART STOP Star ting the pump with the ST AR T switch Stopping the pump with the STOP switch The pump is started up to reach the selected speed. The yellow rising speed indicator light comes on. When the pump reaches its selec ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 27

    Use Alcatel V acuum T echnology France - ACT 250 addendum 26 January 2001 Controller functions Precautions Local mode operation The Start and Stop functions use switches located on the front panel of the “ box ” version and on the board for the “ OEM ” version. The “ OEM ” version of the ACT 250 has been designed with electrical safety ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 28

    Use Alcatel V acuum T echnology France - ACT 250 addendum 27 January 2001 Controller functions Fault monitoring ■ Aler ts are indicated by: - fl ashing red indicator . The pump power supply is maintained. ■ Faults are indicated by: - lit red indicator . The pump is stopped as soon as a fault is detected. Alerts and faults shown by the indicato ...

  • Alcatel Carrier Internetworking Solutions ACT 250 - page 29

    France Alcatel V acuum T echnology - France 98, avenue de Brogny - BP 2069 74009 ANNECY - Cedex T el : (33) 4 50 65 77 77 Fax : (33) 4 50 65 77 89 Germany Alcatel Hochvakuum T echnik GmbH Am Kreuzeck 10 D – 97877 WERTHEIM T el: (49) 9342 96100 Fax: (49) 9342 961030 Italy Alcatel V acuum Systems S.p.A Via T rento, 30 20059 VIMERCA TE (MI) T el : ( ...

Fabricant Alcatel Carrier Internetworking Solutions Catégorie Paint Sprayer

Les documents que nous recevons du fabricant de l'appareilAlcatel Carrier Internetworking Solutions ACT 250 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Alcatel Carrier Internetworking Solutions
- manuels d’utilisations ACT 250
- fiches produit Alcatel Carrier Internetworking Solutions
- dépliants
- ou étiquettes-énergie Alcatel Carrier Internetworking Solutions ACT 250
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Alcatel Carrier Internetworking Solutions ACT 250.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Alcatel Carrier Internetworking Solutions ACT 250, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Alcatel Carrier Internetworking Solutions ACT 250. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Alcatel Carrier Internetworking Solutions ACT 250.

Manuel d’utilisation complet de l’appareil Alcatel Carrier Internetworking Solutions ACT 250, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Alcatel Carrier Internetworking Solutions ACT 250 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Alcatel Carrier Internetworking Solutions ACT 250.

Le manuel d’utilisation complet Alcatel Carrier Internetworking Solutions, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Alcatel Carrier Internetworking Solutions ACT 250 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Alcatel Carrier Internetworking Solutions ACT 250, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAlcatel Carrier Internetworking Solutions ACT 250 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Alcatel Carrier Internetworking Solutions ACT 250 - qui devraient nous aider dans les premières étapes lors de l'utilisation Alcatel Carrier Internetworking Solutions ACT 250
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Alcatel Carrier Internetworking Solutions ACT 250
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Alcatel Carrier Internetworking Solutions ACT 250 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Alcatel Carrier Internetworking Solutions ACT 250?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Alcatel Carrier Internetworking Solutions ACT 250, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Alcatel Carrier Internetworking Solutions ACT 250 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)