    www .edelbrock.com Page 1 of 17 Please study these instructions carefully before installing your new Progressive Nitrous Contoller . If you have any questions, please contact our T echnical Hotline at : 1-800-416-8628 from 7 am - 5pm, Monday-Friday , Pacific Standard Time or e-mail us at Edelbrock@Edelbrock.com . Important Information - Y ou must u ...

  • Edelbrock 71900 - page 2

    www .edelbrock.com Page 2 of 17 71900 - Progressive Nitrous Controller The 71900 Progressive Nitrous Controller was designed using the latest digital technology a vailable. The result is a controller which is extremely accurate and user -friendly . A simple and functional programming interface allows the user to set important nitrous parameters in ...

  • Edelbrock 71900 - page 3

    www .edelbrock.com Page 3 of 17 Nitrous Delay T imer: A digital timer is provided that can be used to delay the start of the nitrous. This timer begins counting down when the activation terminal is on (+12v a pplied). If the activation signal is removed, the delay timer will halt until the signal is re-applied. The delay timer can be programmed fro ...

  • Edelbrock 71900 - page 4

    www .edelbrock.com Page 4 of 17 T ABLE OF CONTENTS Page # Programming +12 V olt Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Nitrous Delay T imer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ...

  • Edelbrock 71900 - page 5

    www .edelbrock.com Page 5 of 17 Programming the +12 Volt Timer Press and release the FUNCTION switch until the message “+12V T imer Delay” a ppears on the display . After the function message has scrolled across the display , the current +12 Volt Timer setting will appear on the display . T o adjust the +12 volt timer value, press the desired d ...

  • Edelbrock 71900 - page 6

    www .edelbrock.com Page 6 of 17 Programming the Nitrous Starting Percentage Press and release the FUNCTION s witch until the message “Starting Percentage” appears on the display . After the function message has scrolled across the display , the current nitrous starting percentage setting will appear on the display . T o adjust the nitrous start ...

  • Edelbrock 71900 - page 7

    www .edelbrock.com Page 7 of 17 Programming the Nitrous Power Ramp Time NOTE - If the dual ramp feature is enabled fron the options menu, there will be a “Nitrous Build Time #2” in the menu list. The programming method is the same as the “Build Time #1”. Please refer to the section “Options Menu” and “Using the Dual Ramp Feature” fo ...

  • Edelbrock 71900 - page 8

    www .edelbrock.com Page 8 of 17 Viewing Run Data and Entering the Options Menu Press and release the FUNCTION switch until the message “Edelbrock Nitrous Systems - 71900” appears on the display . Press and hold the ENTER s witch, the display will show the time at which the activation input was turned OFF for the previous progressive cyc le. Aft ...

  • Edelbrock 71900 - page 9

    www .edelbrock.com Page 9 of 17 Setting the Dual Nitrous Power Ramp ON/OFF Enter the Options Menu, press and release the FUNCTION s witch until the message “Dual Ramp Nitrous” appears on the display . Press and release the ENTER switch to turn this feature ON or OFF . After pressing the ENTER s witch, the display will show the new state of the ...

  • Edelbrock 71900 - page 10

    www .edelbrock.com Page 10 of 17 Setting +12V Timer Output Hold ON/OFF Enter the Options Menu, press and release the FUNCTION s witch until the message "+12V Timer Output Hold" appears on the display . Press and release the ENTER switch to turn this feature ON or OFF . After pressing the ENTER switch, the display will show the new state o ...

  • Edelbrock 71900 - page 11

    www .edelbrock.com Page 11 of 17 How the Dual Power Ramp Functions The dual nitrous ramp feature enables the user to have more precise control over the nitrous po wer ramp. When the dual ramp feature is enabled, there are two more selections added to the Main Menu. These are "Final Percent #1" and "Nitrous Build Time #2". Using ...

  • Edelbrock 71900 - page 12

    www .edelbrock.com Page 12 of 17 Items Included with the 71900 Controller 1 - Wiring Harness 2 - Installation & User Manual Items Needed that are NOT Supplied with Controller 1 - Nitrous Kit 2 - Safety Solenoid 3 - Activation Switches as needed, if they were not inc luded with the nitrous kit. 4 - RPM Window Switch; required in EFI vehic les th ...

  • Edelbrock 71900 - page 13

    www .edelbrock.com Page 13 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc An optional RPM windo w switch may be connected here. Any RPM switch with a ground control output may be used. NOTE - Most factory fuel injection systems will cut the fuel during an over-rev condition. If the nitrous is NOT controlled ...

  • Edelbrock 71900 - page 14

    Progressive Controller Wiring Diagram with Several Options Page 14 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc Nitrous Arming Switch T rans Brake Button +12 Volt +12 Volt T rans Brake Solenoid Ground Ground Micro Switch 87A 87 30 85 86 87A 87 30 85 86 87A 87 30 85 86 87A 87 30 85 86 MSD 2 Step 1 2 Ground ...

  • Edelbrock 71900 - page 15

    www .edelbrock.com Page 15 of 17 Electrical Specifications Normal Operating Voltage 10.0 to 16.0 Volts, Nega tive Ground Controller will turn OFF at 6.2 Volts +12 Volt Timer Output 1 AMP Maximum, 80mA sink to ground when timer output is OFF . Nitrous Solenoid Ground 45 AMPs Maximum Activation Input .5mA at 12.0 Volts Weight .8 lb. Overall Height 1. ...

  • Edelbrock 71900 - page 16

    www .edelbrock.com Page 16 of 17 ©2008 Edelbrock Corporation Catalog #71900 Brochure #63-0473 Rev . 08/08 - AJ/mc Controller Wiring Controller power and ground wires should be routed directly to the batter y or other isolated po wer source. F or excessive distances, supplied po wer wires should be replaced with heavier gauge wire. T wo red wires a ...

  • Edelbrock 71900 - page 17

    www .edelbrock.com Page 17 of 17 SERVICE In the event that your Progressive Nitrous System should need ser vicing, return the unit freight pre-paid to the Edelbrock Service and Repair facility a t 2700 California Street, T orrance, CA 90503. Do not attempt to disassemble or service the components of the system yourself. Doing so may void the warran ...

Fabricant Edelbrock Catégorie Automobile Parts

Les documents que nous recevons du fabricant de l'appareilEdelbrock 71900 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Edelbrock
- manuels d’utilisations 71900
- fiches produit Edelbrock
- dépliants
- ou étiquettes-énergie Edelbrock 71900
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Edelbrock 71900.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Edelbrock 71900, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Edelbrock 71900. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Edelbrock 71900.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Edelbrock 71900, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Edelbrock 71900 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Edelbrock 71900.

Le manuel d’utilisation complet Edelbrock, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Edelbrock 71900 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Edelbrock 71900, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEdelbrock 71900 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Edelbrock 71900 - qui devraient nous aider dans les premières étapes lors de l'utilisation Edelbrock 71900
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Edelbrock 71900
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Edelbrock 71900 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Edelbrock 71900?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Edelbrock 71900, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Edelbrock 71900 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)