  • AquaStar 125B LP - page 1

    W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applianc ...

  • AquaStar 125B LP - page 2

    2 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquastar . This same flow opens the gas valve, and the burners are ignited by th ...

  • AquaStar 125B LP - page 3

    3 ...

  • AquaStar 125B LP - page 4

    4 If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below) , all piping and other components connected to the system must be suitable for potable water , (b) toxic chemicals such as those commonly used for boiler treatment to prevent corrosion and freezing must not be introduced into the syste ...

  • AquaStar 125B LP - page 5

    5 4. Y ou must vent your heater. See section on V ent Pipe Connections, Page 5. 5. The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any p ...

  • AquaStar 125B LP - page 6

    6 CLEARANCES The Aquastar 125 B is design certified for installation on a combustible wall and for installation in an alcove with the minimum clearances to combustible and non -combustible construction listed below A. T op 12 inches ( 305 mm) B. Front Open C. Back 0 inches D. Sides 4 inch (102mm) E. Bottom 12 inches (306 mm) Clearance from vent is ...

  • AquaStar 125B LP - page 7

    7 The flue connection for the AquaStar 125B is 5 inches. However , in Canada, for installations at high altitude (2000- 4500 feet above sea level) a six inch flue is required. A 5" by 6" flue adaptor must be affixed to the flue collar of the AquaStar with at least two screws. See figure 3 Fig. 3 - Flue Adaptor for High Altitude Installati ...

  • AquaStar 125B LP - page 8

    8 OPERA TING INSTRUCTIONS Before proceeding with the operation of the heater make sure that the system is filled with water . Make sure the water heater drain plug is closed. See Figure 7 below . Fig. 7 - W ater heater drain plug Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater an ...

  • AquaStar 125B LP - page 9

    9 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. W ait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above on this plate. If you don’t smell gas, ...

  • AquaStar 125B LP - page 10

    10 TROUBLE SHOOTING Introduction The AquaStar 125 burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up in faucet ...

  • AquaStar 125B LP - page 11

    11 6 . Faulty thermocouple (part #8747202083) or electromagnet ) Unless these 2 parts are at least 8 to 10 years old, it is very unlikely that they are faulty . Before testing, reconfirm that #2 is absolutely correct, and that all connections are clean and tight. T o test the thermocouple, disconnect the thermocouple lead to the ECO. Insert a multi ...

  • AquaStar 125B LP - page 12

    12 PILOT LIGHT GOES OUT DURING OR IMMEDIA TEL Y AFTER HOT W A TER HAS BEEN USED 1. Gas pressure too low V ery low gas pressure may be caused by low delivered gas pressure, a jammed gas regulator or undersized gas lines. If the gas lines are undersized, there may still be the specified static gas line pressure. However when the water valve opens, an ...

  • AquaStar 125B LP - page 13

    13 Fig. 1 1 - Diagram of AquaStar 125 B 5 11 1 4 9 10 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. Pressure tap screw location 8. Gas control slide 9. Piezo igniter 10. W ater valve 1 1. T emperature adjustment selector 12. Gas inlet gas pressure test nipple 3 ...

  • AquaStar 125B LP - page 14

    14 Fig. 12 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST ...

  • AquaStar 125B LP - page 15

    15 Fig. 12 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125B 1 Cover ¤ 8 705 421 025 2 Plastic collar ¤ 8 700 403 008 3 T emperature adjustment knob ¤ 8 702 000 1 1 1 4 Panel back ¤ 8 705 402 164 5 Draft divertor ¤ 8 705 505 354 6 Heat exchanger ¤ 8 705 406 235 7 Hot water pipe ¤ 8 700 705 556 8 Cold water pipe ¤ 8 700 705 294 9 Heat exchang ...

  • AquaStar 125B LP - page 16

    Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.com GA S LINE SIZE Natural Gas Nominal Iron Pipe Size* 1/2&qu ...

Fabricant AquaStar Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilAquaStar 125B LP peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques AquaStar
- manuels d’utilisations 125B LP
- fiches produit AquaStar
- dépliants
- ou étiquettes-énergie AquaStar 125B LP
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation AquaStar 125B LP.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation AquaStar 125B LP, manuels d’entretien, brefs manuels ou manuels de l’utilisateur AquaStar 125B LP. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit AquaStar 125B LP.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil AquaStar 125B LP, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser AquaStar 125B LP par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs AquaStar 125B LP.

Le manuel d’utilisation complet AquaStar, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel AquaStar 125B LP - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières AquaStar 125B LP, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAquaStar 125B LP qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil AquaStar 125B LP - qui devraient nous aider dans les premières étapes lors de l'utilisation AquaStar 125B LP
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de AquaStar 125B LP
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service AquaStar 125B LP dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de AquaStar 125B LP?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec AquaStar 125B LP, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec AquaStar 125B LP il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)