    DO NOT ST ORE OR USE GASOLINE OR OTHER FLAM- MABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from your neighbor ’s phone. Follow the gas ...

  • Vermont Casting 2465 - page 2

    2 Dutchwest Direct V ent / Natur al V ent Gas Heater 30001935 T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these ins ...

  • Vermont Casting 2465 - page 3

    3 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 General Information The Dutchwest Direct V ent/Natural V ent Room Heater , Model Nos. 3070, 3071, 3072 and 3073, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for V ented Room Heaters, and CSA 2.17- M91, Gas-Fired Appliances For Use at High Altitude ...

  • Vermont Casting 2465 - page 4

    4 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Dutchwest Direct V ent / Natural V ent Dimensions C L V alve Inlet 23" (584mm) 6  " (172mm) 24  " (622mm) C L V alve Inlet 1935 Dutchwest DV/NV dimensions 5/15/03 28  " (721mm) 12  " (318mm) 17" (419mm) 4  " ( ...

  • Vermont Casting 2465 - page 5

    5 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Installation Requirements The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFP A 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude. Main- tain the manifold pressure at 3.5” w .c. fo ...

  • Vermont Casting 2465 - page 6

    6 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Parallel Installation: Minimum Clearance and Flue Centerline, Direct V ent and Natural V ent ST128b Stardance flue centerline 9/28/00 djt C L C L B D C A ST128c Stove Clearances A: 4” (102 mm) B: 4” (102 mm) Pipe Centerlines C: 15 ¹⁄₂ ” (395 mm) D: 9” (229 mm) Fig. 3 Parallel ...

  • Vermont Casting 2465 - page 7

    7 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/h 2465 Nat Millivolt 28,000 20,000 2466 Prop Millivolt 28,000 19,000 Gas Specifications Weight: Fully assembled; 202 lbs. Gas Inlet and Manifold Pressures Natural LP (Propane) Inlet Minimum 5.5” w .c. 1 1.0” w .c. Inlet Maximum 1 ...

  • Vermont Casting 2465 - page 8

    8 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V ertical T ermination - Direct V ent ONL Y A vertical vent system must terminate no less than 8’ (2.44m) and no more than 40’ (12m) above the appli- ance flue collar . A 2 ¹⁄₄ ” restrictor plate (supplied) must be used where specified in all vertically terminated vent system ...

  • Vermont Casting 2465 - page 9

    9 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting T ermination Clearances Y our stove is approved to be vented either through the side wall, or vertical through the roof. • This unit does not require any opening for in- spection of vent pipe. • Only CFM Corporation and Simpson DuraV ent venting components specifically appro ...

  • Vermont Casting 2465 - page 10

    10 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Canadian Installations 1 US Installations 2 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I   Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev . 12/05/0 ...

  • Vermont Casting 2465 - page 11

    1 1 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Fig. 10 T ermination clearances. V enting Requirements - Natural V ent Only FP567 NVBR/NVBC VENTING RUNS 11/12/97 V enting Runs Horizontal Run (in feet) V ertical Run (in feet) (Measured from top of the unit before any elbow) A: V ertical installations up to 36 feet (12m) in height. ...

  • Vermont Casting 2465 - page 12

    12 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting Requirements and Options - Direct V ent ONL Y Approved V ent System Components The Dutchwest Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropriate listed venting components specified ...

  • Vermont Casting 2465 - page 13

    13 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, V enting System Assembly . 1. The fan kit includes a Blower Assembly and a Rheo - stat Assembly , connected by a cable. (Fig. 12 ...

  • Vermont Casting 2465 - page 14

    14 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting System Assembly - Direct V ent General Information The Dutchwest is approved for installation only with the vent components listed on Page 12. Follow the vent component instructions exactly . For U.S. installations: The venting system must con- form with local codes and/or the c ...

  • Vermont Casting 2465 - page 15

    15 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Install the V ent Adapter Pipe (Simpson Dura-V ent Components) 1. Install the Restrictor Plate. Consult the ‘V ent Run Specifications’ on Page 8 to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within the inner flue collar . (Fig. 16) 2. ...

  • Vermont Casting 2465 - page 16

    16 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 For DuraV ent pipe only: Install vent pipe by align- ing the locking system together , sliding the pipes together and twisting clockwise. • Install 90° elbow . T wist lock as before. • Slide the wall plate over horizontal run before at - taching the horizontal run to the elbow . Fas ...

  • Vermont Casting 2465 - page 17

    17 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V ent T ermination Below Grade Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below grade level. The seven inches is measured ...

  • Vermont Casting 2465 - page 18

    18 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward. 9. Install the storm collar and seal around the joints. (Fig. 31) 10. Add additional vent lengths to achieve the proper overall height. 1 1. A ...

  • Vermont Casting 2465 - page 19

    19 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Attach the first section of venting to the draft hood. De- pending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. Th ...

  • Vermont Casting 2465 - page 20

    20 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 In the U.S.; Gas connection should be made in ac- cordance with current National Fuel Gas Code, ANSI Z223.1/NFP A 54. Since some municipalities have additional local codes, be sure to consult your local authority . In Canada; consult the local authority and CSA-B149.1 installation code. ...

  • Vermont Casting 2465 - page 21

    21 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 8. The air shutter is located on the bottom of the burner to the left. (Fig. 37) Unfasten the two nuts holding the shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open. Reassemble the shutter to allow the rear injector air inlet to close from th ...

  • Vermont Casting 2465 - page 22

    22 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation. Thermostat Wire / Gauge Maximum Run 18 20 feet 16 20 - 40 feet 14 up to 60 feet ...

  • Vermont Casting 2465 - page 23

    23 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Operation Y our First Fire Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly , Figure 45. Follow the lighting instructions on Page 25 exactly . During the first fire, it is not unusual to smell some odor associated with new ...

  • Vermont Casting 2465 - page 24

    24 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on ...

  • Vermont Casting 2465 - page 25

    25 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 T roubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. W ARNING: REMOVE THE GLASS P ANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK. SYMPTOM POSSIBLE CAUSES CORRECTIVE AC ...

  • Vermont Casting 2465 - page 26

    26 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Fuel Conversion Instructions W ARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions i ...

  • Vermont Casting 2465 - page 27

    27 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Pilot Orifice Conversion 1. Locate pilot. (Fig. 49) 2. Replace pilot orifice. Pilot T ype 1 • Remove pilot hood by lifting up. (Fig. 53) Do not remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conver- sion. • Remove pilot orifice with a ...

  • Vermont Casting 2465 - page 28

    28 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 21. Replace burner . Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possib ...

  • Vermont Casting 2465 - page 29

    29 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Maintenance Y our Dutchwest Gas Heater will provide years of ser - vice with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualified ga ...

  • Vermont Casting 2465 - page 30

    30 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer . Shut off the gas supply and allow the stov ...

  • Vermont Casting 2465 - page 31

    31 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Wiring Diagrams OFF ON Thermostat (Optional)  Therm opile Black Black Millivolt Gas Valve St124b on/off/s witch wiring 1/11/00 djt TP/TH TP TH On/Off Switch Wiring ST124b Thermostat (Optional)  Therm opile Black Black Millivolt Gas Valve St124c Ther mostat? ...

  • Vermont Casting 2465 - page 32

    32 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 1a 1b 1c 2 10 12 1 1 PILOT ON OFF PILOT ADJ L O H I 23 27 28 32 CEMENT 34 35 1 3 4 6 7 5 8 13a,b 15a 17 19 14 18 20 21 15b 16a,b, c,d 25 26 24 33 29 31 9 22 30 1935 Dutchwest parts 5/16/03 djt 30 36 37a,b 38 CFM Corporation reserves the right to make changes in design, materials, speci? ...

  • Vermont Casting 2465 - page 33

    33 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Ref. Description Dutchwest Dutchwest Direct V ent / Natural V ent Gas Heater Models 2465, 2466 (continued) 10. Glass, DV25 1601691 1 1. Glass Frame Assembly - SDV30 30000127 12. Gasket, Glass - Med. Knit - RDV40 1203702 13a. V alve RN Honeywell VS8420E 2038 (Serial #’s up to 6413)* 100 ...

  • Vermont Casting 2465 - page 34

    34 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture. A rheostat provide ...

  • Vermont Casting 2465 - page 35

    35 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 LIMITED LIFETIME W ARRANTY PRODUCT COVERED BY THIS W ARRANTY All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner . BASIC W ARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace/Stove is free f ...

  • Vermont Casting 2465 - page 36

    Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2465 63.0 2466 63.0 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation ...

Fabricant Vermont Casting Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilVermont Casting 2465 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vermont Casting
- manuels d’utilisations 2465
- fiches produit Vermont Casting
- dépliants
- ou étiquettes-énergie Vermont Casting 2465
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vermont Casting 2465.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vermont Casting 2465, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vermont Casting 2465. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vermont Casting 2465.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vermont Casting 2465, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vermont Casting 2465 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vermont Casting 2465.

Le manuel d’utilisation complet Vermont Casting, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vermont Casting 2465 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vermont Casting 2465, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVermont Casting 2465 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vermont Casting 2465 - qui devraient nous aider dans les premières étapes lors de l'utilisation Vermont Casting 2465
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vermont Casting 2465
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vermont Casting 2465 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vermont Casting 2465?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vermont Casting 2465, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vermont Casting 2465 il est probable qu’il a envie de partager la façon de le résoudre.